• 제목/요약/키워드: Bone beam

검색결과 335건 처리시간 0.025초

Multiloop Edgewise Arch Wire의 역학적 해석 (MECHANICAL ANALYSIS ON THE MULTILOOP EDGEWISE ARCH WIRE)

  • 전경민;남동석
    • 대한치과교정학회지
    • /
    • 제21권1호
    • /
    • pp.31-51
    • /
    • 1991
  • This study was designed to survey the stress distributions and deflections which were derived from MEAW by the computer-aided three dimensional finite element analysis of teeth and surrounding bone composed of 2839 solid elements and 4621 nodes. MEAW model was also made using the 90 beam elements and the results were expressed by quantitative and visible ways. The findings of this study were as follows. 1 In case of vertical load on the MEAW there were extrusions of anterior teeth and upright effects of the posterior teeth. 2. Without applying the vertical elastics on the MEAW there were intrusions of anterior teeth, but relatively mild force was transmitted to the posterior teeth area. Torque forces were observed on the incisors and molars, and canine was intruded without torque. 3. The magnitudes of forces were different by the amounts of tip back bends of MEAW. 4. The displacements were in inverse proportion to the cross section areas of the wires according to the experiment using the 5 different size arch wires. 5. The difference of deflections between the MEAW and plain arch wire was not so big as the theoretical one but the deflections of MEAW were much more than the plain arch wire in every X, Y, Z direction.

  • PDF

경골 Pilon 골절 후 가동술(mobilization)과 복합운동 적용사례 - 증례 보고 - (The Mobilization and Combined Exercises Application after Fibula Pilon Fracture Operation: Case Study)

  • 안호정;전범수;박지환
    • 대한정형도수물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.51-56
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the effects of mobilization application for the lower extremity after fibula Pilon fracture operation patient. Methods: The subjects was 62 years old male who was injury of Lt. fibula shaft Fx., 3 cuneiform & cuboid Fx., 2.3.4 metatarsal bone Fx., We were compared to result of physical therapy between pre and post exercise for 2weeks. Results: The results of this study were summarized below; The mobilization application of the Lt. lower extremity was significantly differences of the ROM at pre and post therapy after 2 weeks, especially in knee flexion ($40^{\circ}$). The increased of accessary movement was evaluated to increased of the physiologic movement about the joints of the lower extremity. Conclusion: We consider that factors of therapy result were not only fracture types, operation and reduction methods for the fibula Pilon fracture but also the ability of physical therapist's manual techniques.

  • PDF

신경회로망을 이용한 오스테나이트계 스테인리스강 304 용접부의 결함 분류 및 평가에 관한 연구 (A Study on the Defect Classification and Evaluation in Weld Zone of Austenitic Stainless Steel 304 Using Neural Network)

  • 이원;윤인식
    • 한국정밀공학회지
    • /
    • 제15권7호
    • /
    • pp.149-159
    • /
    • 1998
  • The importance of soundness and safety evaluation in weld zone using by the ultrasonic wave has been recently increased rapidly because of the collapses of huge structures and safety accidents. Especially, the ultrasonic method that has been often used for a major non-destructive testing(NDT) technique in many engineering fields plays an important role as a volume test method. Hence, the defecting any defects of weld Bone in austenitic stainless steel type 304 using by ultrasonic wave and neural network is explored in this paper. In order to detect defects, a distance amplitude curve on standard scan sensitivity and preliminary scan sensitivity represented of the relation between ultrasonic probe, instrument, and materials was drawn based on a quantitative standard. Also, a total of 93% of defect types by testing 30 defect patterns after organizing neural network system, which is learned with an accuracy of 99%, based on ultrasonic evaluation is distinguished in order to classify defects such as holes or notches in experimental results. Thus, the proposed ultrasonic wave and neural network is useful for defect detection and Ultrasonic Non-Destructive Evaluation(UNDE) of weld zone in austenitic stainless steel 304.

