• Title/Summary/Keyword: Bone union

Search Result 306, Processing Time 0.02 seconds

TREATMENT OF INFECTED MANDIBULAR FRACTURES (감염된 하악골 골절의 치험)

  • Kim, Hyoun-Chull
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.2
    • /
    • pp.41-47
    • /
    • 1990
  • Treatment of infected mandibular fractures is confronted with various difficult problem, e.g. eradication of infection and osseous union even in the presence of devastating infection. To solve this problem various methods were proved including exteranal fixation, IMF and plating with some success. Author treated 3 cases of infected mandibular fractures with champy's miniplate. 1. Satisfactory union was obtained in 3 cases. 2. In One case, pus drainage continued even after internal fixation with miniplate, but it was easily controlled using proper antibiotic therapy & drainage. 3. In Case 3, autogenous bone graft was implanted into the infected fracture site to fill defect.

  • PDF

Delayed union of a pediatric lunate fracture in the United Kingdom: a case report and a review of current concepts of non-scaphoid pediatric carpal fractures

  • Timothy P. Davis;Elizabeth Headon;Rebecca Morgan;Ashley I. Simpson
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.315-321
    • /
    • 2023
  • Pediatric carpal fractures are rare and often difficult to detect. This paper reviews the current literature on pediatric non-scaphoid carpal fractures, with a case report of a lunate fracture associated with a distal radius and ulnar styloid fracture, managed nonoperatively in a 12-year-old boy. There is lack of consensus regarding the management of these fractures due to the low number of reported cases. A frequent lack of long-term follow-up limits our understanding of the outcomes, but good outcomes have been reported for both nonoperative and operative management. This case report brings attention to the current time period for the definition of delayed union in pediatric carpal fractures, and emphasizes the need for prolonged follow-up for the detection of delayed complications leading to functional impairment.

Limb Salvage Operation with Recycled Autogenous Bone Graft (자가골 재이식술을 이용한 사지 구제술)

  • Rhee, Seung-Koo;Kang, Yong-Koo;Suh, Yoo-Joon;Yoo, Jong-Min;Jung, In-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.96-106
    • /
    • 2004
  • Purpose: To determine the usefulness of limb salvage operation with recycled autogenous bone graft in musculoskeletal malignant tumors. Materials and Methods: Twenty nine cases, who underwent limb salvage operation with recycled autogenous bone graft for the treatment of musculoskeletal malignant tumor between February 1990 and January 2003, were included. There were 18 males and 11 females and the mean age was 33 years (range, 10 to 65 years). The mean follow-up period was 51.8 months (range, 18 to 117 months). The Enneking stage was IIA in 10 cases and IIB in 19 cases. The recycling method of autogenous bone was deep freezing in 6 cases, autoclaving in 11 cases, pasteurization in 7 cases and the composite of autoclaving and vascularized fibular graft in 5 cases. The union of junctional site was evaluated radiologically and the functional results was analyzed by the grading systems of the International Symposium On Limb Salvages (ISOLS). Results: The mean union time was 7.2 months (range, 3 to 15 months). The union took 5.8 months (range, 4 to 8 months) in deep freezing, 9.7 months (range, 6 to 15 months) in autoclaving, 5.9 months (range, 4 to 8 months) in pasteurization, and 5 months (range, 4 to 8 months) in the composite of autoclaving and vascularized fibular graft. The mean functional evaluation percentage was 76.8% (range, 40 to 90%). It was 65.8% (range, 40 to 85%) in deep freezing, 76.6% (range, 40 to 90%) in autoclaving, 81.6% (range, 70 to 90%) in pasteurization, and 83.4% (range, 75 to 90%) in the composite of autoclaving and vascularized fibular graft. There were 6 cases of complications including 1 case of local recurrence, lung metastasis, infection, fracture, respectively and 2 cases of nonunion. Conclusion: The limb salvage operation with recycled autogenous bone graft is a useful treatment method for the musculoskeletal malignant tumors. Particularly, autoclaving is the most reliable sterilization method. The vascularized fibular graft can compensate decreased osteoinductivity and mechanical strength of recycled bone. So, the composite of autoclaving and vascularized bone graft seems to be a favorable treatment method for high grade malignant musculoskeletal tumors.

