• Title/Summary/Keyword: Bone processing

Search Result 202, Processing Time 0.025 seconds

Effect of Age and Caponization on Blood Parameters and Bone Development of Male Native Chickens in Taiwan

  • Lin, Cheng-Yung;Hsu, Jenn-Chung;Wan, Tien-Chun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.7
    • /
    • pp.994-1002
    • /
    • 2012
  • An experiment was carried out to determine the effect of age and caponization on the development blood and bone characteristics development in male country chickens in Taiwan. A total of two hundred 8-wk-old LRI native chicken cockerels, Taishi meat No.13 from LRI-COA, were used as experimental animals. Cockerels were surgically caponized at 8 wks of age. Twelve birds in each group were bled and dressed from 8 wks to 35 wks of age at 1 to 5 wk intervals. The results indicated that the plasma testosterone concentration was significantly (p<0.05) lower in capons after 12 wks of age (caponized treatment after 4 wks) than that of the intact males. The relative tibia weight, bone breaking strength, cortical thickness, bone ash, bone calcium, bone phosphorus and bone magnesium contents were significantly (p<0.05) higher in intact males, while capons had higher (p<0.05) plasma ionized calcium, inorganic phosphorus and alkaline phosphatase concentration. The plasma testosterone concentration, relative tibia weight, tibia length, breaking strength, cortical thickness, bone ash, calcium, and phosphorus contents of intact males chickens increased significantly (p<0.05) with the advance of age. In addition, the relative tibia weight of capons peaked at 18 wks of age, and declined at 35 wks of age. The bone ash, calcium and phosphorus content increased most after 14 wks of age in male native chickens in Taiwan. Also, tibia length and cortical thickness peaked at 22 wks of age. However, the peak of bone strength was found at 26 wks of age. These findings support the assertion that androgens can directly influence bone composition fluxes in male chickens. Caponization caused a significant increase in bone loss at 4 wks post treatment, which reflected bone cell damage, and demonstrated reductions in the relative tibia weight, breaking strength, cortical thickness, bone ash, calcium, phosphorus and magnesium contents, and increases in plasma ionized calcium, inorganic phosphorus and alkaline phosphatase concentration.

AN EXPERIMENTAL STUDY ON THE FREEZE-DRIED BONE OF MAXILLA AND MANDIBLE IN KOREANS ;I. A microbiologic study of the sterility on the fresh-frozen and freeze-dried bone of human (동결 건조한 한국인 상하악골에 대한 실험적 연구;I. 단순냉동 및 냉동 건조된 동종골의 멸균에 관한 실험적 연구)

  • Um, In-Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.405-411
    • /
    • 1991
  • To determine the sterility of the prepared allogeneic bone of the human, culture of the allografts prior to implantation was performed on fresh-frozen and freeze-dried bone. Before the use of allografts to the patients, it must be confirmed about the sterility, cellular cytotoxicity, immune reaction, and osteoinductive potential as a biomaterials. Oral and maxillofacial surgeons demand for allograft bone will be increased in the future. Wonkwang Bone Bank attempted to meet this demand, has performed series of experimental study on the allograft bone of the Koreans to evaluate the physical and chemical suitability of the bone since the surgeons applications will have broadened from benign cystic lesions to fracture malunions and non-unions, large segmental defects, and whole-bone allorgrafts after tumor surgery. The results obtained were as follows: 1. Freeze-drying(FD) only shoed some bactericidal effects of the normal and osteo bone but in cases of performing EO gas sterilization, the FD effects was not clear. 2. The fact that FD has little effect than the EO gas sterilization on normal bone postulated that the presence of microbiota may be due to an operation and bone processing procedure. 3. FD and EO gas sterilization had a remarkable effect on the osteo bone. 4. The sterilization effect were EO gas, Freeze-drying, Fresh-Frozen with descending order. But all sterilization method were not complete to preserve and implant allograft bone. We are now performing further continuous study on the radiation and chemical sterilization procedure to make safe and complete allograft bone.

  • PDF

A Pilot study of poroelastic modulus measurement in micro-bone tissue (미세 골조직의 공극탄성계수 측정을 위한 예비 연구)

  • 박영환;홍정화
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1038-1041
    • /
    • 2004
  • In this study, developed a micro-level experimental setup to measure pore pressure and poroelastic modulus in various strain and strain rate about a stress in micro-structure of bone tissue. It is essential device in the development of the model to analysis the interstitial bone fluid flow of the lacuno-canalicular system to be known that would effect on the bone remodeling. The constitution of the experimental setup is as follows, microscopic image processing system; actuator control unit; load measurement system. A pilot study was used an artificial chemical wood to have similar poroelastic property of bone matrix and conducted to validate the suitability of the measurement system.

