• Title/Summary/Keyword: Bone screw

Search Result 439, Processing Time 0.024 seconds

The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report - (생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 -)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Yang, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.87-90
    • /
    • 2006
  • The complication caused by a bioabsorbable interference screw is rare after anterior cruciate ligament reconstruction. We report a case of delayed inflammatory reaction at the tibial tunnel and femoral tunnel where the graft tendon had been fixed with a bioabsorbable interference screw ($Bioscrew^{(R)}$) for anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft.

  • PDF

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

The Development of Pin Screws into the Bone for External Fixator (체외 고정구용 골 삽입 금속 나사 개발)

  • Choi, Y.C.;Rhee, K.M.;Na, W.H.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.5-17
    • /
    • 2009
  • We developed bone-insertion pin screw that can be used for purposed treatment by combining with the external fixator which is the subsidiary tool for the healing of the fracture (open fracture of long bone, reconstruction of soft tissue and arthrodesis etc.) Furthermore, for the frist time, we succeeded in domestic-producing this screw, using specially-designed treating tool stuck on the lathe machine and abrasive blasting machine, and the post-dealing technique and process. In comparison with other foreign products, we could get more desirable results in various tests. This pin screw has 103% characteristics of the average of foreign products. Thus we'd like to introduce design techniques, post-dealing process and result of function tests.

  • PDF

Treatment of Ankle Lateral Malleolar Fractures Accompanying Osteoporosis using Lag Screw (골다공증과 동반된 족관절 외과 골절의 지연나사를 이용한 치료)

  • Lee, Jun-Young;Lee, Kwang-Chul
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.207-212
    • /
    • 2006
  • Purpose: To evaluate the results of ankle lateral malleolar fractures classified as Danis-Weber type B accompanying osteoporosis that were treated with lag screw. Materials and Methods: 15 cases of Danis-Weber type B ankle lateral malleolar fractures that had T score of less than -2.5 in BMD(bone mineral density) test were selected from June 2003 to December 2005. 10 cases were males and 5 cases were females with mean age of 59 years. The main injury mechanism was supination and external rotation. Mean follow-up period was 16 months. Clinical and radiologic evaluation was done according to Meyer and Kumler's criteria. Results: All cases showed satisfying result and mean radiologic bone union period was 3 months. Anatomic reduction and bone union was acquired in all cases without complications including wound infection, skin necrosis, delayed union and nonunion Conclusions: Lag screw fixation seem to be excellent treatment of Danis-Weber type B lateral malleolar fractures with osteoporosis as it can minimize soft tissue injury and enable anatomic reduction with firm fixation.

  • PDF

Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study

  • Mirac Berke Topcu, Ersoz;Emre, Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.346-359
    • /
    • 2022
  • PURPOSE. Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS. In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS. The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION. For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.

What are the Differences in Outcome among Various Fusion Methods of the Lumbar Spine?

  • Kang, Suk-Hyung;Kim, Young-Baeg;Park, Seung-Won;Hong, Hyun-Jong;Min, Byung-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.1
    • /
    • pp.39-43
    • /
    • 2005
  • Objective: For Posterior lumbar interbody fusion(PLIF) various cages or iliac bone dowels are used with or without pedicle screw fixation(PSF). To evaluate and compare the clinical and radiological results of different fusion methods, we intend to verify the effect of added PSF on PLIF, the effect of bone cages and several factors which are thought to be related with the postoperative prognosis. Methods: One hundred and ninety seven patients with lumbar spinal stenosis and instability or spondylolisthesis underwent various fusion operations from May 1993 to May 2003. The patients were divided into five groups, group A (PLIF with autologous bone dowels, N=24), group B (PLIF with bone cages, N=13), group C (PLIF with bone dowels and PSF, N=37), group D (PLIF with bone cages and PSF, N=30) and group E (PSF with intertransverse bone graft, N=93) for comparison and analyzed for the outcome and fusion rate. Results: Outcome was not significantly different among the five groups. In intervertebral height (IVH) changes between pre- and post-operation, Group B ($2.42{\pm}2.20mm$) was better than Group A ($-1.33{\pm}2.05mm$). But in the Group C, D and E, the IVH changes were not different statistically. Fusion rate of group C, D was higher than that of Group A and B. But the intervertebral height(IVH) increased significantly in group B($2.42{\pm}2.20mm$). Fusion rate of group C and D were higher than that of group A and D. Conclusion: Intervertebral cages are superior to autologous iliac bone dowels for maintaining intervertebral height in PLIF. The additional pedicle screw fixation seems to stabilize the graft and improve fusion rates.

