• 제목/요약/키워드: Bone screw

검색결과 437건 처리시간 0.026초

유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석 (Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

ZrN 및 TiN 코팅된 치과교정 용 미니나사의 표면특성과 전기화학적 거동 (Surface Characteristics and Electrochemical Behaviors of TiN and ZrN Coated Orthodontic Mini-screw)

  • 김신영;문영필;박근형;조호형;김원기;손미경;최한철
    • 한국표면공학회지
    • /
    • 제41권5호
    • /
    • pp.232-239
    • /
    • 2008
  • The dental orthodontic mini-screw requires good mechanical properties and high corrosion resistance for implantation in the bone. The purpose of this study was to investigate the electrochemical characteristics of TiN and ZrN coated orthodontic mini-screws, mini-screws were used for experiment. Ion plating was carried out for mini-screw using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen w as o bserved with f ield emission scanning e lectron microscopy ( FE-SEM), e nergy dispersive x-ray spectroscopy (EDX), and electrochemical tester. The surface of TiN and ZrN coated mini-screw were more smooth than that of other kinds of non-coated mini-screw due to dercrease of machined defects. The corrosion current density of the TiN and ZrN coated mini-screw decreased compared to non-coated sample. The corrosion potential of TiN and ZrN coated mini-screw were higher than that of non-coated mini-screw in 0.9% NaCl solution. The pitting corrosion resistance increased in the order of ZrN coated, TiN coated and non-coated wire. Pitting potential of ZrN coated mini-screw was the highest in the other specimens.

요추전방전위증 환자들에서 후방요추체간유합술로 자가골편 또는 Cage를 사용한 두 군간의 비교 (Comparision of the Two Groups between Autologous Bone Chips and Cage as Posterior Lumbar Interbody Fusion in Spondylolisthesis Patients)

  • 신필재;김창현;문재곤;이호국;황도윤
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권4호
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : Posterior lumbar interbody fusion(PLIF) with transpedicular screw fixation(TPSF) have many merits in the treatment of spondylolisthesis. The aim of this study was to compare cage PLIF group(PLIF using cage and TPSF) with chip PLIF group(PLIF using autologous bone chips and TPSF) as surgical treatment of spondyloisthesis. Methods : PLIF and TPSF were performed in 44 patients with spondylolisthesis from January 1994 to December 1998. The surgical methods were divided into two groups. One group was cage PLIF(20 patients), and the other group was chip PLIF(24 patients). We analyzed the change of anterior translation, change of intervertebral space height, fusion rate, clinical outcomes, and postoperative complications in two groups. Result : There was no significant difference in reduction and maintenance of anterior translation between two groups. Intervertebral space height was increased in the two groups at immediate postoperative state. At last followup, it was decreased compared to preoperative height in chip PLIF group. In cage PLIF group, last follow-up height was decreased compared to immedate postoperative height, but it was significantly increased compared to preoperative height. Fusion rates were 70.9% and 90% in chip PLIF group and cage PLIF group, respectively. Excellent and good clinical outcomes were 79.2% in chip PLIF group and 85% in cage PLIF group, but there was no statistical significance. Complications were screw fracture(1 case), CSF leakage(1 case) in chip PLIF group and screw loosening and retropulsion of cage(1 case), CSF leakage(2 cases) in cage PLIF group. Conclusion : PLIF using cage is better than PLIF using autologous bone chips in the maintenance of intervertebral space height and fusion rate. But there is no statistical difference of the clinical outcomes between the two groups. Further studies, especially on long term follow-up, should be considered.

  • PDF

임플란트 매식 시 수직골 높이에 따른 응력분석 (Stress analysis according to the vertical bone level in the implant placement)

  • 김민호;박영록;계기성
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.

3차원 유한 요소법을 이용한 골절판의 응력 해석 (Numerical Stress Analysis of bone plate System using 3-dimensional finite element method)

  • 김현수;권영수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 춘계학술대회
    • /
    • pp.74-78
    • /
    • 1991
  • Conventional compression bone fracture plates sometimes cause osteoporosis under the plate due to their high rigidity which in turn transfer physiological load mostly through the plates and screws. In order to prevent the osteopenia we have designed a system which have a viscoelastic washer between plate and screw head. The washer is made of a biocompatible ploymer (untra high molecular weight polyethylene, UHMWPE). Three-dimensional finite element meshes of the human femur with the conventional and new concept bone plate ere generated and the comparative stress analyses are performed with static half-stance loading condition. The results of analyses showed that could reduce the stress shielding effect compared with the conventional plate.

