• Title/Summary/Keyword: Bone cement

Search Result 228, Processing Time 0.026 seconds

Primary stability of implants with peri-implant bone defects of various widths: an in vitro investigation

  • Yim, Hyun-jin;Lim, Hyun-Chang;Hong, Ji-Youn;Shin, Seung-Il;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Yun
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.1
    • /
    • pp.39-46
    • /
    • 2019
  • Purpose: This study aimed to evaluate the effects of i) the extent of peri-implant bone defects and ii) the application of bone cement on implant stability with respect to the measurement direction. Methods: In 10 bovine rib bones, 4 implant osteotomies with peri-implant bone defects of various widths were prepared: i) no defect (D0), ii) a 2-mm-wide defect (D2), iii) a 4-mm-wide defect (D4), and iv) a 8-mm-wide defect (D8). The height of all defects was 10 mm. Implant stability quotient (ISQ) values and Periotest values (PTVs) were measured after implant placement and bone cement application. Results: With increasing defect width, decreased ISQs and increased PTVs were observed. Statistically significant differences were found between groups D0 and D8, D0 and D4, and D2 and D8. Prior to bone cement application, inconsistent PTVs were found in group D8 depending on the measurement direction. Bone cement increased the implant stability. Conclusion: Peri-implant bone deficits measuring around 50% of the implant surface compromised implant stability. Clinically, PTVs should be cautiously interpreted in implants with large peri-implant defects due to inconsistent recordings with respect to the measurement direction.

Bone Cement-Augmented Percutaneous Short Segment Fixation : An Effective Treatment for Kummell's Disease?

  • Park, Seon Joo;Kim, Hyeun Sung;Lee, Seok Ki;Kim, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.54-59
    • /
    • 2015
  • Objective : The aim of this prospective study was to evaluate the efficacy of bone cement-augmented percutaneous short segment fixation for treating Kummell's disease accompanied by severe osteoporosis. Methods : From 2009 to 2013, ten patients with single-level Kummell's disease accompanied by severe osteoporosis were enrolled in this study. After postural reduction for 1-2 days, bone cement-augmented percutaneous short segment fixation was performed at one level above, one level below, and at the collapsed vertebra. Clinical results, radiological parameters, and related complications were assessed preoperatively and at 1 month and 12 months after surgery. Results : Prior to surgery, the mean pain score on the visual analogue scale was $8.5{\pm}1.5$. One month after the procedure, this score improved to $2.2{\pm}2.0$ and the improvement was maintained at 12 months after surgery. The mean preoperative vertebral height loss was $48.2{\pm}10.5%$, and the surgical procedure reduced this loss to $22.5{\pm}12.4%$. In spite of some recurrent height loss, significant improvement was achieved at 12 months after surgery compared to preoperative values. The kyphotic angle improved significantly from $22.4{\pm}4.9^{\circ}$ before the procedure to $10.1{\pm}3.8^{\circ}$ after surgery and the improved angle was maintained at 12 months after surgery despite a slight correction loss. No patient sustained adjacent fractures after bone cement-augmented percutaneous short segment fixation during the follow-up period. Asymptomatic cement leakage into the paravertebral area was observed in one patient, but no major complications were seen. Conclusion : Bone cement-augmented percutaneous short segment fixation can be an effective and safe procedure for Kummell's disease.

Bone Cement Augmentation of Pedicular Screwing in Severe Osteoporotic Spondylolisthetic Patients

  • Kim, Hyeun-Sung;Park, In-Ho;Ryu, Jae-Kwang;Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.6-10
    • /
    • 2007
  • Objective : The purpose of this study was to determine the effect of bone cement augmentation of pedicular screwing in severe osteoporotic spondylolisthetic patients. Methods : Twenty patients with spondylolisthesis (8 : spondylolytic spondylolisthesis 12 : degenerative spondylolisthesis) who had undergone pedicular screwing and interbody fusion for osteoporotic lumbar spine (T-score on bone mineral density<-3.0) from 2002 to 2005 were reviewed. Mean age was 62.3 years with 3 male and 17 female patients. Average follow-up period was 14 months. Average T-score on bone mineral density (BMD) was -3.62. After decompression of neural elements, about 6cc of polymethylmethacrylate (PMMA) was injected into the each vertebral body through transpedicular route. All patients underwent one level interbody fusion and pedicular screw fixation. Clinical outcome was assessed using Oswestry Disability Index (ODI) on the last clinical follow-up. In addition, a modified MacNab's grading criteria was used to objectively assess patient's outcome postoperatively. Radiographic analysis of sagittal contour was assessed preoperatively, immediately postoperatively, and at final follow-up including fusion rate. Results : Eighteen of 20 patients were graded as excellent or good according to the modified MacNab's criteria. An significant improvement of ODI was achieved in both groups. Mean sagittal angle at the preoperative state, postoperative state and at the last follow-up state was $11.0^{\circ},\;20.1^{\circ}$ and $18.3^{\circ}$, respectively, with mean sagittal angle correction gain $7.3^{\circ}$. Firm fusion was achieved in all patients. There were one compression fracture above the fused segment after 6 months follow-up and one case of seroma. But there were no postoperative complications related to bone cement leakage and pedicular screwings such as screw pullout or screw cut-up. Conclusion : Bone cement augmentation of pedicular screwing can be an effective procedure for osteoporotic lumbar spine in spondylolisthetic patients.

