A study on the utilization of CT equipments |
Cho, Pyong-Kon
(Dept. of Diagnostic Radiology, Korea University Medical Center)
Oh, Yu-Whan (Dept. of Diagnostic Radiology, Korea University Medical Center) Kim, Sung-Soo (Dept. of Radiologic Technology, College of Singu) Choi, Jong-Hak (Dept. of Radiologic Technology, College of Health Sciences, Korea University) Kim, You-Hyun (Dept. of Radiologic Technology, College of Health Sciences, Korea University) |
1 | IAEA, International basic sagety standards for protection against ionizing radiation and the safety of radiation source. 279-280, EADA Safety Series No.115, Vienna(1996) |
2 | S. Suzuki, T. Orito, Koga, et al., Changes in x-ray diagnostic technology and patient exposure dose comparison with 1973 and 1979. A Monthly Journal of Medical Imaging and Information 22(6), 359-363(1990) |
3 | T. B. Shope, R. M. Gange, and G. C. Johnson, 'A method for describing the doses delivered by transmission x-ray computed tomography', Med. Phys.8, 488(1981) |
4 | D. J. Brenner, C. D. EUiston, E. J. Hall, et al, Estimate risks of radiation induced fatal cancer from pediatric CT. AJR 176, 289-296(2001) DOI ScienceOn |
5 | IAEA Guidance level(2002) |
6 | G. Bongartz, S. J. Golding, A. G. Jurik, M. Leonardi, E. v. P. van Meerten, J. Geleijns, K A. Jessen, W. Panzer, P. C. Shrimpton, G. Tosi et al., European guidelines on quality criteria for computed tomography. EUR 16262 EN |
7 | 조평곤, 전산화 단층촬영장치의 정도관리에 관한 연구 석사학위논문 고려대학교 교육대학원(2001) |
8 | Robert L. Mini, et al., Radiation exposure of patiants who undergo CT of the trunk. Radiology Volume 195 No.2, 557-562(1995) PUBMED |
9 | 최종학 외, 의료방상선 생물학, 신광출판사(2004) |
10 | K.S. Pentiow, 'Dosimetry in computed tomography', Chapter 124, Volume Five Radiology of the Skull and Brain, Technical Aspect of Computed Tomography, T.H. Newton and D.G. Potts, Eds., C.V. Mosby, St. Louis(1981) |
11 | J. Anthony Seibert, Gray T. Barnes, Robert G. Gould, et al., Specification, Acceptance testing and quality control of diagnostic X-ray imaging equipment. Medical physics monograph No. 20, 899-936(1991) |
12 | 'Operating Instructions Somatom Plus CT, Dose and Imaging Performance Information'. Siemens Aktiengesellschaft(1990) |
13 | National Institute of Radiological Science (supervisr), Report 1998 to the general Meeting of the International Science Committee on the Source, Effect and Risk of Radiation-Effect of Atomic Radiation Attachment C(exposure from the medical use of radiation). Jitsugyokoho, Tokyo. 265-334(1990) |
14 | T. Orito, Investigation of accrual situation of radiological techniques to take measures for patient exposure dose reduction. Jpn. J. Radiological technology 32, 34-39(1974) |
15 | T. Orito, S. Sanada, S. Koga, et al., Changes in x-ray diagnostic technology and patient exposure dose comparison with 1973 and 1979. A Monthly Journal of Medical Imaging and Information 12(6), 325-327(1980) |
16 | T. B. Shope, T. J. Morgan, C. K Showalter, K. S. Pentiow, L. N. Rothenberg, D. R White, and R D. Speller, 'Radiation dosimetry survey of computed tomography systems from ten manufacturers', Br. J. Radiol. 55, 60(1982) |