• 제목/요약/키워드: Bone screw

검색결과 437건 처리시간 0.024초

경도-중등도 무지외반증 환자의 생체 흡수성 마그네슘 나사못과 티타늄 나사못을 사용한 수술의 단기 결과 비교 (Comparing the Results of Using Bioabsorbable Magnesium Screw with Those Using a Titanium Screw for the Treatment of Mild to Moderate Hallux Valgus: Short-term Follow-Up)

  • 홍성엽;김갑래;한우솔
    • 대한족부족관절학회지
    • /
    • 제24권3호
    • /
    • pp.107-112
    • /
    • 2020
  • Purpose: Hallux valgus (HV) is a common foot deformity that causes pain in the first metatarsophalangeal joint. Distal metatarsal osteotomies are commonly performed as a treatment. This retrospective study compared the clinical and radiological results of bioabsorbable magnesium (Mg) versus titanium (Ti) screw fixation for modified distal chevron osteotomy in HV. Materials and Methods: Forty-nine patients, who underwent modified distal chevron osteotomy for HV in 2018 and 2019, were reviewed retrospectively. Bioabsorbable Mg screw fixation was applied in 20 patients (22 feet), and a traditional Ti compression screw was applied in 29 patients (40 feet). The patients were followed up for at least six months. The clinical results were evaluated using the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal (AOFAS-MTP-IP) scale and a visual analogue scale (VAS). The hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) were measured before, after surgery, and at the six months follow-up. Results: The AOFAS-MTP-IP scale and VAS points were improved in both groups, with no significant difference between them. At the six-month follow-up, HVA, IMA, and DMAA were similar. Bone union was confirmed in both groups, and there were no significant major complications in both groups. Four people in the Ti screw group underwent implant removal surgery. Conclusion: Bioabsorbable Mg screws showed comparable clinical, radiologic results to Ti standard screws six months after distal modified chevron osteotomy. These screws are an alternative fixation material that can be used safely and avoid the need for implant removal operations.

Carpal Bone Segmentation Using Modified Multi-Seed Based Region Growing

  • Choi, Kyung-Min;Kim, Sung-Min;Kim, Young-Soo;Kim, In-Young;Kim, Sun-Il
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.332-337
    • /
    • 2007
  • In the early twenty-first century, minimally invasive surgery is the mainstay of various kinds of surgical fields. Surgeons gave percutaneously surgical treatment of the screw directly using a fluoroscopic view in the past. The latest date, they began to operate the fractured carpal bone surgery using Computerized Tomography (CT). Carpal bones composed of wrist joint consist of eight small bones which have hexahedron and sponge shape. Because of these shape, it is difficult to grasp the shape of carpal bones using only CT image data. Although several image segmentation studies have been conducted with carpal bone CT image data, more studies about carpal bone using CT data are still required. Especially, to apply the software implemented from the studies to clinical fIeld, the outcomes should be user friendly and very accurate. To satisfy those conditions, we propose modified multi-seed region growing segmentation method which uses simple threshold and the canny edge detector for finding edge information more accurately. This method is able to use very easily and gives us high accuracy and high speed for extracting the edge information of carpal bones. Especially, using multi-seed points, multi-bone objects of the carpal bone are extracted simultaneously.

Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가 (EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS)

  • 박지현;황순정;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

총상 골절 개에서 자가골 이식과 주관절 고정술 (Elbow Arthrodesis with bone Autograft for the Management of Gunshot Fracture in a Dog)

  • 이종일;알람;김남수
    • 한국임상수의학회지
    • /
    • 제22권1호
    • /
    • pp.60-64
    • /
    • 2005
  • 체중 23kg, 나이 6세된 수캐 잡종 사냥개가 왼쪽 주관절에 총상을 입어 전북대학교 수의과대학 동물병원에 내원하였다. 방사선 사진에서 요골 척골 근위부에 복잡골절과 주관절 돌기 후방에 금속성 탄환이 발견되었다. 첫 번째 외과처치는 탄환을 제거하고 bone plate, bone screw, K-wire등을 이용하여 정복 고정하였으나 실패하였다. 두 번째 시도는 주관철 고정술과 13번째 늑골로부터 얻은 자가골을 이용하여 결손부를 충진 하였다. 결과가 만족스럽지 못하여 자가골 재이식과 3번째 수술을 실시하여 주관절의 안정된 고정상태를 유지 할 수 있었다. 60주가 지난 현재 평상시 활동에는 커다란 문제점이 없지만 속보 혹은 뛰는 경우 관절 고정술을 실시한 다리를 들고 세 다리만 사용하는 아쉬움이 있다.

