• Title/Summary/Keyword: Bone density change

Search Result 187, Processing Time 0.029 seconds

Observation of the change of the dental implant stability and bone density evaluation methods (골밀도 평가방법과 임플란트 안정성 변화의 관찰)

  • Ko, Sok-Min;Park, Sung-Jae;Kim, In-Soo;Song, Seung-Il;Lee, In-Kyung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.185-192
    • /
    • 2009
  • Purpose: The aim of this study was to examine the correlation of the subjective and the objective evaluation of edentulous ridge bone quality, and to evaluate the change of the dental implant stability in each bone density group for early healing period after implant installation. Methods: Sixty-seven implants(Osstem implant$^{(R)}$, Seoul, Korea) were included in this study. We evaluated the bone density by 2 methods. The one was the subjective method which was determined by practitioner s tactile sense, the other was the objective bone type was based on Hounsfield units. The implant stability in each bone type group was assessed by resonance frequency analyzer(Osstell mentor$^{(R)}$). Data were analyzed for the change of the implant stability, and they were compared to verify the difference of groups at the time of installation, 2, 6, 10, 14 weeks postoperatively. Spearman's correlation was used to demonstrate the correlation between the subjective and the objective evaluation of the bone density, and analysis of variance(ANOVA) was used to analyze the differences of implant stability at each time point. Results: There was no close relation between the subjective and the objective evaluation of the bone density(r=0.57). In the subjective groups, there was statistically significant difference between the type 1 and 3 at 10 weeks and between the type 2 and 3 at 14 weeks. In the objective groups, there was no statistically significant difference between the D 1, 2, 3, 4, and 5 group with regard to RFA from baseline to 14 weeks(P>0.1). Conclusions: The implant stability increased over time during the study, and it was improved with bone density proportionally after 2weeks postoperatively. It is recommended that the decision of bone density is base on Hounsfield unit for implant loading time.

Analysis change in Bone Mineral Density before and after Kidney Transplant in Renal Failure Patient (신부전환자의 신장이식 전후 골밀도변화 분석)

  • Park, Hyong-Hu;Ok, Chi-Sang;Park, Young-In;Lee, Jin-Soo;Kim, Chang-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.250-256
    • /
    • 2012
  • Disease, such as osteopenia, osteoporosis, etc caused by reduced bone density are common to women after menopause and as the social medical cost increases due to osteoporosis fractures the medical interest in bone density reduction has increased. The bone density reduction is observed even for renal failure patients, due to their decreased ability to synthesize vitamin D which leads to bone fibrosis because of deficiency in calcium absorption. Thus renal failure patients not only suffer from kidney dysfunction, but also are exposed to complications, such as osteoporosis, due to reduced bone density. This research observed the change in bone density of patients receiving renal failure treatment and analyzed the change in bone density before and after kidney transplantations. Subjects were 214 renal failure patients at the department of nephrology Busan B General Hospital. The change in bone density was studied for subjects with and without kidney transplantation according to their age and sex. The research showed improvement or maintenance of bone density for subjects that received kidney transplantation, but showed a tendency of consistent decrease in bone density for subjects without kidney transplantation. Kidney transplantation can be considered as the best cure for renal failure patients, and this researched confirmed that bone density can be improved through kidney transplantation. Thus, this study can also be used as data for preventing complications due to renal failures.

Calculation of the Least Significant Change Value of Bone Densitometry Using a Dual-Energy X-ray Absorptiometry System

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.95-98
    • /
    • 2023
  • Purpose: The precision error of a bone density meter reflects the equipment and reproducibility of results by an examiner. Precision error values can be expressed as coefficient of variation (CV), CV%, and root mean square-SD (RMS-SD). The International Society for Clinical Densitometry (ISCD) currently recommends using RMS-SD as the precision error value. When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding the LSC value reflects a significant difference in measured bone density. Therefore, the LSC value of a bone density equipment is an essential factor for accurately determining a patient's bone density. Accordingly, we aimed to calculate the LSC value of a bone density meter (Lunar iDXA, GE) and compare it with the value recommended by the ISCD. We also assessed whether the value measured by the iDXA equipment was below the LSC value recommended by ISCD. Material and Methods: The bone densities of the lumbar spine and thighs of 30 participants were measured twice, and the LSC values were calculated using the precision calculation tool provided by the ISCD (http://www.iscd.org). To check the reproducibility of the measurement, patients were asked to completely dismount from the equipment after the first measurement; the patient was then repositioned before proceeding with the second measurement. Results: The LSC values derived using the CV% values recommended by the ISCD were 5.3% for the lumbar spine and 5.0% for the thigh. The LSC values measured using our bone density equipment were 2.47% for the lumbar spine and 1.61% for the thigh. The LSC value using RMS-SD was 0.031 g/cm2 for the lumbar spine and 0.017 g/cm2 for the thigh. Conclusion: that the findings confirm that the CV% value measured using our bone density meter and the LSC value using RMS-SD were maintained very stably. This can be helpful for obtaining accurate measurements during bone density follow-up examinations.

Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

  • Yunus, Barunawaty
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • Purpose : This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods : This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results : The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion : CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

A STUDY ON THE BONE MINERAL DENSITY OF ILIAC AND TIBIAL BONE USING DUAL ENERGY X-RAY ABSORPTIOMETRY (이중에너지 방사선 흡수계측법을 이용한 성인 남녀의 장골 및 경골의 골밀도에 관한 연구)

  • Cho, Yong-Seok;Kim, Kyoung-Won;Lee, Keong-Ho;Park, Hyun-Jin;Seo, Sang-Su;Oh, Sang-Youp
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.265-273
    • /
    • 2000
  • Purpose : The aim of this study was to evaluate the bone mineral density of iliac and tibial bone which are frequently selected as autogenic bone graft donor sites, and to evaluate the efficiency of this method as a guideline for the selection of bone graft donor site. Materials and Methods : In this study 61 male and 70 female volunteers at Chungbuk National University Hospital were involved between Jan. 1998 to Sept. 1999. We measured bone mineral density of the iliac and the tibial bone using dual energy X-ray absorptiometry. We evaluated the data using the SAS system for Windows and bone mineral density of the lumbar was used for control. Results : Age showed the highest correlation in correlation matrix between physical and bone variables. Height and weight showed lower correlation of linear increment. In man, the change of bone density according to age demonstrated linear decrease irrespective of the lumbar, ilium, and tibia. In woman, the change of bone density according to age showed cubic form, which increased in the third and forth decade. So it had a peak bone mass on about 35 year-old, thereafter, the change of bone density slowly decreased until 50 year-old, but it rapidly decreased after 50 year-old and it slowly decreased again after 65 year-old. Both in all subjects and subject with osteoporosis, the change of bone mineral density according to age showed statistically significant decrease in lumbar and tibia, but ilium was irrespective. Conclusion : In patients of aged or with osteoporosis, ilium demonstrated less tendency of decrease in bone mineral density than tibia. So this preliminary study suggested that ilium seemed better donor site for autogenic bone graft than tibia.

  • PDF

Analysis of bone-remodeling by the influence of external fixator with FEM (FEM을 이용한 외부고정구 영향에 의한 골-재형성에 대한 해석)

  • 김영은;이원식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.436-444
    • /
    • 1991
  • A computational method has been developed to analyze the bone-remodeling induced by external fixator. The method was based on the Finite Element Method (FEM) in combination with numerical formulation of adaptive bone-remodeling theories. As a feed-back control variable, compressive strain and effective stress were used to determine the surface remodeling and internal (density) remodeling respectively. Surface remodeling and internal remodeling were combined at each time step to predict the rel situation. A noticeable shape and density change were detected at the region between two pins and density change was decreased with time increment. At final time step, the shape and density distribution were converged closely to its original intact bone model. Similar change was detected in stress distribution. The altered stress distribution due to the pin and external fixator converged to the intact stress distribution with time.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

A STUDY OF MARGINAL BONE RESORPTION AROUND IMPLANTS AFTER IMMEDIATE LOADING (Immediate loading하에서 치근형 임프란트 주위 변연골 흡수에 대한 연구)

