• Title/Summary/Keyword: Brain CT Examination

Search Result 73, Processing Time 0.019 seconds

Exposure Dose of Thyroid, Breast, and Sexual Gland using a Personal Dosimeter in Multiple CT Examinations (다중 CT 검사 시 개인선량계를 이용한 갑상선, 유방, 생식선의 피폭선량)

  • Kim, Hae-Suk;Kim, Jang-Oh;Lee, Yoon-Ji;Heo, Sung-Hoe;Lee, Chang-Ho;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.345-351
    • /
    • 2020
  • In this study, a dose assessment was conducted on the exposure dose of thyroid, breast and sexual gland using a personal dosimeter in multiple CT examinations currently being conducted in health examinations. The dose assessment was measured by attaching TLD and EPD to the locations of the thyroid, breast and sexual gland during CT examinations of Brain, Brain + C-S, Brain + Low lung, Brain + L-S among CT items. The generated dose of equipment, CTDIvol and DLP, was measured. The study found that effective doses were rated 41.7% higher for thyroid TLD in Brain + C-S CT examinations than for the general public, 156% higher for EPD, 10% for breast EPD in Brain + Low Lung CT examinations, 124.4% higher for reproductive TLD and 339.8% higher for Brain + L-S CT examinations. The CTDIvol and DLP analysis results showed that C-S CTDIvol values were higher than the diagnostic reference levels at 0.6%, Low Lung CTDIvol values at 5.7%, DLP values at 11.8% and L-S CTDIvol values at 1.2%. In order to reduce the exposure dose of patients, indiscriminate examination is reduced and dose limit setting is needed in health examination.

The Significance of Clinical Examination for Brain Lesion Differentiation of Patients with Head Trauma after Alcohol Intoxication

  • Jung, Yoon Hyun;Jeong, Dong Kil;Lee, Jung Won;Moon, Hyung Jun;Choi, Jae Hyung;Song, Jun Hwan
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.99-104
    • /
    • 2016
  • Purpose: There are many patients visited to ED in an alcohol intoxicated state. For these patients, it is difficult to predict by only clinical examination whether he/she would have brain lesion. The purpose of this study is to research whether it is possible to predict brain lesion by only clinical examination findings, with comparing patients with/without actual brain lesions. Methods: A retrospective study was performed at a university hospital for the period 11 months with the medical records. As for the inclusion group, head trauma patients with objectively proved drunk, judging by their blood ethanol concentration, and performed the brain CT were selected. In terms of medical record, Glasgow coma scale (GCS), the presence of neurologic abnormalities, the presence of lesion on brain CT of the patients, were examined. From laboratory results, blood ethanol concentration, platelet count, prothrombin time (PT), activated partial thromboplastin time (aPTT) and glucose concentration were identified. Results: For this study, there were total 80 patients of inclusion group. There was no statistically significant difference in terms of GCS score and neurological examination abnormalities, between the group with brain lesion and the group without brain lesion on brain CT. Conclusion: Alcohol intoxicated patient with head trauma visits the ED, it is not possible to distinguish or determine whether brain lesion exists or not by only clinical findings. In order to check the lesion existence, the image examination, therefore, should be considered and performed.

USEFULNESS OF $^{18}F$-FDG PET/CT IN THE EVALUATION OF CERVICAL LYMPH NODE METASTASIS IN PATIENTS WITH ORAL CANCER (구강암 환자에서 $^{18}F$ FDG-PET/CT의 경부 림프절 전이 평가 유용성)

  • Yu, Min-Gi;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.213-220
    • /
    • 2009
  • Purpose: The present study was aimed to examine the usefulness of 18F-FDG PET/CT in the evaluation of cervical lymph node metastasis in patients with oral cancer. Materials and methods: Twenty-two patients who underwent neck dissection to treat oral cancer were subjected for examination. The cervical node metastasis was evaluated by means of clinical examination, CT scan, PET, and histologic examination. By comparing the results of each examination modality with those of histologic examination, it's sensitivity, specificity, positive predictive value, and negative predictive value were determined. Results: The oral cancer was more frequent in males with a ratio of 2.14:1. The sixth decade showed the highest incidence in age distribution with mean of $56{\pm}16$. Histologic findings showed that squamous cell carcinoma was the most common (15 patients), and mucoepidermoid carcinoma (3), malignant melanoma (2), and adenoid cystic carcinoma and ghost cell odontogenic carcinoma (1 each), in order. In most cases, wide surgical excision of the primary cancer and neck dissection was performed, followed by reconstruction with free flaps when necessary. When comparing the results of each examination modality with those of the histologic examination, clinical examination showed sensitivity, specificity, positive predictive value, and negative predictive value at 11%, 85%, 33%, and 58%, respectively. CT scans showed at 67%, 77%, 67%, and 77%, while $^{18}F$-FDG PET/CT at 78%, 77%, 70%, and 83%, respectively. Conclusions: These results suggest that PET is more useful, compared with clinical examination and CT scans, in the evaluation of cervical lymph node metastasis in patients with oral cancer.