치과용 골유착성 임플랜트 고정체 형상의 응력 분산에 관한 연구 (STUDIES OF OSSEOINTEGRATED IMPLANT-MODELS ON STRESS DISTRIBUTION)

  • 한종현;전흥재;정신영;허성주;최용창;정종평;구영;류인철;김명호
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.526-543
    • /
    • 2000
  • Finite element analyses were performed to study effects on stress distribution generated in jaw bone for various shapes of dental implants: plateau type, plateau with small radius of curvature, triangular thread screw type in accordance with ISO regulations and square thread screw filleted with small radius partially. It was found that square thread screw filleted with small radius was more effective on stress distribution than other dental implants used in analyses. Additional analyses were performed on the implant with square thread screw filleted with small radius for very-ing design parameters, such as the width of thread end, the height of the thread of the implant and load direction, to determine the optimum dimensions of the implant. The highest stress concentration occurred at the region in jaw Pone adjacent to the first thread of the implant. The maximum effective stress induced by a 15 degree oblique load of 100 N was twice as high as the maximum effective stress caused by an equal amount of vertical load. Stress distribution was more effective in the case when the width of thread end and the height of thread were p/2 and 0.46p, respectively, where p is the pitch of thread. At last, using tensile force calculated from the possible insert torque without breading bone thread, finite element analysis was performed on the implant to calculate pre-stress when the primary fixation of the implant was operated in jaw bone. The maximum effective stress was 136.8 MPa which was proven to be safe.

  • PDF

경거골유합술 후 발생하는 불유합과 관련된 인자에 대한 분석 (Analysis about Associated Factors of Nonunion Following Tibiotalar Arthrodesis)

  • 이준영;김보선;이정우
    • 대한족부족관절학회지
    • /
    • 제21권3호
    • /
    • pp.98-103
    • /
    • 2017
  • Purpose: The aim of this study was to analyze the factors related to nonunion in tibiotalar arthrodesis. Materials and Methods: Eighty cases of ankle arthritis treated with tibiotalar arthrodesis in our hospital from November 2008 to November 2015 with more than one year follow up were analyzed. Simple anteroposterior and lateral radiographs after 6 and 12 months of surgery were analyzed. Union was defined as more than 50% connection of the trabecular bone at the ankle joint surface in the anteroposterior and lateral radiographs. The nonunion group was defined as no signs of union with persistent pain 9 months after surgery. The surgical approach, type of used screw, preoperative and postoperative ankle alignment, body mass index (BMI), bone mineral density, and patients' prior history were compared between the two groups. Results: There were 69 union cases and 11 nonunion cases. In the patient factors, the gender and BMI was related to nonunion (p<0.05). The mean preoperative and postoperative ankle alignment in the nonunion group was $9.93^{\circ}{\pm}6.92^{\circ}$ and $5.43^{\circ}{\pm}3.35^{\circ}$ respectively, and $9.80^{\circ}{\pm}7.55^{\circ}$ and $5.63^{\circ}{\pm}3.45^{\circ}$ in the union group, respectively; the difference was not statistically significant (p>0.05). In the technical factors, the transfibular approach showed a better relationship but the association was not significant (p<0.05). In 40 cases of the transfibular approach, 12 cases used cancellous screws, and 4 cases showed nonunion due to screw breakage. Conclusion: Technical factors, such as the surgical approach and the type of screw used can be a risk factor in nonunion. In addition, patients' factors, such as gender and BMI, must be considered to reduce the nonunion rate.

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • 제13권6호
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.

혈소판 유래 성장인자가 임플란트 주위 골형성에 미치는 효과에 대한 실험적 연구 (AN EXPERIMENTAL STUDY OF PLATELET-DERIVED GROWTH FACTOR ABOUT BONE FORMATION IN DENTAL IMPLANT)

