• Title/Summary/Keyword: Bottom plate

Search Result 539, Processing Time 0.026 seconds

Longitudinal anti-cracking analysis for post-tensioned voided slab bridges

  • Zhou, Zhen;Meng, Shao-Ping;Liu, Zhao
    • Structural Engineering and Mechanics
    • /
    • v.43 no.4
    • /
    • pp.459-473
    • /
    • 2012
  • Post-tensioned concrete voided slab girders are widely used in highway bridge constructions. To obtain greater section hollow rate and reduce the self-weight, the plate thickness of slab girders are designed to be small with the adoption of flat anchorage system. Since large prestress is applied to the anchor end section, it was found that longitudinal shear cracks are easy to occur along the voided slab girder. The reason is the existence of great shearing effect at the junction area between web and bottom (top) plate in the anchor end section. This paper focuses on the longitudinal anti-cracking problem at the anchor end of post-tensioned concrete voided slab girders. Two possible models for longitudinal anticracking analysis are proposed. Differential element analysis method is adopted to derive the solving formula of the critical cracking state, and then the practical analysis method for longitudinal anti-cracking is established. The influence of some factors on the longitudinal anti-cracking ability is studied. Results show that the section dimensions (thickness of bottom, web and top plate) and prestress eccentricity on web plate are the main factors that influence the anti-cracking ability. Moreover, the proposed method is applied into three engineering examples to make longitudinal anti-cracking verification for the girders. According to the verification results, the design improvements for these girders are determined.

Residual stress distribution analysis in a J-groove dissimilar metal welded component of a reactor vessel bottom head using simulation and experiment

  • Dong-Hyun Ahn;Jong Yeon Lee;Min-Jae Choi;Jong Min Kim;Sung-Woo Kim;Wanchuck Woo
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.506-519
    • /
    • 2024
  • To simulate the verification process using materials from a decommissioned reactor, a mock-up of the bottom-mounted instrument nozzle in the Kori 1 reactor, where the nozzle was attached to a plate by J-groove dissimilar metal welding, was fabricated. The mock-up distortion was quantified by measuring the plate surface displacement after welding. The residual stresses formed on the support plate surface and the inner surface of the nozzle were then analyzed using the hole-drilling method, contour method, and neutron diffraction. Welding simulations were performed using a 3D finite element method to validate the measured results. The measured and computed stress distributions on the support plate exhibited reasonable agreement. Conversely, the stresses on the inside of the nozzle were found to have an indisputable difference in the contour method and neutron diffraction measurements, which demonstrated strong tensile and compressive hoop stresses, respectively. The possible origins of such differences were investigated and we have provided some suggestions for a precise evaluation in the simulation. This study is expected to be useful in future research on decommissioned reactors.

Optimum Operating Conditions of a Vacuum Nozzle Seeder (진공노즐식 파종기의 최적 작동조건)

  • 민영봉;김성태;정태상
    • Journal of Biosystems Engineering
    • /
    • v.25 no.6
    • /
    • pp.463-470
    • /
    • 2000
  • For maximum seeding efficiency of a nozzle type seeder, the performance of the nozzle should be considered sufficiently. This study was carried out to investigate the optimum operating conditions of a seeder attached the vacuum nozzle which was modified syringe needle acting on the plug seedling tray and the seed plate. Such operating factors as the hole diameter of the nozzle (d), the distance from the nozzle tip to the bottom plate of seed hopper(D) the absorbing air pressure of the nozzle tip(P) the bounding height of seed from the vibrated bottom plate of seed hopper and the seeding speed were selected based on the weight of a grain of seed(W). The treated materials were pepper seed as the flat type, cucumber seed as the oval type and radish seed as the spherical type. The optimum operating conditions of the experimental seeder were revealed as follows: 1. The height of the seed bounding from the bottom plate of seed hopper and the distance from nozzle tip to bounded seed were 5 mm and 0.5 mm at all seeds. The hole diameter of the nozzle and the absorbing pressure for pepper seed, cucumber seed and radish seed was 0.45 mm, 0.65 mm. 0.65mm and 39.2 kPa, 88.3 kPa, 58.8 kPa, respectively. 2. The absorbing pressure P was represented as P=η.4W/$\pi$d$^2$ where η was 100. The seeding speed using a 128 cell tray was 2.4 cm/s which was same transfer as 2.5 trays per minute. 3. The maximum seeding rate in case of the pepper seed was 97% the cucumber seed was 95% and the radish seed was 100% under the optimum operating conditions of the seeder.

