• Title/Summary/Keyword: Boiler Tubes

Search Result 81, Processing Time 0.024 seconds

A Study on Heat Trasfer Characteristics of Smooth and Ribbed Tubes for Boiler (보일러용 裸管 및 리브붙이管 의 熱傳達 特性 에 관한 硏究)

  • 김종보;한승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.699-705
    • /
    • 1985
  • Heat transfer characteristics in terms of the tube wall-temperature and the enthalpy have been investigated utilizing ribbed (rifled) tubes in order to enhance heat transfer performance. Considerations were given for the cases of smooth tubes in order to compare with the case of ribbed tubes. The tilt angle of the experimental tubes are from 0.deg. to 90.deg. , in order to simulate the boiler water tubes having 15.deg.-90.deg. inclined angle in boiler nose and studded tubes (burner zones), Natural convection and forced convection (Re=1810) conditions were considered in the experiments. The experimental results for the effect for the tube inclination through a natural convection and forced convection are presented and it is shown that ribbed tubes permit an appreciable increase in heat transfer coefficients and consequently it means substantial reductions in boiler water wall tubes and heat exchanger surface areas.

The Evaluation of Mechanical Property of X20CrMoV12.1 Boiler Tube Steels (X20CrMoV12.1강의 열화에 따른 기계적특성 평가)

  • Kim, B.S.;Lee, S.H.;Kim, D.S.;Jung, N.G.
    • Journal of Power System Engineering
    • /
    • v.8 no.3
    • /
    • pp.18-22
    • /
    • 2004
  • Boiler is one of the most important utilities providing steam to turbine in order to supply mechanical energy in thermal power plant. It is composed of thousands of tubes for high efficient heat transfer. The material for boiler tubes is used in such high temperature and pressure condition as $540^{\circ}C$, 22MPa. The boiler tube material is required to resist creep damage, fatigue cracking, and corrosion damages. 2.25%Cr-1Mo steel is used for conventional boiler tubes, and austenitenite stainless steel is used for higher temperature boiler tubes. But the temperature and pressure of steam in power plant became higher for high plant efficiency. So, the property of boiler tube material must be upgaded to fit the plant property. Several boiler tube material was developed to fit such conditions. X20CrMoV12.1 steel is also developed in 1980's and used for superheater and reheater tubes in supercritical boilers. The material has martensite microstructures which is difficult to evaluate the degradation. In this thesis, degrade the X20CrMoV12.1 steel at high temperatures in electric furnace, and evaluate hardness with Vickers hardness tester and strengths with Indentation tester.

  • PDF

Failure Analysis of Waterwall Tubes in Super Critical Boiler (초임계압 보일러 수냉벽 튜브의 파열사고 분석)

  • Kim, B.S.;Jung, N.G.;Kim, D.S.;Lee, S.H.
    • Journal of Power System Engineering
    • /
    • v.7 no.1
    • /
    • pp.20-24
    • /
    • 2003
  • Boiler is one of the most important utilities providing steam to turbine in order to supply mechanical energy in thermal power plant. It is composed of thousands of tubes for high efficient heat transfer. Water is converted to steam inside the waterwall tubes. Many chemical components dissolved in boiler water come out of itself, deposit to the tube wall surface, prohibit heat transer, raise tube metal temperature, eventually fail the boiler tubes. Several tasks such as fracture surface study, tensile test, hardness test, metallurgical test, composition analysis of sticking elements were conducted to identify the root cause of tube failure.

  • PDF

Analysis of Density Wave Oscillation in Boiler Furnace Wall Tubes with Parallel Channel Modeling (평행관 모델링을 통한 보일러 화로벽관 내 밀도파 불안정의 해석)

  • Kim, Jinil;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • A numerical model was developed to predict the density wave oscillation (DWO) in the furnace wall tubes of a fossil-fired once-through boiler. The transient flow fields in the tubes were obtained using a 1D finite volume method in the time domain. A header model was also implemented to simulate the parallel tube connection of the wall tubes. The inlet and outlet mass flow variation in one of the parallel tubes was examined after a heat perturbation to find the DWO. After successful verification with experimental results reported in literature, the developed model was applied to the wall tubes of a 700-MW boiler furnace. In contrast to the simulation of Takitani's experiment, in which the unstable power thresholds tended to rise in the reduced bypass channel flow, no remarkable changes were observed in the power thresholds in the parallel channel modeling of the wall tubes of the boiler furnace.