  • PDF

Studies on seismic performance of the new section steel beam-wall connection joint

  • Weicheng Su;Jian Liu;Changjiang Liu;Chiyu Luo;Weihua Ye;Yaojun Deng
    • Structural Engineering and Mechanics
    • /
    • 제88권5호
    • /
    • pp.501-519
    • /
    • 2023
  • This paper introduces a new hybrid structural connection joint that combines shear walls with section steel beams, fundamentally resolving the construction complexity issue of requiring pre-embedded connectors in the connection between shear walls and steel beams. Initially, a quasi-static loading scheme with load-deformation dual control was employed to conduct low-cycle repeated loading experiments on five new connection joints. Data was acquired using displacement and strain gauges to compare the energy dissipation coefficients of each specimen. The destruction process of the new connection joints was meticulously observed and recorded, delineating it into three stages. Hysteresis curves and skeleton curves of the joint specimens were plotted based on experimental results, summarizing the energy dissipation performance of the joints. It's noteworthy that the addition of shear walls led to an approximate 17% increase in the energy dissipation coefficient. The energy dissipation coefficients of dog-bone-shaped connection joints with shear walls and cover plates reached 2.043 and 2.059, respectively, exhibiting the most comprehensive hysteresis curves. Additionally, the impact of laminated steel plates covering composite concrete floors on the stiffness of semi-rigid joint ends under excessive stretching should not be disregarded. A comparison with finite element analysis results yielded an error of merely 2.2%, offering substantial evidence for the wide-ranging application prospects of this innovative joint in seismic performance.

Central giant-cell granuloma in a patient with neurofibromatosis type 1: 7 years of follow-up

  • Michelle Briner Garrido;Rohan Jagtap;Christopher D. Matesi;Vivian Diaz;John Hardeman;Anita Gohel
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제50권1호
    • /
    • pp.49-55
    • /
    • 2024
  • Neurofibromatosis type 1 (NF1) is an autosomally dominant tumor suppressor syndrome and multisystem disease. Central giant-cell granulomas (CGCGs) can be seen in patients with NF1. A 21-year-old female was diagnosed with two CGCGs, one in the mandible and then one in the maxilla, in a 7-year period. Increased incidence of CGCGs in NF1 patients was thought to be caused by an underlying susceptibility to developing CGCG-like lesions in qualitatively abnormal bone, such as fibrous dysplasia. However, germline and somatic truncating second-hit mutations in the NF1 gene have been detected in NF1 patients with CGCGs, validating that they are NF1-associated lesions. Oral manifestations in patients with NF1 are very common. Knowledge of these manifestations and the genetic link between NF1 and CGCGs will enhance early detection and enable optimal patient care.

Influence of kilovoltage- peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

  • Fontenele, Rocharles Cavalcante;Nascimento, Eduarda Helena Leandro;Imbelloni-Vasconcelos, Ana Catarina;Martins, Luciano Augusto Cano;Pontual, Andrea dos Anjos;Ramos-Perez, Flavia Maria Moraes;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제52권3호
    • /
    • pp.267-273
    • /
    • 2022
  • Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

임플란트 표면의 Ca-P 코팅 방법이 MG63 골모유사세포 반응에 미치는 영향에 대한 in vitro 연구 (The effect of Ca-P coatings of anodized implant surface on response of osteoblast-like cells in vitro)

  • 김일연;정성민;황순정;신상완
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.376-384
    • /
    • 2009
  • 연구목적: 본 연구에서는 양극산화 임플란트 표면에 서로 다른 두 가지 방법, Ion beam-assisted deposition (IBAD)법과 Sol-gel법으로 Ca-P 코팅한 임플란트 시편에 골모세포를 배양하였을 때 세포의 증식, 분화, 형태에 어떠한 영향을 미치는지 조사하고자 한다. 연구재료 및 방법: 지름 10 mm, 두께 2 mm 인 상업용 순수 titanium grade IV 재질의 디스크를 제작하였고, 모든 시편은 acetone, 70% ethanol, 증류수에서 각각 10분씩 세척 후 건조하였다. 모든 표면은 300 V의 constant voltage하에서 양극 산화 (anodized)시킨다. 실험군은 양극산화 임플란트 표면에 각각 IBAD법과 Solgel법으로 Ca-P 코팅하였다. 각 표면의 미세표면 거칠기(Ra)를 측정하였고, SEM을 통해 표면의 형상을 관찰하였다. 골모세포을 배양한 후 각 표면군의 세포 증식, ALP 활성도 및 RT-PCR를 통한 골세포 분화 능력 검증을 하였으며, SEM을 통해 세포의 형상도 확인하였다. 통계분석은 SPSS (version 12.0) 프로그램을 이용하여 Kruskal-Wallis Test로 각 군의 유의성을 검증하였다 ($\alpha$=0.05). 결과: IBAD법으로 Ca-P 코팅한 표면이 Sol-gel법으로 Ca-P 코팅한 표면보다 표면 거칠기 (Ra) 값이 더 크게 나타났다 (P<.05). IBAD법으로 Ca-P 코팅한 표면이 Sol-gel법으로 Ca-P 코팅한 표면 보다 세포 증식이 더 활발하고 골세포 조기 분화 정도를 확인 할 수 있는ALP 활성도 또한 더 높게 나타났다 (P<.05). SEM 관찰 결과IBAD법으로 Ca-P 코팅한 표면에 골모세포들이 친화성을 띄면서 안정적으로 부착되었다. 결론: IBAD법으로 Ca-P 코팅한 표면이 Sol-gel법으로 Ca-P 코팅한 표면보다 더 우수한 세포 반응을 보였다. IBAD법으로 Ca-P 코팅한 표면의 세포들은 증식이 잘 이루어지고 잘 분화된 골모세포 형상을 보이고 ALP 활성도 또한 높아 골 형성을 증가시켜 높은 골-임플란트 접촉을 보일 것이다.

