• Title/Summary/Keyword: Braking energy

Search Result 221, Processing Time 0.024 seconds

Operation Modes of a Power Split Hybrid Electric Vehicle (동력 분기 하이브리드 전기 자동차의 운행 모드 시뮬레이션)

  • Ahn Kuk-Hyun;Cho Sung-Tae;Lim Won-Sik;Park Yeong-Il;Lee Jang-Moo
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.23-27
    • /
    • 2006
  • The power split hybrid powertrain is considered to be one of the most prospective configuration for the hybrid electric vehicle (HEV). Toyota Prius, representing this type of vehicle, showed outstanding performances in fuel efficiency, emission reduction and acceleration. The excellence is largely due to the fact that it utilizes almost all operation modes of HEV. Those modes include ZEV (Zero Emission Vehicle) driving, idle stop, fuel cut-off, power assist, active charging, regenerative braking and so forth. In this paper, a few of the mode operations were simulated using AVL Cruise. Also, control logics to operate the powertrain in each mode were developed. The states of powertrain components were displayed and analyzed. By controlling the three components (engine, motor and generator), it was possible to run the powertrain in several hybrid operation modes.

  • PDF

Implementation of DC/DC Power Buck Converter Controlled by Stable PWM (안정된 PWM 제어 DC/DC 전력 강압 컨버터 구현)

  • Lho, Young-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.4
    • /
    • pp.371-374
    • /
    • 2012
  • DC/DC switching power converters produce DC output voltages from different stable DC input sources regulated by a bi-polar transistor. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The voltage mode DC/DC converter is composed of a PWM (Pulse Width Modulation) controller, a MOSFET (Metal Oxide Semiconductor Field Effect Transistor), an inductor, and capacitors, etc. PWM is applied to control and regulate the total output voltage. It is shown that the output of DC/DC converter depends on the variation of threshold voltage at MOSFET and the variation of pulse width. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by SPICE (Simulation Program with Integrated Circuit Emphasis) and experiments.

A Study on Capacity Selection of Accumulator by Mathematical Model in Hydraulic Regenerative Brake System (수학적 모델에 의한 유압 재생 브레이크 시스템의 축압기 용량 선정에 관한 연구)

  • 이재구;함영복;김도태;김성동
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.2
    • /
    • pp.48-55
    • /
    • 2001
  • An accumulator in hydraulic systems stores kinetic energy during braking action, and then that control hasty surge pres-sure. This study suggests a method to select the capacity of accumulator to control surge pressure to a desired degree. The selection method is based upon a trial and error approach and computer simulation. A mathematical dynamic model of the system was derived and the parameters in the model were identified from experimental data. A series of computer simulation were done for the brake action. The results of the simulation work were compared with those of experiments. These results of the computer simular-tion and experiments show that the proposed method can be applied effectively to control the surge pressure of the hydraulic regenerative brake systems.

  • PDF

A Study on the Capacity Design of Accumulator in Hydraulic Regenerative Brake System (유압 재생 브레이크 시스템의 축압기 용량설계에 관한 연구)

  • 이재구
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.348-354
    • /
    • 2000
  • An accumulator in hydraulic systems stores kinetic energy during braking action, and then that controls a hasty surge pressure. This study suggests a method ot determine the capacity of the accumulator to control surge pressure to a desired degree. A mathematical dynamic model of the system was derived and the parameters in the model were identified from experimental data. A series of computer simulation were done for the brake action. The results of the simulation work were compared with those of experiments. These results of the computer simulation and experiments shows that the proposed design method of the accumulator was verified in controlling surge pressure of the system.

  • PDF

A STUDY ON THE THERMAL FATIGUE TEST AND ANALYSIS METHOD FOR THE DEVELOPMENT OF BRAKE DISK MATERIALS

  • Lim, Choong-Hwan;Goo, Byeong-Choon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.127-131
    • /
    • 2008
  • In the disk braking of the railway trains, kinetic energy of the vehicles is converted into thermal energy by friction between a brake disk and the pad materials. This can be cause of the iterative thermal shock and generates thermal cracks on the brake disk surface. In this study, we show the comparative thermal fatigue test procedures and thermal crack analysis process to evaluate the thermal fatigue characteristics of candidate materials designed for development of heat-resistant brake disk material. We carried out tests on the conventional brake disk materials used for Saemaul and Mugunghwa trains, then we comparatively analyzed the thermal crack initiation and propagation on the surface of a specimen. A thermal fatigue test procedure and a crack analysis process were suggested to evaluate the heat resistance of the developed materials at later studies.

