• Title/Summary/Keyword: Bone Plate

Search Result 555, Processing Time 0.025 seconds

Clavicle Nonunion: Matchstick Bone-grafting and Osteosynthesis

  • Park, Yong Bok;Yoo, Jae Chul;Park, Geun Min;Kum, Dong Ho;Tauheed, Mohammed;Jeong, Jeung Yeol
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Background: This study was conducted to evaluate the surgical outcomes of plate fixation using autologous iliac bone graft shaped in the form of a matchstick in clavicle nonunion resulting from prior surgical or non-surgical management. Methods: From May 2005 to February 2013, 17 patients underwent surgery for clavicle nonunion. The mean age at the time of surgery was 48.8 years. The iliac bone was harvested and shaped into slivers approximately 3 cm long, which resembled matchsticks. After opening of the medullary canal, the plate and screws were applied and cancellous bone was placed at the nonunion site. Matchstick bone grafts which were longitudinally placed and encircled on the nonunion site were tied with periosteum using 3-4 stitches. Union was determined via postoperative plane X-ray. Clinical status was evaluated using the visual analogue scale score for pain, and Constant and American Shoulder Elbow Surgeon score. Results: All patients had a stable radiological union at the follow-up. The mean duration from index operation to nonunion operation was 13.2 months (7-32 months). The mean follow-up period was 20.1 months (8-56 months), and the mean duration until union was 11.2 weeks (8-16 weeks). All clinical scores were improved at the final follow-up (p<0.001). The mean segmental defect was $3.3{\pm}2.6mm$ (1-18 mm); and the difference in clavicular length between operative and non-operative site was $5.9{\pm}6.9mm$. Conclusions: Matchstick shaped autologous iliac bone grafting technique in clavicle nonunion is acceptable with a high union rate.

Guided Bone Regeneration in Comminuted Long-Bone Fractures Using Recombinant Human Bone Morphogenetic Protein-2 and a Collagen Membrane

  • Jang, Kwangsik;Jo, Hyun Min;Shim, Kyung Mi;Kim, Se Eun;Kang, Seong Soo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.59-64
    • /
    • 2022
  • A dog aged two years and seven months and a cat aged seven years were referred owing to fractures of long bones. Preoperative radiographs revealed comminuted bone fractures close to joints. Conventionally, long-bone fractures are treated using intramedullary pins, plate and screw systems, or an external fixator system. In cases of non-reducible fractures, various graft materials have been used in fracture treatments to stimulate bone repair. Here, recombinant human bone morphogenetic protein-2 (rhBMP-2) and a collagen membrane were applied. Four weeks after surgery, fractured bone fragments began to unite and the bone union was observed using radiography four months after surgery. No complications occurred related to grafted materials. We successfully applied rhBMP-2 and collagen membranes in two different species to support the healing process of comminuted fractures, according to the concept of guided bone regeneration.

Economical Analysis of Cervical Disc Disease by Anterior Inter-body Fusion Methods - Comparing of Bone Graft vs Plating - (경추간판 탈출 환자의 전방 고정술에 따른 경제적 분석 - 골 이식법과 금속판 고정 병행술의 비교 -)