다중표적 뼈 전이암의 하이브리드 세기변조(modified hybrid-VMAT) 방사선치료계획 유용성 평가 (Evaluation of the Modified Hybrid-VMAT for multiple bone metastatic cancer)

  • 정일훈;조윤진;장원석;김세준;하진숙;전미진;정인호;김종대;신동봉;이익재
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.161-167
    • /
    • 2018
  • 목 적 : 동일 선상축(co-axial image)의 다발성 뼈 전이암에 대한 하이브리드 세기변조(modified hybrid-VMAT) 계획의 유용성을 평가하고자 한다. 대상 및 방법 : 동일 선상축의 다발성 뼈 전이암환자 총 5명을 대상으로 치료계획시스템(Ray station, 5.0.2.35, Sweden)을 이용하여 치료계획을 수립하였다. 치료계획용적(planning target volume, PTV) 처방 선량은 30 Gy로 설정하여 총 3가지 치료계획: 용적변조회전치료계획(volumetric modulated arc therapy, VMAT); 배경방사선(background)을 고려하지 않은 하이브리드 용적변조회전치료계획(hybrid VMAT, VMAT(h)); 배경방사선을 고려한 하이브리드 용적변조회전치료계획(modified hybrid VMAT, VMAT(mh))을 비교하였다. 선량용적히스토그램(dose volume histogram, DVH)을 이용하여 PTV의 maximum dose($D_{max}$), mean dose($D_{mean}$), 처방선량지수(conformity index, CI), 선량균질지수(homogeneity Index, HI) 및 손상위험장기(organ at risk, OAR)의 선량을 분석하였다. 또한 monitor unit(MU)와 치료시간(beam on time)을 분석하였다. 결 과 : VMAT, VMAT(h)과 VMAT(mh)의 PTV $D_{max}$는 3188.33 cGy, 3526 cGy, 3285.67 cGy이고, $D_{mean}$은 3081 cGy, 3252 cGy, 3094 cGy이고, CI는 $1.35{\pm}0.19$, $1.43{\pm}0.12$, $1.30{\pm}0.06$이고, HI는 $1.06{\pm}0.01$, $1.14{\pm}0.06$, $1.09{\pm}0.02$로 평가되었다. VMAT(h)과 VMAT(mh)의 OAR은 3 % 증가와 18 % 감소하는 것으로 평가되었다. 추가적으로 평균 MU는 904.90, 911.73, 1202.13 그리고 평균 Beam on time은 $128.67{\pm}10.97$초, $167.33{\pm}7.57$초, $190.33{\pm}4.51$초 소요되었다. 결 론 : 다중표적 치료 시에는 modified Hybrid-VMAT를 적용하면 선량의 겹침이 보정되어 과선량(over dose) 조사되는 것을 방지하는 다중표적을 치료할 수 있다. 그리고 PTV의 선량포함을 만족하면서 주위의 정상장기를 더 효과적으로 보호할 수 있는 치료계획이 가능하다. 또한 modified Hybrid-VMAT의 임상적 효능을 확인하기 위해 많은 수의 환자를 대상으로 한 장기 추적 관찰이 필요하다.