Short Segment Fixation for Thoracolumbar Burst Fracture Accompanying Osteopenia : A Comparative Study

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Lee, Sung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • Objective : The purpose of this study was to compare the results of three types of short segment screw fixation for thoracolumbar burst fracture accompanying osteopenia. Methods : The records of 70 patients who underwent short segment screw fixation for a thoracolumbar burst fracture accompanying osteopenia (-2.5< mean T score by bone mineral densitometry <-1.0) from January 2005 to January 2008 were reviewed. Patients were divided into three groups based on whether or not bone fusion and bone cement augmentation procedure 1) Group I (n=26) : short segment fixation with posterolateral bone fusion; 2) Group II (n=23) : bone cement augmented short segment fixation with posterolateral bone fusion; 3) Group III (n=21) : bone cement augmented, short segment percutaneous screw fixation without bone fusion. Clinical outcomes were assessed using a visual analogue scale and modified MacNab's criteria. Radiological findings, including kyphotic angle and vertebral height, and procedure-related complications, such as screw loosening or pull-out, were analyzed. Results : No significant difference in radiographic or clinical outcomes was noted between patients managed using the three different techniques at last follow up. However, Group I showed more correction loss of kyphotic deformities and vertebral height loss at final follow-up, and Group I had higher screw loosening and implant failure rates than Group II or III. Conclusion : Bone cement augmented procedure can be an efficient and safe surgical techniques in terms of achieving better outcomes with minimal complications for thoracolumbar burst fracture accompanying osteopenia.

Bone cement grafting increases implant primary stability in circumferential cortical bone defects

  • Shin, Seung-Yun;Shin, Seung-Il;Kye, Seung-Beom;Chang, Seok-Woo;Hong, Jongrak;Paeng, Jun-Young;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.1
    • /
    • pp.30-35
    • /
    • 2015
  • Purpose: Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortical bone. Methods: Two different circumferential defect depths (2.5 mm and 5 mm) and a control (no defect) were prepared in six bovine rib bones. Fourteen implants of the same type and size ($4mm{\pm}10mm$) were placed in each group. The thickness of the cortical bone was measured for each defect. After the implant stability quotient (ISQ) values were measured three times in four different directions, bone cement was grafted to increase the primary stability of the otherwise unstable implant. After grafting, the ISQ values were measured again. Results: As defect depth increased, the ISQ value decreased. In the controls, the ISQ value was $85.45{\pm}3.36$ ($mean{\pm}standard$ deviation). In circumferential 2.5-mm and 5-mm defect groups, the ISQ values were $69.42{\pm}7.06$ and $57.43{\pm}6.87$, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement, the ISQ values significantly increased to $73.72{\pm}8.00$ and $67.88{\pm}10.09$ in the 2.5-mm and 5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased to more than double that before grafting in the circumferential 5-mm defect group. The ISQ values did not significantly differ when measured in any of the four directions. Conclusions: The use of bone cement remarkably increased the stability of the implant that otherwise had an insufficient level of stability at placement, which was caused by insufficient cortical bone volume.

Bone Cement-Augmented Percutaneous Screw Fixation for Malignant Spinal Metastases : Is It Feasible?

  • Kim, Pius;Kim, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.189-194
    • /
    • 2017
  • Objective : We evaluated the validity of bone cement-augmented percutaneous screw fixation for treating malignant spinal metastases. Methods : Between 2011 and 2015, 14 patients (eight men and six women) who underwent bone cement-augmented percutaneous screw fixation for malignant spinal metastases were enrolled in this study. Their life expectancy was considered to be more than one month and less than one year, based on the revised Tokuhashi scoring system. Clinical findings including the back pain scale score, functional outcome, procedure related complications, and survival were assessed preoperatively, postoperatively, and then six months after the procedure. Results : Twelve of the patients (86%) survived up to six months after the procedure. Three required mini-open decompressive laminectomy for severe epidural compression. Bone cement-augmented percutaneous screw fixation was performed one level above, one level below, and at the pathologic level itself. The mean operation time was 60 minutes (45-180) and blood loss was less than 100 mL. Prior to surgery, the mean pain score on the visual analogue scale was 8.8, while one month after the procedure, it had reduced to 3.0; this improvement was maintained until the six-month assessment in the surviving patients. All patients were able to sit within the first two days after surgery, and no patient experienced neurological deterioration at the one-month follow up after the surgery. No patient experienced screw loosening during the six months of follow-up. Asymptomatic cement leakage into the epidural space was observed in two patients, but no major complications were observed. Conclusion : For selected patients with malignant spinal metastases, bone cement-augmented percutaneous screw fixation can provide significant pain relief and improve quality of life.

