• 제목/요약/키워드: Brain Computer Interface

검색결과 196건 처리시간 0.033초

EEG신호를 이용한 뇌 신호원 국부화에 관한 연구 (Brain Source Localization using EEG Signals)

  • 정재철;송민;이희영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.133-136
    • /
    • 2002
  • EEG(Electroencephalography) is generated by electrical activity between neurons in cortical. Waveform of EEG is changed according to body and mental states. Therefore EEG is used to diagnosis of encephalophyma and epilepsy, etc. Also EEG is used to HCI(Human-Computer Interface). This paper describes estimation of orientation and location of dipole sources. The forward model is three-layer spherical head model and current dipole model. Using analytical solution, EEG is generated. Using MNLS(Minimum-Norm Least-Square) method, orientation and location of dipole moment is estimated.

  • PDF

AR 모델을 이용한 긍/부정 과제 수행시 뇌파분석 (Analysis of EEG for Yes/No decision task using AR model)

  • 남승훈;류창수;임태규;송윤선
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2002년도 추계학술대회 논문집
    • /
    • pp.250-254
    • /
    • 2002
  • 컴퓨터의 발달과 더불어 인간과 컴퓨터 인터페이스에 있어서도 많은 발전을 하고 있다. 본 연구는 두뇌-컴퓨터 인터페이스(brain-computer interface : BCI)를 위해서 인간에 있어서 가장 간단한 의사문제라고 여겨지는 긍정이나 부정을 선택할 때 나타나는 뇌파를 AR 모델을 이용하여 시간-주파수 분석을 한 후 topographical map을 그렸다. 그 결과 문제에 대답하는 시점 전후에서 파워스펙트럼이 유사하였고, 피험자가 문제를 읽고 판단하고, 동작하는 시점(reaction time : RT) 전으로 1초 ~ 0.5초 사이에 전두엽과 두정엽 부위에서 16Hz ~ 24Hz, 80 ∼ 88Hz의 주파수 대역에서 유의미한 차이를 보였다.

  • PDF

COSA : 뇌파를 이용한 방향 제어 시스템 (COSA : Cursor Control System by EEG)

  • 신동선;김응수
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2002년도 추계학술발표논문집 (상)
    • /
    • pp.801-804
    • /
    • 2002
  • 뇌기능 연구 수단으로 널리 사용되고 있는 뇌파의 시각적 분석 및 정량적 분석시 오차를 증가시키는 원인이 되어 왔던 잡파(artifact)를 제거 대상이 아닌 제어 신호로써 활용한다. 본 연구에서는 다양한 잡파 중 뇌파 측정시 가장 잘 포함되고, 시각적으로 쉽게 구별이 가능한 안면근(facial muscle) 신호를 이용한다. 측정된 뇌파에 파워스펙트럼(power spectrum)을 적응하여 뇌파를 분석하고, Backpropagation 알고리즘을 이용하여 전 처리된 뇌파를 인식하는 2 채널 실시간 인식(recognition) 및 분류(classification) 시스템을 구현한다. 이와 같이 구현된 시스템을 이용하여 5 방향(상, 하, 좌, 우, 정지) 제어를 실시함으로써 뇌-컴퓨터간 통신을 통한 방향제어 시스템을 구현하였다.

  • PDF

Extraction and classification of tempo stimuli from electroencephalography recordings using convolutional recurrent attention model

  • Lee, Gi Yong;Kim, Min-Soo;Kim, Hyoung-Gook
    • ETRI Journal
    • /
    • 제43권6호
    • /
    • pp.1081-1092
    • /
    • 2021
  • Electroencephalography (EEG) recordings taken during the perception of music tempo contain information that estimates the tempo of a music piece. If information about this tempo stimulus in EEG recordings can be extracted and classified, it can be effectively used to construct a music-based brain-computer interface. This study proposes a novel convolutional recurrent attention model (CRAM) to extract and classify features corresponding to tempo stimuli from EEG recordings of listeners who listened with concentration to the tempo of musics. The proposed CRAM is composed of six modules, namely, network inputs, two-dimensional convolutional bidirectional gated recurrent unit-based sample encoder, sample-level intuitive attention, segment encoder, segment-level intuitive attention, and softmax layer, to effectively model spatiotemporal features and improve the classification accuracy of tempo stimuli. To evaluate the proposed method's performance, we conducted experiments on two benchmark datasets. The proposed method achieves promising results, outperforming recent methods.