  • PDF

방사선 치료계획 시 불균질 보정에 관한 고찰 (A Study of Heterogeneity Corrections for Radiation Treatment Planning)

  • 이제희;김보겸;박흥득
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.89-96
    • /
    • 2006
  • 목 적: 방사선치료를 목적으로 촬영된 CT영상을 이용하여 조직내 불균질 물질 및 체위고정 기구에 대한 보정이 선량계산 결과에 미치는 영향을 알아보고자 한다. 대상 빛 방법: 체내불균질 물질의 다양한 사례를 알아보기 위하여 본원에서 제작한 물팬텀($250{\times}250{\times}250mm^3$) 내부에 (1) 뼈 (2) 금속 (3) 조영제 (4) 고정기구(Head holder/Vac-lok) 등 CT Number를 변화시킬 수 있는 물질을 삽입하여 CT촬영을 시행 하였다. 각기 다른 형태의 불균질 CT영상을 전산화치료계획장치(RTP)에 입력하여 동일한 조건(SAD=100 cm 조사야=$10{\times}10cm^2$, 깊이=10cm, 1문조사)으로 에너지별(4, 6, 10 MV X-선) 처방선량 100 cGy를 얻기 위한 선량계산(MU)을 시행하여 비교, 분석하였다. 결 과: 물로만 구성된 팬텀을 기준값으로, 불균질 보정계수 차이는 뼈조직 상태인 경우는 $2.7{\sim}5.3%$, 금속물질인 경우 $2.7{\sim}3.8%$, 조영제인 경우 $0.9{\sim}2.3%$, Head holder $0.9{\sim}2.3%$, Head holder와 Pillow인 경우 $3.5{\sim}6.9%$, 그리고 Vac-lok인 경우 $0.9{\sim}1.5%$의 차이로 나타났다. 결 론: 체내의 불균질 보정계수 차이는 임상적으로 그 적용 형태가 다양하고, 일관성을 보이지 않으며, 조사문수가 증가함에 따라 그 차이가 1%미만으로 허용 가능할 것이나, 고정 기구등에 의한 불균질 보정은 충분히 고려하여 선량계산의 부정확도를 최소화 시켜야 할 것으로 사료된다.

  • PDF

Evaluation of the mechanical properties and clinical efficacy of biphasic calcium phosphate-added collagen membrane in ridge preservation

  • Lee, Jung-Tae;Lee, Yoonsub;Lee, Dajung;Choi, Yusang;Park, Jinyoung;Kim, Sungtae
    • Journal of Periodontal and Implant Science
    • /
    • 제50권4호
    • /
    • pp.238-250
    • /
    • 2020
  • Purpose: This study aimed to evaluate the biocompatibility and the mechanical properties of ultraviolet (UV) cross-linked and biphasic calcium phosphate (BCP)-added collagen membranes and to compare the clinical results of ridge preservation to those obtained using chemically cross-linked collagen membranes. Methods: The study comprised an in vitro test and a clinical trial for membrane evaluation. BCP-added collagen membranes with UV cross-linking were prepared. In the in vitro test, scanning electron microscopy, a collagenase assay, and a tensile strength test were performed. The clinical trial involved 14 patients undergoing a ridge preservation procedure. All participants were randomly divided into the test group, which received UV cross-linked membranes (n=7), and the control group, which received chemically cross-linked membranes (n=7). BCP bone substitutes were used for both the test group and the control group. Cone-beam computed tomography (CBCT) scans were performed and alginate impressions were taken 1 week and 3 months after surgery. The casts were scanned via an optical scanner to measure the volumetric changes. The results were analyzed using the nonparametric Mann-Whitney U test. Results: The fastest degradation rate was found in the collagen membranes without the addition of BCP. The highest enzyme resistance and the highest tensile strength were found when the collagen-to-BCP ratio was 1:1. There was no significant difference in dimensional changes in the 3-dimensional modeling or CBCT scans between the test and control groups in the clinical trial (P>0.05). Conclusions: The addition of BCP and UV cross-linking improved the biocompatibility and the mechanical strength of the membranes. Within the limits of the clinical trial, the sites grafted using BCP in combination with UV cross-linked and BCP-added collagen membranes (test group) did not show any statistically significant difference in terms of dimensional change compared with the control group.