• Title/Summary/Keyword: Bottom gap

Search Result 176, Processing Time 0.025 seconds

A Study on the Thermal Properties of Architectural Greenery System Typology Based on the Contemporary Architectural Trend (현대건축경향에 입각한 건축물녹화시스템 유형의 열적물성치에 관한 연구)

  • Kim, Tae-Han;Lee, Ju-Hee;Kim, Chul-Min
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.65-74
    • /
    • 2013
  • Recently, greenery system is frequently applied on buildings and artificial grounds to improve urban ecological functionality. Specifically, architectural greenery is also known as an architectural language that can meet the sustainable design concept of architects. Although the architectural greenery system can be optimized through an interdisciplinary approach between architecture, horticulture and landscape- architecture, there is a problem of communication on the ideal gap between them. Therefore, this study is expected to establish the comtemporary architecture as hi-tech and the organic architecture in internationalism. Moreover, it can analyze the case study on architectural greenery system designed by a Pritzker Prize winner who represents the comtemporary architectural trend. In this analysis, we calculate and compare the U-value of the free-form surface system based on the international standards: ISO and CIBSE etc. Moreover, we calculate a change of artificial soil transmittance respect on compounding ratio of the bottom ash and pearlite. In the case of California Academy of Science by Renzo Piano, total transmittance of the greenery system results in 48% of domestic thermal insulation standard in dry condition. This result will be used as a basic study to promote developing the advanced system based on the concept of consilience.

TFBAR Lattice and Balanced Type Filter Topologies (격자형 및 평형 구조를 가지는 박막공진 여파기에 관한 연구)

  • 김건욱;구명권;육종관;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1048-1053
    • /
    • 2002
  • In this paper, thin film bulk acoustic resonator(TFBAR) lattice and balanced type filter topologies are designed and fabricated. Aluminium nitride and platinum are used for piezoelectric material and top and bottom electrodes, respectively. Air-gap is placed to avoid silicon substrate loading effect and the performance of these lattice and balanced filters is compared with ladder filters. These filters have selectivity over 15 dB for lattice type and 30 dB for balanced type and reveal wider bandwidth of the ladder filters. For balanced type filters, minor tuning procedure is not needed and they are readily available for RF filter in wireless applications.

Structural and Electrical Properties of PZT(10/90)/PZT(90/10) Heterolayered Thin Films (PZT(10/90)/PZT(90/10) 이종층 박막의 구조적, 전기적 특성)

  • Lee, Seong-Gap;Kim, Gyeong-Tae;Bae, Seon-Gi;Lee, Yeong-Hui
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.98-102
    • /
    • 2000
  • Ferroelectric PZT heterolayered thin films were fabricated by spin coating method on the Pt/Ti/SiO2/Si substrate using PZT(10/90) and PZT(90/10) m7etal alkoxide solutions. All PZT heterolayered films showed a homogeneous grain structures without presence of rosette structure. It can be assumed that the lower PZT layers played a role of nucleation site for the formation of the upper PZT layer. Pb-deficient PZT phase was formed at PZT/Pt interface due to the diffusion of Pb element into a Pt bottom electrode. The relative dielectric constant and the dielectric loss of the PZT-6 film were 567 and 3.6%, respectively. Increasing the number of coatings, remanent polarization and coercive field were decreased and the values of the PZT-6 heterolayered film were $7.18\muC/cm^2$ and 68.5kV/cm, respectively. Leakage current densities were increased with increasing the number of coatings, and the value of the PZT-4 film was about $7\times10-8A/cm^2$ at 0.05MV/cm.

  • PDF

Towards guidelines for design of loose-laid roof pavers for wind uplift

  • Mooneghi, Maryam Asghari;Irwin, Peter;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • v.22 no.2
    • /
    • pp.133-160
    • /
    • 2016
  • Hurricanes are among the most costly natural hazards to impact buildings in coastal regions. Building roofs are designed using the wind load provisions of building codes and standards and, in the case of large buildings, wind tunnel tests. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. The objective of this paper is to develop simple guidance in code format for design of loose-laid roof pavers. Large-scale experiments were performed to investigate the wind loading on concrete roof pavers on the flat roof of a low-rise building in Wall of Wind, a large-scale hurricane testing facility at Florida International University. They included wind blow-off tests and pressure measurements on the top and bottom surfaces of pavers. Based on the experimental results simplified guidelines are developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as American Society of Civil Engineering (ASCE) 7-10 standard's pressure coefficients for components and cladding. The effects of the pavers' edge-gap to spacer height ratio and parapet height to building height ratio are included in the guidelines as adjustment factors.

The Dielectric Properties of $BaTiO_3/SrTiO_3$ Heterolayered Thick Films ($BaTiO_3/SrTiO_3$ 이종층 후막의 유전특성)

  • Nam, Sung-Pill;Lee, Sang-Chul;Lee, Sung-Gap;Lee, Young-Hie
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.58-60
    • /
    • 2004
  • The $BaTiO_3/SrTiO_3$ heterolayered thick films were fabricated on alumina substrate by screening printing method. The obtained films were sintered at $1400^{\circ}C$ with bottom electrode of Pt for 2 hours. The structural and electrical properties of $BaTiO_3/SrTiO_3$ heterolayered thick films were compared with pure $BaTiO_3$ and $SrTiO_3$ films. The (Ba,Sr)$TiO_3$ phase was appeared at the $BaTiO_3/SrTiO_3$ heterolayered thick films. The thickness of $BaTiO_3/SrTiO_3$ heterolayered thick film, obtained by one printing, was about $50{\mu}m$. The dielectric constant and dielectric loss of the $BaTiO_3/SrTiO_3$ heterolayered thick films were about 1964, 5.5% at 1KHz, respectively.

