• Title/Summary/Keyword: Bone Structure

Search Result 541, Processing Time 0.028 seconds

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

A Study on the Tissue Response and Bone Formation after Augmentation Using Proplast and Porous Polyethylene in Rabbit Mandible (Proplast와 Porous Polyethylene을 이용(利用)한 가토(家兎) 하악골(下顎骨) 증대술후(增大術後) 조직반응(組織反應) 및 골형성(骨形成)에 관(關)한 연구(硏究))

  • Kim, Geon-Jung;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.101-116
    • /
    • 1989
  • Proplast and Porous Polyethylene which have porous structures as low-modulus polymers have been recently used in maxillofacial plastic and reconstructive surgery. The purpose of this study was to compare the response of adajacent tissue, new bone formation and stability after augmentation by differen methods of subperiosteal graft using proplast and purous polythylene in rabbit mandible. The augmentation procedure was carried out by dividing into two groups, A and B. A group consisted of subperiosteal graft on the cortex, and the other B group was made up only graft following artificial decortication in the mandibular body of rabbit. The experimental animals were sacrificed on the 1st, 2nd, 4th and 8th week after grafting for macroscopic and light microscopic examination. The samples extracted at the 6th postgrafting week were also used for biometric testing and scanning electron microscopic examination. The results obtained from this study were as follows : 1. Macroscopically, infection of graft site, deformation and migration of graft material were not observed in all experimental groups. 2. B group showed more rapid and increased bone formation and the greater stability than A group, and tissue response was similar to each other. 3. In the tissue response, macrophages and cellular infiltrations were observed in Proplast group, but few in PHDPE group. 4. In bone formation of A group, Proplast group showed no bone formation until the 8th week, but PHDPE group showed small quantity of osteoid tissue from the 2nd week and appositional bone growth with new bone formation at the 8th week. 5. In bone formation of B group, both Proplast and PHDPE group showed bone formation, but PHDPE group showed more rapid and larger bone formation. 6. In pattern of bone formation, Proplast group mainly showed appositional bone growth pattern connected with graft site. On the other hand, PHDPE group showed mixed pattern of new bone formation in the pore connective tissue with appositional bone growth from graff site. 7. The maximum mean values of shear stress were serially $111.3gf/mm^{2}$ in PHDPE of B group, $84.8gf/mm^{2}$ in PHDPE of A group, $32.9gf/mm^{2}$ in Proplast B group, and $15.7gf/mm^{2}$ in Proplast of A group. From above results, It was suggested that the capacity of bone formation and stability between bone and graft material were dependent on the pore size and structure of graft material itself, the state of graft site and tissue response.

  • PDF

The preliminary study for three-dimensional alveolar bone morphologic characteristics for alveolar bone restoration

  • Cho, Hyun-Jae;Jeon, Jae-Yun;Ahn, Sung-Jin;Lee, Sung-Won;Chung, Joo-Ryun;Park, Chang-Joo;Hwang, Kyung-Gyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.33.1-33.7
    • /
    • 2019
  • Background: The concept of the ideal morphology for the alveolar bone form is an important element to reconstruct or restore the in maximizing esthetic profile and functional alveolar bone restoration. The purpose of this preliminary study is to evaluate the normal alveolar bone structure to provide the standard reference and guide template for use in diagnosing for implant placement, determining the correct amount of bone augmentation in actual clinical practice and producing prostheses based on three-dimensional imaging assessment of alveolar bone. Methods: This study was included 11 men and 11 women (average age, 22.6 and 24.5 years, respectively) selected from among 127 patients. The horizontal widths of alveolar bone of maxilla and mandible were measured at the crestal, mid-root, and root apex level on MDCT (multi-detector computed tomography) images reconstructed by medical imaging software. In addition, tooth dimensions of the central incisors, canines, second premolars, and first molars of maxilla and mandible, including the horizontal width of the interdental alveolar bone crest, were also measured and statistically analyzed. Results: The horizontal alveolar bone width of the palatal side of maxilla showed a distinct increment from the alveolar bone crest to the apical region in both anterior and posterior areas. The average widths of the maxillary alveolar ridge were as follows: central incisor, 7.43 mm; canine, 8.91 mm; second premolar, 9.57 mm; and first molar, 12.38 mm. The average widths of the mandibular alveolar ridge were as follows: central incisor, 6.21 mm; canine, 8.55 mm; second premolar, 8.45 mm; and first molar, 10.02 mm. In the buccal side, the alveolar bone width was not increased from the crest to the apical region. The horizontal alveolar bone width of an apical and mandibular border region was thinner than at the mid-root level. Conclusions: The results of the preliminary study are useful as a clinical guideline when determining dental implant diameter and position. And also, these measurements can also be useful during the production of prefabricated membranes and customized alveolar bone scaffolds.