Noise and Image Quality Analysis of Brain CT Examination (두부 CT검사에서의 노이즈 및 화질분석)

  • Choi, Seok-yoon;Im, In-chul
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.279-284
    • /
    • 2019
  • The purpose of this study was to find the best protocol for balance of image quality and dose in brain CT scan. Images were acquired using dual-source CT and AAPM water phantom, noise and dose were measured, and effective dose was calculated using computer simulation program ALARA(S/W). In order to determine the ratio of image quality and dose by each protocol, FOM (figure of merits) equation with normalized DLP was presented and the result was calculated. judged that the ratio of image quality and dose was excellent when the FOM maximized. Experimental results showed that protocol No. 21(120 kVp, 10 mm, 1.5 pitch) was the best, the organ with the highest effective dose was the brain(33.61 mGy). Among organs with high radiosensitivity, the thyroid gland was 0.78 mGy and breast 0.05 mGy. In conclusion, the optimal parameters and the organ dose in the protocol were also presented from the experiment, It may be helpful to clinicians who want to know the protocol about the optimum state of image quality and dose.

A Case of Traumatic Brain Injury in a Chihuahua Dog: Serial Clinical and Computed Tomographic Findings (치와와에서 발생한 외상적 뇌손상 증례; 연속적인 임상적 및 전산화 단층영상 소견)

  • Lee, Hee-Chun;Won, Jin-Hee;Moon, Jong-Hyun;Jung, Hae-Won;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.329-332
    • /
    • 2014
  • A dog (Chihuahua, 2-year-old, intact female) was referred to us because of cluster seizure. She had history of falling from height few days before presentation. Brain computed tomography (CT) results demonstrated fracture line on right temporal bone and hypodense, edematous changes of the adjacent brain parenchyma on right cerebral parenchyma. Based on history, clinical signs, and diagnostic imaging findings, this patient was diagnosed to traumatic brain injury. After diagnosis, the patient was well controlled with anti-inflammatory drug and anti-epileptic drugs. When 30, 480, and 1260 days after initial brain CT examination, we performed serial brain CT rechecks. This case report describes serial clinical and brain CT findings after traumatic brain injury.

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

The Clinical Usefulness of Electroencephalography : Comparison of Findings Electroencephalography with Findings of Brain Computed Tomography and Magnetic Resonance Imaging (뇌파의 임상적 유용성 : 뇌파소견과 뇌전산화 단층촬영 검사 및 뇌자기공명 영상검사 소견을 비교하여)

  • Kang, Dong-Woo;Lee, Young-Ho;Choi, Young-Hee;Chung, Young-Cho
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.1-17
    • /
    • 1996
  • To demonstrate the clinical usefulness of electroencephalography (EEG) and factors increasing the usefulness of EEG, the authors evaluated each relationship between EEG related factors and clinical variables, and neuroimaging studies (CT and MRI)-related factors, and factors which are related with routine neurological examination for 207 patients who had been evaluated with both of EEG and neuroimaging study(CT or/and MRI). The results were as follows: 1) Abnormality of EEG findings had significant relationships with chief complaints, diagnosis, medication use, seizure attack, pathological reflex, and level of consciousness. However there were no significant correlations between abnormality of EEG findings and neuroimaging studies (CT and MRI)- related factors. 2) Laterality of EEG findings had significant relationships with abnormality, laterality, and focality of CT findings, and also with abnormality of MRI findings. But there were no significant correlations between laterality of EEG findings and clinical variables, and neurological examination-related factors. 3) Anterior-posterior distribution of EEG findings was significantly related with medication use. 4) Focality of EEG findings had significant relationships with sex, sensory dysfunction sign, and cerebellar dysfunction sign. But there were no significant correlations between focality of EEG findings and neuroimaging studies(CT and MRI) related factors. 5) Abnormal EEG pattern had significant correlations with various factors, such as age, chief complaints, duration from onset of symptom to taking MRI, seizure attack, abnormality and nature of lesion in CT findings, cortical atrophy in MRI findings, motor dysfunction sign, sensory dysfunction sign, and pathological reflex. 6) With abnormality on sleep activation, age, age of onset, seizure attack, ventricular enlargement in CT findings, and abnormality of MRI findings were significantly correlated. 7) With abnormality on hyperventilation activation, duration of illness and laterality of MRI findings were significantly correlated. Above results may suggest that abnormality of EEG findings is more closely related with functional change of the brain than structural changes of the brain and laterality of EEG findings is vice versa. And also that medication use has an influence on anterior versus posterior distribution of EEG findings and focality of EEG findings is not related with structural changes of the brain. Activation with sleep may be effective to show age differences and provocation of seizure activity and hyperventilation may be effective to detect the abnormal EEG findings by cerebrovascular insufficiency.

