Application of a Large Scale Heat Pipe System to Preheating the Fuel Gas of Low Heating Value (분리형 히트파이프의 저발열량 연료가스 예열시스템에 대한 적용연구)

  • Park, Heung Soo;Riu, Kap Jong;Lee, Jin Ho;Lee, Yong Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1085-1097
    • /
    • 1999
  • A separate heat pipe system capacity of 3,700kW has been developed and applied to preheating the blast furnace gas for recovery of the waste heat from boiler. The system is designed to preheat the blast furnace gas up to $126^{\circ}C$ by using tho boiler exhaust gas of which temperature is $180^{\circ}C{\sim}220^{\circ}C$. The arrangement of the fin tubes as well as the shape of the fin has been carefully determined to minimize the fouling problems. The heat pipe system was found to be stable in circulation of the working fluid and the range of the temperature variation of the preheated blast furnace gas was within $10^{\circ}C$. It was proved through a long-term test that the selected tube arrangement and the shape of the fins are proper to prevent the fouling problems and that the pay-back period of the system Is within one year.

Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment (공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF

Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler (자트로파 유(Crude Jatropha Oil)에 대한 보일러 직접 연소 특성)

  • Kang, Sae-Byul;Kim, Jong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2934-2939
    • /
    • 2008
  • We conducted a test of a direct burning of crude Jatropha oil (CJO) in a commercial boiler system. The fuel, crude Jatropha oil is not biodiesel which comes from transeterification process of bio oil, but it is pure plant oil. The higher heating value (HHV) of the CJO is 39.3 MJ/kg (9,380 kcal/kg) and is higher than that of a commercial heating oil, 37.9 MJ/kg. The kinematic viscosity of CJO is 36.2 mm2/s at $40^{\circ}C$ and 8.0 mm2/s at $100^{\circ}C$. The burner used in the test is a commercial burner for a commercial heatingoil and its capacity is 140 kW (120,000 kcal/h). We did a preliminary test whether the combustion is stable or not. The preliminary test was a kind of open air combustion test using the commercial burner with crude Jatropha oil. We found that the combustion can be stable if the crude Jatrophaoil temperature is higher than $90^{\circ}C$. We measured the flue gas concentration by using a gas analyzer. The NOx concentration is $80{\sim}100\;ppm$ and CO concentration is nearly 0 ppm at flue gas O2 concentration of 3.0 and 4.5%.

  • PDF

High-temperature Mechanical Properties Measurement and Life Assessment of Boiler Equipment by Instrumented Indentation Technique (계장화 압입시험법을 이용한 보일러 설비의 고온 기계적 물성 측정과 수명 평가)

  • Ro, Dong-Seong;Hong, Jeong-Wha;Kim, Kwang-Ho;Lee, Jung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • Recently power plants and oil refineries are focusing on capacity enlargement for better efficiency through higher temperature and higher pressure. Thickness of boiler tubes becomes lessened due to oxidation and erasion caused by high temperature bums gas flowing over tubes outside. Accordingly, mechanical stress of tubes is increasing and that is a critical factor to make a crack and fracture. To prevent those sorts of accidents, aging assessment for proper periodic repair and replacement should be conducted reliably and reasonably. We performed IIT test on Cr-Mo steel, one of the most heat-resistant materials for facilities in power plants, and we report the test result and the considerable effectiveness of IIT test.

Apparatus for Measuring Fan Stall of Boiler for Power Station (화력발전용 보일러의 맥동 측정 장치)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1681-1684
    • /
    • 2014
  • In this paper, in the ventilation system of coal-fired power boilers can measure in real time the fan stall mechanism is all about. The fan stall guard system of boiler airing system of the class of 500MW capacity to protect fan. But because confidence is loosed and operation is influenced by frequent fault of fan stall guard system, confidence is improved by substituting DCS Logic for it.

Design Impact evaluation through CFB Boiler Design Parameter and Lower Furnace Fraction of Combustion Heat (순환 유동상 연소로 설계 인자 및 하부 연소율에 따른 설계 영향 평가)

  • Yang, Jongin;Kim, Taehyun;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.41-42
    • /
    • 2012
  • Circulating fludized bed(CFB) furnace which can use a variety of low-grade fuels because of high heat capacity and good mixing characteristic in its furnace have turned out to be effective system. There is no many research to design CFB boiler in korea. thus, we feel necessity to research design method. So far accurate hydrodynamics and combustion mechanism information in CFB furnace has been lacked. Therefore, design method that derives design parameter is being made. so, this study is aimed to derive design parameters of CFB furnace from heat and mass balance by using existing plant data.

