• 제목/요약/키워드: Bone Conduction Implant

검색결과 7건 처리시간 0.026초

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • Journal of Audiology & Otology
    • /
    • 제24권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • 대한청각학회지
    • /
    • 제24권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

Safety and efficacy of transcutaneous bone conduction implant surgery for hearing improvement in microtia patients with bilateral hearing impairment

  • Cheon, Jeong Hyun;Lee, Hyung Chul;Im, Gi Jung;Park, Jung Youl;Park, Chul
    • Archives of Plastic Surgery
    • /
    • 제46권6호
    • /
    • pp.525-534
    • /
    • 2019
  • Background In microtia patients with bilateral hearing impairment, hearing improvement is crucial for language development and performance. External auditory canal reconstruction (EACR) has been performed to improve hearing, but often results in complications. We performed transcutaneous bone conduction implant (TBCI) surgery in these patients. This study aimed to evaluate the safety and efficacy of TBCI surgery. Methods A retrospective review was performed of five patients who underwent auricular reconstruction and TBCI surgery and 12 patients who underwent EACR between March 2007 and August 2018. Hearing improvement was measured based on the air-bone gap values using pure-tone audiometry over a 6-week postoperative period. We reviewed other studies on hearing improvement using EACR and compared the findings with our results. The surgical techniques for TBCI were reviewed through case analyses. Results Postoperative hearing outcomes showed a significant improvement, with a mean gain of 34.1 dB in the TBCI cohort and 14.1 dB in the EACR cohort. Both gains were statistically significant; however, the TBCI cohort showed much larger gains. Only three of the 12 patients who underwent EACR achieved hearing gains of more than 20 dB, which is consistent with previous studies. All patients who underwent TBCI surgery demonstrated hearing gains of more than 20 dB and experienced no device-related complications. Conclusions TBCI is a safe and effective method of promoting hearing gains in microtia patients with bilateral hearing impairment. TBCI surgery provided better hearing outcomes than EACR and could be performed along with various auricular reconstruction techniques using virgin mastoid skin.

FEA를 이용한 이식형 골전도 진동체의 주파수 특성 제어에 관한 파라미터 연구 (A Parameter Study on the Frequency Characteristics Control of Implantable Bone Conduction Transducer Using FEA)

  • 신동호;김명남
    • 한국멀티미디어학회논문지
    • /
    • 제23권8호
    • /
    • pp.1040-1048
    • /
    • 2020
  • In this study, in order to improve the implantable bone conduction transducer of the prototype proposed by Shin et al., the effect of the element parameters of the transducer on the frequency characteristics was analyzed using electromagnetic and mechanical vibration analysis. Electromagnetic analysis was performed on the size of the permanent magnet and the distance between the metal plate and the coil to derive an optimal structure that generates the maximum Lorentz force. In addition, mechanical vibration analysis was performed on the cantilever structure of the vibrational membrane in order to minimize the distortion of the transducer and to have a frequency characteristic suitable for conductive hearing loss compensation. The frequency characteristics of the transducer of the optimal structure derived through finite element method were compared with the simulation results of the previous transducer. As a result, the output magnitude (displacement) of the transducer designed with the optimal structure generated an average 8.8 times higher than the previous transducer, and the resonance frequency was generated at 0.9 kHz.

백서 복근에 매식된 동결 건조 및 방사선 멸균처리된 동종골의 조직 반응에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON TISSUE RESPONSE FOLLOWING IMPLANTATION OF THE FREEZE - DRIED AND RADIATION - STERILIZED ALLOGENEIC BONE IN RECTUS ABDOMINICUS MUSCLE)

  • 이창우;임창준;이동근;김수남
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제13권3호
    • /
    • pp.265-277
    • /
    • 1991
  • In this study, the healing changes of the implanted bone and its surrounding tissues were examined on the histopathologic basis following implantation of the freeze - dried and radiation - sterilized allogeneic bone in Rectus abdominicus of the rat. This study was performed to see the tissue recations after implantation of the freeze - dried and radiation - sterilized allogeneic bone and whether osteogenesis or osteo - induction or osteo - conduction is happened. And the results were as follows : 1. The shape of the implanted allogeneic bone of the 1, 2 - week group specimen was similar to that of normal bone in light - microscopic finding and the atrophy of cellular organells was found in trans - mission electron - microscopic finding. 2. The implanted allogeneic bone was surrounded with the dense fibroconnective tissues, and infiltration of the chronic inflammatory cells gradually became increased. 3. Hyaline degeneration was observed in the surrounding tissue at the 3, 4, 6 - week group specimen. 4. Light - microscopically the resorption of implanted bone became prominent after 4 - week group and the necrosis of allogeneic bone implant became severe with loss of cell components in lacuna. 5. Electron - microscopically, the osteoclast - like cells ere fond after, 2 - week group. It is summarized that the osteo - conduction potential of the bone is remained just after implanting the freeze - dried and radiation - sterilized allogeneic bone on Rectus abdominicus of the rat, but gradually it disappeared with the gradual increse of chronic inflammatory reaction and osteoclastic activity. So it is suggested that the antigenicity of the freeze - dried and radiation - sterilized bone is remained and it has little osteo - conductive activity when it is implanted in the muscle.