  • PDF

Hydrocephalus: Ventricular Volume Quantification Using Three-Dimensional Brain CT Data and Semiautomatic Three-Dimensional Threshold-Based Segmentation Approach

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.435-441
    • /
    • 2021
  • Objective: To evaluate the usefulness of the ventricular volume percentage quantified using three-dimensional (3D) brain computed tomography (CT) data for interpreting serial changes in hydrocephalus. Materials and Methods: Intracranial and ventricular volumes were quantified using the semiautomatic 3D threshold-based segmentation approach for 113 brain CT examinations (age at brain CT examination ≤ 18 years) in 38 patients with hydrocephalus. Changes in ventricular volume percentage were calculated using 75 serial brain CT pairs (time interval 173.6 ± 234.9 days) and compared with the conventional assessment of changes in hydrocephalus (increased, unchanged, or decreased). A cut-off value for the diagnosis of no change in hydrocephalus was calculated using receiver operating characteristic curve analysis. The reproducibility of the volumetric measurements was assessed using the intraclass correlation coefficient on a subset of 20 brain CT examinations. Results: Mean intracranial volume, ventricular volume, and ventricular volume percentage were 1284.6 ± 297.1 cm3, 249.0 ± 150.8 cm3, and 19.9 ± 12.8%, respectively. The volumetric measurements were highly reproducible (intraclass correlation coefficient = 1.0). Serial changes (0.8 ± 0.6%) in ventricular volume percentage in the unchanged group (n = 28) were significantly smaller than those in the increased and decreased groups (6.8 ± 4.3% and 5.6 ± 4.2%, respectively; p = 0.001 and p < 0.001, respectively; n = 11 and n = 36, respectively). The ventricular volume percentage was an excellent parameter for evaluating the degree of hydrocephalus (area under the receiver operating characteristic curve = 0.975; 95% confidence interval, 0.948-1.000; p < 0.001). With a cut-off value of 2.4%, the diagnosis of unchanged hydrocephalus could be made with 83.0% sensitivity and 100.0% specificity. Conclusion: The ventricular volume percentage quantified using 3D brain CT data is useful for interpreting serial changes in hydrocephalus.

Effective Dose Determination From CT Head & Neck Region (두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정)

  • Yun, Jae-Hyeok;Lee, Kwang-Weon;Cho, Young-Ki;Choi, Ji-Won;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 2011
  • In this study, we present the measurements of effective dose from CT of head & neck region. A series of dose measurements in anthropomorphic Rando phantom was conducted using a radio photoluminescent glass rod dosimeter to evaluate effective doses of organs of head and neck region from the patient. The experiments were performed with respect to four anatomic regions of head & neck: optic nerve, pons, cerebellum, and thyroid gland. The head & neck CT protocol was used in the single scan (Brain, 3D Facial, Temporal, Brain Angiography and 3D Cervical Spine) and the multiple scan (Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spine+Brain Angiography). The largest effective dose was measured at optic nerve in Brain CT and Brain Angiography. The largest effective dose was delivered to the thyroid grand in 3D faical CT and 3D cervical spine, and to the pons in Temporal CT. In multiple scans, the higher effective dose was measured in the thyroid grand in Brain+3D Facial, Brain+3D Cervical Spine, Brain+3D Facial+Temporal and Brain+3D Cervical Spine+Brain Angiography. In addition, the largest effective dose was delivered to the cerebellum in Brain CT+Brain Angiography CT and higher effective dose was delivered to the pons in Brain+Temporal CT. The results indicate that in multiple scan of Brain+3D Cervical Spine+Brain Angiography, effective dose was 2.52 mSv. This is significantly higher dose than the limitation of annual effective dose of 1 mSv. The effective dose to the optic nerve was 0.31 mSv in Brain CT, which shows a possibility of surpassing the limitation of 1 mSv by furthre examination. Therefore, special efforts should be made in clinical practice to reduce dose to the patients.

A study on the utilization of CT equipments (전산화 단층촬영 장치의 이용 실태에 대한 조사)

  • Cho, Pyong-Kon;Oh, Yu-Whan;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.9-15
    • /
    • 2005
  • This study was conducted to investigate the patient exposure dose during a CT examination and the present position in utilization of the CT equipments. To this end Questionnaire were sent out to 278 medical facilities registered at Korea Hospital Association and replies of 161 medical facilities were analyzed. The results were as follows ; 1) The distribution of CT examination was. Brain 40.7%, Abdomen 27.8%, Chest 15.7%, Spine 4.8%, Pelvis 4.1%, PNS 3.2%, Facial bone 2.5% and Extremity 1.1% respectively. 2) The statistics for dose index according to each part of examination were Brain 38.0mGy, Abdomen 12.0mGy for adults : Brain 13.6mGy, Abdomen 6.2mGy for infant. Our surveyed dose index appeared lower than the IAEA recommends. 3) Most medical facilities have selected the parameters for radiographic exposure in the range of $100{\sim}120kVp,\;100{\sim}250mA\;and\;1{\sim}2$ seconds.