  • PDF

A Study on the Mechanism with the Electrode Ratio of Driving and Generation Part of a Disk-Type Piezoelectric Transformer (디스크형 압전변압기의 전극 면적비에 따른 구동 메카니즘에 관한 연구)

  • Lee, Jong-Pil;Chae, Hong-In;Jin, Woong-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.17-22
    • /
    • 2005
  • In this study, a disk-type piezoelectric transformer was fabricated. Its diameter was 50[mm] and thickness was 4.5[mm]. The driving and generating electrode with their gap of 1[mm] were fabricated on the top surface. But the common electrode was fabricated on the whole bottom surface. The electrode surface ratio of driving and generating part on the top surface was the range of 1.4:1 to 3:1. We investigated the electrical characteristics with the variation of its thickness and the electrode surface ratio of driving and generating part in the range of load resistance of 100${[\Omega]}\~70{[k\Omega]}$.. Form the experimental results, their influence on the set-up voltage ratio were investigated quantitively and qualitatively.

Anallysis of the flow and noise characteristics of small turbo fan in a ultra slim note PC (초박형 노트북 냉각 터보팬의 유동 및 소음 분석)

  • Jeon, W.H.;Lim, T.G.;Minorkkawa, Gaku;Miyahara, Masaharu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.775-780
    • /
    • 2013
  • In recent years, a notebook like an ultrabook gets thinner. Its thickness causes problems in cooling fan performance, system installation condition, and so on. In this study, we installed a small turbofan in notebook system with very narrow gap in order to generate similar condition to a real product. Experiments were performed to measure the fan's performance and the flow and noise characteristics, its results were compared with computational ones. Prediction of P-Q curve using CFD showed under about 5% error in high flow rate and its trend was agreed with experimental one over the flow field. Experimental data to measure the noise at a distance of 100 mm from a rotation axis direction of an impeller corresponded well with computational ones of broadband and BPF noise. The noise experiments to measure at a distance of 100 mm from a rotation axis direction of an impeller corresponded well with computational ones of broadband and BPF noise. Especially, tip part of impeller blade and part of exit and bottom near in an analysis by a commercial program(FlowNoise).

  • PDF

A Study on the Collecting Efficiency of Oil-mist Filter according to the Sub-filter Shape (서브필터 형상에 따른 Oil-mist Filter의 포집효율 향상에 관한 연구)

  • Kim, Yong Sun;Yun, Seong Min;Shin, Hee Jae;Ko, Sang Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Cooking oil in kitchen-fog is the most harmful factor to the health of a cook. The proposed filter is a tool that protects the cooked state, to prevent users from inhaling oil mist in the kitchen. Due to efficiency issues, existing filters are of the mesh type or baffle type. In this paper, CFD analysis is carried out to select a filter with low pressure loss and low efficiency, and to attach the sub-filter to improve efficiency. The results of the analysis on the collection efficiency and pressure loss of three sub-filters, i.e., circle type, droplet type, and cone type, showed that the collection efficiency was 64.09% and the pressure loss was 1.26 mmAq when the circle type sub-filter was applied. The position of the sub-filter showed the best efficiency and pressure loss when it was located at the bottom of the center of the gap of the main filter.

Axially-compressed behavior of CFRP strengthening steel short columns having defects

  • Omid Yousefi;Amin Shabani Ammari
    • Structural Engineering and Mechanics
    • /
    • v.91 no.1
    • /
    • pp.49-61
    • /
    • 2024
  • In recent decades, the majority of studies have concentrated on the utilization of Steel Square Hollow Section (SHS) columns, with minimal attention given to reinforcing columns exhibiting inherent defects. This study addresses this gap by introducing initial vertical and horizontal defects at three distinct locations (top, middle, and bottom) and employing Carbon-FRP for reinforcement. The research investigates the dimensional and positional impacts of these defects on the axial behavior of SHS columns. A total of 29 samples, comprising 17 with defects, 11 strengthened, and 1 defect-free control, underwent examination. The study employed ABAQUS modeling and conducted experimental testing. Results revealed that defects located at different positions significantly diminished the load-bearing capacity and initial performance of the steel columns. Axial loading induced local buckling and lateral rupture, particularly at the defect side, in short columns. Notably, horizontal (across the column's width) and vertical (along the column's height) defects in the middle led to the most substantial reduction in strength and load-bearing capacity. The axial compressive failure increased with the length-to-width ratio of the defect. Moreover, the application of four carbon fiber layers to strengthen the steel columns resulted in increased Energy Dissipation and a delayed onset of local buckling in the face of axial ruptures.

An Experimental Study for Flexure/Shear Failure Behavior of Composite Beam with GFRP Plank Used As a Permanent Formwork and Cast-in-place High Strength Concrete (영구거푸집으로 사용한 유리섬유 FRP 판과 현장타설 고강도콘크리트로 이루어진 합성보의 휨/전단파괴거동에 관한 실험적 연구)

  • Yoo, Seung-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4245-4252
    • /
    • 2015
  • In this study, an experiment which utilized glass fiber reinforced polymer(GFRP) plank as the permanent formwork of cast-in-place high strength concrete structures was performed. The GFRP plank currently being produced has smooth surface so that it causes problems in behavior with concrete. Therefore, this research analyzed the flexure/shear failure behavior of composite beams, which used GFRP plank as its permanent formwork and has short shear span ratio, by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 47% higher ultimate load value was obtained when the sand was coated than not coated case and bending/shear failure mode was observed. For effectiveness of perforation and interval of gap, approximately 24% higher maximum load value was seen when interval of the perforation gap was short and the fine aggregate was not coated, and approximately 25% lower value was observed when the perforation gap was not dense on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 17% higher in case of 40mm than 20mm width.