  • PDF

Ankle Arthrodesis with Vascularized Fibular Graft in Failed Ankle Fusion (혈관 부착 비골 이식술을 이용한 실패한 족관절 고정술의 치료)

  • Chung, Duke Whan;Chung, Chai Ik;Lim, Young Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.2
    • /
    • pp.134-138
    • /
    • 2000
  • Arthrodesis of the ankle joint is inevitable in the cases of severe arthrosis or defective bony structures around ankle joint. There have been many kinds of arthrodesis methods were introduced. In cases with failed athrodesis with previous arthrodesis surgery and neuropathic joints have difficulty to achieve fusion of joint with conventional methods. Authors underwent four cases of ankle fusion with vascularized fibular graft from 1997 in the cases of three failed fusions and one diabetic neuropatic joint. Two of four performed free vascularized fibular transplantation from contralateral side leg with microvascular anastomosis, two of four performed with pedicled fibular transposition to the ankle joint in same side leg. Three of four cases achieved arthrodesis average 9.2 months after surgery, one case was failed due to vascular thrombosis of the anastomosed site in diabetic neuropathic condition. The result of this technique revealed 75%(three of four) success rate and longer bone union time required. However, in these cases had no recommendable options with conventional bone graft and additional ankle joint fusions procedure because of poor bone quality and defect of distal tibia and talus portions. Free vascualrized fibular transfer to the failed athrodesis of ankle joint is one of the effective alternative methods in failed ankle fusion cases, especially the quality of the bone around previous fusion site is poor.

  • PDF

Treatment of pathologic fracture following postoperative radiation therapy: clinical study

  • Kim, Chul-Man;Park, Min-Hyeog;Yun, Seong-Won;Kim, Jin-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.31.1-31.5
    • /
    • 2015
  • Background: Pathologic fractures are caused by diseases that lead to weakness of the bone structure. This process sometimes occurs owing to bony change after radiation therapy. Treatment of pathologic fractures may be difficult because of previous radiation therapy. Methods: In this study, we analyzed clinical and radiographic data and progress of five patients with mandibular pathological fractures who had received postoperative radiation therapy following cancer surgery. Result: Patients received an average radiation dose of 59.2 (SD, 7.2) Gy. Four of five patients exhibited bone union regardless of whether open reduction and internal fixation (OR/IF) was performed. Patients have the potential to heal after postoperative radiation therapy. Treatment of a pathologic fracture following postoperative radiation therapy, such as traditional treatment for other types of fractures, may be performed using OR/IF or CR. OR/IF may be selected in cases of significant bone deviation, small remaining bone volume, or occlusive change. Conclusion: Patients have the potential to heal after postoperative radiation therapy.

Development of a Functional Fixator System for Bone Deformity Near Joints

  • Chun, Keyoung-Jin;Lee, Ho-Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.234-241
    • /
    • 2006
  • A functional external fixator system for bone deformity near the joints using worm gear was developed for curing the angle difference in fracture bones while the lengthening bar was developed for curing the differences in length, also in fracture bones. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for bone deformity near joints. The FE model using compressive and bending FE analysis was applied due to the angle differentiations. The results indicate that compressive stiffness value in the experiment was 175.43N/mm, bending stiffness value in the experiment was 259.74 N/mm, compressive stiffness value in the FEA was 188.67 N/mm, and bending stiffness value in the FEA was 285.71 N/mm. Errors between experiments and FEA were less than $10\%$ in both the 'compressive stiffness and the bending stiffness. The maximum stress (157 MPa) applied to the angle of the clamp was lower than the yield stress (176.4 MPa) of SUS316L. The degree of stiffness in both axial compression and bending of the new fixator are about 2 times greater than other products, with the exception of EBI (2003).

Multicentric Chondrosarcoma - case report - (다발성 연골육종 1례 보고)

  • Jeon, Dae-Geun;Lee, Jong-Seok;Kim, Sug-Jun;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.2
    • /
    • pp.112-118
    • /
    • 1997
  • Multicentric chondrosarcoma other than the mesenchymal subtype is rare separate entity. We experienced a case with nonmonomelic synchronous multicentric chondrosarcoma without any preexisting lesions of Oilier's disease or Maffucci's syndrome. To our knowledge, there was no report of synchronous nonmonomelic multicentric chondrosarcoma. A thirty-three year old man had right distal thigh pain of one and half year. Bone scan showed hot lesions on medial condyle of right femur and shaft of left femur. Plain X-ray showed osteolytic lesion on right femur and slight cortical thickening and calcific lesion was observed on left femoral shaft. Curettage and bone cement filling was done on both lesions. The pathology reports were grade I chondrosarcoma on both side of femur. At one month from operation, pathologic fracture of left femur occurred on bone cement-host bone junction. Conservative treatment and radiotherapy of 60Gy was done. At 8 months from operation, nonunion was evident. Segmental resection of left femur with contralateral fibula graft and second look operation on right condyle lesion were done. At 6 months from revision, fracture occurred at host-graft bone junction. We removed previous hardware and applied long DCP and massive autogenous bone graft. Afterwards, the patient looks good and union was progressing. But at 4 years from last operation, hypertrophic nonunion occurred. Another revision was done with condylar plate and bone graft and now he is well without any sign of local recurrence or metastasis.

