• Title/Summary/Keyword: Bone Substitute

Search Result 171, Processing Time 0.021 seconds

Modified toe pulp fillet flap coverage: Better wound healing and satisfactory length preservation

  • Baek, Sang Oon;Suh, Hyo Wan;Lee, Jun Yong
    • Archives of Plastic Surgery
    • /
    • v.45 no.1
    • /
    • pp.62-68
    • /
    • 2018
  • Background Amputation is commonly performed for toe necrosis secondary to peripheral vascular diseases, such as diabetes mellitus. When amputating a necrotic toe, preservation of the bony structure is important for preventing the collapse of adjacent digits into the amputated space. However, in the popular terminal Syme's amputation technique, partial amputation of the distal phalanx could cause increased tension on the wound margin. Herein, we introduce a new way to resect sufficient bony structure while maintaining the normal length, based on a morphological analysis of the toes. Methods Unlike the pulp of the finger in the distal phalanx, the toe has abundant teardrop-shaped pulp tissue. The ratio of the vertical length to the longitudinal length in the distal phalanx was compared between the toes and fingers. Amputation was performed at the proximal interphalangeal joint level. Then, a mobilizable pulp flap was rotated $90^{\circ}$ cephalad to replace the distal soft tissue defect. This modified toe fillet flap was performed in 5 patients. Results The toe pulp was found to have a vertically oriented morphology compared to that of the fingers, enabling length preservation through cephalad rotation. All defects were successfully covered without marginal ischemia. Conclusions While conventional toe fillet flap coverage focuses on the principle of length preservation as the first priority, our modified method takes both wound healing and length into account. The fattiest part of the pulp is advanced to the toe tip, providing a cushioning effect and enough length to substitute for phalangeal bone loss. Our modified method led to satisfactory functional and aesthetic outcomes.

Surface Modification of Biomaterials for Hard Tissue Substitutes to Improve Biocompatibility and Osteoconductivity (생체적합성 및 골전도성 향상을 위한 경조직 대체용 생체재료의 표면개질)

  • Kim, Sung-Wook;Lee, Woo-Kul
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.725-730
    • /
    • 2005
  • In the development of biomaterials as a substitute of hard tissues, the biocompatibility and osteoconductivity of the biomaterial are considered to be one of the most significant considerations. These biological properties of a material can be greatly improved by the modification of the surface properties by the depositing calcium phosphate thin films on the material since calcium phosphate films possess similar chemical compositions to hard tissues. The success of a material as a biomaterial will be determined by the interaction of the surface of the material with the adhesion molecules which induce cellular adhesion and biological responses of the adherent cells. Depending on the adsorption mechanisms and adsorbed conformation of the adhesion molecules on the surface of the biomaterial, cellular responses, such as adhesion, proliferation and differentiation of osteoblast cells, can be promoted or restricted. It has been reported that materials of which surfaces were modified with thin films of calcium phosphate appeared to be more osteoconductive. Rapid formations of bone nodule in addition to higher differentiations of osteoblast have been observed on the calcium phosphate thin films.

Development and validation of a clinical phantom reproducing various lesions for oral and maxillofacial radiology research

  • Han-Gyeol Yeom;Jo-Eun Kim;Kyung-Hoe Huh;Won-Jin Yi;Min-Suk Heo;Sam-Sun Lee
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.345-353
    • /
    • 2023
  • Purpose: The objective of this study was to propose a method for developing a clinical phantom to reproduce various diseases that are clinically prevalent in the field of dentistry. This could facilitate diverse clinical research without unnecessarily exposing patients to radiation. Materials and Methods: This study utilized a single dry skull, which was visually and radiographically examined to evaluate its condition. Existing lesions on the dry skull were preserved, and other relevant lesions were artificially created as necessary. These lesions were then documented using intraoral radiography and cone-beam computed tomography. Once all pre-existing and reproduced lesions were confirmed by the consensus of 2 oral and maxillofacial radiologists, the skull was embedded in a soft tissue substitute. To validate the process, cone-beam computed tomography scans and panoramic radiographs were obtained of the fabricated phantom. All acquired images were subsequently evaluated. Results: Most lesions could be identified on panoramic radiographs, although some sialoliths and cracked teeth were confirmed only through cone-beam computed tomographic images. A small gap was observed between the epoxy resin and the bone structures. However, 2 oral and maxillofacial radiologists agreed that this space did not meaningfully impact the interpretation process. Conclusion: The newly developed phantom has potential for use as a standardized phantom within the dental field. It may be utilized for a variety of imaging studies, not only for optimization purposes, but also for addressing other experimental issues related to both 2- and 3-dimensional diagnostic radiography.

