• Title/Summary/Keyword: Branch Tube

Search Result 66, Processing Time 0.02 seconds

A numerical study on the flow characteristics and condensed water inflow in the Venturi tube with T-branch tube (T-분지관이 부착된 벤튜리관의 유동특성과 응축수 유입에 대한 수치해석 연구)

  • Kim, S.I.;Park, S.H.;Hwang, J.G.
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.173-181
    • /
    • 2019
  • This study was carried out numerically to investigate the flow characteristics in the Venturi tube with $90^{\circ}$ T-branch tube and the inflow of condensed water into the Venturi tube from the branch tube. In this study, the diameter of the branch tube(1, 2, 3mm) and the neck diameter of the Venturi tube(0.3, 0.9, 1.5mm) were varied. The flow rate of the water at the Venturi tube inlet is 80cc/min and the water temperature is 288K. The condensed water temperature at the branch tube inlet is 355K. It was found that the velocity and pressure of the fluid near the branch point in the Venturi tube were more dependent on the diameter of the Venturi tube than the diameter of the branch tube. The temperature of the mixed water at the exit of the Venturi tube was the highest when the Venturi tube's neck diameter is 0.9mm and the branch tube diameter is 2mm. This means that the condensed water is flowing well through the branch tube.

Experimental Study on the Characteristics of Pressure Fluctuation in the Combustion Chamber with Branch Tube (분기관을 가진 연소 챔버 내 압력변동 특성에 관한 실험적 연구)

  • Park, Jang-Hee;Lee, Dae-Keun;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.552-558
    • /
    • 2009
  • An experimental study using the combustor with branch tube was conducted in order to model the industry combustor with FGR (flue gas recirculation) system and to study a thermo-acoustic instability generated by a branch tube. The branch tube is a structure used to modify a system geometry and then to change its pressure field, and the thermo-acoustic instability, usually occurs in a confined geometry, can result in serious problems on industrial combustors. Thus understanding of the instability created by modifying geometry of combustor is necessary to design and operate combustor with FGR system. Pressure fluctuation in the combustion chamber was observed according to diameter and length of branch and it was compared with the solution of 1-D wave equation. It was found that branch tube affects the pressure field in the combustion chamber, and the pressure fluctuation in the combustion chamber was reduced to almost zero when phase difference between an incipient wave in the combustion chamber and a reflected wave in the branch tube is $\pi$ at the branch point. Also, the reduction of pressure fluctuation is irrespective of the installed height of branch tube if it is below $h^*=0.9$ in the close-open tube and open-open tube.

Two-Phase Flow Distribution and Phase Separation Through Both Horizontal and Vertical Branches

  • Tae, Sang-Jin;Keumnam Cho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.8
    • /
    • pp.1211-1218
    • /
    • 2003
  • The present study investigated two-phase flow distribution and phase separation of R-22 refrigerant through various types of branch tubes. The key experimental parameters were the orientation of inlet and branch tubes (horizontal and vertical), diameter ratio of branch tube to inlet tube (1 and 0.61), mass flux (200-500 kg/㎡s), and inlet quality (0.1-0.4). The predicted local pressure profile in the tube with junction was compared and generally agreed with the measured data. The local pressure profile within the pressure recovery region after the junction has to be carefully investigated for modeling the pressure drop through the branch. The equal flow distribution case can be found by adjusting the orientation of the inlet and branch tubes and the diameter ratio of the branch tube to the inlet tube. The T-junction with horizontal inlet and branch tubes showed the nearly equal phase distribution ratio. The quality at the branch tube varied from 0 to 1 as the orientation of the branch tube changed, while it varied within${\pm}$50% as the orientation of the inlet tube changed.