  • PDF

LONG-TERM RESULTS OF VERTICAL HEIGHT AUGMENTATION GENIOPLASTY USING AUTOGENOUS ILIAC BONE GRAFT (장골 이식을 이용한 수직 증강 이부 성형술 후의 장기간 결과)

  • Kim, Gi-Jung;Park, Hyung-Sik;Yoon, Kyu-Sik;Lee, Eui-Wung;Jung, Young-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.6
    • /
    • pp.509-514
    • /
    • 2005
  • Purpose: In order to clarify the clinical utility of the vertical height augmentation (VHA) genioplasty using autogenous iliac bone graft (IBG), this study examined the postsurgical changes in hard and soft tissues of the chin and the stability of the grafted bone. Patients and Methods: Twenty-three patients who had undergone VHA genioplasty using autogenous IBG were evaluated radiographically and clinically. A comparison study of the changes in hard to soft tissues after surgery in all 23 patients was performed with preoperative, 1-month, 3-months, 6-months, and/or 1-year postoperative lateral cephalograms by tracing. Stability, bone healing, and complication of the grafted bone was evaluated by follow-up roentgenograms and clinical observation. Results: Between the preoperative and 6-month postoperative tracings, an average vertical augmentation of the osseous segment was 4.2 mm at menton and that of the soft tissue menton was 4.0 mm. There was a high predictability of 1: 0.94 between the amounts of hard versus soft tissue changes with surgery in the vertical plane. The position of the genial bone segment was stable immediately after surgery and soft tissue was not changed significantly from 1 month to 1 year after operation. Clinical and radiological follow-up results of the iliac bone graft showed normal bony union and were generally stable. Conclusions: VHA genioplasty using IBG is a reliable method for predicting hard and soft tissue changes and for maintaining postoperative soft tissue of the chin after surgery.

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

The Operative Treatment using Porous Hydroxyapatite for Intraarticular Calcaneal Fractures of Joint Depression Type (관절함몰형 종골 골절에 대한 다공성 하이드록시 아파타이트를 이용한 수술적 치료)

  • Choi, Eui-Sung;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Park, Kyoung-Jin;Cho, Byung-Ki;Park, Ji-Kang;Yoo, Jun-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.58-65
    • /
    • 2010
  • Purpose: This study was performed to evaluate the clinical outcomes of operative treatment using porous hydroxyapatite for intraarticular calcaneal fracture of joint depression type. Materials and Methods: Twenty patients with intraarticular calcaneal fracture were followed up for more than 1 year. The period to union was calculated to evaluate the osteoconductivity of porous hydroxyapatite used as bone graft substitute. The measurement of Bohler angle, Gissane angle and the degree of articular surface depression was performed through preoperative and postoperative radiographs. The clinical evaluation was performed according to hindfoot score of the American Orthopaedic Foot and Ankle Society (AOFAS) and scale of the Creighton-Nebraska health foundation (CNHF). Results: Bohler angle and Gissane angle had improved significantly from preoperative average $10.4^{\circ}$, $117.8^{\circ}$ to average $22.6^{\circ}$, $113.5^{\circ}$ immediate postoperatively, and had maintained to average $21.2^{\circ}$ and $114.4^{\circ}$ at the last follow-up. The degree of articular surface depression had improved significantly from preoperative average 4.8 mm to 1.5 mm at the last follow-up. All cases achieved bone union, and the interval to union was average 12.8 weeks. AOFAS score was average 85.2 points at last follow-up. There were 7 excellent, 10 good, and 3 fair results according to the CNHF scale. Therefore, 17 cases (85%) achieved satisfactory results. Conclusion: Plate fixation using porous hydroxyapatite seems to be one of effective treatment methods for intraarticular calcaneal fracture of joint depression type, because of supporting the reduction of subtalar articulation by augmenting bony defect and facilitating bone formation. Further evaluation about long-term radiological changes and histological analysis on hydroxyapatite implantation site should be required.