  • PDF

Multi-level Inverter for the Excitation Control of an SRM (SRM의 여자제어를 위한 멀티레벨 인버터)

  • 이상훈;박성준;안진우
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.4
    • /
    • pp.161-169
    • /
    • 2003
  • The applications of SRM(Switched Reluctance motor) are dramatically increasing due to a simple mechanical structure, a high efficiency and a high speed drive characteristics. Energy recovery in the regenerative region is very important when SRM is used in traction drive. This is to reduce energy loss during mechanical braking and/or to have a high efficiency drive. To control excitation voltage during motoring and regenerating voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper suggests multi-level inverter which is useful for motoring and regenerative operation. The proposed method is verified through simulations and experiments.

A Study on the Energy Saving Strategy in Electric Railway System (직류 전기철도 에너지 절감방안 연구)

  • Choi Byung-Woon;Chang Sang-Hoon;Kim Hak-Ryun
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.676-681
    • /
    • 2005
  • The regenerative braked cars are being introduced in DC electric railway for energy saving. There has been a recent tendency for DC traction substation with regenerative inverter to increase in number. This is strongly related to the desire for effective utilization of electric power regenerated by DC electric cars and to the aim ensuring stable operation of regenerative braking system. The regenerative inverters DC power feed back from a generative car into AC power at a substation and supplies it to distribution lines. This paper suggest the result of characteristic analysis and capacity simulation. economical analysis in the regenerative inverter system.

  • PDF

Multi-level Inverter for the Excitation Control of an SRM (SRM의 여자제어를 위한 멀티레벨 인버터)

  • 이상훈;박성준;안진우
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.161-161
    • /
    • 2003
  • The applications of SRM(Switched Reluctance motor) are dramatically increasing due to a simple mechanical structure, a high efficiency and a high speed drive characteristics. Energy recovery in the regenerative region is very important when SRM is used in traction drive. This is to reduce energy loss during mechanical braking and/or to have a high efficiency drive. To control excitation voltage during motoring and regenerating voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper suggests multi-level inverter which is useful for motoring and regenerative operation. The proposed method is verified through simulations and experiments.

Design and Control of DC/AC Converters in Parallel with Diode Rectifiers for Regenerative Applications

  • Gao, Zhigang;Li, Rui;Lu, Qi
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1071-1087
    • /
    • 2017
  • This paper introduces a DC/AC converter, which can be connected in parallel with a diode rectifier for regenerative applications. The DC/AC converter is supposed to transmit regenerative energy to the power grid when a motor is braking. Isolation transformers are not needed in the topology, which can reduce the size and cost. An analysis of the zero-order current existing in the system is carried out. In addition, algorithms to minimize the zero-order current, control the power factor and keep the DC bus voltage stable are discussed. A 55kW industrial prototype is built to verify the proposed analysis and control strategies.

Data analysis of simulated fuel-loaded sea transportation tests under normal conditions of transport

  • JaeHoon Lim;Woo-seok Choi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.375-388
    • /
    • 2024
  • In this study, to evaluate the shock and vibration load characteristics of used fuel, a sea transportation test was conducted using simulated fuel assemblies under normal transport conditions. An overall test data analysis was performed based on the measured strain and acceleration data obtained from cruise, rotation, acceleration, braking, depth of water, and rolling tests. In addition, shock response spectrum and power spectral densities were obtained for each test case. Amplification and attenuation characteristics were investigated based on the load path. The load was amplified as it passed from the overpack to the simulated used fuel-assembly. As a result of the RMS trend analysis, the fuel-loading position of the transportation package affected the measured strain in the fuel rod, and the maximum strains were obtained at the spans with large spacing. However, even these maximum strains were very small compared to the fatigue strength and the cladding yield strength. Moreover, the fuel rods located on the side exhibited a larger strain value than those at the center.