• Title/Summary/Keyword: Bone screw

Search Result 439, Processing Time 0.032 seconds

Three dimensional finite element analysis of the stress on supporting bone by the abutment materials of dental implant (치과용 임플란트 지대주 재료에 따른 지지골 응력의 3차원 유한요소 분석)

  • Lee, Myung-Kon;Kim, Kap-Jin
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze the biomechanical properties of the dental implants on the supporting bone using three-dimensional finite element method when three different abutment materials were applied to the implant system. Methods: Three different dental implant models were fabricated by applying Ti, PEEK, and CRE-PEEK (60% carbon-reinforced PEEK) to abutment material. The abutment and connecting screw from the fixture was applied with a tightening torque of 20 Ncm. And then, total loads of 150 N were applied in an $30^{\circ}oblique$ direction (to the vertical). The structural stability of dental implants on the supporting bone was analyzed using Von Mises stress and principal stress values. Results: The maximum tensile stress of the cortical bone was highest at 12.6 MPa in the PEEK abutment (Model-B). Ti abutment (Model-A) and CRE-PEEK abutment (Model-C) showed similar stress distributions (10.6 and 10.3 MPa, respectively). And the maximum compressive principal stress was similar in all models. The Von Mises stress value delivered to the bone around the implant was highest at 16.5 MPa in Model-B. On the other hand, Model-A and C showed similar stress distributions (14.0 and 13.8 MPa, respectively). In addition, the maximum equivalent stress applied to the abutment was highest at 629.8 MPa in Model-A. The stress distribution in Model-C was 573.9 MPa. Whereas, Model-B showed the lowest value at 165.6 MPa. Conclusion : The dental implant supporting bone system using PEEK material seems to have the possibility of supporting bone fracture. It was found that the CRE-PEEK abutment can reduce the elastic deformation and reduce the stress value of the interfacial bone.

STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS (상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석)

  • Kim, Han-Koo;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

The Effect of Repetitive Insertion and Pullout of Spinal Screws on Pullout Resistance : A Biomechanical Study (척추 수술에 사용되는 나사못의 반복 삽입과 인출이 인장항력에 미치는 영향 : 생체 역학적 연구)

  • Bak, Koang Hum;Ferrara, Lisa;Kim, Kwang Jin;Kim, Jae Min;Kim, Choong Hyun;Benzel, Edward C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.131-136
    • /
    • 2001
  • Object : The clinical uses of screws are increasing with broader applications in spinal disorders. When screws are inserted repeatedly to achieve optimal position, tips of screw pitch may become damaged during insertion even though there are significant differences in the moduli of elasticity between bone and titanium. The effect of repeated screw insertion on pullout resistance was investigated. Methods : Three different titanium screws(cortical lateral mass screw, cancellous lateral mass screw and cervical vertebral body screw) were inserted into the synthetic cancellous material and then extracted axially at a rate of 2.4mm/min using Instron(Model TT-D, Canton, MA). Each set of screws was inserted and pulled out three times. There were six screws in each group. The insertional torque was measured with a torque wrench during insertion. Pullout strength was recorded with a digital oscilloscope. Results : The mean pullout force measurements for the cortical lateral mass screws($185.66N{\pm}42.60$, $167.10N{\pm}27.01$ and $162.52 N{\pm}23.83$ for first, second and third pullout respectively : p=0.03) and the cervical vertebral body screws($386.0N{\pm}24.1$, $360.2N{\pm}17.5$ and $330.9N{\pm}16.7$ : p=0.0024) showed consecutive decrease in pullout resistance after each pullout, whereas the cancellous lateral mass screws did not($194.00N{\pm}36.47$, $219.24N{\pm}26.58$ and 199.49N(36.63 : p=0.24). The SEM after insertion and pullout three times showed a blunting in the tip of the screw pitch and a smearing of the screw surface. Conclusions : Repetitive screw insertion and pullout resulted in the decrease of pullout resistance in certain screws possibly caused by blunting the screw tip. This means screw tips suffer deformations during either repeated insertion or pullout. Thus, the screws that have been inserted should not be used for the final construct.

  • PDF

Improvement of fibrosed scar tissue elongation using self-inflatable expander

  • Jung, Gyu-Un;Kim, Jin-Woo;Pang, Eun-Kyoung;Kim, Sun-Jong
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.501-512
    • /
    • 2016
  • We evaluated a self-inflatable osmotic tissue expander for its utility in creating sufficient soft tissue elongation for primary closure after bone grafting. Six patients with alveolar defects who required vertical augmentation of >6 mm before implant placement were enrolled. All had more than three prior surgeries, and flap advancement for primary coverage was restricted by severely fibrosed scars. Expanders were inserted beneath the flap and fixed with a screw. After 4 weeks, expander removal and bone grafting were performed simultaneously. A vertical block autograft and guided bone regeneration and distraction osteogenesis were performed. Expansion was sufficient to cover the grafted area without additional periosteal incision. Complications included mucosal perforation and displacement of the expander. All augmentation procedures healed uneventfully and the osseous implants were successfully placed. The tissue expander may facilitate primary closure by increasing soft tissue volume. In our experience, this device is effective, rapid, and minimally invasive, especially in fibrous scar tissue.