  • Gill, Seung-Bae;Lee, Sang-Youl;Heo, Seung-Ho;Jang, Yeun-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.201-206
    • /
    • 2001
  • Objective : The purpose of this study was to assess the complications, duration of admission, cost effectiveness, radiologic stabilization of the anterior cervical bone fusion in the treatment of cervical disc disease with and without plating. Materials and Methods : Fifty-two surgically treated patients for cervical disc disease were reviewed. Group I consisted of consecutive treated patients with iliac auto-bone graft without instrumentation after anterior cervical discectomy. Group II consisted of consecutive treated patients with iliac autologous-bone graft with CASPER cervical plate fixations. Radiologic fusion was decided when loss of end plate boundary between graft bone and vertebral body and immobile, maintenance of the disc space were evident on simple dynamic plain films. The patients were discharged after the stabilization of cervical motion by films was of tained. These groups were analysed multiple variably with Mann-Whitney U-test. Results : Group I consisted of 18 patients, group II consisted of 34 patients. Mean age was $49.0{\pm}8.1years$, mean duration of admission was $17.27{\pm}10.51days$, mean costs for treatment was $1,970,000{\pm}475,000won$. In group I, mean age was 47.7(34-60) years, 16 patients had undergo on one-level operation, 2-patients had undergo on two-level operation, mean duration of admission was $28.7{\pm}10.4days$, mean costs for treatment was $2,194,473{\pm}561,639won$. The periods of stabilization was $6.6{\pm}3.36weeks$ on radiologic study. Mean periods of out patient follow up was 16.8(6-64) weeks after discharge. Mean period of radiologic follow up was 17.3(4-6) weeks after surgical operation. In group II, mean age was 49.7(37-62) years and 18 patients one-level operation, 14- patients had undergo on two-level operation and 2-patients three-level operation. Mean duration of admission was $11.24{\pm}3.29days$, mean costs for treatment was $1,850,823{\pm}389,372won$. The periods of stabilization was $5.88{\pm}7.07weeks$ on radiologic study. Mean period of out patients follow up was 16.7(4-60) weeks after discharge. Mean period of radiologic follow up was 12.4(3-52) weeks after surgical operation. The duration of admission showed statistical significance in Group II but other items showed no significant difference between two groups. Conclusions : The more economic, early life return and effective method of cervical disc disease in our series were evident in patients who had undergone, iliac bone graft and plate fixations after anterior discectomy.

  • PDF

Three-dimensional finite element analysis on the effects of maxillary protraction with an individual titanium plate at multiple directions and locations

  • Fan Wang;Qiao Chang;Shuran Liang;Yuxing Bai
    • The korean journal of orthodontics
    • /
    • v.54 no.2
    • /
    • pp.108-116
    • /
    • 2024
  • Objective: A three-dimensional-printed individual titanium plate was applied for maxillary protraction to eliminate side effects and obtain the maximum skeletal effect. This study aimed to explore the stress distribution characteristics of sutures during maxillary protraction using individual titanium plates in various directions and locations. Methods: A protraction force of 500 g per side was applied at forward and downward angles between 0° and 60° with respect to the Frankfort horizontal plane, after which the titanium plate was moved 2 and 4 mm upward and downward, respectively. Changes in sutures with multiple protraction directions and various miniplate heights were quantified to analyze their impact on the maxillofacial bone. Results: Protraction angle of 0-30° with respect to the Frankfort horizontal plane exhibited a tendency for counterclockwise rotation in the maxilla. At a 40° protraction angle, translational motion was observed in the maxilla, whereas protraction angles of 50-60° tended to induce clockwise rotation in the maxilla. Enhanced protraction efficiency at the lower edge of the pyriform aperture was associated with increased height of individual titanium plates. Conclusions: Various protraction directions are suitable for patients with different types of vertical bone surfaces. Furthermore, when the titanium plate was positioned lower, the protraction force exhibited an increase.

Histopathological Studies on the Effect of Korean Safflower (Carthamus tinctorious L.) Seed Powder on Cadmium Poisoning in Mice (홍화씨분말이 카드뮴 중독에 미치는 병리조직학적 관찰)

  • 장종식;권오덕
    • Journal of Veterinary Clinics
    • /
    • v.18 no.2
    • /
    • pp.116-123
    • /
    • 2001
  • This study was undertaken to find out the effect of Korean safflower seed powder on histopathological changes of cadmium toxicity in mice. Fifty BALB/c mice were divided into a control group(A) and four experimental groups(B, C, D, E) : group A received tap water and basal diet, group B received tap water and diet supplemented with 3% Korean safflower seed powder alone, group C received basal diet and 300 $\mu\textrm{g}$/g of cadmium, group D and E received basal diet supplemented with 3% and 10% Korean safflower seed powder and 300$\mu\textrm{g}$/g of cadmium respectively. Cadmium dissolved in tap water was used, and the Korean safflower seed powder were mixed with feed. All mice were dissected on the 56th day. Histopathological changes in liver, kidney, lung, cortical osseous tissue of femoral shaft, bone trabecular of femur, and epiphyseal cartilage plate of femur were observed. Group B showed no significant changes compared with the control group. But group C showed the unclearness of specific cells in liver, the loss of architecture and focal necrosis of hepatocyte, the glomerular swelling, degeneration and necrosis of convoluted tubules, desquamation and vacuolization of the greater part of the renal tubular epithelium, the marked congestion and thickness of the wall of alveolus in lung, slightly thinning of the cortical osseous tissue in femoral shaft, reduction of cancellous bone volume and marked narrowness of bone trabecular, marked thinning of epiphyseal cartilage plate and irregular arrangement of columnar structure of cartilage cells. On the other hand, Korean safflower seed powder-treated group showed a little convalescent changes and maintained their normal architectures in liner, kidney, lung, cortical osseous tissue of femoral shaft, bone trabecular of femur and epiphyseal cartilage plate of femur.