Two-phase Flow Characteristics of Refrigerant in T-branch with Horizontal and Vertical Inlet Tube (T형 수평 및 수직 입구 분지관 내 냉매 2상 유동 특성)

  • 태상진;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.741-748
    • /
    • 2002
  • The present study investigated the two-phase flow characteristics of refrigerant R-22 in T-branch with horizontal and vertical inlet tube The key experimental parameters were the orientation of inlet and branch tubes (horizontal and vertical), diameter ratio of branch tube to inlet tube (1 and 0.61), inlet mass flux (200~500 kg/$m^2$s) and inlet quality (0.1~0.4). Predicted pressure profile agreed with the measured data within 25.4%. The flow distribution ratio decreased as the mass flux increased. The flow distribution ratio decreased by 12~25% as the tube diameter ratio decreased from 1 to 0.61, and decreased by 38~47% as the orientation of branch changed from horizontal to vertical upward for horizontal inlet tubes. As the orientation of inlet tube changed from horizontal to vertical upward for horizontal branch, the flow distribution ratio increased by 15~68%, but the quality in the branch tube decreased by 28~92% due to phase separation.

Effect of Flow Direction on Two-Phase Flow Distribution of Refrigerants at a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.717-727
    • /
    • 2006
  • The present study experimentally investigated the effect of flow direction and other flow parameters on two-phase flow distribution of refrigerants at a T-junction, and also suggested a prediction model for refrigerant in a T-junction by modifying previous model for air-water flow. R-22, R-134a, and R-410A were used as test refrigerants. As geometric parameters, the direction of the inlet or branch tube and the tube diameter ratio of branch to inlet tube were chosen. The measured data were compared with the values predicted by the models developed for air-water or steam-water mixture in the literature. We propose a modified model for application to the reduced T-junction and vertical tube orientation. Among the geometric parameters, the branch tube direction showed the biggest sensitivity to the mass flow rate ratio for the gas phase, while the inlet quality showed the biggest sensitivity to the mass flow rate ratio among the inlet flow parameters.

Buckling of porosity-dependent bi-directional FG nanotube using numerical method

  • Wang, Haiquan;Zandi, Yousef;Gholizadeh, Morteza;Issakhov, Alibek
    • Advances in nano research
    • /
    • v.10 no.5
    • /
    • pp.493-507
    • /
    • 2021
  • This article focused on studying the buckling behavior of two-dimensional functionally graded (2D-FG) nanosize tubes, including porosity based on first shear deformation and higher-order theory of tube. The nano-scale tube is simulated based on the nonlocal gradient strain theory, and the general equations and boundary conditions are derived using Hamilton's principle for the Zhang-Fu's tube model (as higher-order theory) and Timoshenko beam theory. Finally, the derived equations are solved using a numerical method for both simply-supported and clamped boundary conditions. The parametric study is performed to study the effects of different parameters such as axial and radial FG power indexes, porosity parameter, nonlocal gradient strain parameters on the buckling behavior of di-dimensional functionally graded porous tube.

Experimental and numerical study of one-sided branch plate-to-circular hollow section connections

  • Hassan, M.M.;Ramadan, H.;Abdel-Mooty, M.;Mourad, S.A.
    • Steel and Composite Structures
    • /
    • v.19 no.4
    • /
    • pp.877-895
    • /
    • 2015
  • Connections to circular hollow steel sections (CHS) are considered one of the most complex and time consuming connections in steel construction. Such connections are usually composed of gusset plates welded to the outside of the steel tube or penetrating the steel tube. Design guides, accounting for the effect of connection configuration on the strength of the connection, are not present. This study aims to investigate, through experimental testing and a parametric study, the influence of connection configuration on the strength of one sided branch plate-to-CHS members. A notable effect was observed on the behavior of the connections due to its detailing changes with respect to capacity, failure mode, ductility, and stress distribution. A parametric study is performed using the calibrated analytical model to include a wider range of parameters. The study involves 26 numerical analyses of finite element models including parameters of the diameter-to-thickness (D/t) ratio, length of gusset plate, and connection configuration. Accordingly, a modification to the formulas provided by the current design recommendations was suggested to include connection configuration effects for the one sided branch plate-to-CHS members.