뇌파를 이용한 맞춤형 주행 제어 모델 설계 (EEG-based Customized Driving Control Model Design)

  • 이진희;박재형;김제석;권순
    • 대한임베디드공학회논문지
    • /
    • 제18권2호
    • /
    • pp.81-87
    • /
    • 2023
  • With the development of BCI devices, it is now possible to use EEG control technology to move the robot's arms or legs to help with daily life. In this paper, we propose a customized vehicle control model based on BCI. This is a model that collects BCI-based driver EEG signals, determines information according to EEG signal analysis, and then controls the direction of the vehicle based on the determinated information through EEG signal analysis. In this case, in the process of analyzing noisy EEG signals, controlling direction is supplemented by using a camera-based eye tracking method to increase the accuracy of recognized direction . By synthesizing the EEG signal that recognized the direction to be controlled and the result of eye tracking, the vehicle was controlled in five directions: left turn, right turn, forward, backward, and stop. In experimental result, the accuracy of direction recognition of our proposed model is about 75% or higher.

비접촉 눈 깜박임 측정 안경형 디바이스를 이용한 실시간 스펠러의 구현 (Development of Online Speller using Non-contact Blink Detection Glasses)

  • 이정수;이홍지;이원규;임용규;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권6호
    • /
    • pp.283-290
    • /
    • 2015
  • We proposed blink based online speller for the locked-in syndrome (LIS) patients, paralyzed in nearly all voluntary muscles expect for the eyes, with a simple and easy-to-use eye blink detection glasses. Electrooculogram (EOG) is the golden standard method of eye movement or blink measurement with Ag/AgCl electrodes. However, this method has several drawbacks such as skin irritation and dehydration of conductive gel. To resolve the shortcomings, we used a blink detection system based on a transparent capacitively coupled electrode, which is conductive indium tin oxide (ITO) films. The films make it possible to measure eye blink without direct skin contact and obstruction of field of view. We finally developed user-friendly blink based online speller with the blink detection system. To classify voluntary and non-voluntary blink, we used the double blink for command of the speller. The online speller experiment result with six healthy subjects shows that mean accuracy is 98.96% and letter per minute (LPM) is 4.73, which are better result by comparison with conventional P300 or auditory brain-computer interface (BCI) paradigm. The result of the experiment demonstrates the possibility of applying the proposed system as a communication method for the LIS patients.

A 4×32-Channel Neural Recording System for Deep Brain Stimulation Systems

  • Kim, Susie;Na, Seung-In;Yang, Youngtae;Kim, Hyunjong;Kim, Taehoon;Cho, Jun Soo;Kim, Jinhyung;Chang, Jin Woo;Kim, Suhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권1호
    • /
    • pp.129-140
    • /
    • 2017
  • In this paper, a $4{\times}32$-channel neural recording system capable of acquiring neural signals is introduced. Four 32-channel neural recording ICs, complex programmable logic devices (CPLDs), a micro controller unit (MCU) with USB interface, and a PC are used. Each neural recording IC, implemented in $0.18{\mu}m$ CMOS technology, includes 32 channels of analog front-ends (AFEs), a 32-to-1 analog multiplexer, and an analog-to-digital converter (ADC). The mid-band gain of the AFE is adjustable in four steps, and have a tunable bandwidth. The AFE has a mid-band gain of 54.5 dB to 65.7 dB and a bandwidth of 35.3 Hz to 5.8 kHz. The high-pass cutoff frequency of the AFE varies from 18.6 Hz to 154.7 Hz. The input-referred noise (IRN) of the AFE is $10.2{\mu}V_{rms}$. A high-resolution, low-power ADC with a high conversion speed achieves a signal-to-noise and distortion ratio (SNDR) of 50.63 dB and a spurious-free dynamic range (SFDR) of 63.88 dB, at a sampling-rate of 2.5 MS/s. The effectiveness of our neural recording system is validated in in-vivo recording of the primary somatosensory cortex of a rat.

단일 채널에서 블라인드 음원분리를 통한 하이브리드 BCI시스템 최적화 (The Optimization of Hybrid BCI Systems based on Blind Source Separation in Single Channel)

  • 양 다린;트렁 하우 뉘엔;김종진;정완영
    • 융합신호처리학회논문지
    • /
    • 제19권1호
    • /
    • pp.7-13
    • /
    • 2018
  • 현재의 연구에서는 소음을 제거하기 위해 블라인드 소스 분리(BSS)접근 방식에 의해 최적화된 두뇌-컴퓨터 인터페이스(BCI)를 제안했다. 모터 이미지(MI)신호와 정상 상태 시각적 제거 전위(SSVEP)신호는 신호 대 잡음비(SNR)의 증가로 인해 쉽게 검출되었다. 또한, MI와 SSVEP사이의 조합은 일반적으로 현재 BCI에서 생성되는 명령 수를 증가시킬 수 있다. 현재 시스템은 계산 시간을 줄이고 BCI를 실제 용도에 가깝게 하기 위해 단일 채널 EEG신호를 사용했다. 또한, 복잡한 신경 네트워크(CNN)가 다중 클래스 분류 모델로 사용되었다. 우리는 비 MS/BCI와 BBS/BCI사이의 정확성 측면에서 성능을 평가했다. 결과적으로 BBS+BCI의 정확도는 비 BBS+BCI의 정확도보다 $16.15{\pm}25.12%$더 높은 수준에 도달했다. 사용하지 않을 때보다 BBS를 사용함으로써 전반적으로 제안된 BCI시스템은 비교적 정확한 다차원 제어 애플리케이션에 적용될 가능성을 입증했다.

서브 밴드 CSP기반 FLD 및 PCA를 이용한 동작 상상 EEG 특징 추출 방법 연구 (A Method of Feature Extraction on Motor Imagery EEG Using FLD and PCA Based on Sub-Band CSP)

  • 박상훈;이상국
    • 정보과학회 논문지
    • /
    • 제42권12호
    • /
    • pp.1535-1543
    • /
    • 2015
  • 뇌-컴퓨터 인터페이스는 사용자의 뇌전도(Electroencephalogram: EEG)를 획득하여 생각만으로 기계를 제어하거나 신체장애를 가진 사람에게 손 또는 발과 같은 신체를 대신하여 의사 전달 수단으로 사용될 수 있다. 본 논문에서는 동작 상상 EEG를 분류하기 위해 Sub-Band Common Spatial Pattern(SBCSP)를 기반으로 필터 선택을 하지 않는 특징 추출 방법에 대해 연구한다. 4~40Hz의 동작 상상 신호를 4Hz 대역마다 나눈 9개의 서브 밴드에 각각 CSP를 적용한다. 이후 Fisher's Linear Discriminant(FLD)를 사용하여 도출된 값들을 결합한 FLD 점수 벡터에 차원 축소를 위한 Principal Component Analysis(PCA)를 적용하여 클래스 구분을 위한 최적의 평면에 특징을 투영한다. 데이터베이스는 BCI CompetitionIII dataset IVa(2 클래스: 오른손 다리)를 이용하며, 추출된 특징은 Least Squares Support Vector Machine(LS-SVM)의 입력으로 사용된다. 제안된 방법의 성능은 $10{\times}10$ fold cross-validation을 이용하여 분류 정확도로 나타낸다. 본 논문에서 제안하는 방법은 피험자 'aa', 'al', 'av', 'aw', 'ay'에 대하여 각각 $85.29{\pm}0.93%$, $95.43{\pm}0.57%$, $72.57{\pm}2.37%$, $91.82{\pm}1.38%$, $93.50{\pm}0.69%$의 분류 정확도를 보였다.

뇌신경과학 연구 및 기술에 대한 민사법적 대응 (Neurotechnologies and civil law issues)

  • 김수정
    • 의료법학
    • /
    • 제24권2호
    • /
    • pp.147-196
    • /
    • 2023
  • 오늘날에는 기술의 발전으로 인간의 뇌에 직접 자극을 가하여 질병을 치료하거나 뇌파를 통해 직접 기계를 조정하는 것이 가능해졌다. 이러한 뇌신경과학기술은 비침습적으로 이루어질 수도 있으나 적어도 현재까지는 뇌에 직접 전극이나 마이크로칩을 이식하는 침습적 방법이 필요한 자극을 더 정확하게 가하거나 뇌파를 더 정밀하게 측정할 수 있다. 뇌심부자극술(DBS)의 경우 파킨슨병, 본태성진전증에 대해 안정적인 치료방법으로 인정받고 있으며, 그 외 알츠하이머나 우울증 등에도 활용할 수 있는지 연구가 진행중이다. 뇌-컴퓨터 인터페이스(BCI)의 경우 임상단계이지만 신경이 손상되어 신체를 움직이지 못하는 사람들의 신체기능을 대체하거나 재활치료를 지원하는 역할을 할 것으로 기대되고 있다. 문제는 이러한 침습적 뇌신경과학기술을 필요로 하는 사람들의 상당수는 질병 또는 신경 손상으로 인해 판단능력이 손상되어 있거나 의사표시를 제대로 할 수 없는 사람들인데 반해, 이 기술들을 이용한 시술은 고도의 침습적인 시술이어서 반드시 환자 본인의 동의를 필요로 한다는 것이다. 특히 뇌신경과학기술이 아직 임상시험단계에 머물러 있는 영역에서는 위험은 그만큼 커지고 이익은 불확실하기 때문에 이를 고려하여 수술을 받을지 여부를 판단할 수 있도록 더 충분한 설명이 이루어져야 한다. 환자에게 성년후견이 개시되어 있다면 성년후견인이 - 경우에 따라서는 법원의 허가를 받아 - 이 시술에 대한 동의를 대신할 수 있을 것이다. 성년후견이 개시되어 있지 않은 경우 환자의 판단능력이 손상되어 있거나 의사표시를 할 수 없는 경우가 문제이다. 우리 의료 실무에서는 환자가 동의할 수 없는 경우 환자의 보호자에게 동의를 받는 경향이 있지만, 환자의 보호자라는 개념은 우리법상 근거를 찾기 어려운 개념이어서 문제가 있다. 장기적으로는 환자의 배우자나 근친이 보충적으로 환자의 의료행위 동의대행권을 갖도록 법률상 규정하는 편이 타당할 것이다. 뇌신경과학시술을 받은 환자에게 부작용 등 손해가 발생한 경우도 검토를 요한다. 만일 환자에게 수술에 수반되는 위험에 대해 제대로 설명이 되지 않았다면 위자료 청구가 가능하다. 의료과실과 부작용 사이에 인과관계가 있다면 그 부작용에 대해서도 손해배상청구를 할 수 있다. 또한 BCI나 DBS 모두 뇌에 전극이나 마이크로칩등을 이식하고 이를 외부의 컴퓨터를 통해 제어하기 때문에 인체의식형 의료기기가 사용된다. 인체이식형 의료기기에는 제조물책임법이 적용되므로 그 결함으로 인해 부작용이 발생했다고 인정된다면 제조자에 대해서 손해배상을 청구할 수 있다. 최근 우리 의료기기법에는 인체이식형 의료기기 책임보험제도가 시행되어 피해자가 구제를 받을 가능성이 더 강하게 보장된다.