  • PDF

The Electrical Properties and Unconfined Compression Strength of Bottom Ash (Bottom Ash의 전기적 특성과 일축압축강도)

  • Kim, Tae-Wan;Son, Young-Hwan;Park, Jae-Sung;Noh, Soo-Kack;Bong, Tae-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.1
    • /
    • pp.21-30
    • /
    • 2014
  • The objective of this study is to find the electrical properties of Bottom ash from thermoelectric power plants in Korea. By using Parallel Plate Method, the electrical resistivity and dielectric constant were measured at the frequency from 20 Hz to 10 MHz. Also, unconfined strength test, XRF and sieve analysis were performed for finding the relationship between strength, physiochemical properties and electrical properties. In the result, the change of electrical resistivity and dielectric constant of bottom ash against frequency was similar to that of general soil. The proportion of fine grain in bottom ash had the positive correlation with dielectric constant and negative correlation with electrical resistivity. Chloride and sulfur trioxide were proportional to dielectric constant and the more bottom ash had chloride content, the lower electrical resistivity appeared in bottom ash. Unconfined strength of bottom ashes had a range from 200 kPa to 780 kPa and strength was inverse proportional to electrical resistivity.

Analysis Models of Concrete Slabs-on-Grade Considering Horizontal Resistance at Slab Bottom and Behavior under Thermal Loads (슬래브 하부 수평저항을 고려한 지반위의 콘크리트 슬래브 해석 모델 및 온도하중에 의한 거동 분석)

  • Kim Seong-Min;An Zu-Og
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.271-282
    • /
    • 2006
  • The behavior of the concrete slabs on grade considering the horizontal resistance at the slab bottom, which exists due to the shear resistance of the foundation and the friction between the slab and the foundation, has been investigated when the slabs-on-grade are subjected to the thermal load. Analytical formulations have been developed to include the effect of the horizontal resistance at the slab bottom employing the thin plate on an elastic foundation that is widely used for the analysis of concrete slabs-on-grade and rigid pavement systems. Finite element formulations have then been developed using the plate bending elements and the flat shell elements. The solutions from the analytical and numerical models have been compared and showed very good agreement. The sensitivity of the horizontal resistance to the stresses of the concrete slab has been investigated with various values of the slab thickness, elastic modulus, and vortical stiffness of the foundation when subjected to the temperature gradient between the top and bottom of the slab and the uniform temperature drop throughout the slab depth. The analysis results show that the horizontal resistance at the plate bottom can significantly affect the stresses of the slab when the thermal loads are applied.

Shear strength of connections between open and closed steel-concrete composite sandwich structures

  • Kim, Woo-Bum;Choi, Byong Jeong
    • Steel and Composite Structures
    • /
    • v.11 no.2
    • /
    • pp.169-181
    • /
    • 2011
  • The behavior of connections between open sandwich slabs and double steel skin composite walls in steel plate-concrete(SC) structure is investigated by a series of experimental programs to identify the roles of components in the transfer of forces. Such connections are supposed to transfer shear by the action of friction on the interface between the steel surface and the concrete surface, as well as the shear resistance of the bottom steel plate attached to the wall. Experimental observation showed that shear transfer in slabs subjected to shear in short spans is explained by direct force transfer via diagonal struts and indirect force transfer via truss actions. Shear resistance at the interface is enhanced by the shear capacity of the shear plate as well as friction caused by the compressive force along the wall plate. Shear friction resistance along the wall plate was deduced from experimental observation. Finally, the appropriate design strength of the connection is proposed for a practical design purpose.

