• 제목/요약/키워드: Bone drilling

검색결과 70건 처리시간 0.037초

내부냉각(內部冷却) 골천공시(骨穿孔時) 냉각수(冷却水)의 온도(溫度)에 따른 골조직(骨組織)의 병리조직학적(病理組織學的) 변화(變化) (HISTOPATHOLOGIG CHANGES OF THE BONE ON DRILLING WITH DIFFERENT TEMPERATURE SALINE USING INTERNAL IRRIGATION)

  • 박상준;김태규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권3호
    • /
    • pp.8-22
    • /
    • 1990
  • This study was performed to evaluate the histopathologic changes of the rabbit tibial compact bone using internal irrigation with both cold and room - temperature saline on drilling. The medial surface of the rabbit tibia was drilled with specially designed pilot drill (2.0mm in diameter) at 300 rpm. When drilling, two different temperature salines were injected (experimental group I : $4^{\circ}C$ saline, experimental goup Ⅱ : room - temperature saline). And the control group was drilled without cooling agent. The three rabbits in each two experimental and control groups were sacrificed 1, 2, 4, and 8 weeks after. The bone tissues including the bony defects were fixed with 10% neurtal buffered formalin, decalcified with formic acid, embedded in paraplast, and sterile sectioned at 5-6${\mu}m$. And then tissue specimens were stained with H - E and observed under light microscope. The results were as follow : The experimental groups showed early bone repair than the control group at all intervals. They underwent the same course of bone repair until 4 weeks. But the experimental group I showed slightly better bone maturation than the experimental group Ⅱ at 8 weeks.

  • PDF

인조골에서 식립 방법이 교정용 미니 임플란트의 기계적 안정성에 미치는 영향에 대한 예비연구 (The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study)

  • 조일식;추혜란;김성균;신윤섭;김덕수;김성훈;정규림;존황
    • 대한치과교정학회지
    • /
    • 제41권5호
    • /
    • pp.354-360
    • /
    • 2011
  • Objective: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. Methods: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. Results: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. Conclusions: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.

Influence of late removal after treatment on the removal torque of microimplants

  • Kim, Ho-Jin;Park, Hyo-Sang
    • 대한치과교정학회지
    • /
    • 제52권3호
    • /
    • pp.201-209
    • /
    • 2022
  • Objective: To compare the removal torque of microimplants upon post-use removal and post-retention removal and to assess the influencing factors. Methods: The sample group included 241 patients (age, 30.25 ± 12.2 years) with 568 microimplants. They were divided into the post-use (microimplants removed immediately after use or treatment) and post-retention (microimplants removed during the retention period) removal groups. The removal torque in both groups was assessed according to sex, age, placement site and method, and microimplant size. Pearson correlation and multiple linear regression analyses were performed for evaluating variables influencing the removal torque. Results: The mean period of total in-bone stay of microimplants in the post-retention removal group (1,237 days) was approximately two times longer than that in the post-use removal group (656.28 days). The removal torques in the post-retention removal group (range, 4-5 N cm) were also higher than those in the post-use removal group. The mandible and pre-drilling groups demonstrated higher placement and removal torques than did the maxilla and no-drilling groups, respectively. In the no-drilling post-use removal group, the placement torque and microimplant length positively correlated with the removal torque. In the post-retention removal group, unloading in-bone stay period and microimplant diameter positively correlated with the removal torque in the no-drilling and pre-drilling methods, respectively. Conclusions: The removal torques differed according to the orthodontic loading and removal time of microimplants. With prolonged retention of microimplants inserted using the no-drilling method, the removal torque was clinically acceptable and positively correlated with the unloading in-bone stay period.

임플란트 일차 안정성에 있어서 골질에 따른 osteotome 술식의 효과 (The Effect of Osteotome Technique on Primary Implant Stability according to Bone Quality)

  • 백승재;이재관;박찬진
    • Journal of Periodontal and Implant Science
    • /
    • 제35권3호
    • /
    • pp.777-788
    • /
    • 2005
  • The primary stability of implants is an important factor to predict the osseointegration. Recently, the resonance frequency analysis has been used to measure the primary stability. It is an objective method to monitor the stability of implants during healing phase. This study is to validate the differences in the effect of the osteotome method according to the bone quality as well the thickness of cortical bone. Two hundred seventy implants of 3.75mm in diameter(Neoplant, Neobiotech, Korea) were placed in 135 bovine ribs. The bone quality is classified into 3 classes according to the number of bone marrow spaces which implants would be placed, and then classified into 9 subclasses after the ribs were trimmed. Two implants were placed in 15 specimens of each class. The conclusion were as follows: 1. In case of less dense cancellous bone, the oseotome method is more effective in primary stability rather than the drilling method(p <0.05). 2. If there was cortical bone, it is more advantagous to get stronger primary stability. 3. If cancellous bone is more dense or if cortical bone exists, there is no statistical significance between drilling and osteotome method(p <0.05).