Evaluation of Soybean Meal as a Partial Substitute for Fish Meal in Formulated Diets for Korean Rockfish, Sebastes schlegeli (조피볼락 사료의 어분 대체 단백원으로서 대두박 평가)

  • LEE Sang-Min;JEON Im-Gi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.5
    • /
    • pp.586-594
    • /
    • 1996
  • This study was designed to determine the level of soybean meal (SM) that could be substituted for fish meal in the diet for Korean rockfish (Sebastes schlegeli). A control diet with white fish meal as only protein source was included, SM was substituted at levels of $5\%,\;10\%,\;15\%,\;and\;20\%$ for portions of the fish meal in the diet. Amino acids (met+lys) supplementation and two different SM particle sizes (0.5 mm and 0.25 mm) in the $20\%$ SM diet were compared. In addition, combination of $10\%$ SM, $10\%$ corn gluten meal (CGM) and $10\%$ meat and bone meal (MBM) was substituted for the fish meal in the diet. Duplicate groups of the 30 fish averaging 22.9 g were fed one of 8 isoproteic $(48\%)$and isolipidic $(7.5\%)$ experimental diets to satiation twice a day for 9 weeks. No significant differences were found among fish fed the control, substituting up to $20\%\;SM,\;20\%$ SM containing amino acids, and $10\%\;SM+10\%\;CGM+10\%$ MBM diets in weight gain, feed efficiency, daily feed intake, and protein retention (P>0.05). Feed efficiency, daily feed intake and protein retention in fish fed the diet containing $20\%$ SM with 0.5 mm particle size were not significantly different to those in fish fed the diets containing less than $20\%\;SM\;(P>0.05)$, however, weight gain was significantly lower than that of the control and $5\%\;SM\;diets\;(P<0.05)$. It is concluded that SM ran be used as a partial substitute for fish meal up to $20\%$ in the diet, and that the inclusion of SM with an adequate combination of several protein sources can replace larger amounts of fish meal in the diet.

  • PDF

Generation of a transgenic mouse model to study cranial suture development; Apert syndrome (두개봉합 발육 연구를 위한 형질변환 쥐의 개발 : 어퍼트 신드롬)

  • Lee, Kee-Joon;Ratisoontorn, Chootima;Baik, Hyoung-Seon;Park, Young-Chel;Park, Kwang-Kyun;Nah, Hyun-Duck
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.485-497
    • /
    • 2003
  • The form and function of the craniofacial structure critically depend on genetic information. With recent advances in the molecular technology, genes that are important for normal growth and morphogenesis of the craniofacial skeleton are being rapidly uncovered, shaping up modem craniofacial biology. One of them is fibroblast growth factor receptor 2 (FGFR2). Specific point mutations in the. FGFR2 gene have been linked to Apert syndrome, which is characterized by premature closure of cranial sutures and craniofacial anomalies as well as limb deformities. To study pathogenic mechanisms underlying craniosynostosis phenotype of Apert syndrome, we used a transgenic approach; an FGFR2 minigene construct containing an Apert mutation (a point mutation that substitute proline at the position 253 to arginine; P253R) was introduced into fertilized mouse germ cells by DNA microinjection. The injected cells were then allowed to develop into transgenic mice. We used a bone-specific promoter (a DNA fragment from the type I collagen gene) to confine the expression of mutant FGFR2 gene to the bone tissue, and asked whether expression of mutant FGFR2 in bone is sufficient to cause the craniosynostosis phenotype in mice. Initial characterization of these mice shows prematurely closed cranial sutures with facial deformities expected from Apert patients. We also demonstrate that the transgene produces mutant FGFR2 protein with increased functional activities. Having this useful mouse model, we now can ask questions regarding the role of FGFR2 in normal and abnormal development of cranial bones and sutures.