  • PDF

생분해성 Calcium Metaphosphate골이식재의 골조직재생효과에 관한 연구 (The effect of calcium metaphosphate bone graft materials on bone regeneration)

  • 채한승;이용무;양승민;천성수;김석영;구영;정종평;한수부;최상묵;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제33권1호
    • /
    • pp.13-26
    • /
    • 2003
  • Periodontal regeneration therapy with bone-substituting materials has gained favorable clinical efficacy by enhancing osseous regeneration in periodontal bony defect. As bone-substituting materials, bone powder, calcium phosphate ceramic, modified forms of hydroxyapatite, and hard tissue replacement polymer have demonstrated their periodontal bony regenerative potency. Bone-substituting materials should fulfill several requirements such as biocompatibility, osteogenecity, malleability, biodegradability. The purpose of this study was to investigate biocompatibility, osteo-conduction capacity and biodegradability of $Na_2O$, $K_2O$ added calcium metaphosphate(CMP). Beta CMP was obtained by thermal treatment of anhydrous $Ca_2(H_2PO_4)_2$. $Na_2O$ and $K_2O$ were added to CMP. The change of weight of pure CMP, $Na_2O$-CMP, and $K_2O$-CMP in Tris-buffer solution and simulated body fluid for 30 days was measured. Twenty four Newzealand white rabbits were used in negative control, positive control(Bio-Oss), pure CMP group, 5% $Na_2$-CMP group, 10% $Na_2O$-CMP goup, and 5% $K_2O$-CMP group. In each group, graft materials were placed in right and left parietal bone defects(diameter 10mm) of rabbit. The animals were sacrificed at 3 months and 6 months after implantation of the graft materials. Degree of biodegradability of $K_2O$ or $Na_2O$ added CMP was greater than that of pure CMP in experimental condition. All experimental sites were healed with no clinical evidence of inflammatory response to all CMP implants. Histologic observations revealed that all CMP grafts were very biocompatible and osseous conductive, and that in $K_2O$-CMP or $Na_2O$-CMP implanted sites, there was biodegradable pattern, and that in site of new bone formation, there was no significant difference between all CMP group and DPBB(Bio-Oss) group. From this result, it was suggested that all experimental CMP group graft materials were able to use as an available bone substitution.

Calcium sulfate제재가 치주인대세포에 미치는 영향 (The effects of calcium sulfate on periodontal ligament cells)

  • 이준호;김소영;최성호;채중규;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.235-247
    • /
    • 1998
  • Calcium sulfate has a long history of medical use as an implant material. The biocompatibiliry of the material has been clearly established. Bone ingrowth concomitant with resorption occurs rapidly with efficient conduction of bone from particle to particle. Calcium sulfate also has a potential for functioning as a good bamer membrane. The purpose of this study was to compare the biocompatibility of different types of calcium sulfate grafting materials including an expelimental calcium sulfate compound on periodontal ligament cells in vitro as a preliminary test towards the development of a more convenient and useful form of grafting material which could promote regeneration of periodontal tissue. Human periodontal ligament cells were collected from the premolar teeth extracted for orthodontic treatment. cells were cultured in a.MEM culture medium containing 20% FBS, at $37^{\circ}C$ and 100% humidity, in a 5% CO2 incubator. Cells were cultured into 96 well culture plate $1{\times}104$ cells per well with $\alpha$-MEM and incubated for 24 hours. After discarding the medium, those cells were cultured in $\alpha$-MEM contained with 10% FBS alone (control group), in medcal-grade calcium sulfate(MGCS group), in plaster(plaster group), experimental calcium sulfate paste(CS paste group) for 1, 2, 3 day respectively. And then each group was characterized by examining of the cell counting, MTI assay, collagen synthesis. The results \vere as follows. 1. In the analysis of cell proliferation by cell counting, both medical-grdde calcium sulfate group and plaster group showed no stastically significant difference at day 1, 2, 3 accept for plaster group at day 1 compared to control group, but there was stastically significant difference between CS paste group and all other groups at day 1, 2, 3(P<0.05). 2. In the analysis of cytotoxicity by MIT assay, both medical-grade calcium sJlfate group and plaster group showed no stastically significant difference compared to control group at day 1, 2, 3 but there was stastically significant difference between CS paste group and all other groups at day 1, 2, 3(P<0.OS). 3. In the analysis of collagen synthesis by immunoblotting assay, high level was detected for medical-grade calcium sulfate group and plaster group at day 1, 2, 3 compared to CS paste group. On the basis of these results, medical-grade calcium sulfate and plaster was shown to possess biocompatibility whereas the CS paste had unfavourable outcome. This observation shows a need for modification of the materials contained in calcium sulfate paste.

  • PDF