임플란트 일차 안정성에 있어서 고정체 지름에 따른 osteotome 술식의 효과 (The effect of osteotome technique on primary implant stability according to implant fixture diameter)

  • 김수현;이재관;박찬진
    • Journal of Periodontal and Implant Science
    • /
    • 제35권3호
    • /
    • pp.789-798
    • /
    • 2005
  • Primary stability is a fundamental criteria of implant success. There has been various trials to increase initial stability and bone to implant contact. The objective of osteotome technique is to preserve all the existing bone by minimizing or even eliminating the drilling sequence of the surgical protocol. The bone layer adjacent to the osteotomy site is progressively compacted with various bone condensers(osteotomes) this will result in a denser bone to implant contact. This improved bone density helps to optimize primary implant stability in low density bone. The use of wide implant is one of methods to increse primary stability. They can be used in special situations in which they can increase the surface area available for implant anchorage and improve their primary stability The aim of this study was to evaluate the influence of the osteotome technique and implant width on primary stability. Osteotome technique was compared with conventional drilling method by resonance frequency measurments according to the implant fixtures diameter. The results were as follows: 1. The average of ISQ value was sightly higher in osteotome technique, but there was not statistically significant in regular and narrow implant(p <0.05). 2. Either osteotome technique or conventional technique. ISQ value was significantly higer as increasing of implant diameter(p <0.05). 3. ISQ value of drilling technique was higer than those of osteotome technique in wide implant. It was assumed to be caused by difference in final preparation diameter.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • 제52권5호
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Effects of a simplified drilling protocol at 50 rpm on heat generation under water-free conditions: an in vitro study

  • Hyeon-Ji Jang;Jin-Un Yoon;Ji-Young Joo;Ju-Youn Lee;Hyun-Joo Kim
    • Journal of Periodontal and Implant Science
    • /
    • 제53권1호
    • /
    • pp.85-95
    • /
    • 2023
  • Purpose: In recent years, guided implant surgery has been widely used for the convenience of patients and surgeons. Further streamlining the surgical procedure would make implant surgery more convenient. Low-speed water-free conditions are often used in guided implant surgery. Therefore, in this study, we attempted to confirm once again whether drilling was safe at a low speed without water. The main purpose of this study was to evaluate whether a simplified drilling protocol that omits some intermediate steps in the drilling process was safe from the viewpoint of heat generation. Methods: D1 density artificial bone blocks were drilled under 50 rpm, 10 N·cm water-free conditions, and the surface temperature was measured using a digital infrared camera. First, drilling was performed with the sequential drilling method, which is the most widely used technique. Second, for each drill diameter, the temperature change was measured while performing simplified drilling with omission of the previous 1, 2, or 3 steps. Results: In sequential drilling, the heat generated during drilling at all diameters was less than the critical temperature of osteonecrosis (47℃) except for the ⌀2 drill. Statistical significance was observed in all groups when comparing sequential and simplified drilling in the ⌀3.2, ⌀3.8, and ⌀4.3 drills (P<0.001). However, in the simplified drilling procedures, the temperature was below the osteonecrosis threshold temperature (47℃) except for the ⌀4.3 drill with the omission of the previous 3 steps (⌀3.0, ⌀3.2, and ⌀3.8). Conclusions: In general, drilling under low-speed, water-free conditions has shown stable results in terms of heat generation. Simplified drilling showed statistically significantly greater heat generation than sequential drilling. However, most of the diameters and omitted steps seem to be clinically acceptable, so it will be useful if an appropriate selection is made according to the patient's clinical condition.

