• Title/Summary/Keyword: Bone density measurement

Search Result 131, Processing Time 0.028 seconds

Comparative of Bone Mineral Density according to the Body Mass Index and Eating Habits of Female U niversity Students (여대생의 체질량지수와 식습관에 따른 골밀도 비교)

  • Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.581-587
    • /
    • 2017
  • This study was based on the data of total mineral content of about 99% at the age of 16-26 years, we aimed at female university students who are important for bone formation in their early 20s. The purpose of this study was to investigate factors of eating habits affecting their bone density and to provide data to prevent osteoporosis which might occur in the future. It was conducted on 100 female university students in their 20s, the bone mineral density according to BMI was measured by DEAX, and the analysis of 10 eating habits items and the results of BMD measurement on their own results in Excel 2010. As a result, the height was $161.08{\pm}4.70cm$, the weight was $52.43{\pm}6.43kg$, and the BMI was $20.22{\pm}2.48$, which correlated with BMD (p<0.05). According to the BMI classification, 20 had low weight and 80 had normal weight, and BMD was $0.20{\pm}0.41$ at normal weight. In the same sex, the mean T-score of the young adult group was $-0.04{\pm}0.99$ compared with the BMD of the young adult group, and the mean Z-score of the same age group was $0.02{\pm}0.93$ (p<0.001). Eating habits affecting bone mineral density were significantly affected by 3 meals per day, 1-3 cups of coffee per day and p<0.05 for Low salt formula intake. 6-9 dairy product intake was also p<0.05 but not significant. Therefore, it is considered that when 20s female students become middle-aged woman, they should have proper eating habits so that osteogenesis can be improved at young age in order to prevent bone disease.

Digital X-Ray Image Processing Method for Bone Mineral Density Measurement (골밀도 측정을 위한 Digital X-Ray 영상 처리 방법)

  • Han Ki-Seo;Yeom Jin-Su;Ryu Kwang-Ryol;Hur Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.239-242
    • /
    • 2006
  • 골다공증은 해면골의 골소주 두께 감소 및 파단에 기인한 전체적인 골질이 저하되는 질병이다. 골다공증을 예방과 조기진단을 하기 위해서는 골밀도를 측정하여야 한다. 보다 나은 이미지를 얻기 위해 Digital X-Ray로 골밀도를 측정하여 영상 처리하기 위한 방법을 제시한다. 먼저 디지털 센서에서 증감지와 렌즈간 거리가 가까워서 증감지의 중심과 주변부의 광 경로차이가 발생하므로 왜곡이 발생하는데 이를 균일화하여야 한다. 그리고 X-Ray장비의 조건에 따라 영상에 많은 차이를 보이므로 영상의 밝기를 보정하는 과정이 필수적이다.

  • PDF

A Study on the Result of Test Site on BMD (골다공증 검사 시 검사부위에 따른 결과에 대한 고찰)

  • Hong, Dong-Hee;Han, Sang-Hyun;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • The measurement of Korea people's Radial-terminal region were frequently measure of the left hand of Radial-terminal region due to the most Korean's are right-handed and it occasionally showed incorrect results. Therefore, in this study, we accessed a correlation with error of measurement and reduced the measurement error invalid. We reviewed 50 adults patients, from March 2012 for a certain period of time, visited the orthopedic center for the neutral position of forearm of plain radiography and measured the left side of the distal radial-terminal region containing the terminal region of the right distal radius. Then we have compared and analysed both T-score. As a result, the lower value of left wrist were 45 out of 75 which is approximately 60% of left wrist group while the lower value of right wrist were 30 out of 75 which is approximately 40% of right wrist group.

The efficacy evaluation of $PostPlant^{TM}$ Calcium in dental implant placement (임플란트 식립 환자의 $PostPlant^{TM}$ Calcium 투여 효과에 대한 임상연구)

  • Choi, Yu-Sung;Kim, Eun-Kyung;Kim, Se-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the changes in bone density and reduction of time consumed for osteogenesis by $PostPlant^{TM}$ Calcium and to find out efficacy of $PostPlant^{TM}$ Calcium by comparing the group prescribed with $PostPlant^{TM}$ Calcium with the group without $PostPlant^{TM}$ Calcium prescription. Material and methods: The experimental group of 18 patients with 25 dental implant placement and the control group of 7 patients with 9 dental implant placement were randomly selected from the patients who visited prosthetic department of Dankook University Dental Hospital since July, 2006 (IRB Number ; 20060710). The experimental group was instructed to take $PostPlant^{TM}$ Calcium for 6 months after the implant surgery while the control group was instructed not to. Both experimental and control group were assigned for measurement using $Osstell^{TM}$ Mentor and $Periotest^{(R)}$ and radiographic examination was performed using specifically manufactured Aluminum Step Wedge. The results were compared and analyzed. Results: 1. According to the $Osstell^{TM}$ Mentor measurement, both the experimental and control group showed increase in values as time elapses and the experimental group showed significantly higher rate of increase (P < .05). 2. According to the $Periotest^{(R)}$ measurement, both the experimental and control group showed decrease in values as time elapses. In addition, greater decrease can be seen in the experimental group but no statistical significance was found. 3. By examining the radiographic images, both the experimental and control group showed tendency of increase in bone density. In addition, greater increase can be seen in the experimental group but no statistical significance was found. Conclusion: Clinically, taking $PostPlant^{TM}$ Calcium medicine for a long period of time after implant placement is expected for a better prognosis.