  • PDF

Polyetheretherketone Cage with Demineralized Bone Matrix Can Replace Iliac Crest Autografts for Anterior Cervical Discectomy and Fusion in Subaxial Cervical Spine Injuries

  • Kim, Soo-Han;Lee, Jung-Kil;Jang, Jae-Won;Park, Hyun-Woong;Hur, Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.211-219
    • /
    • 2017
  • Objective : This study aimed to compare the clinical and radiologic outcomes of patients with subaxial cervical injury who underwent anterior cervical discectomy and fusion (ACDF) with autologous iliac bone graft or polyetheretherketone (PEEK) cages using demineralized bone matrix (DBM). Methods : From January 2005 to December 2010, 70 patients who underwent one-level ACDF with plate fixation for post-traumatic subaxial cervical spinal injury in a single institution were retrospectively investigated. Autologous iliac crest grafts were used in 33 patients (Group I), whereas 37 patients underwent ACDF using a PEEK cage filled with DBM (Group II). Plain radiographs were used to assess bone fusion, interbody height (IBH), segmental angle (SA), overall cervical sagittal alignment (CSA, C2-7 angle), and development of adjacent segmental degeneration (ASD). Clinical outcome was assessed using a visual analog scale (VAS) for pain and Frankel grade. Results : The mean follow-up duration for patients in Group I and Group II was 28.9 and 25.4 months, respectively. All patients from both groups achieved solid fusion during the follow-up period. The IBH and SA of the fused segment and CSA in Group II were better maintained during the follow-up period. Nine patients in Group I and two patients in Group II developed radiologic ASD. There were no statistically significant differences in the VAS score and Frankel grade between the groups. Conclusion : This study showed that PEEK cage filled with DBM, and plate fixation is at least as safe and effective as ACDF using autograft, with good maintenance of cervical alignment. With advantages such as no donor site morbidity and no graft-related complications, PEEK cage filled with DBM, and plate fixation provide a promising surgical option for treating traumatic subaxial cervical spine injuries.

Bone Replacement and Grafting with a Biologically Active Ceramic Composite

  • McGee, Thomas Donald
    • The Korean Journal of Ceramics
    • /
    • v.7 no.1
    • /
    • pp.41-44
    • /
    • 2001
  • A composite of $Ca_3$(PO$_4$)$_2$ and MgAl$_2$O$_4$ spinel is biologically active and has enduring strength. Its strength depends on the spinel phase. The flaws in the spinel depend on the grain size of the calcium phosphate phase and are not altered by dissolution. The calcium phosphate, ${\alpha}$ tri-calcium phosphate, controls the tissue response. Bone bonds to the implant. A design for a bone graft as a replacement for a section of the diaphysis of a canine femur provides for tensile, compressive, torsional and bending load; and for the physiological processes of bonding and remodeling. A bone plate, used to stabilize the implant at time of surgery was removed after about one year. Over seven years of service have been achieved without internal or external fixation.

  • PDF

Accuracy Analysis of Bone Age Assessment by the Number of Epiphyseal Plates (골단판 수에 따른 뼈 나이 측정 결과의 정확성 분석)

  • Kwon, Jae-Sung;Kim, Hyoung-Joon;Lee, Jong-Min;Kim, Whoi-Yul
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.395-396
    • /
    • 2007
  • Bone age assessment has been widely used to measure the ossification in pediatric radiology. For the assessment, first bone age of each epiphyseal plate is estimated using DCT/LDA, then the bone age of a patient is calculated by using the median of 9 estimations. For some patients, however, due to various reasons such as X-ray image quality or the pose of fingers, it is common to miss couple of plates in automated systems. In this paper, we investigate the relationship between the number of detected plates and the accuracy of bone age assessment. In the experimental results, we confirmed the similarity between bone age assessed using more than 7 epiphyseal plates and that assessed using 9 epiphyseal plates.

  • PDF