유리섬유/폴리프로필렌 복합재료 (Twintex)를 이용한 고정판 성형조건에 관한 연구 (A study on the forming condition of a bone plate made of a glass/polypropylene composite (Twintex))

  • 박석원;유성환;이재응;장승환
    • Composites Research
    • /
    • 제23권6호
    • /
    • pp.55-60
    • /
    • 2010
  • 본 연구에서는 열가소성 복합재료인 유리섬유/폴리프로필렌 복합재료를 이용한 복합재료 고정판의 적절한 성형조건을 찾기 위해 다양한 성형조건으로 제작된 시편의 인장실험과 굽힘실험을 수행하여 성형조건에 따른 기계적 거동을 비교하였다. 실험 결과 성형온도와 압력이 각각 $230^{\circ}C$, 3MPa일 때 가장 우수한 기계적 특성을 가짐을 확인하였다. 성형실험을 통해 결정된 성형조건을 이용한 복합재료 고정판의 성형방법으로는 고정판의 스크류 구멍을 한번에 성형하는 정형성형방법과 스크류 구멍을 후가공하는 방법을 사용하였으며, 성형실험과 굽힘실험 결과 스크류 구멍을 후가공 하는 경우 우수한 굽힘특성을 가지는 것을 확인하였다. 본 논문에서는 복합재료 고정판의 적절한 성형을 위해 유리섬유/폴리프로필렌 복합재료의 기초 성형정보와 그에 따른 고정판 성형에 대한 연구를 수행하였으며, 이 결과는 해당재료를 이용한 구조물 성형에 중요한 정보를 제공할 것으로 기대된다.

임프란트 식립시 초기 안정성이 골유착에 미치는 영향 (THE INFLUENCE OF THE INITIAL STABILITY AFTER DENTAL IMPLANT INSTALLATION ON THE OSSEOINTEGRATION)

  • 이영훈;김여갑;최병준
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권6호
    • /
    • pp.518-528
    • /
    • 2008
  • Purpose: The long-term experience of using osseointegrated implants for prosthetic rehabilitation of the edentulous patients shows that high success rates can be predictably achieved. Primary implant stability has been identified to be a prerequisite to achieve osseointegration. In this study, we set up the amount of removed bone so that it differed on implant installation site for each group. The influence of each initial stability on secondary stability and osseointegration was compared with time lapse using resonance frequency analysis and histomorphometric analysis. Materials and methods: A total 27 US $II^{(R)}$ (Osstem, Korea) implants were placed in the mandibular edentulous area of 3 beagle dogs. The implant site was prepared by the conventional technique with drills, and three experimental groups were divided into under-drilling group, normal-drilling group and over-drilling group. The Implant Stability Quotient (ISQ) was measured at intervals of immediately, 4, 8, 12 weeks after placement using $Osstell^{(R)}$ mentor RFA. After the animals were sacrificed, histomorphometric evaluation was executed for measuring BIC and BD. Results: 1) The under-drilled group showed most high ISQ value for whole experiment period. 2) Bone-to-implant-contact(BIC) showed the tendency to be increased gradually as the experiment period passed except the 8 weeks of the normal group. 3) The under-drilled group showed most high bone density(BD) level for whole experiment period, and it was expressed the aspect to be increased gradually according to an experiment period passage in the average of all group. 4) Resonance frequency analysis and histomorphometric analysis are presumed by generally proportional. Conclusions: As this research result, it seems that there are some correlation between resonance frequency analysis and histomorphometric analysis. As are accomplished osseointegration stably so that more superior at the region which the overpressure comes to add, it will be applicable method in clinical field.

백서 대퇴골 결손부에 매식된 밀랍지혈제의 조직반응에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECTS OF BONE WAX ON THE MOUSE FEMORAL BONE DEFECTS)

  • 김장연;한경수;엄인웅;정호용
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제14권3호
    • /
    • pp.228-236
    • /
    • 1992
  • This study was to designed to evaluate the reactions of mouse femoral bone to bone wax. In sixteen mice with a strain of I. C. R. mouse weighed approximately 300 to 850g 2.0~2.0mm sized bone defects were created by drilling. Half of mice were inserted by bone wax and the remainder serving as control without bone wax application. The mice were sacrificed 1, 2, 6, 8 weeks after operation and block specimens were prepared for light microscopy examination. The results obtained were as follows. 1. Histologic features of tissue reaction to bone wax were the presence of inflammatory cell infiltration and multinucleated giant cell. 2. Bone ear healing from the created margin were markedly impaired by the application of bone wax 3. New bone formation was markedly decreased in bone wax application.

  • PDF