고강도 강관파이프 스트러트 흙막이공법 사례연구 (Case Study of Braced Wall System with High-strength Steel Pipe Strut)

  • 신재민;박현영;주진규;신윤석;김광희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.19-20
    • /
    • 2012
  • According to develop urban area, the depth and floor area of basement tend to become deeper and larger. Excavation work for basement floor work is very important because its cost take 20% of total construction cost. Therefore, many studies of developing retaining wall system have performed for feasibility and safety in deep excavation work. In this study, new supporting system used high-strength pipe for retaining wall is introduced to reduce the construction cost and improve the safety and constructability by analyzing case study.

  • PDF

개선된 탄소성 해석을 이용한 버팀지지 흙막이벽의 거동비교 (Comparison of Displacement of the Braced Retaining Wall by Developed Elasto-Plastic Analysis)

  • 신진환;김동신
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.112-118
    • /
    • 2004
  • Recently, when being constructed the large structures, the deep excavations have performed to utilize the underground space. As the ground excavation is deeper, the damage of the adjacent structure and the ground is frequently occurred. the Analysis of the retaining structures is necessary to safety of the excavation works. There are many methods such as elasto-plastic theory, FEM, and FDM to analyze the displacement of the retaining structure. In this thesis, GEBA-1 program by the Nakamura-Nakajawa elasto-plastic method was developed. The lateral displacement of the wall was analyzed by the developed program GEBA-1, SUNEX, and EXCAD, and compared with the measured displacement bye the Inclinometer. The monitored fields were three excavation work site in S-I, S-II, and S-III area. Excavation method of each site is braced retaining wall using H-pile. Excavation depth is 14m, 14m, and 8.2m.

Shaking Table Test and Analysis of Reinforced Concrete Frame with Steel Shear Wall with Circular Opening and Slit Damper

  • Shin, Hye-Min;Lee, Hee-Du;Shin, Kyung-Jae
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1420-1430
    • /
    • 2018
  • Earthquakes of 5.8 and 5.4 Richter scale recently occurred one after another in Korea, changing the Korean peninsula from an earthquake safe zone but 'earthquake danger zone'. Therefore, seismic reinforcements must expand to include structures with low seismic resistance in order to prepare for earthquakes on a larger scale in the future. This study investigated the performances of various seismic reinforcement systems such as X-braced steel rod reinforcement, steel shear wall with circular opening reinforcement, and slit damper reinforcement using shaking table test and computational analyses of seismic data in order to establish a proper seismic reinforcement plan. These three seismic reinforcement systems could increase the stiffness and strength of existing structures and reduce maximum drift ratio in the event of an earthquake.

Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls

  • Beiraghi, Hamid
    • Structural Engineering and Mechanics
    • /
    • 제72권4호
    • /
    • pp.443-454
    • /
    • 2019
  • In order to reduce the residual drift of a structure in structural engineering field, a combined structural system (dual) consisting of steel buckling-restrained braced frame (BRBF) along with shear wall is proposed. In this paper, BRBFs are used with special reinforced concrete shear walls as combined systems. Some prototype models of the proposed combined systems as well as steel BRBF-only systems (without walls) are designed according to the code recommendations. Then, the nonlinear model of the systems is prepared using fiber elements for the reinforced concrete wall and appropriate elements for the BRBs. Seismic responses of the combined systems subjected to ground motions at maximum considered earthquake level are investigated and compared to those obtained from BRBFs. Results showed that the maximum residual inter-story drift from the combined systems is, on average, less than half of the corresponding value of the BRBFs. In this research, mean of absolute values of the maximum inter-story drift ratio demand obtained from combined systems is less than the 3% limitation, while this criterion has not been fulfilled by BRBF systems.

탄소성 해석프로그램에 의한 버팀지지 흙막이벽의 변위 비교 (Displacement Comparison of a Braced Retaining Wall by Elasto-Plastic Analysis Program)

  • 신방웅;김상수;오세욱;김동신
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.395-402
    • /
    • 2000
  • Recently, the deep excavations have been peformed to utilize the under ground space. As the ground excavation is deeper, the damage of the adjacent structure and the ground occurs frequently. The analysis of the retaining structures is necessary to the safety of the excavation works. There are many methods such as elasto-plastic, FEM, and FDM to analyze the displacement of the retaining structure. The elasto-plastic method is generally used in practice. In this thesis, GEBA-1 program by the Nakamura-Nakajawa elasto-plastic method was developed. The program for Windows was used the Visual Basic 6.0, and the Main of the program consists of three subroutines, SUB1, SUB2, and SUB3. The lateral displacement of the wall was analyzed by the developed program GEBA-1, SUNEX, and EXCAD, and compared with the measured displacement by the Inclinometer(at three excavation work sites). The excavation method of each site is braced retaining wall using H-pile. Each excavation depth is 14m, 14m, or 8.2m. The results of the analyses are the followings ① In the multi-layer soil, the lateral displacement by the GEBA-1 and EXCAD which is considering the distribution of the strut load is equal to the measured displacement. Elasto-plasto programs can't consider the change of the ground water in clay. Therefore, the analysis displacement was expected only 20% of the measured wall displacement. ③ At the final excavation step, the maximum lateral displacement of analysis and field occurred 7∼18m at the 85∼92% of the excavation depth. ④ The maximum lateral displacement in clay, as 50mm, occurred on the ground surface.

