• Title/Summary/Keyword: Bone Structure

Search Result 541, Processing Time 0.03 seconds

Cell response to a newly developed Ti-10Ta-10Nb alloy and its sputtered nanoscale coating

  • Kim, Young-Min;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.56-61
    • /
    • 2009
  • STATEMENT OF PROBLEM. The success of titanium implants is due to osseointegration or the direct contact of the implant surface and bone without a fibrous connective tissue interface. PURPOSE. The purpose of this study was to evaluate the osteoblast precursor response to titanium-10 tantalum-10 niobium(Ti-Ta-Nb) alloy and its sputtered coating. MATERIAL AND METHODS. Ti-Ta-Nb coatings were sputtered onto the Ti-Ta-Nb disks. Ti6-Al-4V alloy disks were used as controls. An osteoblast precursor cell line, were used to evaluate the cell responses to the 3 groups. Cell attachment was measured using coulter counter and the cell morphology during attachment period was observed using fluorescent microscopy. Cell culture was performed at 4, 8, 12 and 16 days. RESULTS. The sputtered Ti-Ta-Nb coatings consisted of dense nanoscale grains in the range of 30 to 100 nm with alpha-Ti crystal structure. The Ti-Ta-Nb disks and its sputtered nanoscale coatings exhibited greater hydrophilicity and rougher surfaces compared to the Ti-6Al-4V disks. The sputtered nanoscale Ti-Ta-Nb coatings exhibited significantly greater cell attachment compared to Ti-6Al-4V and Ti-Ta-Nb disks. Nanoscale Ti-Ta-Nb coatings exhibited significantly greater ALP specific activity and total protein production compared to the other 2 groups CONCLUSIONS. It was concluded that nanoscale Ti-Ta-Nb coatings enhance cell adhesion. In addition, Ti-Ta-Nb alloy and its nanoscale coatings enhanced osteoblast differentiation, but did not support osteoblast precursor proliferation compared to Ti-6Al-4V. These results indicate that the new developed Ti-Ta-Nb alloy and its nanoscale Ti-Ta-Nb coatings may be useful as an implant material.

A 3 year-retrospective study of survival rate in single $Br{\aa}nemark$ $TiUnite^{TM}$ implant (단일치아 결손시 $TiUnite^{TM}$ 표면처리한 임플란트의 생존율에 대한 후향적 단기연구)

  • Yang, Seung-Min;Park, Sun-Hye;Shin, Seung-Yun;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.671-679
    • /
    • 2007
  • Background: $TiUnite^{TM}$ is a highly crystalline and phosphate enriched titanium oxide surface which has a unique porous surface structure. This improved implant surface enhances bone response and reduces healing period. It also assures early stability of implant. These help to increase the success of implant. The aim of this study is to evaluate the survival rate of $TiUnite^{TM}$ surfaced single implant. Materials and methods: A retrospective analysis of 89 $TiUnite^{TM}$ surfaced implants replacing a single tooth was assessed according to their dental record. The age of the patients ranged from 17 to 82 years (mean age: $45.8{\pm}14.6)$. Data were recorded regarding the survival rate of these implants. Results: Fifty-two implants (57%) were placed in the maxilla, and 37 (43%) in the mandible. Over 75% were placed in the posterior area. Of the placed implants, 67% were the wide type. while 25% were the regular type and only 8% were of the narrow type. The single implants produced an overall clinical survival rate of 96.6% over the observation period (mean 17.9 months). Among 89 implants, only 2 implants were removed and one implant was submerged. Conclusion: According to these data, $TiUnite^{TM}$ surfaced implant in a single tooth restoration showed favorable survival rate although this study was done in a short term period.

A Two-dimensional Numerical Study of Hummingbird's Flight Mechanisms and Flow Characteristics (벌새의 비행메커니즘과 유동특성에 대한 2차원 수치해석 연구)

  • Lee, Hyun-Do;Kim, Jin-Ho;Kim, Chong-Am
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.729-736
    • /
    • 2009
  • In order to understand flow characteristics and flight mechanism of hummingbird's flapping flight, two-dimensional numerical analysis is carried out on the flapping motion of hummingbird, Selasphorus rufus. Hummingbird's flapping wing motion is realistically modeled from wind tunnel experimental data to perform numerical analysis. Numerical simulation shows that, as freestream velocity changes, wing trajectory is also adjusted and it substantially affects lift and thrust generation mechanism. According to this tendency, flight domain is separated as "low speed" and "high speed" regime, and each flight domain is studied for physical understanding. As a result, the lift generation during downstroke can be explained by the well-known effects, such as leading edge vortex effect, delayed stall, wake capture and so on. In addition, the lift generation during upstroke, the unique character of hummingbird, is also examined by detailed flow analysis. The thrust generation mechanism is investigated by examining the hummingbird's wing bone structure, vortex generation pattern and the resulting pressure gradient.