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

Evaluation of Sodium Intake and Relationship between Sodium Intake and the Bone Mineral Density of Female University Students (중부 지역 여대생에서 음식섭취빈도조사지를 이용한 나트륨 섭취량 평가 및 나트륨 섭취와 골밀도와의 관련성 조사)

  • Bae, Yun-Jung;Yeon, Jee-Young
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.5
    • /
    • pp.625-636
    • /
    • 2011
  • The purpose of this study was to evaluate the relationship between bone health and sodium intake in female university students using a dish frequency questionnaire (DFQ 125), anthropometric checkups, food records for 3 days, and ultrasound measurement of calcaneus bone mineral density. Subjects were divided into two groups: normal (n=196) and osteopenia (n=52). There were no significant differences in age or height between the two groups. The average weight, body mass index, and body fat in the normal group were significantly higher than in the osteopenia group. The sodium intake of DFQ was positively correlated with the sodium intake of 3 days of dietary records (p=0.0003). There were no significant differences in the sodium intake between the two groups from DFQ. The dishes were ranked by sodium intake: kimchies were 17.68%, noodles and mandu were 16.36%, stews were 13.69%, main dishes such as meat, egg, and beans were 11.47%, and fish and shellfish were 11.07%. The frequency of eating noodles and mandu (p=0.0116), stews (p=0.0008), kimchies (p=0.0482), fish and shellfish (p=0.0362), vegetables (p=0.0064) and seasoning (p=0.0347) were negatively associated with bone mineral density. Bone health was not significantly different with increasing quartiles of sodium intake. As excessive sodium intakes may indirectly affect bone mineral density, these results suggest that to prevent osteoporosis, university students needed to be more educated about diets containing less sodium through nutrition education programs.

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

A Study on the Effect of Erycibae Caulis and Corydalis Tuber Pharmacopuncture on a Mouse Model with Collagen Induced Rheumatoid Arthritis (정공등현호색(丁公藤玄胡索) 약침(藥鍼)이 류마티스 관절염 생쥐 모델에 미치는 영향)

  • Kim, Hyun Ji;Jeon, Ju Hyun;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.33 no.2
    • /
    • pp.21-34
    • /
    • 2016
  • Objectives : The aim of the present study is to examine the effect and mechanism of Erycibae Caulis and Corydalis Tuber Pharmacopuncture (ECP) on a mouse model with collagen induced rheumatoid arthritis (CIA). Methods : We evaluated the Aspartate aminotransferase (AST), Alanine aminotransferase (ALT), Creatinine, and the Blood urea nitrogen (BUN) of serum to examine the safety of this study. In vivo, we compared the results of the non-treated group, the normal saline pharmacopuncture treated control group, the indomethacin treated group and the ECP group. We evaluated rheumatoid arthritis manifestation and the Rheumatoid Arthritis Index (AI). Also, immune cells in blood affected by ECP were evaluated by calculating the level of white blood cells (WBC), neutrophil, lympocytes and monocytes. Next, the level of Immunoglobulin M (IgM), Immunoglobulin G (IgG), Interleukin (IL)-$1{\beta}$, IL-6, IL-17, Tumor Necrosis Factor (TNF)-${\alpha}$ and Granulocyte-macrophage Stimulating Factor (GM-CSF)in serum were measured. We examined the imaging of cartilage degeneration using micro CT-arthrography of the hind paw. Additionally, we examined the effects of reducing bone volume (BV) ratio and bone surface/bone volume (BS/BV) ratio with 3D Micro-CT. Finally, we did a histopathologic examination analysis. Results : The absence of liver and kidney toxicity was evident. In vivo, edema of the joints of the ECP group decreased greatly in macroscopic observation. AI measurement of the ECP group also decreased significantly compared to the control group. The level of WBC, neutrophil, lympocytes, and monocytes in the blood decreased but there was no statistical significance of this data. IgM of the ECP group decreased significantly compared to the control group. IL-$1{\beta}$, IL-6, TNF-${\alpha}$, and GM-CSF production of the ECP group decreased significantly compared to the control group. As a result of examining joint condition with 3D micro CT, deformation and destruction of the joint was shown to have decreased. Bone density of ECP group increased at a statistically significant level compared to the control group. Degree of joint inflammation of ECP group decreased significantly compared to the control group. After H&E and M-T staining, infiltration of immune cells, subsidence of the cartilage, damage to the synovial cells and joint erosion decreased. Conclusion : This study showed that ECP hindered the process of rheumatoid arthritis and protected joints and cartilage.