THE DEVELOPMENT OF INTERPRETATION FOR TEMPOROMANDIBULAR JOINT ROENTGENOGRAMS (악관절증 환자의 X선사진 판독법 개발에 관한 연구)

  • You Dong-Soo;Ahn Hyung-Kyu;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.121-134
    • /
    • 1984
  • The authors analyzed the morphological change of bone structure from 3,140 radiographs (1570 joints) of 785 patients with temporomandibular joint arthrosis, which were obtained by the oblique lateral transcranial projection and orthopantomographs. The interrelation of bone change and clinical symptoms, duration of the diseases were examined. Also, the bone changes of articular eminence, condyle, articular fossa were examined according to positional change of the condyle in the mouth open and close state. The results were as follows. 1. In the 785 patients with TMJ arthrosis, 782 patients (99.62%) show the positional change of the condyle. Among them 691 patients (88.03%) show the bone change. 2. In TMJ arthrosis patients with bone changes 451 patients (65.27%) showed both the condylar positional changes and bone changes bilaterally. 198 patients (28.65%) show the condylar positional changes bilaterally and bone changes unilaterally. 3. The bone changes in the TMJ arthrosis were in order of frequency eburnation (647 cases, 32.8%), erosion (548 cases, 27.79%), flattening (418 cases, 21.20%), deformity (138 cases, 6.99%). sclerosis (115 cases, 5.83%), marginal proliferation (106 cases, 5.38%). The region of bone change in TMJ arthrosis with condylar positional changes were in order of frequency the articular eminence (43.97%) condylar head (38.64%), articular fossa (17.39%). In the patients with bone changes, their clinical symptoms were pain (44.34%), clicking sound (33.5%), limitation of mouth opening (22.52%). In the patients complaining pain the most frequent bone change was erosion (28.60%), in the patients complaining clicking sound, eburnation (28.97%) in the patients complaining the limitation, eburnation (29.40%). Also in the patients with the duration below 1 year most common bone change was eburnation. 5. The most common condylar positional change was downward position (39.94%) in closed state, restricted movement of condyle (30.07%) in open state. The condylar positional changes and bone changes according to the region were as follows: a) In the condylar head the most frequent bone change was erosion (30.45%) and the most frequent condylar positional change was downward position (37.40%) in closed state, restricted movement of condyle (33.2%) in open state. b) In the articular eminence the most frequent bone change was eburnation (39.91%) and the most frequent condylar positional change was downward position (39.79%) in closed state, restricted movement of condyle (27.22%) in open state. c) In the articular fossa the most frequent bone change was eburnation (53.94%) and the most frequent condylar positional change was downward position (42.57%) in closed state, restricted movement of condyle (30.32%) in open state.

  • PDF

In vivo Evaluation of Osteoporotic Fracture Prevention of the site to which low Intensity Ultrasound is Irradiated using Mechanical Strength Simulations (역학적 강도 분석을 이용한 저강도 초음파의 조사 부위의 골다공증 골절 방지 효과 평가)

  • Woo, Dae-Gon;Kim, Chi-Hoon;Park, Ji-Hyung;Ko, Chang-Young;Kim, Han-Sung;Kim, Jin-Man;Kim, Sang-Hee;Lim, Do-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.135-141
    • /
    • 2009
  • Purpose: The aim of present study is to evaluate a possibility of clinical application for the effect of low intensity ultrasound stimulation (LIUS) in mechanical characteristics of bone on osteoporotic fractures prevention. Materials and Methods: Eight virgin ICR mice (14 weeks old, approximate weight 25g) were ovariectomized (OVX) to induce osteoporosis. The right hind limbs were then stimulated with LIDS (US Group), whereas left hind limbs were not stimulated (CON Group). Both hind limbs of all mice were scanned by in-vivo micro-CT to acquire two-dimensional (2D) images at 0 week before stimulation and 3 weeks and 6 weeks after stimulation. Three-dimensional (3D) finite element (FE) models generated by scanned 2D images were used to determine quantitatively the effect of LIUS on strength related to bone structure. Additionally, distributions of Hounsfield units and elastic moduli, which are related to the bone quality, for the bones in the US and CON groups were determined to analyze quantitatively a degree of improvement of bone qualities achieved by LIUS. Results: The result of FE analysis showed that the structural strength in US Group was significantly increased over time (p<0.05), while that in CON Group was statistically constant over time (p>0.05). High values of Hounsfield units obtained from voxels on micro-CT images and high values of elastic moduli converted from the Hounsfield units were dominantly appeared in US Group compared with those in CON Group. Conclusion: These finding indicated that LIUS would improve the mechanical characteristics of osteoporotic bone via the effects of bone structure (bone strength) and quality (Hounsfield unit and elastic modulus). Therefore, the LIUS may decrease effectively the risk of osteoporotic fracture in clinics.