Numerical Study on the Design Safety of Corner Protection Structure in Full Containment LNG Storage Tank (완전 밀폐식 LNG 저장탱크에서 코너 프로텍션 구조물의 설계 안전성에 관한 수치적 연구)

  • Kim Chung Kyun;Cho Seung Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.54-60
    • /
    • 2004
  • In this paper, the maximum von Mises stress and maximum displacement of the corner protection and secondary bottom structures have been analyzed using a finite element analysis technique. The design criterion of the comer protection is 1,500Pa for a normal nitrogen gas purging process at the beginning stage of start-up procedure. This pressure is very safe for the structure safety of the comer protection and secondary bottom plates. The corner protection and secondary bottom plates fabricated by $9\%$ nickel steel sheet may plastically be distorted and fractured for the increased gas pressure of 8,475Pa, which produces the maximum von Mises stress of 833MPa and maximum displacement of 1.9m at the center of secondary bottom plate.

  • PDF

Numerical Study on the Hydroelastic Response of the Very Large floating Structure Considering Sea-Bottom Topography (해저 지형을 고려한 초대형 부유체의 유탄성 거동 해석)

  • Kyoung, Jo-Hyun;Kim, Byoung-Wan;Cho, Seok-Hyu;Hong, Sa-Young
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.4 s.142
    • /
    • pp.357-367
    • /
    • 2005
  • A numerical method is developed for the hydroelastic response of the Very Large Floating Structure considering the sea-bottom topography. The sea-bottom effects on the hydroelastic response of the floating structure is studied. The sea-bottom topography should be considered when the floating structure is constructed near the shore. To investigate the sea-bottom effects, four different sea-bottom topographies are considered in this study. finite-element method based on the variational formulation is used in the fluid domain, The pontoon-type floating structure is modeled as the Kirchhoff plate. The mode superposition method is adopted for the hydroelastic behavior of the floating structure.

Effect of plate slope and water jetting on the penetration depth of a jack-up spud-can for surficial sands

  • Han, Dong-Seop;Kim, Seung-Jun;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.263-278
    • /
    • 2014
  • The spudcan requires the suitable design considering the soil, platform, and environmental conditions. Its shape needs to be designed to secure sufficient reaction of soil so that it can prevent overturning accidents. Its shape also has to minimize the installation and extraction time. Even in the same soil condition, the reaction of soil may be different depending on the shape of spud can, mainly the slope of top and bottom plates. Therefore, in this study, the relation between the slope of plates and the reaction of soil with and without water jetting is analyzed to better understand their interactions and correlations. For the investigation, a wind turbine installation jack-up rig (WTIJ) is selected as the target platform and the Gulf of Mexico is considered as the target site. A multi layered (sand overlying two clays) soil profile is applied as the assumed soil condition and the soil-structure interaction (SSI) analysis is performed by using ANSYS to analyze the effect of the slope change of the bottom plate and water jetting on the reaction of soil. This kind of investigation and simulation is needed to develop optimal and smart spudcan with water-jetting control in the future.

Recycling of Wastepaper(IX)-Effects of KOCC Fines and Other Contamination on Condebelt Press Drying System- (고지재생연구(제 9보)-국산 골판지 고지 내의 미세분 및 이물질들이 Condebelt Press Drying System에 미치는 영향-)

  • 지경락;류정용;신종호;송봉근
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2000
  • In Condebelt press drying system, the temperature difference between top and bottom plate of Condebelt transfers water to bottom side, Fine fibers, stickies , ink , and various inorganic materials are also migrated to the fine wire located at the bottom plate by highly pressurized moisture flow. As a result, the fine wire contaminated by plugging of these fine and sticky materials can cause many problems such as blistering or partial crushing of paper. The contaimination of fine wire leads to a deterioroated strength together with uneven physical properties of paper. In this paper, froth-flotatiion method, which is commonly used in the field of ONP recycling process, were adopted to separate the contaminants in KOCC as a new fiber fractionation method. Standard deviation of paper strength and brighteness decreased of Condebelt fine wire were measured to investigate the effect of contaminants removal . The standard deviations of paper strength obtained from the flotated accept were not dependent on the number of condebelt press drying . However, in the case of untreated KOCC, the standard deviations were increased as press drying repeated. This indicates that the contaminant gives uneven physical properties to the paper by wire plugging . Optical and SEM images clearly illustrate the effect of contaminants on the wire condition.

  • PDF