• Title/Summary/Keyword: Bone to Implant Contact

Search Result 257, Processing Time 0.024 seconds

THE EVALUATION OF THE REMOVAL TORQUE AND THE HISTOMORPHOMETRY OF THE CA-P COATING SURFACE IN RABBIT TIBIA (가토 경골에 식립된 Ca-P 박막코팅 임프란트의 뒤틀림 제거력 및 조직형태학적 평가)

  • Kwak Myeong-Bae;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.556-571
    • /
    • 2004
  • Statement of problem: Surface texture of the implant is one of the important factors of the implant success, especially in the immediate implant loading. Many methods of the surface treatment of implant have developed and introduced. Purpose : This study was to evaluate the effects of the Ca-P coating implant crystallized the hydroxyapatite on the surface by the removal torque test and the histomorphometric analysis in vivo. Material and methods: 135 screw type implants, 4.0mm in length and 3.75mm in diameter were used in this study. Implants were divided into 3 groups and treated in the different mothods. Group I was not treated, Group II was treated in the SLA method, and Group III was treated in the Ca-P coating with the anodizing method and the hydroxyapatite was crystallized on the surface with the hydrothermal treatment. Firstly, the surface roughness of each group was measured, 45 rabbits were used in this experiment. Two implants were inserted on right tibial metaphysis and one implant was inserted on left side with the alternating order. After the healing periods of 3, 5, and 12 weeks, the rabbits were sacrificed to evaluate the osseointergration by the removal torque test and the histomorphometric analysis. Results : 1. In the analysis for the surface roughness, Group II showed the highest roughness. And Group III showed higher secondly. There was a significant difference one another statistically 2. In the removal torque test, Group III and II were significantly higher than Group I. There was no statistical difference between Group III and Group II. 3. For all Groups, the removal torque values at 12th week were significantly higher than at 3rd and 5th week. 4. In histomorphometric analysis, the bone implant contact rates of Group III and II were higher than that of Group I at 3rd and 5th week. There was a significant difference at 5th week. 5. In histomorphometric analysis, the bone implant contact rate of Group III and II increased from 3rd week to 5th week, but decreased at 12th week. In Group I, the contact rate at 12th week was significantly higher than at 3rd week and 5th week.

Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs

  • Kim, Dong-Seok;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants(diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels(P=.46) and RFA values. The mean BIC % in the Mg-implants was $54.5{\pm}8.4%$. The mean BIC % in the turned implant was $45.3{\pm}12.2%$. These differences between the Mg-implant and control implant were statistically significant(P=.005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact(BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

THE INFLUENCE OF THE INITIAL STABILITY AFTER DENTAL IMPLANT INSTALLATION ON THE OSSEOINTEGRATION (임프란트 식립시 초기 안정성이 골유착에 미치는 영향)

  • Lee, Young-Hoon;Kim, Yeo-Gab;Choi, Byung-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.518-528
    • /
    • 2008
  • Purpose: The long-term experience of using osseointegrated implants for prosthetic rehabilitation of the edentulous patients shows that high success rates can be predictably achieved. Primary implant stability has been identified to be a prerequisite to achieve osseointegration. In this study, we set up the amount of removed bone so that it differed on implant installation site for each group. The influence of each initial stability on secondary stability and osseointegration was compared with time lapse using resonance frequency analysis and histomorphometric analysis. Materials and methods: A total 27 US $II^{(R)}$ (Osstem, Korea) implants were placed in the mandibular edentulous area of 3 beagle dogs. The implant site was prepared by the conventional technique with drills, and three experimental groups were divided into under-drilling group, normal-drilling group and over-drilling group. The Implant Stability Quotient (ISQ) was measured at intervals of immediately, 4, 8, 12 weeks after placement using $Osstell^{(R)}$ mentor RFA. After the animals were sacrificed, histomorphometric evaluation was executed for measuring BIC and BD. Results: 1) The under-drilled group showed most high ISQ value for whole experiment period. 2) Bone-to-implant-contact(BIC) showed the tendency to be increased gradually as the experiment period passed except the 8 weeks of the normal group. 3) The under-drilled group showed most high bone density(BD) level for whole experiment period, and it was expressed the aspect to be increased gradually according to an experiment period passage in the average of all group. 4) Resonance frequency analysis and histomorphometric analysis are presumed by generally proportional. Conclusions: As this research result, it seems that there are some correlation between resonance frequency analysis and histomorphometric analysis. As are accomplished osseointegration stably so that more superior at the region which the overpressure comes to add, it will be applicable method in clinical field.