  • PDF

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

Finite Element Analysis of Supporting Bone according to Custom Abutment Angles (맞춤형 지대주 각도에 따른 지지골의 유한요소 분석)

  • Nam, Min-Gyeong;Kim, Nam-Sic
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.115-120
    • /
    • 2015
  • Purpose: The purpose of this study is a finite element analysis of supporting bone according to custom abutment angle. Methods: Implant fixture was selected with a diameter of 4 mm and the length of 13 mm. The fixture and abutment was designed by a combination of the abutment screw clamping force to produce a custom abutment model of $0^{\circ}$, $15^{\circ}$, $25^{\circ}$ and $35^{\circ}$. The loading condition of 176 N was applied to the lingual surface of the crown, near to the incisor edge, and horizontal load. An oblique load of $90^{\circ}$ was applied long axis of the implant fixture analyze the stress of supporting bone. Results: The result of mechanical analysis was observed that the supporting bone stress analysis of the horizontal load, the von Mises stress values (MPa) are given in the order of TH00 (432.6) > TH25 (418.0) > TH15 (417.4) > TH35 (415.8), the oblique load, the von Mises stress values are given in the order of TO00 (459.3) > TO15 (399.6) > TO25 (374.8) > TO35 (343.4) Conclusion: The $35^{\circ}$ abutment over the current clinical tolerance limits will be available for clinical application.

EFFECT OF VARIOUS INODIZING CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANT SURFACE DESIGN (다양한 양극산화막 처리방법이 임프란트 골유착에 미치는 영향)

  • Cha, Soo-Ryun;Lee, Jun;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.417-427
    • /
    • 2008
  • The aim of this study is to investigate the effect of anodizing surface to osseointegration of implant by using of resonance frequency analysis (RFA), quantitative and qualitative assessment of an anodically modified implant type with regard to osseous healing qualities. A total of 96 screw-shaped implants were prepared for this study. 72 implants were prepared by electrochemical oxidation with different ways. 24 (group 1 SP) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid. 24 (group 2GC) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate and 24 (group 3 CMP (Calcium Metaphosphate) Coating were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by CMP coating. Rest of 24 (control group were as a control group of RBM surface. Bone tissue responses were evaluated by resonance frequency analysis (RFA) that were undertaken at 2, 4 and 6 weeks after implant placement in the mandible of mini-pig. Group 1 SP (anodized with sulfuric acid and phosphoric acid implants) demonstrated slightly stronger bone responses than control Group RBM. Group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) demonstrated no difference which were compared with control group. Group 3 GMP (anodized and CMP coated implants) demonstrated slightly stronger and faster bone responses than any other implants. But, all observation result of RF A showed no significant differences between experimental groups with various surface type. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for group 2 GC. Significantly more bone formation was found inside threaded area for group 2 GC. It was concluded that group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) showed more effects on the bone tissue responses than RBM surface in initial period of implantation. In addition, CMP showed a tendency to promote bone tissue responses.

Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity

  • Oh, Hyun-Ju;Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.283-291
    • /
    • 2018
  • Objective: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. Methods: Four male beagle dogs were used for this study. Six orthodontic miniscrews were placed in the interradicular spaces in the posterior mandible of each dog (n = 24). The implanted miniscrews were classified into no loading, immediate loading, and delayed loading groups according to the loading time. At 6 weeks after screw placement, the animals were sacrificed, and tissue blocks including the miniscrews were harvested for histological examinations. After analysis of the histological sections, the miniscrews were categorized into three additional groups according to the root proximity: high root proximity, low root proximity, and safe distance groups. Differences in the bone-implant contact (BIC, %) among the root proximity groups and loading time groups were determined using statistical analyses. Results: No BIC was observed within the bundle bone invaded by the miniscrew threads. Narrowing of the periodontal ligament space was observed in cases where the miniscrew threads touched the bundle bone. BIC (%) was significantly lower in the high root proximity group than in the low root proximity and safe distance groups. However, BIC (%) showed no significant differences among the loading time groups. Conclusions: Regardless of the loading time, the stability of an orthodontic miniscrew is decreased if it is in contact with the bundle bone as well as the adjacent tooth root.

The Experimental Study of Effects of Irradiation on Osseointegration (방사선조사가 임프란트의 골유착에 미치는 영향에 관한 실험적 연구)

  • Park Kwan-Soo;Lee Sang-Rae;Hwang Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.119-147
    • /
    • 1999
  • The purpose of this study was to investigate the effects of the Co-60 γ irradiation on the osseointegration. 2.0 mm titanium alloy screw implants(Sankin Industry Co. Ltd., Japan) were placed in the tibial metaphysis of the rabbits, bilaterally. The mean length of the implants was 6.0 mm. The right tibia was irradiated with a single dose of 15Gy from 60Co teletherapic machine at 5th postoperative day. The experimental group was irradiated tibia. The control group was non­irradiated tibia. To observe the phase of bone formation, the bone labeling by intramuscular injection of 20mg/Kg of Tetracycline, Calcein, Alizarin red S, was performed. The rabbits were sacrificed on the 1st, 2nd, 4th, 6th, 8th week and the tibia including implants were taken, and then the specimens were examined by the microradiography, light microscopy, and fluorescent microscopy. The obtained results were as follows: 1. There were connective tissue between bone and titanium at 1st week, in both group. Especially, the many empty lacunae without nucleus and obscure cytoplasm in experimental group, were observed. 2. The osteons were observed at 4th week in control group, and at 6th week in experimental group. The bone formation in experimental group was retarded as compared to the control group. 3. In fluorescent microscopy, bone labelling band was observed as linear, arc or concentric shape. Occasionary interrupted labelling band was observed, which is demonstrated bone remodeling. 4. In microradiographic examination, the radiolucent image was found between bone and implant with widening of bone marrow spaces as compared to the control group.

  • PDF

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.