본 연구에서는 현재 건강검진에서 시행되고 있는 다중 CT 검사 시 개인선량계를 이용하여 갑상선, 유방, 생식선의 피폭선량에 대한 선량평가를 시행하였다. 선량평가는 CT 항목 중 Brain, Brain + C-S, Brain + Low lung, Brain + L-S CT 검사 시 갑상선, 유방, 생식선의 위치에 TLD와 EPD를 부착하여 측정하였다. 기기 발생선량인 CTDIvol, DLP를 측정하였다. 연구결과 유효 선량은 일반인 연간 선량한도 1mSv보다 Brain + C-S CT 검사 시 갑상선 TLD 41.7%, EPD 156%, Brain + Low lung CT 검사 시 유방 EPD 10%, Brain + L-S CT 검사 시 생식선 TLD 124.4%, EPD 339.8% 높게 평가되었다. 전체 평균값에 대한 CTDIvol, DLP 분석결과 진단참조수준 보다 C-S CTDIvol 값은 0.6%, Low lung CTDIvol 값은 5.7%, DLP 값은 11.8%, L-S CTDIvol 값은 1.2%로 높게 평가되었다. 환자의 피폭선량 감소를 위해 무분별한 검사를 줄이고, 건강검진에서의 선량한도 설정이 필요하다.
Purpose: There are many patients visited to ED in an alcohol intoxicated state. For these patients, it is difficult to predict by only clinical examination whether he/she would have brain lesion. The purpose of this study is to research whether it is possible to predict brain lesion by only clinical examination findings, with comparing patients with/without actual brain lesions. Methods: A retrospective study was performed at a university hospital for the period 11 months with the medical records. As for the inclusion group, head trauma patients with objectively proved drunk, judging by their blood ethanol concentration, and performed the brain CT were selected. In terms of medical record, Glasgow coma scale (GCS), the presence of neurologic abnormalities, the presence of lesion on brain CT of the patients, were examined. From laboratory results, blood ethanol concentration, platelet count, prothrombin time (PT), activated partial thromboplastin time (aPTT) and glucose concentration were identified. Results: For this study, there were total 80 patients of inclusion group. There was no statistically significant difference in terms of GCS score and neurological examination abnormalities, between the group with brain lesion and the group without brain lesion on brain CT. Conclusion: Alcohol intoxicated patient with head trauma visits the ED, it is not possible to distinguish or determine whether brain lesion exists or not by only clinical findings. In order to check the lesion existence, the image examination, therefore, should be considered and performed.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제35권4호
/
pp.213-220
/
2009
Purpose: The present study was aimed to examine the usefulness of 18F-FDG PET/CT in the evaluation of cervical lymph node metastasis in patients with oral cancer. Materials and methods: Twenty-two patients who underwent neck dissection to treat oral cancer were subjected for examination. The cervical node metastasis was evaluated by means of clinical examination, CT scan, PET, and histologic examination. By comparing the results of each examination modality with those of histologic examination, it's sensitivity, specificity, positive predictive value, and negative predictive value were determined. Results: The oral cancer was more frequent in males with a ratio of 2.14:1. The sixth decade showed the highest incidence in age distribution with mean of $56{\pm}16$. Histologic findings showed that squamous cell carcinoma was the most common (15 patients), and mucoepidermoid carcinoma (3), malignant melanoma (2), and adenoid cystic carcinoma and ghost cell odontogenic carcinoma (1 each), in order. In most cases, wide surgical excision of the primary cancer and neck dissection was performed, followed by reconstruction with free flaps when necessary. When comparing the results of each examination modality with those of the histologic examination, clinical examination showed sensitivity, specificity, positive predictive value, and negative predictive value at 11%, 85%, 33%, and 58%, respectively. CT scans showed at 67%, 77%, 67%, and 77%, while $^{18}F$-FDG PET/CT at 78%, 77%, 70%, and 83%, respectively. Conclusions: These results suggest that PET is more useful, compared with clinical examination and CT scans, in the evaluation of cervical lymph node metastasis in patients with oral cancer.
The purpose of this study was to find the best protocol for balance of image quality and dose in brain CT scan. Images were acquired using dual-source CT and AAPM water phantom, noise and dose were measured, and effective dose was calculated using computer simulation program ALARA(S/W). In order to determine the ratio of image quality and dose by each protocol, FOM (figure of merits) equation with normalized DLP was presented and the result was calculated. judged that the ratio of image quality and dose was excellent when the FOM maximized. Experimental results showed that protocol No. 21(120 kVp, 10 mm, 1.5 pitch) was the best, the organ with the highest effective dose was the brain(33.61 mGy). Among organs with high radiosensitivity, the thyroid gland was 0.78 mGy and breast 0.05 mGy. In conclusion, the optimal parameters and the organ dose in the protocol were also presented from the experiment, It may be helpful to clinicians who want to know the protocol about the optimum state of image quality and dose.