An Experimental Study on the Biomechanical Effectiveness of Bone Cement-Augmented Pedicle Screw Fixation with Various Types of Fenestrations

  • Yoon, Sang Hoon;Lee, Sang Hyung;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.779-789
    • /
    • 2022
  • Objective : To analyze the effects of the number and shape of fenestrations on the mechanical strength of pedicle screws and the effects of bone cement augmentation (BCA) on the pull-out strength (POS) of screws used in conventional BCA. Methods : For the control group, a conventional screw was defined as C1, a screw with cannulated end-holes was defined as C2, a C2 screw with six pinholes was defined as C3, and the control group type was set. Among the experimental screws, T1 was designed using symmetrically placed thru-hole type fenestrations with an elliptical shape, while T2 was designed with half-moon (HM)-shaped asymmetrical fenestrations. T3 and T4 were designed with single HM-shaped fenestrations covering three pitches and five pitches, respectively. T5 and T6 were designed with 0.6-mm and 1-mm wider fenestrations than T3. BCA was performed by injecting 3 mL of commercial bone cement in the screw, and mechanical strength and POS tests were performed according to ASTM F1717 and ASTM F543 standards. Synthetic bone (model #1522-505) made of polyurethane foam was used as a model of osteoporotic bone, and radiographic examinations were performed using computed tomography and fluoroscopy. Results : In the fatigue test, at 75% ultimate load, fractures occurred 7781 and 9189 times; at 50%, they occurred 36122 and 82067 times; and at 25%, no fractures occurred. The mean ultimate load for each screw type was 219.1±52.39 N for T1, 234.74±15.9 N for T2, 220.70±59.23 N for T3, 216.45±32.4 N for T4, 181.55±54.78 N for T5, and 216.47±29.25 N for T6. In comparison with C1, T1, T2, T3, T4, and T6 showed significantly different ultimate load values (p<0.05). However, when the values for C2 and the fenestrated screws were evaluated with an unpaired t test, the ultimate load value of C2 significantly differed only from that of T2 (p=0.025). The ultimate load value of C3 differed significantly from those of T1 and T2 (C3 vs. T1 : p=0.048; C3 vs. T2 : p<0.001). Linear correlation analysis revealed a significant correlation between the fenestration area and the volume of bone cement (Pearson's correlation coefficient r=0.288, p=0.036). The bone cement volume and ultimate load significantly correlated with each other in linear correlation analysis (r=0.403, p=0.003). Conclusion : Fenestration yielded a superior ultimate load in comparison with standard BCA using a conventional screw. In T2 screws with asymmetrical two-way fenestrations showed the maximal increase in ultimate load. The fenestrated screws can be expected to show a stable position for the formation of the cement mass.

DCPD Formation and Conversion to HAp in Glass and Glass-ceramic Bone Cement (유리 및 결정화 유리 골 시멘트에서 DCPD의 형성 및 수산화 아파타이트로의 전환)

  • Lim, Hyung-Bong;Kim, Cheol-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.1
    • /
    • pp.26-33
    • /
    • 2011
  • The glass in the system of CaO-$SiO_2-P_2O_5$ and the corresponding glass-ceramics are prepared for bone cements and the behaviors of the hardening and hydroxyapatite formation were studied for the glass and glass-ceramic powders. The glass crystallized into apatite, $\alpha$-wollastonite and $\beta$-wollastonite depending on the glass composition when they were heat-treated at $950^{\circ}C$ for 4 h. A DCPD (dicalcium phosphate dihydrate : $CaHPO_4{\cdot}2H_2O$) was developed when the prepared glass and glass-ceramic powders were mixed with 3M-$H_3PO_4$ solution. The DCPD (Ca/P=1.0) transformed to HAp (Ca/P=1.67) when the bone cement was soaked in simulated body fluid (SBF), and this HAp formation strongly depended on the releasing capacity of $Ca^{2+}$ ions from the glass and glass-ceramic cements. The glass-ceramic bone cement containing $\alpha$-wollastonite crystals showed faster transformation of DCPD to HAp than other glass-ceramics containing $\alpha$- and $\beta$-wollastonite crystals. No hydroxyapatite was observed when the glass-ceramic bone cement containing apatite crystals (36P6C) was soaked in SBF even for 1 month, because no $Ca^{2+}$ ion can be released from the stable apatite crystals.

Delayed Bone Cement Displacement Following Balloon Kyphoplasty

  • Wang, Hee-Sun;Kim, Hyeun-Sung;Ju, Chang-Il;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.4
    • /
    • pp.212-214
    • /
    • 2008
  • We report a rare case of delayed cement displacement after balloon kyphoplasty in patient with K$\ddot{u}$mmell's desease. A 78-year-old woman with K$\ddot{u}$mmell's desease at T12 level received percutaneous balloon kyphoplasty. Two months after surgery, the patient complained of progressive severe back pain. Computed tomographic scans revealed a breakdown of the anterior cortex and anterior displacement of bone cement. Although this complication is very rare, it is likely to occur in treatment of K$\ddot{u}$mmell's disease accompanying anterior cortical defect.