A STUDY ON AMALGAM CAVITY FRACTURE WITH TWO DIMENSIONAL FINITE ELEMENT METHOD I : VARIATION OF THE WIDTH OF CAVITY (아말감 와동의 파절에 관한 2차원 유한요소법적 연구 I : 와동 폭의 변화)

  • Kim, Han-Wook;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.655-669
    • /
    • 1995
  • Restorative procedures can lead to weakening tooth due to reduction and alteration of tooth structure. It is essential to prevent fractures to conserve tooth. Among the several parameters in cavity designs, cavity isthmus is very important. In this study, amalgam 0 cavity was prepared on maxillary first premolar. Two dimensional finite element models were made by serial photographic method and isthmus(1/4, 1/3, 1/2, 2/3 of intercuspal distance) were varied. Three or four-nodal mesh were used for the two dimensional finite element models. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. 1S model was sound tooth with no amalgam cavity. B model was assumed perfect bonding between the restoration and cavity wall. Both compressive and tensile forces were distributed directly to the adjacent regions. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed von Mises stress, 1 and 2 directional normal stress and Y and Z axis translation with FEM software Super SAPII Version 5.2 (Algor Interactive System Co.) and hardware 486 DX2 PC. The results were as :follows : 1. 1S model was slightly different with 1B model in stress distibution. 1S, 2B, 3B, 4B models showed similiar stress distribution. 2. 1S model and four B models showed similiar pattern in Y axis and Z axis translation. 3. 1S model and four B models showed the bending phenomenon in the translation. 4. As increasing of the width of the cavity, experimental group was similiar with the control group in stress distribution. 5. As increasing of the width of the cavity, experimental group was similiar with the control group in Y and Z axis tranlation.

  • PDF

Design and Evaluation of Osseointegration Analysis System for Dental Implant (치과 임플란트용 골융합 측정기의 설계 및 평가)

  • Lee, Joo-Hee;Kim, Chang-Il;Paik, Jong-Hoo;Cho, Jeong-Ho;Chun, Myoung-Pyo;Jeong, Young-Hun;Lee, Young-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.188-193
    • /
    • 2011
  • The osseointegration of dental implant is influenced by many factors such as surface geometry, loading and the amount of bone. Thus, stability of the dental implant should be checked periodically. In order to test the stability of dental implant by using resonance frequency analysis, we designed a structure of transducers and fabricated a piezoelectric devices. Using finite element analysis, the thickness and length of piezoelectric device and transducers were tailorized and the optimized frequency of 10 kHz was obtained. The resonance frequency from simulation analysis and evaluation was estimated to be similar as 10 kHz. The osseointegration was further enhanced with increasing frequency from the evaluation result of the finite element analysis.

Introduction of Specific Interaction of Hydroxyapatite/Polylactide Composites (수산화인회석과 폴리락타이드 복합체에서 상호작용력의 도입)

  • Kang, Jin-Kyu;Lim, Jun-Heok;Moon, Myong-Jun;Lee, Won-Ki;Kim, Mi-Ra;Lee, Jin-Kook
    • Polymer(Korea)
    • /
    • v.33 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • To increase mechanical properties of the hydroxyapatite/poly (L-lactide) (HA/PLLA) composite which was a potential bone substitute material, HA was modified by the surface grafting with D-lactide (DLA) and the formation of stereocomplexes between components was introduced. The composite films were prepared by the solvent-nonsolvent technique to minimize the precipitation of HA during drying. The structure and properties of the composites were investigated by thermal gravimetric analysis (TGA), differential scanning calorimeter, and scanning electron microscopy, and mechanical property measurements. TGA results showed that the amount of DLA grafted on the HA surfaces (g-HA) was 6 wt%. The obtained g-HA exhibited better dispersity in an organic solvent than HA. The formation of stereocomplexes in the composites was confirmed by the change in melting temperature. The mechanical properties of g-HA/PLLA composites were increased, compared to the HA/PLLA composites.

Convergence Study on Durability Analysis of Scooter Seat (스쿠터 시트의 내구성 해석에 관한 융합 연구)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.6
    • /
    • pp.165-170
    • /
    • 2019
  • This study carried out the structural analysis and vibration analysis on scooter seat. By comparing with three kinds of B-bone A, Julio B, and City Ace C, the load was applied to scooter seat as much as a weight of person. Through structural analysis, this study examined which seat is most deformed by comparing the deformation each other or affords passengers most convenience and does not afford passengers the inconvenience by absorbing the vibration during driving. Model C has the most total deformation at the structural analysis result and Model B is seen to be changed to be convenient to sit the deformation as it deforms largely. Through this study, which seat is most convenient and becomes strong on durability can be confirmed. As the durability analysis result data of scooter seat model obtained on the basis of this study result are utilized, the esthetic sense can be shown by being grafted onto the machine or structure at real life.