  • PDF

Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy Studies on Processed Tooth Graft Material by Vacuum-ultrasonic Acceleration

  • Lee, Eun-Young;Kim, Eun-Suk;Kim, Kyung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.103-110
    • /
    • 2014
  • Purpose: The current gold standard for clinical jawbone formation involves autogenous bone as a graft material. In addition, demineralized dentin can be an effective graft material. Although demineralized dentin readily induces heterotopic bone formation, conventional decalcification takes three to five days, so, immediate bone grafting after extraction is impossible. This study evaluated the effect of vacuum ultrasonic power on the demineralization and processing of autogenous tooth material and documented the clinical results of rapidly processed autogenous demineralized dentin (ADD) in an alveolar defects patient. Methods: The method involves the demineralization of extracted teeth with detached soft tissues and pulp in 0.6 N HCl for 90 minutes using a heat controlled vacuum-ultrasonic accelerator. The characteristics of processed teeth were evaluated by scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Bone grafting using ADD was performed for narrow ridges augmentation in the mandibular area. Results: The new processing method was completed within two hours regardless of form (powder or block). EDS and SEM uniformly demineralized autotooth biomaterial. After six months, bone remodeling was observed in augmented sites and histological examination showed that ADD particles were well united with new bone. No unusual complications were encountered. Conclusion: This study demonstrates the possibility of preparing autogenous tooth graft materials within two hours, allowing immediate one-day grafting after extraction.

Correlation of bone quality in radiographic images with clinical bone quality classification (방사선사진에서의 골질과 임상적으로 평가한 골질 분류의 상관관계)

  • Kim Hyun-Woo;Huh Kyung-Hoe;Park Kwan-Soo;Kim Jeong-Hwa;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2006
  • Purpose : To investigate the validity of digital image processing on panoramic radiographs in estimating bone quality before endosseous dental implant installation by correlating bone quality in radiographic images with clinical bone quality classification. Materials and Methods : An experienced surgeon assessed and classified bone quality for implant sites with tactile sensation at the time of implant placement. Including fractal dimension eighteen morphologic features of trabecular pattern were examined In each anatomical sites on panoramic radiographs. Finally bone quality of 67 implant sites were evaluated in 42 patients. Results : Pearson correlation analysis showed that three morphologic parameters had weak linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.276, -0.280, and - 0.289, respectively (p<0.05). And other three morphologic parameters had obvious linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.346, -0.488, and -0.343 respectively (p<0.05). Fractal dimension also had a linear correlation with clinical bone quality classification with correlation coefficients -0.506 significantly (p<0.05). Conclusion : This study suggests that fractal and morphometric analysis using digital panoramic radiographs can be used to evaluate bone quality for implant recipient sites.

  • PDF

Influence of bone fracture incidence on the quality of pork semimembranous muscle (골절 발생에 따른 돈육 반막모양근의 품질변화)

  • Jung, Samooel;Lee, Hanhyeon;Hwang, Heetae;Lim, Daewoon;Lee, Chulwoo;Jo, Cheorun
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.2
    • /
    • pp.125-129
    • /
    • 2015
  • This study was conducted to investigate the incidence of bone-fracture from pig carcass slaughtered in eight processing plants located in Daejeon and Chungnam area, Korea, during the year 2013 and 2014, and to evaluate the quality of semimembranous muscle from bone-fractured carcasses. Twenty semimembranous muscles were collected from bone-fractured carcasses and none bone-fractured (control) ones, respectively, after storage of pig carcass at $5^{\circ}C$ for 24 h. The pH, cooking loss, and color of semimembranous muscle were measured as quality parameters. In total 4,865,502 of pig carcasses, the occurrence of bone fracture was 0.328% (15,975 heads) and scored the highest defect (26.31%) in total abnormal carcasses. The pH and cooking loss of semimembranous muscle from bone-fractured carcasses were significantly lower than those of control (p<0.05). $L^*$ and $a^*$ values of semimembranous muscle were not significantly different between bone-fractured carcass and control whereas that of $b^*$ values was significantly higher in bone-fractured carcass than control (p<0.05). Eight out of twenty semimembranous muscle collected from bone-fractured carcasses were confirmed as PSE whereas only one in control. In conclusion, the incidence of bone-fracture pre- and during slaughter of pig may cause serious defects in final meat quality. Therefore, the proper handling and treatment should be implicated to avoid and/or decrease the incidence of bone-fracture of pigs.

Preparation of calcium powder from cooking skipjack tuna bone and its characteristics (자숙 가다랑어뼈로부터 칼슘제의 제조 및 특성)

  • KIM Jin-Soo;CHO Moon-Lae;HEU Min-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.2
    • /
    • pp.158-163
    • /
    • 2000
  • As a part of investigation for utilizing of canned tuna processing by-products as a food resource, we examined the processing conditions and characteristics (extraction methods and ashing condition) of a calcium powder from skipjack tuna bone. Among ashing, autoclaving, and shaking methods for extraction of calcium powder from skipjack tuna bone, ashing method was superior to other methods on the aspect of fish odor, white index, and calcium recovery of calcium powder. Based on the results of white index and soluble calcium ratio, the optimal ashing temperature and time for preparation of a calcium powder from skipjack tuna bone was at $900{\circ}C for 15 min$. Cohesive ratio of calcium powder by shaking at pH 7.0 was increased up to 16 hrs, but after that almost unchanged. Cohesive ratio of calcium powder by shaking for 24 hrs was increased at neutral and alkaline conditions (pH 6-8 and pH 9-11), but almost unchanged at acidic conditions (pH 2-5). For the effective utilization of the calcium powder from skipjack tuna bone, a suitable treatment is needed for improvement of calcium solubility at neutral condition.