  • 류재준;권종진;김한겸
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.816-831
    • /
    • 1998
  • Bony fixation of implants during the early phase of healing is important in order to get secondary stability of the implant assuring the success of the treatment. Because the successful placement of the implant is limited by the quality and quantity of bone, other agents which stimulate bone formation in the peri-implant spaces has been illustrated. Platelet-derived growth factor (PDGF) has been shown to regulate DNA and protein synthesis in bone cells in vitro and to interact synergistically to enhance soft tissue wound healing in vivo. The purpose of this study was to evaluate bone promotion around implants which were augmented with sagittal split osteotomy or autogenous veneer bone graft using the platelet derived growth factor(PDGF). After placement of newly designed twenty four screw-type implants, which were 12mm in length and 4mm in diameter in 6 dogs. $4{\mu}g$ of PDGF B/B was applied with surgicel carriers. The dogs were sacrificed at 3 days, 1, 2, 3, 6, and 12 weeks after implantation. Specimens were examined clinically, radiographically, histologically, and histomorphometrically. The results were as follows: 1. Clinically and radiologically, there was no significant difference in bone formation and healing pattern between experimental and control group. 2. In autogenous veneer bone graft group, bone formation was observed at 1st week in the experimental groups but 2nd week in the control groups. At 3rd week, the expeimental groups showed more bone formation comparing to the control groups. 3. In sagittal split osteotomy group, bone formation was observed at 1st week in both groups. But the experimental groups showed more bone formation comparing to the control groups after 2nd week. 4. The bone growth rate of experimental group was more rapid than that of control group. These results indicated that PDGF did not affect the initiation of new bone formation, but it accelerated the bone formation at the early period.

  • PDF

골연부 종양에서 저온 열처리한 자가골을 이용한 재건술 (Autogenous Low Heat Treated Bone Graft for Bone Reconstruction in Bone and Soft Tissue Tumors)

  • 전대근;이종석;김석준;조완형;곽봉준;이수용
    • 대한골관절종양학회지
    • /
    • 제4권2호
    • /
    • pp.81-87
    • /
    • 1998
  • Although autoclaved autogenous bone reconstruction is one of the established procedures, it may have some problems in bone regeneration and mechanical property. The purpose of this study is to evaluate the efficacy of more biologic and anatomical reconstruction where allograft is not readily available. From Aug.1991 to Feb. 1996 the authors analyzed 32 cases of reconstruction with autogenous low heat treated bone. Autogenous graft sites were humerus 4, tibia 4, pelvis 9, and 15 femur. Average follow-up period was 23(range;12-51) months. There were 49 graft-host junctional sites. Diaphysis was 22, metaphysis 10, and flat bone 17. Average duration of healing for the 38 united sites was 7 months. Average union time for each anatomical area 8 months in 19 diaphysis, 12 months in 7 metaphysis, and 12.7 months in 12 flat bone(pelvis). Eleven nonunion sites consisted of 3 diaphysis(3/22), 3 metaphysis(3/10), and 5 flat bone(5/17). Complications other than nonunion were local recurrence(4), bone resorption(3), graft fracture(2), osteomyelitis(1), metal failure(2), and wound infection(1). Initial bone quality and stable fixation technique was important for union rate. Plate and screw is a good method for diaphyseal lesion. Metaphyseal and flat bone are weak area for rigid fixation and one stage augmentation with iliac bone graft can be a salvage procedure.

  • PDF

관절경적 전방십자인대 재건술시에 골-슬개건-골과 네가닥 반건양건-박건을 이용한 방법의 비교연구 (Comparative Study of Arthroscopic ACL Reconstruction Using Bone-Patellar Tendon-Bone Versus Four-Stranded Semitendinosus-Gracilis Tendon)

  • 김진구;임영;김병직;고한석;문형태
    • 대한관절경학회지
    • /
    • 제2권2호
    • /
    • pp.107-113
    • /
    • 1998
  • This study is retrospective analysis of 31 patients treated by arthroscopically assisted ACL reconstruction, from September 1995 to September 1996. ACL reconstructions using autogenous bone patellar tendon bone (B-PT-B) were done in 18 patients, and using hamstring tendon were done in 13 patients. We used four-stranded hamstring tendon grafts and fixed the grafts using Endobutton and screw. The mean postoperative Lysholm knee score was 87.2 points in B-PT-B. group, and 89.0 points in hamstring tendon group. There were no clinically significant results between two groups in Telos test, quadriceps atrophy, Lachman test, anterior drawer test and pivot shift test, but the incidences of anterior knee pain were lower in hamstring group. Four-stranded hamstring tendon graft showed enough stability and good functional outcome similar to that of patellar tendon graft, and had an advantage of quicker return of quadriceps function and less donor site morbidity.

  • PDF