Structural Analysis of Boiler Module for Sea-Transportation (해상 운송을 위한 보일러 모듈의 구조 해석)

  • Jeon, Y.C.;Kim, T.W.;Jeong, D.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.788-793
    • /
    • 2001
  • Finite element analysis was carried out to investigate the integrity and reliability of boiler module during sea transportation. The boiler module was supported by steel structure to relieve the instantaneous shock from oceanic wave and its primary parts were strengthened with several reinforcements. Finned tube walls which were used in the furnace wall were assumed as orthotropic plates having equivalent material properties. The bank tubes were also equivalently modeled in accordance with ASME B31.1 for the convenience of finite element modeling. The calculation results were compared with the yield stress of the material. In particular, the bank tube stress, which was evaluated by converting the calculated stresses in equivalent tubes into those in original tubes by using the ratio of diameter, was also examined with yield stress.

  • PDF

Design Evaluation of Heavy Duty Heat Exchangers for Compact Steam Boilers (밀집형 증기보일러의 고부하 열교환기 설계평가)

  • Kim, Sungil;Yang, Jongin;Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.2
    • /
    • pp.23-31
    • /
    • 2013
  • Compact steam boiler is a useful heat exchanger in a space-intensive system. There are some constraints in terms of sizing and designing the space confined in the system which is usually used in vessels. In this study, design considerations for heavy duty heat exchangers of compact steam boilers are presented and evaluated. Especially, evaporator tubes of marine boiler which are exposed to a high temperature environment are considered. Also, extended surface designs with a high temperature are examined. In order to determine the criteria with considerations of both heat transfer rate and pressure drop in the heat exchanger, they are evaluated with major variables, such as the tube diameter, the number of tubes, and the tube length. Finally, the design parameters are estimated as the bare tubes are installed instead of the finned tubes.

A Study on the Degradation Evaluation of X20CrMoV12.1 Steel (X20CrMoV12.1강의 열화평가에 관한 연구)

  • Lee, S.H.;Kim, T.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.58-64
    • /
    • 2012
  • Power plant boiler is one of the most important utilities providing steam to turbine in thermal power plant. It is composed of thousands of boiler tubes for high efficient heat transfer. Boiler tube material is used in such high temperature and pressure as $540^{\circ}C$, $170kg/mm^2$. The boiler tube material is needed to resist corrosion damage, creep damage and fatigue damage. 2.25%Cr-1Mo steel is used for conventional boiler tubes. In these days steam temperature and pressure of the power plant became higher for high plant efficiency. So, the material property of boiler tube must be upgraded to meet the plant property. Several boiler tube material was developed to meet such condition. X20CrMoV12.1 steel is also developed in early 1980's and used for superheater and reheater tubes in supercritical boilers. The material has martensitic structure, which is difficult to evaluate the material degradation. Boiler tube material at severe condition was tested to evaluate long term and short term degradation and creep. Through long term and high temperature degradation test, lath structure was decreased and recrystallization has been proceeded by sub-crystal. And in this research the effect of temperature and stress on boiler tube characteristic,for example, deformation by creep was changed rapidly at relatively high temperature and stress because creep was affected easily by temperature and stress.

Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission (음향방출을 이용한 보일러튜브 누설평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.45-51
    • /
    • 2004
  • Boiler tubes in power plants are often leaked due to various material degradations including creep and thermal fatigue damage under severe operating conditions such as high temperature and high pressure over an extended period of time. To monitor and diagnose the tubes on site and in real time, the acoustic emission (AE) technology was applied. We developed an AE leak detection system, and used it to study the variation of AE signal from the on-site tubes in response to the changes in the boiler operation condition and to detect the locations of leakage based on it. Detection of leak was performed by acquiring and evaluating the signals in separate regimes of high and low frequency signal. As a result of these studies, we found that on-line monitoring and detection of leak location for boiler tubes is possible using the developed system. Thus, the system is expected to contribute to the safe operation of power plants, and prevent economic losses due to potential leak.

Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results - (멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 -)

  • Kim, Jong-Jin;Sung, Choi-Kyu;Ki, Ho-Choong;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF

Study of Boiler Tube Micro Crack Detection Ability by Metal Magnetic Memory (금속 자기기억법 활용 보일러 튜브의 미소 결함 검출력 연구)

  • Jungseok, Seo;Joohong, Myong;Jiye, Bang;Gyejo, Jung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.93-96
    • /
    • 2022
  • The boiler tubes of thermal power plants are exposed to harsh environment of high temperature and high pressure, and the deterioration state of materials rapidly increases. In particular, parent material and welds of the materials used are subjected to a temperature change and various constraints, resulting in deformation and its growth, resulting in frequent leakage accidents caused by tube failure. The power plant checks the integrity of boiler tubes through non-destructive testing as it may act as huge costs loss and limitation of power supply during power station shutdown period due to boiler tube leakage. However, the current non-destructive testing is extremely limited in the field to detect micro cracks. In this study, the ability of metal magnetic memory technique to detect flaws of size that are difficult to inspect by the visual or general non-destructive methods was verified in the early stage of their occurrence.