• 제목/요약/키워드: Bonded disc method

검색결과 6건 처리시간 0.023초

점도, 시편형태 그리고 접착의 유무가 광중합 복합레진의 선형중합수축의 측정에 미치는 영향 (THE EFFECT OF VISCOSITY, SPECIMEN GEOMETRY AND ADHESION ON THE LINEAR POLYMERIZATION SHRINKAGE MEASUREMENT OF LIGHT CURED COMPOSITES)

  • 이인복;손호현;권혁춘;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.457-466
    • /
    • 2003
  • The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow-were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bond-ed' free shrinkage method at varying C-factor in the range of 1∼8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. In non-bonded method, the linear shrinkage approximated one third of true volumetric shrink-age by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5∼6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.

The discrete element method simulation and experimental study of determining the mode I stress-intensity factor

  • Shemirani, Alireza Bagher;Haeri, Hadi;Sarfarazi, Vahab;Akbarpour, Abbas;Babanouri, Nima
    • Structural Engineering and Mechanics
    • /
    • 제66권3호
    • /
    • pp.379-386
    • /
    • 2018
  • The present study addresses the direct and indirect methods of determining the mode-I fracture toughness of concrete using experimental tests and particle flow code. The direct method used is compaction tensile test and the indirect methods are notched Brazilian disc test, semi-circular bend specimen test, and hollow center cracked disc. The experiments were carried out to determine which indirect method yields the fracture toughness closer to the one obtained by the direct method. In the numerical analysis, the PFC model was first calibrated with respect to the data obtained from the Brazilian laboratory test. The crack paths observed in the simulated tests were in reasonable accordance with experimental results. The discrete element simulations demonstrated that the macro fractures in the models are caused by microscopic tensile breakages on large numbers of bonded particles. The mode-I fracture toughness in the direct tensile test was smaller than the indirect testing results. The fracture toughness obtained from the SCB test was closer to the direct test results. Hence, the semi-circular bend test is recommended as a proper experiment for determination of mode-I fracture toughness of concrete in the absence of direct tests.

레진계 임시수복재의 중합수축, 수화팽창과 미세누출 (POLYMERIZATION SHRINKAGE, HYGROSCOPIC EXPANSION AND MICROLEAKAGE OF RESIN-BASED TEMPORARY FILLING MATERIALS)

  • 조낙연;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.115-124
    • /
    • 2008
  • 본 연구의 목적은 수 종의 레진계 임시수복재의 중합수축 및 수화팽창을 측정하고 레진계 임시수복재와 와동면 사이의 미세누출을 평가하고자 하였다. 본 실험의 재료는 5종의 광중합형 레진계 임시충전재 Fermit, Quicks, Provifil, Spacer, Clip와 대조군으로 석고계 충전재 Caviton을 사용하였다. 'Bonded disc method'를 이용하여 중합수축을 측정하였고, 미리 중합된 디스크 형태의 시편을 생리식염수에 담그고 LVDT로 7 일 동안 수화팽창을 기록하였다. 발거된 120개의 상, 하악 대구치에 1 급 와동을 형성한 후 각각 20개씩 6개의 군으로 나누어 각 재료를 충전한 후, 1000 회의 Thermocycling을 실시하고 2% methylene blue 염색 용액을 이용하여 미세누출을 평가하였다. 연구결과는 다음과 같다. 1. Fermit의 중합수축이 가장 적었고 (0.22%) Spacer (0.38%), Quicks (0.64%) Provifil (0.67%), Clip (0.67%) 의 순이었다. 2. 모든 재료는 24 시간 이내에 급격한 수화팽창을 나타냈고 7 일 후 수화팽창은 Caviton이 가장 컸다 (11.5%). 레진계 임시수복재는 0.43-1.1%가량 팽창하였다. 3. Fermit의 미세누출이 가장 많았으며 Quicks의 미세누출이 가장 적었다. Spacer와 Clip은 Caviton과 비슷한 정도의 미세누출을 보였다. 4. 중합수축 또는 수화팽창과 미세누출 사이의 직접적 인 상관관계는 관찰할 수 없었다.

Cefotaxime을 이용한 PVA/PAA 하이드로 겔 필름의 항균 특성 (Antibacterial Characteristics of PVA/PAA Hydrogel Film using Cefotaxime)

  • 염석재;정선도;오은하
    • 한국환경보건학회지
    • /
    • 제47권1호
    • /
    • pp.55-63
    • /
    • 2021
  • Objectives: Cefotaxime is an antibiotic used to treat several bacterial infections. Specifically, it is used to treat pelvic inflammatory disease, meningitis, pneumonia, urinary tract infections, and sepsis. It is given by injection into either a vein or muscle. Antibacterial polymers prepared by chemical bonding and simple blending of antibacterials into polymers has attracted much interest because of their long-lasting antibacterial activity. This study attempted to review the possibility of hydrogel films as functional antibacterial materials by antimicrobial activity. Methods: In this study, CTX-PAA was synthesized by the chemical reaction of polyacrylic acid with cefotaxime by N,N'-Dicyclohexylcarbodiimide (DCC) method. Synthetic antibacterial hydrogel films were then prepared with PVA and CTX-PAA for functional application. Results: The increase in the cefotaxime content of the hydrogel films showed a similar decrease in tensile strength and elongation. The values of films impregnated with chemically bonded cefotaxime showed no significant difference. Antibacterial susceptibility was determined against Streptococcus pneumoniae and Escherichia coli using a standardized disc test. Conclusion: The synthetic antibacterial hydrogel films exhibited broad susceptibility against Streptococcus pneumoniae and Escherichia coli. Notably, the antibacterial effect of antibacterial hydrogel films against Grampositive (Streptococcus pneumoniae) was superior to that against Gram-negative (Escherichia coli).

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

Effect of tack cure time on polymerization shrinkage of dual-cure resin cement

  • Choi, Yoorina;Heo, Yu-Keong;Jung, Ji-Hye;Chang, Hoon-Sang
    • International Journal of Oral Biology
    • /
    • 제46권4호
    • /
    • pp.184-189
    • /
    • 2021
  • When luting indirect restorations with dual-cure resin cement (DCRC), excess cement can be easily removed by performing tack cure of DCRC for a few seconds. The purpose of this study was to evaluate whether different tack cure times affect polymerization shrinkage (PS) of the selected DCRC. One dual-cure resin cement (G-CEM LinkAce, GC) was used for measuring PS in light-cure (LC group), self-cure (SC group), and two tack-cure modes. In the first tack-cure subgroup, tack cure was performed for 1, 2, 3, and 5 seconds, followed by light cure after 2 minutes of remnant removal time in each case (TC-LC groups). In the other tack-cure subgroup, tack cure was performed for the same lengths of time, but followed by self-cure in each case (TC-SC groups). PS was measured by a modified bonded disc method for 1,800 seconds. One-way analysis of variance followed by Duncan's post hoc test was used to determine any statistically significant differences among the test groups (α = 0.05). When the DCRC was self-cured after tack cure, PS was significantly lower than when it was only self-cured (p < 0.05); however, tack cure time did not affect PS (p > 0.05). When the DCRC was light-cured, PS was not affected by tack cure or tack cure time (p > 0.05). Therefore, tack cure within 5 seconds did not negatively affect the final PS when the DCRC was light-cured after cement remnant removal.