  • PDF

Histomorphometric Analysis of Two Types of Coated Implants : a Preliminary Study Using the Rabbit Tibia Model

  • Yeo, In-Sung;Lee, Hyo-Jung
    • Journal of Korean Dental Science
    • /
    • 제2권1호
    • /
    • pp.28-30
    • /
    • 2009
  • Purpose : The purpose of this pilot experiment was to evaluate early bone response in two types of coated implants using the rabbit tibia model. Materials and Methods : Screw type titanium implants manufactured with a calcium metaphosphate (CMP) coating and hydroxyapatite (HA) coating were placed in the tibiae of 3 New Zealand White rabbits. The bone responses at 2 weeks after insertion were evaluated and compared by histomorphometry. Results : There was no significant difference in bone-to-implant contact between the groups (P>.05). However, some qualitative differences on histologic views were found. Conclusions : CMP-coating is suggested to be the preferred candidate for fast osseointegration over HAcoating.

  • PDF

자가 슬개건을 이용한 전방십자인대 재건술 시 경골터널 생성중 핵심 확공기의 파열 - 증례보고 - (Breakage of Core Reamer During Anterior Cruciate Ligament Reconstruction -A Case Report-)

  • 노정호;양보규;박정태;제민수
    • 대한관절경학회지
    • /
    • 제14권1호
    • /
    • pp.33-35
    • /
    • 2010
  • This is a case of the core reamer breakage during anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. A 19-year-old man with acute anterior cruciate ligament rupture had reconstruction surgery. During tunneling in the proximal tibia, the core reamer have been cracked open and broken. Rest of the procedure was performed routinely except the tibial sided fixation of bone block which was performed with larger interference screw than usual. The patient followed the accelerated rehabilitation program. The result was satisfactory at 2 years after surgery.

  • PDF

인공치아에 있어 피질골의 두께 변화가 미치는 영향에 관한 연구 (A Numerical Study for the Variation of Cortical Bone Thickness with Several Dental Implants)

  • 최재봉;문항진;최귀원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.323-326
    • /
    • 1996
  • Dental implant is increasingly used to recover the mastication function of tooth. Several types of implant were designed to give an optimal stress distribution in surrounding bony regions. In this study, six types of implant were investigated using finite element method and it was studied i) how the variation of cortical bone thickness affects the stress distribution in surrounding bony regions depending upon implant types, ii) which type gives the best characteristics in the sence of stress distribution and stability. The hybrid-type implant with cylinder and screw gave the optimum properties in view of stability and response to the variation of cortical bone thickness.

  • PDF

Corticotomy for orthodontic tooth movement

  • Lee, Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권6호
    • /
    • pp.251-258
    • /
    • 2018
  • Corticotomy was introduced as a surgical procedure to shorten orthodontic treatment time. Corticotomy removes the cortical bone that strongly resists orthodontic force in the jaw and keeps the marrow bone to maintain blood circulation and continuity of bone tissues to reduce risk of necrosis and facilitate tooth movement. In the 21st century, the concept of regional acceleratory phenomenon was introduced and the development of the skeletal anchorage system using screw and plate enabled application of orthopedic force beyond conventional orthodontic force, so corticotomy has been applied to more cases. Also, various modified methods of minimally invasive techniques have been introduced to reduce the patient's discomfort due to surgical intervention and complications after surgery. We will review the history of corticotomy, its mechanism of action, and various modified procedures and indications.

슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기- (Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note-)

  • 인용;박원종;박종범;홍승환
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.60-63
    • /
    • 2002
  • 목적 : 네 겹의 슬괵건을 이용한 전방십자인대 재건술시 대퇴터널을 횡고정 핀과 흡수성 간섭나사로 함께 고정하는 수기를 소개하고자 한다. 수술 술기 : 반건양건과 박건을 채취하여 네 겹으로 준비하였다. 경골터널과 대퇴터널을 만드는데 대퇴터널의 깊이는 35 mm로 하였다. Rigidfix system의 가이드를 삽입하고 가이드의 위쪽 관에만 구멍을 내었다. 이식건을 통과시킨후 횡고정 핀 을 고정하였다. 이후 이식건을 경골쪽으로 당기면서 흡수성 간섭 나사로 고정하였다. 결론 : 슬괵건 전방십자인대 재건술시 횡고정 핀과 흡수성 간섭나사를 이용한 대퇴터널 고정은 강한 초기 고정과 이식건의 골통합을 촉진시킬 수 있는 좋은 방법으로 사료되어 소개하였다.

  • PDF