Computer Simulation of the Transanal Endoscopic Microsurgery for the Improvement of Optimal Operation Range (경항문 내시경 수술 도구에서의 최적 활동 반경 개선을 위한 컴퓨터 시뮬레이션 연구)

  • Kim, Hyung-Tae;Kim, Kwang-Gi;Sohn, Dae-Kyung;Kim, Hyun-Ho;Nam, Kyoung-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.482-488
    • /
    • 2009
  • Conventional devices for transanal endoscopic microsurgery that are currently used clinically for intestine or rectal cancer patients have 40 mm external diameter of rectoscope tube - induces anal damage and long-term postoperative pain for small-sized patients. In this paper, we designed rectum and rectoscope models and calculated the changing trends of operation area of the surgical tools in accordance with the step-by-step variation of design parameters of the rectoscope tube - external diameter, axial length, and distal angle. Using the results of computer simulation, we suggested an optimal set of design parameters that minimizes external diameter of the rectoscope tube and at the same time, maintains similar operation area of the surgical tools compared with commercialized devices (${\geq}\;4274.7mm^2$). The results of the simulation showed that the optimal design parameters were 35 mm external diameter, 100 mm axial length, and $45^{\circ}$ distal angle of the rectoscope tube. This result can be applied to the development of endoscopic microsurgery device that can minimize side effects to the intestine or rectal cancer patients.

Experimental Approach for Estimation of Hydrodynamic Force Acting on a Submerged Streamlined Body Translating in a One-end-opened Cylindrical Tube (수중운동체의 실린더 관 내부 이동시 작용력 예측에 대한 실험적 접근)

  • Yeo, Dong-Jin;Kim, Yeon-Gyu;Kim, Dong-Hun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.2
    • /
    • pp.203-211
    • /
    • 2012
  • The main object of this experiment is to estimate the hydrodynamic forces acting on a submerged streamlined body placed in a one-end-opened cylindrical tube moving with certain translational velocity. The best experimental design for this object is mimicking real situation, however sizes of model body and cylinder tube are just the same as those of real, for avoiding scale effects, mimicking real situation is not realizable. Hence, in this experiment, target body and cylindrical tube were designed to be towed with varying body position relative to cylindrical tube. For measuring hydrodynamic forces and flow velocity in the cylindrical tube, six one-component load cells and several one-hole Pitot tubes were used. Several conditions were checked with various end-plates those had different opening areas. Experiment results show that forces and flow velocity had different tendency with those expected, and the presence of a end-plate slows down the flow velocity in the cylindrical tube and affects pressure field in the tube to push the model submerged body forward of the tube. This tendency grows with decreasing opened area.

A comparison of agglutination tests and enzyme-linked immunosorbent assay for the bovine brucellosis (소 브루셀라병 혈청 항체가 응집반응 비교 시험)

  • Kim, Cheol-Ho;Bang, Sang-Young;Jeon, Jae-Hyung;Bhak, Jong-Sik;Lee, Min-Kwon;Shin, Jung-Sub
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.3
    • /
    • pp.315-329
    • /
    • 2008
  • A total of 710 bovine serum samples which are composed 532 bovine serum samples showed negative reaction and 178 bovine serum samples showed positive reaction with tube agglutination test (TAT) from North area of Gyeong-nam, Korea were tested using all the 3 assays which are Rose-Bengal test(RBT), tube agglutination test (TAT) and enzyme-linked immunosorbent assay (ELISA, two types) and analyzed for evaluation of specificity, sensitivity, reproducibility and predictive value. In the comparison of serum antibody titer agglutination test, RBT showed almost agreement with TAT. In the comparison of TAT and two types of ELISA method, they showed difference in specificity and sensitivity about 5%. But there is no significant difference in detecting sensitivity between two types of ELISA method and TAT. In serologic tests for bovine brucellosis, the new assay ELISA would be a good candidate for serologic survey for bovine brucellosis in Korea because it is efficient in detecting many test samples quickly. But the serum agglutination tests (RBT, TAT) are more economical and easy assay for detection. In the test of comparison of antibody titer between first day of finding and 10 days after finding by TAT, there was no change in 55% (76/139) of positive cattle.