Finite element stress analysis on supporting bone by tripodal placement of implant fixture (유한요소법을 이용한 임플란트 고정체의 삼각배열에 따른 지지골의 응력 분석)

  • Son, Sung-Sik;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: This study was to propose the clear understanding for stress distribution of supporting bone by use of staggered buccal offset tripodal placement of fixtures of posterior 3 crown implant partial dentures. We realized posterior 3 crown implant fixed partial dentures through finite element modeling and analysed stress effect of implant arrangement location to supporting bone under external load using finite element method. Method: To understand stress distribution of 3 crown implant fixed partial dentures which have 2 different arrangement by finite element analysis. In each model, for loading condition, we applied $45^{\circ}$ oblique load to occlusal surface of crown and applied 100 N for 3 crown individually(total 300 N) for imitating possible oral loading condition. at this time, we calculated Von Mises stress distribution in supporting bone through finite element method. Result: When apply $45^{\circ}$ oblique load to in-line arrangement model, maximum stress result for 100 N for each 3 crown 47.566MPa. In tripodal placement, result for 1mm buccal offset tripodal placement implant model was maximum distributed load 51.418MPa, so result was higher than in-line arrangement model. Conclusion: In stress distribution result by placement of implant fixture, the most effective structure was in-line arrangement. The tripodal placement does not effective for stress distribution, gap cause more damage to supporting bone.

  • PDF

Electrochemical Behaviors of PEO-treated Ti-6Al-4V Alloy in Solution Containing Zn and Si Ions

  • Hwang, In-Jo;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.160-160
    • /
    • 2017
  • Commercially pure titanium (Cp-Ti) and Ti alloys (typically Ti-6Al-4V) display excellent corrosion resistance and biocompatibility. Although the chemical composition and topography are considered important, the mechanical properties of the material and the loading conditions in the host have, conventionally. Ti and its alloys are not bioactive. Therefore, they do not chemically bond to the bone, whereas they physically bond with bone tissue. The electrochemical deposition process provides an effective surface for biocompatibility because large surface area can be served to cell proliferation. Plasma electrolyte oxidation (PEO) enables control in the chemical composition, porous structure, and thickness of the TiO2 layer on Ti surface. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation, and is also the most abundant trace element in bone. The objective of this work was to study on electrochemical behaviors of PEO-treated Ti-6Al-4V Alloy in solution containing Zn and Si ions. The morphology, the chemical composition, and the microstructure analysis of the sample were examined using FE-SEM, EDS, and XRD. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat. The promising results successfully demonstrated the immense potential of Si/Zn-TiO2 coatings in dental and biomaterials applications.

  • PDF

Fracture Analysis of Bone-Like Materials Using J integral (J 적분을 이용한 뼈와 유사한 재료의 파괴 해석)

  • Lee, Chang-Woo;Lin, Song;Beom, Hyeon-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.9
    • /
    • pp.52-57
    • /
    • 2010
  • The analysis of a crack in a bone-like material is performed numerically. The bone-like material is hierarchically structured and each hierarchy is structured by mineral platelets and protein matrix through staggered arrangement. Mechanical behavior of the composite can be analyzed using tension shear chain model. The Dugdale model is adopted to evaluate the fracture energy of Bone-like material. The fracture energy dissipation is assumed to concentrate within a strip near the crack tip along the prospective crack path. Fracture criterion of the bone-like material is estimated by using J integral. Effects of hierarchical level, ratio of elastic modulus of mineral to protein, aspect ratio of mineral platelet and volume fraction on J integral are investigated. It is found that the J integral decreases as elastic modulus ratio and hierarchy level increase. It is also shown that the J integral increases as the volume fraction and aspect ratio decrease.

Silk Fibroin Membrane as Guided Bone Regeneration in Rat Calvarial Defects

  • Kweon, Hae-Yong;Kim, Seong-Gon;An, Jin-Hee;Shim, Hye-Won;Yang, Byoung-Eun;Kim, Jwa-Young;Jo, You-Young;Yeo, Joo-Hong;Lee, Kwang-Gill
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.21 no.2
    • /
    • pp.175-179
    • /
    • 2010
  • Silk fibroin membrane was prepared and examined to know the feasibility of SF membrane as guided bone regeneration. The morphology of silk membrane was flat and smooth surface. The conformation of silk fibroin was $\beta$-sheet structure. When the silk membrane was applied on the rat calvarial defect model, it showed significantly higher new bone formation than uncovered control in histomorphometric analysis. The silk membrane was covered by thin fibrotic tissue and there was not observed any inflammatory cells infiltration. In conclusion, silk fibroin membrane could be useful materials for guided bone regeneration.