  • Kim Sung-Hyen;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.376-390
    • /
    • 2001
  • Alveolar bone changes after immediate loading on implants up to one year were observed by means of standard intraoral X-ray measurement which were taken at 3 month intervals. At the same time, bone density changes were observed according to digital subtraction method which is a becoming a more and more promising diagnostic tool for implants. Following results were obtained ; 1. There was no significant difference in the amount of alveolar bone loss implant type, sex and implant diameter, but there was difference according to case selection. In fully bone anchored prostheses cases, bone loss was $1.16{\pm}0.15m$ whereas, in partial edentulous cases, it was $1.84{\pm}0.08mm$. 2. Alveolar bone loss after immediate loading showed a higher degree of bone loss than after submerged loading in the initial three months. But there were no significant difference at the 12th month. 3. According to the one year bone density change observation at the alveolar bone surrounding the implant, significant change was observed vertically, whereas no significant change could observed horizontally. According to the above mentioned results, we can conclude that immediate loading of implants results in a higher degree of alveolar bone loss in one year than submerged loading. But since alveolar bone loss rate decreases to a reasonable rate after the initial 3 months of rapid bone loss, immediate loading of implants seems to be an acceptable treatment modality for patients with good bone conditions. Fully bone anchored cases showed an favorable outcome, but partial edentulous cases showed more bony resorption. So this cases considered in case selections. Bone density changes observation in the study was performed for only one year therefore a more longitudinal observation may be studied.

  • PDF

A study on growth and development of children by ultrasonic image of calcaneus bone (종골의 초음파영상을 통한 소아성장에 관한 연구)

  • Chang, Gyu-Tae;Kim, Jang-Hyun;Seo, Young-Min
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.1-13
    • /
    • 2003
  • Objectives: The purpose of this study was to suggest a scientific method for measurement of children's growth development. Ultrasonic image of calcaneus bone has some advantages that it is harmless to human body and apply a new imaging analysis algorithm. it can be used for the diagnosis of growth analyzed the opening degree of growth plate and bone density. Methods: This clinical study have been carried out with the 57 case(male 24, female 33) of the children aged 5 to 14 years old who visited in Department of Pediatrics, Dongguk university Bundang Oriental Hospital. Bone maturity is measured by the opening degree of growth plate and bone density in ultrasonic image of calcaneus bone This study were designed to investigate the relationship of the development of children and the calcaneus bone maturity. Result: The opening degree of growth plate was no change in aged 5-10 years for male and 5-9 years for female but decreased significantly from aged 11 years for male and 10 years for female. the bone density was no change in aged 5-12 years for male and 5-11 years for female but increased significantly from aged 13 years for male and 12 years for female. it was confirmed that bone maturity in female is more rapid than in male. The opening degree of growth plate of claclneus bone was correlated with age, height, weight. The bone density was correlated with age, height, weight, BMI in this suudy(P<0.001) Conclusion: The opening degree of growth plate and bone density of calcaneus bone are sufficient diagnostic worth as an index to predict adolescent growth.

  • PDF

The Effects of the Thera Band Exercise Program on Bone Mineral Density and Health Promotion Behaviors in Elderly Women (세라밴드 운동 프로그램이 여성노인의 골밀도와 건강증진행위에 미치는 효과)

  • Kim, Joo Hyun;Hyun, Hye Jin;Ahn, Mi Hyang;Choi, Eun Young;Ko, Ga Yeon;Park, Bock Soon
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.3
    • /
    • pp.147-153
    • /
    • 2013
  • Purpose: This study was conducted in order to closely examine the effects on bone mineral density and health promotion behaviors following the intervention of a 20-week Thera band exercise program targeting elderly women. Methods: This study is a pseudo-experimental research with a pre-and-post design in a single group that examined the effects after the intervention of Thera Band Exercise for 20 weeks targeting 31 elderly women over 60 years of age who visit a Senior Welfare Center located in K city. It analyzed subjects' general characteristics using error and percentage, health promotion behavior, and a bone density aspect using the mean and standard deviation, as well as a change in the health promotion behavior and bone density, before and after exercise with Paired t-test by using the SPSS 18.0 program. Results: The effect of the Thera band exercise program on bone mineral density was reduced (t=8.140, p<.001) gradually after 20 weeks of exercise compared to the pre-exercise period. The health promotion behavior before and after exercise showed the significantly increasing outcomes (t=3.26, p=.003). Conclusion: There is a limitation to a direct rise in bone mineral density with the use of Thera band exercise intervention in the elderly. A change in health promotion behavior before and after exercise increased significantly. Thus, it was confirmed that taking exercise leads to a gradual rise in health promotion behavior. Hence, it understood that continuous exercise is useful and brings about a positive change in promoting health maintenance in elderly women.