COMPARISON BETWEEN $TIUNITE^{TM}$ AND ANOTHER OXIDIZED IMPLANT USING THE RABBIT TIBIA MODEL

  • Yeo, In-Sung;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.339-344
    • /
    • 2007
  • Statement of problem. Various anodic oxidation techniques can be applied to dental implant surfaces. But the condition for optimal anodized surfaces has not been described yet. Purpose. The purpose of this investigation was to compare an implant that was oxidized by another method with $TiUnite^{TM}$ through resonance frequency analysis and histomorphometry. Material and methods. Turned (control), $TiUnite^{TM}$ and another oxidized fixtures, which used $Ca^{2+}$ solution for anodic oxidation, were placed in the tibiae of 5 New Zealand White rabbits. The bone responses were evaluated and compared by consecutive resonance frequency analysis once a week for 6 weeks and histomorphometry after a healing period of 6 weeks. Results. At the first week, both oxidized implants showed significantly higher implant stability quotient (ISQ) values than the control. No significant differences in resonance frequency analysis were found between the two oxidized groups for 6 weeks. The means and standard deviations of bone-to-implant contact (BIC) ratios were $71.0{\pm}4.2$ for $TiUnite^{TM}$, $67.5{\pm}10.3$ for the $Ca^{2+}$-based oxidation fixture, $22.8{\pm}6.5$ for the control. Both oxidized implants were significantly superior in osseointegration to the turned one. There was, however, no statistically significant difference between the two oxidized implants. Conclusion. $TiUnite^{TM}$ and the $Ca^{2+}$-based oxidation fixture showed superior early bone response than the control with respect to resonance frequency analysis and histomorphometry. No significant differences between the oxidized groups, however, were found in this investigation using the rabbit tibia model.

EFFECTS OF THE ION BEAM ASSISTED DEPOSITION OF HYDROXYAPATITE ON OSSEOINTEGRATION OF THE ENDOSSEOUS IMPLANTS IN RABBIT TIBIAE (이온빔 보조 전자빔 수산화 인회석 증착이 골내 임플란트의 골유착에 미치는 영향)

  • Jung, Young-Chul;Han, Chong-Hyun;Lee, In-Seop;Lee, Hyeon-Jeong;Kim, Myeong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.659-674
    • /
    • 2000
  • A large increase in the use of thin film coating of hydroxyapatite(HA) in implant dentistry is driven by the desire to take advantage of the excellent biocompatibility and high strength of HA coating. The purpose of this study was to evaluate the effects of HA-coated implants by ion Beam Assisted Deposition(IBAD) method in comparison to the sand-blasted and machined surfaces. Osteoblast culture test, removal torque test and histomorphometric analysis were performed and the following results obtained; 1. Examination of the osteoblast cultures displayed no difference in the secretion of alkaline phosphatase between the various specimen, but IBAD with pure HA specimen showed low alkaline phosphatase secretion(p<0.05). 2. Removal torque tests showed HA-coated implants by IBAD method to be similar in high value to the implants with sand-blasted surface than the implants with machined surface. And the ovariectomized group showed low mechanical test value than the normal group(p<0.05). 3. Histomorphometrical comparisons were performed on undecalcified ground sections. HA-coated implants by IBAD method demonstrated the highest mean bone-to-metal contact ratio on all threads and 3-best consecutive threads, and the implants with sand-blasted surface and implants with machined surface was in the next consecutive order(p<0.05). HA-coated implants showed slightly higher bone-to- metal contact ratio than sand-blasted implants, but no statistically significant difference was obtained between the two materials. The ovariectomized group showed lower value of bone-to-metal contact ratio than the normal group, but no statistically significant difference was obtained between the two groups. 4. Evaluation of bone volume on all threads and 3-best consecutive threads showed no statistically significant difference among the different surface treatment groups, but showed lower bone volume in ovariectomized group than in the normal group(p<0.05). According tn these results, thin film coated implants with HA showed high bone contact ratio, bone volume and removal torque strength in the short term, but long term observation is needed.

  • PDF

Radioprotective role of amifostine on osteointegration of titanium implants in the tibia of rats

  • Nevra Aydemir Celep;Hulya Kara ;Elif Erbas;Elif Dogan
    • Journal of Veterinary Science
    • /
    • v.24 no.3
    • /
    • pp.35.1-35.10
    • /
    • 2023
  • Background: Titanium is the most widely used metal for bone integration, especially for cancer patients receiving ionizing radiation. This study aimed to investigate the amifostine administration that would reduce the effects of radiation on bone healing and osseointegration in rat models. Objectives: It is aimed that the application of amifostine in rats receiving radiotherapy treatment will reduce the negative effects of ionizing radiation on the bone. Methods: Thirty-five adult male Wistar rats were randomly divided into one healthy and four experimental groups. In three consecutive days, two experimental groups of rats (AMF-RT-IMP and RT-IMP) were exposed to radiation (15 Gy/3 fractions of 5 Gy each). Then the titanium implants were inserted into the left tibia. Before the radiotherapy process, a 200 mg/kg dose of amifostine (AMF) was administered to the rats in the AMF-IMP and AMF-RT-IMP groups. Twenty-eight days after the screw implant, all rats were sacrificed, and their blood samples and tibia bones were collected for analysis. Results: The results indicated an accelerated bone formation and a more rapid healing process in the screw implants in the AMF-IMP, AMF-RT-IMP, and AMF-RT groups than in the RT-IMP group. Also, bone-implant contact area measurement and inflammation decreased with amifostine treatment in the implants subjected to irradiation (p < 0.05). Conclusions: The results obtained in the present study suggested that amifostine prevents the losses of bone minerals, bone integrity, and implant position from ionizing-radiation when given before exposure.

The effect of PostGraft$^{TM}$ on implants were installed at the tibia of ovariectomized rats (난소절제술한 백서에 식립한 임플란트에 대한 PostGraft$^{TM}$의 경구 투여 효과)

  • Cho, Chun-Il;Kim, Se-Won;Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.300-307
    • /
    • 2011
  • Purpose: This study evaluated PostGraft$^{TM}$ which enhances implant stability and bone density. Materials and methods: Forty eight implants were installed at the tibia of ovariectomized rats. The group administrated with PostGraft$^{TM}$ was the experimental group, and the control group was not administrated. Implant stability was evaluated at the $2^{nd}$, $4^{th}$ and $6^{th}$ week by Periotest value, bone mineral density, bone-to-implant contact. These values were analyzed statistically with Mann-Whitney U test (P<.05). Histological analysis was evaluated at the $2^{nd}$, $4^{th}$ and $6^{th}$ week. Results: According to the Periotest$^{(R)}$ measurement, both experimental and control groups showed decrease in values as time elapsed. Greater decrease was observed in the experimental group but there was no significant difference. By examining the radiographic images, both experimental and control groups showed tendency of increase in bone density. Greater increase was seen in the experimental group but there was no significant difference. According to the bone-to-implant contact measurement, both experimental and control groups showed increase in values as time elapsed. Greater increase was seen in the experimental group. At the $2^{nd}$ and $4^{th}$ week, there was no significant difference. But at the $6^{th}$ week, there was significant difference (P<.05). By histological analysis, both experimental and control groups showed increase in bone formation as time elapsed. In addition, greater increase was seen in the experimental group. Conclusion: It could be concluded that the PostGraft$^{TM}$ medicated group showed better results in the bone density and osseointegration.

Effect of open proximal contact on adjacent tooth and implant (개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향)

  • Moon, Sohyun;Kim, Gwangyun;Cho, Seonghun;Song, Joohun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate how open contacts impact the natural teeth and dental implant prostheses. Materials and Methods: Following criteria were used to select 20 implant crowns with open proximal contacts as the experimental group (Group A): the restorations were delivered in Chosun University Dental Hospital between 2008 and 2018, the restorations are in the posterior region, opposing teeth are fixed dental prostheses, neighboring teeth are sound natural teeth, the patient had been on the maintenance program for at least 3 years. Another 20 implant crowns with closed proximal contacts were selected as the control group (Group B) using the same criteria. Between the two groups, dental caries and food impaction of the neighboring natural teeth and marginal bone-loss of the implants were compared and evaluated. Results: There was no statistically significant difference between Group A and Group B in the occurrence rates of dental caries, food impaction, and marginal bone-loss. The amount of marginal bone-loss, however, revealed statistically significant differences between the two groups, with Group A showing 0.80 ± 0.39 mm loss and Group B showing 1.1 ± 0.43 mm loss. Conclusion: Implant prostheses with open contacts could be clinically considered in select cases as such restorations revealed no harmful effects on neighboring teeth and implant restorations within the perimeters of this study.

Evaluation of Effect of Silvernanoparticle Treated Implant on Bone Formation (은나노 처리된 임플란트의 골조직 형성에 미치는 효과 평가)

  • Kim, Sin-Guen;Yoon, Youn-Jin;Lee, Young-Man;Lee, Tae-Sun;Choi, Dong-Won;Song, Yun-Jung;Park, Jun-Woo;Choi, Dong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.233-238
    • /
    • 2012
  • Purpose: To evaluate the effect of silvernanopartilce treated implants on the bone formation and osseointegration. Methods: Silvernanoparticle was produced using an anodic oxidation method. The size of silvernanoparticle ranged from 3.5 nm to 5.9 nm. To check the effect of the capability of osseointegration of silvernanoparticle coated Implant, 32 implants (16 piece of Implant treated with nanoparticle, and 16 piece of Implant was not treated for control) were placed at both the tibia of 8 New Zealand white rabbits. After 4 weeks, 4 rabbits were sacrificed and the removal torque was measured for comparison of the osseointagration ability. Further, 4 rabbits were sacrificed and sliced samples were made. H&E stain was done for microscopic finding. Results: The removal torque of the experimental group was $102.37{\pm}30.54$ N/cm, and the control group was $73.30{\pm}19.97$ N/cm. It was statistically significant (P<0.001). Microscopic finding also shows extinguish results in silvernanoparticle treated implants. Bone formation rate of the experimental group was 43.94% and the control group was 7.58%. It was observed to be statistically significant (P=0.017). Bone to implant contact rate of the experimental group was 58.09%, and the control group was 19.43%. It was found with statistical significance (P<0.001). Conclusion: The silvernanopartilce treated implant shows a better capability of bone regeneration and osseointegration than the non-treated one. Technology to produce smaller particles would make silver more useful and safer.

Periodontal regeneration capacity of equine particulate bone in canine alveolar bone defects

  • Kim, Tae-Il;Chung, Chong-Pyoung;Heo, Min-Suk;Park, Yoon-Jeong;Rhee, Sang-Hoon
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.5
    • /
    • pp.220-226
    • /
    • 2010
  • Purpose: This study was performed to evaluate the periodontal wound healing effect of particulate equine bone mineral on canine alveolar bone defects. Methods: Twelve adult male beagle dogs were used as study subjects. The mandibular second and fourth premolars were extracted prior to the experimental surgery, and the extraction sites were allowed to heal for 8 weeks. After periodontal probing, two-walled defects were created at the mesial and distal sides of the mandibular third premolars bilaterally, and the defects were filled with equine particulate bone with collagen membrane or bovine particulate bone with collagen membrane, or collagen membrane alone. The defects without any treatment served as negative controls. After probing depth measurement, animals were sacrificed at 10, 16, and 24 post-surgery weeks for micro-computed tomographic and histomorphometric analysis. Results: The equine particulate bone-inserted group showed significantly decreased values of probing depth and first bone contact compared to the negative control and collagen membrane alone groups at weeks 10, 16, and 24 (P<0.05). There were no significant differences in the new cementum length, newly-formed bone area, or newly-formed bone volume between equine particulate bone- and bovine particulate bone-inserted groups, both of which showed significantly increased values compared to the negative control and collagen membrane alone groups (P<0.05). Conclusions: Equine particulate bone showed significant differences in probing depth, first bone contact, new cementum length, newly formed bone area, and bone volume fraction values when compared to the negative control and collagen membrane alone groups. There were no significant differences between equine and bovine particulate bone substitutes in these parameters; therefore, we can conclude that equine particulate bone is equivalent to bovine bone for periodontal regeneration.