  • PDF

A comparison of steam turbine control systems according to adoption of turbine bypass system (바이패스 시스템 체용 유무에 따른 증기 터빈제어 비교)

  • Choi, I.K.;Kim, J.A.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2342-2344
    • /
    • 2000
  • Many years ago, most of thermal power plants built in this country were of subcritical pressure, of medium or small size, of constant pressure operation, of drum type steam generator. But, nowadays, almost all of them were of high efficiency, of supercritical pressure, of great capacity(about 500MW), of sliding pressure operation, of once through type steam generator. Presently built once through boiler introduces turbine bypass systems to variable pressure operation which eliminates unexpected materials in boiler tube during startup, minimizes fuel loss by short startup period, eventually improves total efficiency and power system stability

  • PDF

Pellet Made of Agricultural By-product and Agricultural Pellet Boiler System (농림부산물 원료 펠릿 및 농업용 펠릿 난방기)

  • Kang, Y.K.;Ryou, Y.S.;Kcang, G.C.;Kim, J.G.;Kim, Y.H.;Jang, J.K.;Lee, H.M.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.252.2-252.2
    • /
    • 2010
  • Biomass is considered to be a major potential fuel and renewable resource for the future. In fact, there is high potential to produce the large amount of energy from biomass around the world. In this study, to obtain basic data for practical application of wood pellet and wood pellet boiler system as heating system in agriculture, agricultural biomass resources were surveyed, pellet was made of agricultural by-product such as stem of rape, oat and rice, ricehusk and sawdust and wood pellet boiler system with capacity of 116 kW was manufactured and installed in greenhouse of $38.5m{\times}32m$. High heating value, bulk density and ash content of pellet made of agricultural by-product and efficiency and heating performance of this system was estimated. Rice straw was the largest agricultural biomass in 2005 and the total amount of rice straw converted into energy of $131.71{\times}10^{11}$ kJ. And in 2005, total amount of forest' by-product converted into energy of $29,277.05{\times}10^{11}$ kJ. High heating values of pellets made of agricultural by-products of stem and seed of rape, stem of oat, rice straw and rice husk were 16,034, 16,026, 16,089, 15,650, 15,044 kJ/kg respectively. High heating values of pellets made of agricultural by-products were 83.6% compared to that of wood pellet. Average bulk density of pellets made of agricultural by-products of stem and seed of rape, stem of oat, rice straw and rice husk was 1,400 $kg/m^3$. Ash contents of the pellets were 6.6, 7.0, 6.2, 5.5, 33% respectively. Ash content of rice husk pellet was the largest compared to other kind of pellets. To increase efficiency of agricultural pellet boiler, the boiler adopted secondary heat exchanger. The agricultural pellet boiler designed and manufactured in this study had high efficiency of 84.2% compared to the conventional agricultural pellet boiler, when water flow rate, exhaust gas temperature and average combustion furnace temperature were 39L/min, $180^{\circ}C$, $680^{\circ}C$ respectively. And pellet supplying and pausing time were 13, 43 seconds respectively. In March of 2010, prices of wood pellet, agricultural tax free diesel, diesel, kerosene were 350 won/kg, 811 won/L, 1,422 won/L, 976 Won/L respectively. Also in terms of energy, prices per same heating value were 77.8, 90.1, 158, 108.4 Won/Mcal. Energy saving rate of wood pellet was 16, 50, 39% compared to agricultural tax free diesel, diesel and kerosene respectively.

  • PDF

Numerical Simulation on the Effects of Air Staging for Pulverized Coal Combustion in a Tangential-firing Boiler (접선연소식 보일러에서 미분탄 연소 시 공기 배분의 영향에 대한 전산해석연구)

  • Kang, Kieseop;Ryu, Changkook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.4
    • /
    • pp.548-555
    • /
    • 2017
  • This study investigated the influence of air staging on combustion and NOx emission in a tangential-firing boiler at a 560 MWe capacity. For air staging, the stoichiometric ratio (SR) for the burner zone was varied from 0.995 to 0.94 while the overall value was fixed at 1.2. The temperature and heat flux in the burner zone and upper furnace corresponded to the distribution of SR, while the total boiler efficiency remained similar. The NOx emission at the furnace exit was reduced by up to 20% when the SR in the burner zone decreased to 0.94. However, the amount of unburned carbon and slagging propensity was not noticeably influenced by the changes in the SR of the burner zone. Therefore, it was favorable to lower the SR of the burner zone for reduction of NOx emission.

Performance Analysis of a Heat Pump Using Refrigerant Mixtures (II) (혼합냉매를 사용한 열펌프의 성능해석 (II))

  • Kim, M.S.;Kim, T.S.;Won, S.P.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.218-225
    • /
    • 1990
  • Studies on the performance of a heat pump using non-azeotropic refrigerant mixtures are done. In order to estimate the thermodynamic properties for the selected non-azeotropic refrigerant mixtures including R22/R152a, R22/R142b, R22/R114 and R13B1/R152a, Peng-Robinson equation of state is adopted. The pressure-enthalpy diagram and the temperature-entropy diagram are plotted for each refrigerant mixture. Considerations on the capacity modulation for the heat pump system using refrigerant mixtures are taken into. Results show that when the heating load varies, the possibility for the capacity modulation is found in the heat pump system using a compressor with constant volume flow rate. Under a constant heating capacity condition in the heat pump system, the coefficient of performance increases when the refrigerant mixtures are used. The volume flow rate decreases as the mass fraction of lower boiler increases in this case.

  • PDF