Human Cord Serum as a Fetal Bovine Serum Substitute for the Culture of Human Amnion-Derived Stem Cells (인간의 양막유래 줄기세포의 체외 배양 시 소태아혈청 대체제로서의 인간제대혈청)

  • Kim, Jin-Young;Park, Se-A;Kang, Hyun-Mi;Kim, Eun-Su;Kim, Hae-Kwon
    • Development and Reproduction
    • /
    • v.11 no.2
    • /
    • pp.85-96
    • /
    • 2007
  • Mesenchymal stem cells (MSC) are promising candidates for cell-based therapies. One major obstacle for their clinical use is the unsafety of fetal bovine serum (FBS), which is a crucial part of all media currently used for the culture of MSC. We investigated the effect of human cord serum (HCS) on the growth response, mRNA and protein expressions of human amnion-derived stem cells (HAM). HAM were isolated from the amnion after a Caesarean section and cultured in DMEM supplemented with 10% FBS, 5% HCS or 10% HCS. During culture, their biological characteristics at earlier and later passages were analyzed using RT-PCR and immunocytochemistry. Regardless of serum sources, HAM showed the prominent expression of Oct-4, Rex-1, SCF, FGF-5, BMP-4, nestin, GATA-4, NCAM and HLA ABC genes. The expression profile was observed even at later passages. Similarly, HAM cultured in either FBS or HCS exhibited the distinct protein expression of collagen I, II, III and XII, fibronectin, $\alpha$-smooth muscle actin, vimentin, CK18, CD54, FSP, TRA-1-60, SSEA-3, -4 and HLA ABC. However, desmin expression was only observed in HAM cultured in medium supplemented with FBS and vWF expression was only found in HAM cultured in medium supplemented with HCS. Overall pattern of gene and protein expression of HAM was typical of known adult stem cells such as bone marrow-derived MSC. In conclusion, HCS could be as effective as FBS for the culture of HAM.

  • PDF

Diagnostic Value of the Cobalt($^{58}Co$) Excretion Test in Iron Deficiency Anemia (철결핍성빈혈(鐵缺乏性貧血)에서 Cobalt($^{58}Co$)배설율검사(排泄率檢査)의 진단적(診斷的) 가치(價値))

  • Sihn, Hyun-Chung;Hong, Kee-Suck;Cho, Kyung-Sam;Song, In-Kyung;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-34
    • /
    • 1976
  • The diagnosis of iron deficiency rests upon the correct evaluation of body iron stores. Morphological interpretation of blood film and the red cell indices are not reliable and often absent in mild iron deficiency. Serum iron levels and iron-binding capacity are more sensitive indices of iron deficiency, but they are often normal in iron depletion and mild iron deficiency anemia. They are also subject to many variables which may introduce substantial errors and influenced by many pathologic and physiologic states. Examination of the bone marrow aspirate for stainable iron has been regarded as one of the most sensitive and reliable diagnostic method for detecting iron deficiency, but this also has limitations. Thus, there is still need for a more practical, but sensitive and reliable substitute as a screening test of iron deficiency. Pollack et al. (1965) observed that the intestinal absorption of cobalt was raised in iron-deficient rats and Valberg et al. (1969) found that cobalt absorption was elevated in patients with iron deficiency. A direct correlation was demonstrated between the amounts of radioiron and radiocobalt absorbed. Unlike iron, excess cobalt was excreted by the kidney, the percentage of radioactivity in the urine being directly related to the percentage absorbed from the gastrointestinal tract. Recently a test based on the urinary excretion of an oral dose of $^{57}Co$ has been proposed as a method for detecting iron deficiency. To assess the diagnostic value of urinary cobalt excretion test cobaltous chloride labelled with $1{\mu}Ci\;of\;^{58}Co$ was given by mouth and the percentage of the test dose excreted in the urine was measured by a gamma counter. The mean 24 hour urinary cobalt excretion in control subjects with normal iron stores was 6.1% ($1.9{\sim}15.2%$). Cobalt excretion was markedly increased in patients with iron deficiency and excreted more than 29% of the dose. In contrast, patients with anemia due to causes other than iron deficiency excreted less than 27%. Hence, 24 hour urinary cobalt excretion of 27% or less in a patient with anemia suggets that the primary cause of the anemia is not iron deficiency. A value greater than 27% in an anemic subject suggests that the anemia is caused by iron deficiency. The cobalt excretion test is a simple, sensitive and accurate method for the assessment of body iron stores. It may be particularly valuable in the epidemiological studies of iron deficiency and repeated evaluations of the body iron stores.