  • PDF

THE THEORETICAL AND SITE BEHAVIOUR OF A BRACED DIAPHRAGM WALL-A COMPARISON

  • Kim, Hak-Moon
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1990년도 PROCEEDINGS OF THE FIRST KOREA-JAPAN JOINT GEOTECHNICAL SEMINAR ON EXCAVATION and TUNNELING IN URBAN AREAS
    • /
    • pp.111-128
    • /
    • 1990
  • Three numerical analysis carried out for the design of a diaphragm wall were examined by the results of field observation data. Utilizing the wall stiffness, supporting system and construction sequence, the relative merits of those factors on the analysis of diaphragm wall have been investigated and their effects are compared tilth the observed behaviour of the wall. The predicted bending moment and wall displacement by elasto-plastic method agreed well with the observed values. The rigid slab supported system (i.e Top-Down Method) found to be the most effective way of controlling ground movement.

  • PDF

스트랩 브레이스를 갖는 내력벽식 모듈러건축 스틸스터드 벽체의 반복하중에 대한 거동 연구 (Experimental Study on the Cyclic Behavior of Modular Building with Strap Braced Load Bearing Steel Stud Walls)

  • 이두용;조봉호;김태형;하태휴
    • 한국강구조학회 논문집
    • /
    • 제28권6호
    • /
    • pp.415-425
    • /
    • 2016
  • 스틸스터드 내력벽 시스템은 국외에서 중고층형 모듈러 건축에 널리 사용되는 구조형식이다. 국내의 중고층형 모듈러 시스템에 스틸 스터드 벽체를 적용하기 위해서는 내진성능 확보가 필수적이다. 본 연구에서는 스트랩브레이스를 갖는 모듈러 건축 스틸스터드 내력벽 시스템의 횡력저항성능 및 유효강성을 제안하였다. 스트랩 브레이스와 수직외측스터드의 사양을 달리하는 2개의 실물 실험체에 대해 주기하중에 대한 실험을 실시하여 제안된 설계식을 검증하였다. 수직외측스터드의 휨거동을 고려할 수 있는 설계식을 통해 실험체의 공칭강도, 탄성강성, 항복변위 등을 예측하고 실험을 통해 검증하였다. 실험에 의한 최대강도는 예측식 대비 1.11~1.18배 수준으로 평가되었다. 박판의 스트랩 브레이스를 갖는 스트랩 스터드패널은 일반적으로 에너지소산능력이 매우 낮은 것으로 평가되나, 본 연구에서 제안한 수직외측스터드의 유효높이를 줄이고 브레이스의 각도를 낮춘 시스템의 경우 등가점성감쇠비가 최대 9.42% 수준으로 충분한 에너지소산능력이 확보될 수 있음을 확인하였다.

고압분사주입공법에 의한 지반개량사례연구(II) -흙막이벽 배면지반보강 및 차수효과 (Case Studies on Ground Improvement by High Pressure Jet Grouting(II) Effect on the Ground Reinforcement and Cut off of Ground Water Behind Temporary Retaining Walls)

  • 윤중만;홍원표;정형용
    • 한국지반공학회지:지반
    • /
    • 제12권5호
    • /
    • pp.5-16
    • /
    • 1996
  • 지하수위가 높고 느슨한 사질토지반에서 가설흙막이벽을 설치하여 지하굴착공사를 실시할 경우 굴착저면에서 보일링현상이 발생하여 굴착공사 뿐만 아니라 인접구조물에 상당한 피해를 주게 된다. 따라서 최근에는 흙막이벽 배면지반의 강도를 증대시키면서 동시에 흙막이벽의 차수효과를 높이기 위하여 고압분사주입공법을 실시하여 차수벽을 설치하는 보조공법인 널지 이용되고 있다. 고압분사주입공법에 의해 가설흙막이벽 배면지반에 시공된 지반개량체의 지반보강효과 및 차수효과를 검토하기 위하여 각종 실내시험 및 현장시험을 실시하였다. 시험결과 지반개량체는 지반조건과 시공방법에 따라 약간의 차이는 있으나 충분한 흙막이벽 배면지반의 보강 및 벽체의 강성보강 효과를 얻을 수 있는 것으로 나타났다. 한편 지반개량체의 투수계수는 원지반의 투수 계수보다 10-2~10-3cm/s정도 작아서 흙막이벽의 차수효과를 기대할 수 있는 것으로 나타났다.

  • PDF