Clinical and radiographic features of facial cosmetic materials: A systematic review

  • Alsufyani, Noura;Aldosary, Reem;Alrasheed, Rasha;Alsufyani, Mohammed
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.155-164
    • /
    • 2022
  • Purpose: The aim of this study was to systematically screen the literature for studies reporting cosmetic material in the oral and maxillofacial complex to shed light on the types of cosmetic materials, their radiographic appearance, and possible complications. Materials and Methods: Five electronic databases were reviewed for eligible studies. The general search terms were "cosmetic," "filler," "face," and "radiograph." Demographics, material types, clinical and radiographic presentation, and complications were recorded. Results: Thirty-one studies with 53 cases met the inclusion criteria. The mean age was 52.6±15.4 years with a 4 : 3 female-to-male ratio. The most common material was calcium hydroxyapatite (CaHa) (n=14, 26.4%), found incidentally. The materials were generally located within the upper cheek and zygoma (n=35, 66.0%), radiographically well-defined (n=44, 83%), and had no effects on the surrounding structures (n=27, 50.9%). The internal structure was radiopaque (calcification, hyperdensity) for gold wires, CaHa, bone implants, and secondary calcification or ossification. Outdated cosmetic materials or non-conservative techniques were infiltrative, had effects on the surrounding structures, and presented with clinical signs, symptoms, or complications. Conclusion: Conventional radiography, cone-beam computed tomography, and multi-detector computed tomography are useful to differentiate several cosmetic materials. Their magnetic resonance imaging appearance was highly variable. The infrequent inclusion of cosmetic materials in the differential diagnosis implies that medical and dental specialists may be unfamiliar with the radiographic appearance of these materials in the face.

Micro-computed tomography in preventive and restorative dental research: A review

  • Ghavami-Lahiji, Mehrsima;Davalloo, Reza Tayefeh;Tajziehchi, Gelareh;Shams, Paria
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.341-350
    • /
    • 2021
  • Purpose: The use of micro-computed tomography (micro-CT) scans in biomedical and dental research is growing rapidly. This study aimed to explore the scientific literature on approaches and applications of micro-CT in restorative dentistry. Materials and Methods: An electronic search of publications from January 2009 to March 2021 was conducted using ScienceDirect, PubMed, and Google Scholar. The search included only English-language articles. Therefore, only studies that addressed recent advances and the potential uses of micro-CT in restorative and preventive dentistry were selected. Results: Micro-CT is a tool that enables 3-dimensional imaging on a small scale with very high resolution. In this method, there is no need for sample preparation or slicing. Therefore, it is possible to examine the internal structure of tissue and the internal adaptation of materials to surfaces without destroying them. Due to these advantages, micro-CT has been recommended as a standard imaging tool in dental research for many applications such as tissue engineering, endodontics, restorative dentistry, and research on the mineral density of hard tissues and bone growth. However, the high costs of micro-CT, the time necessary for scanning and reconstruction, computer expertise requirements, and the enormous volume of information are drawbacks. Conclusion: The potential of micro-CT as an emerging, accurate, non-destructive approach is clear, and the valuable research findings reported in the literature provide an impetus for researchers to perform future studies focusing on employing this method in dental research.

Mineral composition and phosphorus digestibility in feed phosphates fed to pigs and poultry

  • Su A, Lee;Diego A., Lopez;Hans H., Stein
    • Animal Bioscience
    • /
    • v.36 no.2
    • /
    • pp.167-174
    • /
    • 2023
  • Phosphorus (P) is a macro mineral needed for bone mineralization and cell membrane structure and P is also involved in several fundamental pathways of metabolism in the body. Because of the low concentration and digestibility of P in plant ingredients that are the main components of diets for poultry and pigs, feed phosphates are usually included in diets in addition to the P contributed by plant ingredients. The most widely used feed phosphates in poultry and swine diets are dicalcium phosphate (DCP) and monocalcium phosphate (MCP), but tricalcium phosphate (TCP), monosodium phosphate (MSP), and magnesium phosphate (MgP) may be used as well. Because feed phosphates are mostly produced from rock phosphate, feed phosphates have impurities that contain minerals other than P. Concentrations of P in feed phosphates range from 14.8% (MgP) to 25.7% (MSP). The standardized total tract digestibility (STTD) of P in pigs ranges from 71% (TCP) to 95% (MSP). The STTD of Ca and the standardized ileal digestibility (SID) of P and Ca in feed phosphates fed to pigs and poultry have been determined only in a few experiments. Available data indicate that the STTD of Ca and SID of P in MCP are greater than in DCP in both poultry and pigs, but the SID of Ca is similar between DCP and MCP fed to broilers. Information on mineral concentrations and digestibility values in feed phosphates is needed in diet formulation for pigs and poultry, but if diets are formulated to contain equal concentrations of digestible P and Ca, it is unlikely that animal performance will be impacted by the source of feed phosphates used in the diet.