Initial Fixation Power of Human Bone Interference Screw (인간 골 간섭 나사못의 초기 고정력)

  • Kim Jung-Man;Chung Yang-Kook;Kim Yang-Soo;Oh In-Soo;Koh Ihn-Joon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.26-30
    • /
    • 2002
  • Purpose: To estimate the initial and early phase fixation power of the human bone interference screw in reconstruction of the anterior cruciate ligament with bone-patellar tendon-bone allograft. Materials and Methods: The results of twenty eight knees of reconstruction with bone-patellar tendon-bone allograft were analysed in 6 weeks, 12 weeks, 6 months and one year following operation. Physical examination including Lachman test, flexion rotation drawer test and jerk test were performed. The KT-1000 measurement was performed at the same time. In Lachman test 0 $\~$2mm anterior displacement of the tibia was considered normal. The KT-1000 measurement of normal side was compared with operation side and the difference of the two was recorded. The MRI was checked at final follow-up. Results: All but one knee showed normal in physical examination. The failed case showed proximal migration of the graft due to insufficient number of interference screw fixation in widened tibial tunnel. Conclusions: The human cortical bone interference screw showed sufficient initial and early phase fixation power in reconstruction of the anterior cruciate ligament.

  • PDF

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

Surgical Treatment of Calcaneal Fractures of Sanders Type II and III by A Minimally Invasive Technique with 6.5 mm Cancellous Screw (6.5 mm 해면골 전산나사를 이용한 Sanders Type II 또는 III형 종골 골절의 최소 침습적 치료)

  • Oh, Yong Seung;Lee, Kyung Ho;Kim, Jung Ho;Lee, Myoung Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.3
    • /
    • pp.116-120
    • /
    • 2019
  • Purpose: This study evaluated the clinical and radiological results of 6.5 mm full threaded cancellous bone screw fixation of calcaneal fractures. Materials and Methods: Thirty seven patients diagnosed with Sanders type II or III calcaneal fractures, who underwent open reduction and internal fixation with a 6.5 mm full threaded cancellous bone screw between August 2014 and August 2017, were analyzed. Both the preoperative and postoperative Böhler angle and Gissane angle were measured radiographically. American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were also assessed. Results: The mean age of the patients was 52.7 years and the mean follow-up period was 29.5 months. In the Sanders classification, type II and III were 16 and 24 cases, respectively. The Böhler and Gissane angles improved from 21.2° and 122.6° preoperatively to 21.6° and 120.3°, respectively, in the postoperative radiographs. All cases achieved bony union, and the AOFAS ankle-hindfoot scale was 90.7 and 91.3 in Sanders type II and III, respectively, at the final follow-up. Conclusion: The treatment of calcaneal fractures using a 6.5 mm full threaded cancellous bone screw can reduce the complications with minimally invasive surgery and achieve firm fixation.

Bone Cement Augmentation of Pedicular Screwing in Severe Osteoporotic Spondylolisthetic Patients

  • Kim, Hyeun-Sung;Park, In-Ho;Ryu, Jae-Kwang;Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.6-10
    • /
    • 2007
  • Objective : The purpose of this study was to determine the effect of bone cement augmentation of pedicular screwing in severe osteoporotic spondylolisthetic patients. Methods : Twenty patients with spondylolisthesis (8 : spondylolytic spondylolisthesis 12 : degenerative spondylolisthesis) who had undergone pedicular screwing and interbody fusion for osteoporotic lumbar spine (T-score on bone mineral density<-3.0) from 2002 to 2005 were reviewed. Mean age was 62.3 years with 3 male and 17 female patients. Average follow-up period was 14 months. Average T-score on bone mineral density (BMD) was -3.62. After decompression of neural elements, about 6cc of polymethylmethacrylate (PMMA) was injected into the each vertebral body through transpedicular route. All patients underwent one level interbody fusion and pedicular screw fixation. Clinical outcome was assessed using Oswestry Disability Index (ODI) on the last clinical follow-up. In addition, a modified MacNab's grading criteria was used to objectively assess patient's outcome postoperatively. Radiographic analysis of sagittal contour was assessed preoperatively, immediately postoperatively, and at final follow-up including fusion rate. Results : Eighteen of 20 patients were graded as excellent or good according to the modified MacNab's criteria. An significant improvement of ODI was achieved in both groups. Mean sagittal angle at the preoperative state, postoperative state and at the last follow-up state was $11.0^{\circ},\;20.1^{\circ}$ and $18.3^{\circ}$, respectively, with mean sagittal angle correction gain $7.3^{\circ}$. Firm fusion was achieved in all patients. There were one compression fracture above the fused segment after 6 months follow-up and one case of seroma. But there were no postoperative complications related to bone cement leakage and pedicular screwings such as screw pullout or screw cut-up. Conclusion : Bone cement augmentation of pedicular screwing can be an effective procedure for osteoporotic lumbar spine in spondylolisthetic patients.