A dog (Chihuahua, 2-year-old, intact female) was referred to us because of cluster seizure. She had history of falling from height few days before presentation. Brain computed tomography (CT) results demonstrated fracture line on right temporal bone and hypodense, edematous changes of the adjacent brain parenchyma on right cerebral parenchyma. Based on history, clinical signs, and diagnostic imaging findings, this patient was diagnosed to traumatic brain injury. After diagnosis, the patient was well controlled with anti-inflammatory drug and anti-epileptic drugs. When 30, 480, and 1260 days after initial brain CT examination, we performed serial brain CT rechecks. This case report describes serial clinical and brain CT findings after traumatic brain injury.
급성 뇌졸중(acute stroke)의 경우 빠른 처치가 이루어지지 않으면 뇌손상으로 인해 평생 장애를 가지고 살아가야 하는 질환이다. 따라서 뇌졸중 환자가 발생할 경우에는 신속한 진단과 치료가 이루어져야 하므로 장시간의 검사를 해야 하는 MRI 보다는 빠른 검사와 3D 구현이 가능한 뇌 관류전산화단층촬영(Brain Perfusion CT)이 널리 활용되고 있다. 그러나 환자에게 많은 방사선 피폭이 이루어질 수 있기 때문에 저선량(low dose) 기법을 사용하여 영상을 획득하게 된다. 이로 인해 촬영된 영상의 질 저하가 유발되며, 특히 가우시안노이즈의 영향을 크게 받아 정확한 혈관 영상의 확인을 저해한다. 본 연구에서는 관류전산화단층촬영을 통해 얻어진 동적 CT 데이터에 시공간 분석 기법을 적용하여 진단 영상의 질을 향상시키고자 한다. 특히, 가우시안노이즈를 제거하기 위해서 선형 특징 축출 방법 중 하나인 주성분 분석 기법을 적용하여 분석하였으며, 그 결과 시공간 특징에 따른 각각의 관류 영상 성분을 축출한 경우 뇌-혈관 영상뿐만 아니라 뇌-실질 영상의 질이 향상됨을 가시적으로 확인할 수 있었다. 새롭게 시도된 시공간 기반 영상기법이 향후 급성 뇌졸중 진단뿐만 아니라 다양한 시계열 정보가 포함된 뇌질환 진단 영상분석에 활용된다면, 임상 진단의 질 향상에 도움이 될 것이라 기대한다.
To demonstrate the clinical usefulness of electroencephalography (EEG) and factors increasing the usefulness of EEG, the authors evaluated each relationship between EEG related factors and clinical variables, and neuroimaging studies (CT and MRI)-related factors, and factors which are related with routine neurological examination for 207 patients who had been evaluated with both of EEG and neuroimaging study(CT or/and MRI). The results were as follows: 1) Abnormality of EEG findings had significant relationships with chief complaints, diagnosis, medication use, seizure attack, pathological reflex, and level of consciousness. However there were no significant correlations between abnormality of EEG findings and neuroimaging studies (CT and MRI)- related factors. 2) Laterality of EEG findings had significant relationships with abnormality, laterality, and focality of CT findings, and also with abnormality of MRI findings. But there were no significant correlations between laterality of EEG findings and clinical variables, and neurological examination-related factors. 3) Anterior-posterior distribution of EEG findings was significantly related with medication use. 4) Focality of EEG findings had significant relationships with sex, sensory dysfunction sign, and cerebellar dysfunction sign. But there were no significant correlations between focality of EEG findings and neuroimaging studies(CT and MRI) related factors. 5) Abnormal EEG pattern had significant correlations with various factors, such as age, chief complaints, duration from onset of symptom to taking MRI, seizure attack, abnormality and nature of lesion in CT findings, cortical atrophy in MRI findings, motor dysfunction sign, sensory dysfunction sign, and pathological reflex. 6) With abnormality on sleep activation, age, age of onset, seizure attack, ventricular enlargement in CT findings, and abnormality of MRI findings were significantly correlated. 7) With abnormality on hyperventilation activation, duration of illness and laterality of MRI findings were significantly correlated. Above results may suggest that abnormality of EEG findings is more closely related with functional change of the brain than structural changes of the brain and laterality of EEG findings is vice versa. And also that medication use has an influence on anterior versus posterior distribution of EEG findings and focality of EEG findings is not related with structural changes of the brain. Activation with sleep may be effective to show age differences and provocation of seizure activity and hyperventilation may be effective to detect the abnormal EEG findings by cerebrovascular insufficiency.
Objective: To evaluate the usefulness of the ventricular volume percentage quantified using three-dimensional (3D) brain computed tomography (CT) data for interpreting serial changes in hydrocephalus. Materials and Methods: Intracranial and ventricular volumes were quantified using the semiautomatic 3D threshold-based segmentation approach for 113 brain CT examinations (age at brain CT examination ≤ 18 years) in 38 patients with hydrocephalus. Changes in ventricular volume percentage were calculated using 75 serial brain CT pairs (time interval 173.6 ± 234.9 days) and compared with the conventional assessment of changes in hydrocephalus (increased, unchanged, or decreased). A cut-off value for the diagnosis of no change in hydrocephalus was calculated using receiver operating characteristic curve analysis. The reproducibility of the volumetric measurements was assessed using the intraclass correlation coefficient on a subset of 20 brain CT examinations. Results: Mean intracranial volume, ventricular volume, and ventricular volume percentage were 1284.6 ± 297.1 cm3, 249.0 ± 150.8 cm3, and 19.9 ± 12.8%, respectively. The volumetric measurements were highly reproducible (intraclass correlation coefficient = 1.0). Serial changes (0.8 ± 0.6%) in ventricular volume percentage in the unchanged group (n = 28) were significantly smaller than those in the increased and decreased groups (6.8 ± 4.3% and 5.6 ± 4.2%, respectively; p = 0.001 and p < 0.001, respectively; n = 11 and n = 36, respectively). The ventricular volume percentage was an excellent parameter for evaluating the degree of hydrocephalus (area under the receiver operating characteristic curve = 0.975; 95% confidence interval, 0.948-1.000; p < 0.001). With a cut-off value of 2.4%, the diagnosis of unchanged hydrocephalus could be made with 83.0% sensitivity and 100.0% specificity. Conclusion: The ventricular volume percentage quantified using 3D brain CT data is useful for interpreting serial changes in hydrocephalus.
두경부(Head & Neck) CT(Computed Tomography)검사에서 환자가 받는 피폭선량 측정을 위하여 인체등가물질로 만든 Rando phantom과 유리선량계를 이용하여 두경부 검사에 따른 환자의 흡수선량의 변화를 실험을 통하여 연구하였다. 인체두부모형을 안와신경(optic nerve), 교뇌(pons), 소뇌(cerebellum), 갑상선(thyroid)으로 나누어, 두경부(Head & Neck) 부위의 검사를 단독검사(Brain, 3D Facial, Temporal, Brain Angiography, 3D Cervical Spine)와 복합검사(Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spin+Angiography)로 구분하여 유효선량의 변화를 실험한 후 결과를 측정하였다. 단순 Brain검사와 Brain Angio검사에는 optic nerve에 유효 선량이 높게 분석되었으며, 또한 Temporal검사에는 Pons에, 3D facial 검사와 3D Cervical Spin검사에는 thyroid의 유효선량 값이 높게 나타났다. 복합적으로 이루어는 검사 중 두경부의 Brain+Brain Angio의 검사는 cerebellum의 부위, Brain+3D facial 검사와 Brain+3D Cervical Spin의 복합검사는 thyroid의 부위, Brain+Temporal의 검사에는 pon's 부위 유효 선량 값이 높게 나타났다. Brain +3D facial +Temporal의 복합검사와 Brain+3D Cervical Spin+Angio의 복합검사는 thyroid의 부위에 유효 선량 값이 높게 분석 되었다. 본 연구 결과 Brain+3D Cervical Spin+Brain Angio 복합검사인 경우의 유효 선량은 2.51858 mSv로 일반인의 연간 유효선량한도 1 mSv의 피폭을 초과하는 결과가 나왔다. 또한, Brain 단순 검사 시 optic nerve는 0.31312 mSv의 유효선량으로 향후 방사선학 검사가 이루어질 경우, 두경부의 일반인의 연간 유효선량을 훨씬 초과할 것이라 사료된다. 따라서 진료의 필요성에 의해서 시행되는 CT검사일지라도 질환 병변의 특성에 맞게 CT촬영조건 변화를 주면서 환자의 피폭선량을 최소한으로 할 수 있는 다양한 검사방법의 연구가 필요하다고 사료된다.
전산화 단층촬영검사 시 환자가 받는 피폭선량과 장치 이용 실태를 파악하기 위한 목적으로 대한병원협회에 등록된 전국의 278개 의료기관에 설문지를 발송하여 설문에 응답한 161개 의료기관의 자료를 분석하여 다음과 같은 결과를 얻었다. 1. 검사의 부위별 촬영분포는 Brain(40.7%), Abdomen(27.8%), Chest(15.7%), Spine(4.8%), Pelvis(4.1%), PNS(3.2%) Facial bone(2.5%), Extremity(1.1%)등으로 Brain검사가 가장 많았다. 2. 검사 부위별 선량지수에 대한 통계는 성인의 경우 Brain 38.0mGy, Chest 10.1mGy, Abdomen 12.0mGy, Pelvis 13.2mGy, PNS 27.5mGy, Facial bone 28.6mGy, Spine 26.0mGy, Extremity 13.5mGy이었고, 유아의 경우 Brain 13.6mGy, Abdomen 6.2mGy 이었다. 3. 검사부위별 촬영조건에 대한 통계는 관전압 $100kVp{\sim}120kVp$, 관전류 $100mA{\sim}250mA$, 조사시간은 1초${\sim}$2초를 가장 많이 사용하고 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.