  • PDF

Automatic Lower Extremity Vessel Extraction based on Bone Elimination Technique in CT Angiography Images (CT 혈관 조영 영상에서 뼈 소거법 기반의 하지 혈관 자동 추출)

  • Kim, Soo-Kyung;Hong, Helen
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.12
    • /
    • pp.967-976
    • /
    • 2009
  • In this paper, we propose an automatic lower extremity vessel extraction based on rigid registration and bone elimination techniques in CT and CT angiography images. First, automatic partitioning of the lower extremity based on the anatomy is proposed to consider the local movement of the bone. Second, rigid registration based on distance map is performed to estimate the movement of the bone between CT and CT angiography images. Third, bone elimination and vessel masking techniques are proposed to remove bones in CT angiography image and to prevent the vessel near to bone from eroding. Fourth, post-processing based on vessel tracking is proposed to reduce the effect of misalignment and noises like a cartilage. For the evaluation of our method, we performed the visual inspection, accuracy measures and processing time. For visual inspection, the results of applying general subtraction, registered subtraction and proposed method are compared using volume rendering and maximum intensity projection. For accuracy evaluation, intensity distributions of CT angiography image, subtraction based method and proposed method are analyzed. Experimental result shows that bones are accurately eliminated and vessels are robustly extracted without the loss of other structure. The total processing time of thirteen patient datasets was 40 seconds on average.

Extraction of Crude-BMP from Bovine Cortical Bone for Bone Grafts (골이식물로서의 소뼈 치밀골에서 Crude-BMP의 추출)

  • Choi Sung-jin;Park Chul;Heo Soo-young;Lee Jong-il;Jeong In-seong;Kim Nam-soo;Choi In-hyuk
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.377-381
    • /
    • 2005
  • We tried to extract bone morphogenetic protein (BMP) from the freeze-dried bovine cortical bone (FBCB) for bone graft, which were defatted with chloroform-methanol for 20 days, freeze-dried at $-80^{\circ}C$ for 7 days and sterilized by ethylene oxide gas. Two kg of FBCB were pulverized in a wheel mill to $0.5-2.0mm^3$ cubic in size. The bone particles were demineralized in 0.6N HCI for 10 days at chloroform-methanol$4^{\circ}C$ and defatted with chloroform-methanol for 6 hours at room temperature, which was going to be defatting and demineralized cortical bone (DDM). For extracting BMP, DDM was agitated continuously through 72 hours with magnetic stirrer at $4^{\circ}C$ into 12 times of volume of 6 M guanidine hydrochloride (Gdn-HCl) solution containing proteinase inhibitors to protect BMP such as 2mM N-ethylaleimide, 1mM iodoacetic acid, 1mM phenylmethylsulfonyl fluoride and a sterilizer, 1mM sodium azide. The extraction procedure was repeated for three times. All extracted solution was centrifuged at 10,000 rpm for 30 min and then, the supernatant was dialyzed with 12 times of volume of deionized water at $4^{\circ}C$ for 24-72 hours, which cut off below 6,000-8,000 molecular weight. The dialyzed specimen contained crude-BMP was centrifuged, freeze-dried, and weighted. Through these processing, we could obtained $84.9\%$ as FBCB, $17.8\%$ as DDM and $0.71\%$ as crude-BMP from the wet cortical bone without cancellous bone, marrow and muscles. The crude-BMP were obtained $68.3\%$ from the first extraction, $29.6\%$ from secondary and $2.1\%$ from tertiary, respectively. It was suggested that high yield of crude-BMP migth be explained by three-time repetition of the extraction processing for crude-BMP with Gdn-Hcl sol.

A Bone Age Assessment Method Based on Normalized Shape Model (정규화된 형상 모델을 이용한 뼈 나이 측정 방법)

  • Yoo, Ju-Woan;Lee, Jong-Min;Kim, Whoi-Yul
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.3
    • /
    • pp.383-396
    • /
    • 2009
  • Bone age assessment has been widely used in pediatrics to identify endocrine problems of children. Since the number of trained doctors is far less than the demands, there has been numerous requests for automatic estimation of bone age. Therefore, in this paper, we propose an automatic bone age assessment method that utilizes pattern classification techniques. The proposed method consists of three modules; a finger segmentation module, a normalized shape model generation module and a bone age estimation module. The finger segmentation module segments fingers and epiphyseal regions by means of various image processing algorithms. The shape model abstraction module employ ASM to improves the accuracy of feature extraction for bone age estimation. In addition, SVM is used for estimation of bone age. Features for the estimation include the length of bone and the ratios of bone length. We evaluated the performance of the proposed method through statistical analysis by comparing the bone age assessment results by clinical experts and the proposed automatic method. Through the experimental results, the mean error of the assessment was 0.679 year, which was better than the average error acceptable in clinical practice.

  • PDF