  • PDF

Relationship among Nutritional Intake, Duration of Outdoor Activities, Vitamin D Status and Bone Health in High School Girls

  • Kim, Ji Young;Kim, Oh Yoen;Hyun, Yae Jung;Koo, Sun Mo;Song, Sang Hoon;Jang, Yangsoo;Lee, Jong Ho
    • Nutritional Sciences
    • /
    • v.7 no.4
    • /
    • pp.208-213
    • /
    • 2004
  • In this study, we examined the effects of dietary 1,3-diacylglycerol (DG) compared to conventional triacylglycerol (TG) oil on the postprandial response of total and chylomicron TG, glucose, insulin, and free fatty acid (FFA). This study was conducted using a cross-over design. Ninety subjects participated in the high-fat meal tolerance test where they were randomly assigned to consume two experimental sandwiches containing mayonnaise with TG or DG oil with a seven-day interval. Blood samples were collected before ingestion and at 2, 3, 4 and 6 hr time point after ingestion and analyzed for total and chylomicron TG, glucose, insulin, FFA and phospholipid fatty acid composition. Both TG and DG ingestion had similar effects on postprandial TG response, but a different response from chylomicron TG. Compared with the TG group, TG levels were significantly lower only at 6 hr time point in the DG group. On the other hand, chylomicron TG rose steeply at 2 hr time point and decreased faster in this group. Also, the adjusted value to fasting levels was the same as the unadjusted level. Fasting levels and net differences in insulin were significantly lower at 3 hr time point where chylomicron TG levels were significantly lower in the DG group. But those of glucose and FFA in the TG and DG groups did not differ significantly. Fasting and postprandial levels of fatty acid composition in serum phospholipids in the two groups did not differ significantly. In conclusion, this study indicated that one could reduce the magnitude of postprandial lipemia without influencing glucose metabolism by consumning DG oil as a substitute for TG oil. Based on the correlation of coronary artery disease and postprandial lipemia, dietary DG ingestion might have a beneficial effect in treating such a disease. Further studies are required to clarify the long-tenn effects of dietary DG on blood lipid levels in humans.

The Effect of Temperature and Concentration of Setting Solution on the Rheological Properties of Injectable Calcium Phosphate (경화액의 농도와 온도가 인산칼슘시멘트의 유변학적 성질에 미치는 영향에 관한 연구)

  • Yoo, Hyun-Mi;Chang, Seok-Woo;Park, Dong-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.73-82
    • /
    • 2009
  • Injectable calcium phosphate cement (CPC) has been used as bone substitute successfully due to good biocompatibility and osteoconductivity. One of the important mechanical characteristics of CPC is flowablility, which can be evaluated by measuring rheological parameters. However, there have been few studies that measured rheological properties of CPC. The purpose of this study was to evaluate the effects of temperature and concentrations of 2 kinds of setting solutions, hydroxyprophyl methylcellulose (HPMC) and polyacrylic acid (PAA), on rheological properties of CPC. The CPC used was dicalcium phosphate dihydrate (DCPD). Rheological properties of CPC paste were measured using rheometer. The effect of concentrations of each solution (2% and 1% HPMC and 35% and 17.5% PAA) was evaluated. The effect of temperature ($25^{\circ}C$ and $37^{\circ}C$) on the rheological properties of CPC was also investigated. The statistical analysis was carried out with Mann-whitney test with Bonferronis collection. CPC with both setting solutions showed shear thinning behavior. Higher concentrations of setting solution (2% HPMC and 35% PAA) produced significantly higher viscosity than lower concentrations of setting solution (1% HPMC and 17.5% PAA). CPC with HPMC showed significantly higher viscosity at $37^{\circ}C$ that at $25^{\circ}C$. CPC with PAA showed lower viscosity at $37^{\circ}C$ than at $25^{\circ}C$, although the difference was not statistically significant. The results showed that CPC with HPMC or PAA solutions are pseudoplastic and the concentrations of setting solutions and temperature may have an effect on the rheological properties of CPC paste. These results showed that the flowability of injectable CPC could be improved by use of increasing frequency of oscillation. In clinical practice, the use of ultrasonic vibration would be helpful in application of injectable CPC. CPC with HPMC could be more easily applicated at $25^{\circ}C$ than $37^{\circ}C$. The use of lower concentrations of HPMC and PAA solution would be beneficial in terms of flowability.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF