• Title/Summary/Keyword: Boiler

Search Result 2,528, Processing Time 0.037 seconds

Effect of Feeding Aspergillus oryzae Inoculant Food-waste Diets on Performance, $NH_3$ Emission and Fecal Microflora in Broiler Chickens (Aspergilius Oryzae 접종 남은 음식물 사료가 육계의 생산성, $NH_3$ 발생량 및 분내 미생물 성상에 미치는 영향)

  • Hwangbo J.;Hong E. C.;Lee B. S.;Bae H. D.;Kim W.;Nho W. G.;Kim J. H.;Kim I. H.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.4
    • /
    • pp.281-289
    • /
    • 2005
  • This study investigated the effect of dried food-waste diets(FW) fermented by Aspergillus oryzae(AO), on broiler growth performance, $NH_3$, emission and fecal microflora. Three hundreds broilers, two week old Hubbard strain, were randomly allotted to 4 experiments and fed with standards early boiler diet replaced with FW and AFW. In experiment 1, eighty four broilers were distributed into 7 treatments with 4 pens at 3 birds per replicate(pen). The dietary treatments ; T1 was com-soy bean meal based broiler diet(Control), T2, T3, T4 were for basal diet replaced with dried food waste without AO(FW) at the level of 20, 40 and $60\%$, respectively and T5, T6 and T7 followed the same levels for the basal diet but using Aspergillus oryzae inoculate food-waste(AFW). For experiments 2, 3, 4, seventy two broilers were distributed into 6 treatments with 4 pens at 3 birds per replicate(pen), respectively. The dietary treatments were the com-soy bean meal based broiler diet replacement with different combinations of FW and AFW, 1:0, 3:1, 1:1, 1:3, 0:1. at level of 20, 40 and $60\%$, respectively. In Exp. 1, it tended to be decreased in weight gain, however, there were no statistical differences among treatments except FW $60\%$ level of replacement(p<0.05). Feed intake and feed efficiency was not different among treatments. Total bacterial counts were not different between the control and FW diet, but E. coli decreased as the AFW levels of replacement were increased(p<0.05). There were no differences in weight gain, feed intake and feed efficiency among treatments in Exp. 2 and weight gains were lower fur FW diet compared with the control and AFW diet in Exp. 3(p<0.05). In Exp. 4, there were no differences in feed intakes among treatments, but lower in weight gain and feed efficiency in FW diet than that the control. In experiment 3, the $NH_3$ emission was the highest among treatments in FW/AFW 1:0 diet(p<0.05). From these results, it seems that FW would be supplemented up to $20\%$ in broiler diets and AO culture extract could improve FW value as feed supplements.

Effects of Repeated High Ambient Temperature on Performance in Broilers Heat-Conditioned at an Early Age (반복적인 고온환경이 사전고온 적응한 육계의 생산성에 미치는 영향)

  • Hwangbo, Jong;Yang, Young-Rok;Yoon, HyungSook;Kim, Jimin;Park, Byungsung;Choi, Hee Chul;Choi, Yang-Ho
    • Korean Journal of Poultry Science
    • /
    • v.42 no.3
    • /
    • pp.257-265
    • /
    • 2015
  • Heat conditioning at an early age has been known to help chickens cope with heat stress later in life. The present study was conducted to determine the effects of heat conditioning at 5 days of age in broilers repeatedly exposed to high ambient temperature later in life. A total of 256 day-old Arbor Acre boiler chicks were housed in two identical rooms with a 23-h light/1-h dark cycle and provided with feed and water ad libitum. At 5 days of age, the birds in one room were exposed to $37^{\circ}C$ for 24 hours, while those in the other room served as controls. On day 21, half of the birds in each room were moved into the other room so that each room contained both control and heat-conditioned birds. After a 7-day adaptation period, the birds in one room were exposed to high ambient temperature ($21^{\circ}C{\rightarrow}31^{\circ}C$) for 3 days, whereas those in the other room were kept at normal temperature. The same 3-day exposure to high ambient temperature was repeated two weeks later. Hence, there were four treatment groups (CON+CON: control+control; CON+HS: control+high ambient temperature; HC+CON: heat conditioning+control; and HC+HS: heat conditioning+high ambient temperature). Repeated heat stress resulted in decreased feed intake, water intake, body weight gain, and spleen weight (p<0.05) and increased rectal temperature (p<0.05), mortality, and plasma corticosterone concentrations. The relative weight of the spleen was increased in the heat-conditioned group (p<0.05). Plasma biochemicals were also influenced by high temperature. Thus, no beneficial effects of heat conditioning at an early age were detected in broilers repeatedly exposed to high ambient temperature later in life.

Study on the Perceptions and Purchasing Realities of Consumers for Onion Hot-Water Extracts (양파열수추출물에 대한 소비실태 조사)

  • Kim, Su-Ryeom;Kim, Chang-Soon;Oh, Hyeon-Ju
    • Korean journal of food and cookery science
    • /
    • v.25 no.4
    • /
    • pp.395-405
    • /
    • 2009
  • In this study, a survey was conducted to determine consumer perceptions and satisfaction for onion hot-water extracts. Among the study subjects, females (53.3%) were in greater number than males, and individuals in their 40s (35.1%) made up the largest group. Cocerning the detailed efficacy of onion hot-water extracts, most respondents (84.5%) were aware of their efficacy and females recognized this more than males (p<0.001). Most consumers (67.3%) purchased onion hot-water extracts from 'health food stores prepared using a double boiler', and many consumers (47.4%) received information on the extracts from families and relatives. Of the respondents, 51.8% said they purchased 'quantities for $1{\sim}3$ months' at one time, and 33.1% stated that the price of onion hot-water extracts was expensive. They considered 'health' the most important aspect when purchasing, and preferred 'pouch packs' (60.3%) and considered 'easiness to open convenience to drink, and safety' (42.0%) the most important product features. Also, 62.8% of the respondents consumed onion hot-water extracts, and many drank them $1{\sim}3$ times a week, with '70 mL' as one dose, and drank them 'regardless of time'. The consumers were satisfied with the listing of health effects, but were not satisfied with the 'taste', 'smell', or 'color' of products. Concerning advertisements for the efficacy of onion hot-water extracts, 72.5% replied 'I trust them a little'. And concerning the expanding onion hot-water extract market, many respondents said it is difficult to choose an onion hot-water extract due to many similar products at the market. They also requested improvements of taste and flavor.

Optimization Process Models of Gas Combined Cycle CHP Using Renewable Energy Hybrid System in Industrial Complex (산업단지 내 CHP Hybrid System 최적화 모델에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.65-79
    • /
    • 2019
  • The study attempted to estimate the optimal facility capacity by combining renewable energy sources that can be connected with gas CHP in industrial complexes. In particular, we reviewed industrial complexes subject to energy use plan from 2013 to 2016. Although the regional designation was excluded, Sejong industrial complex, which has a fuel usage of 38 thousand TOE annually and a high heat density of $92.6Gcal/km^2{\cdot}h$, was selected for research. And we analyzed the optimal operation model of CHP Hybrid System linking fuel cell and photovoltaic power generation using HOMER Pro, a renewable energy hybrid system economic analysis program. In addition, in order to improve the reliability of the research by analyzing not only the heat demand but also the heat demand patterns for the dominant sectors in the thermal energy, the main supply energy source of CHP, the economic benefits were added to compare the relative benefits. As a result, the total indirect heat demand of Sejong industrial complex under construction was 378,282 Gcal per year, of which paper industry accounted for 77.7%, which is 293,754 Gcal per year. For the entire industrial complex indirect heat demand, a single CHP has an optimal capacity of 30,000 kW. In this case, CHP shares 275,707 Gcal and 72.8% of heat production, while peak load boiler PLB shares 103,240 Gcal and 27.2%. In the CHP, fuel cell, and photovoltaic combinations, the optimum capacity is 30,000 kW, 5,000 kW, and 1,980 kW, respectively. At this time, CHP shared 275,940 Gcal, 72.8%, fuel cell 12,390 Gcal, 3.3%, and PLB 90,620 Gcal, 23.9%. The CHP capacity was not reduced because an uneconomical alternative was found that required excessive operation of the PLB for insufficient heat production resulting from the CHP capacity reduction. On the other hand, in terms of indirect heat demand for the paper industry, which is the dominant industry, the optimal capacity of CHP, fuel cell, and photovoltaic combination is 25,000 kW, 5,000 kW, and 2,000 kW. The heat production was analyzed to be CHP 225,053 Gcal, 76.5%, fuel cell 11,215 Gcal, 3.8%, PLB 58,012 Gcal, 19.7%. However, the economic analysis results of the current electricity market and gas market confirm that the return on investment is impossible. However, we confirmed that the CHP Hybrid System, which combines CHP, fuel cell, and solar power, can improve management conditions of about KRW 9.3 billion annually for a single CHP system.

Study on the Lubricity Characteristics of Bio-heavy Oil for Power Generation by Various feedstocks (다양한 원료에 따른 발전용 바이오중유의 윤활 특성 연구)

  • Kim, Jae-Kon;Jang, Eun-Jung;Jeon, Cheol-Hwan;Hwang, In-Ha;Na, Byung-Ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.985-994
    • /
    • 2018
  • Bio-heavy oil for power generation is a product made by mixing animal fat, vegetable oil and fatty acid methyl ester or its residues and is being used as steam heavy fuel(B-C) for power generation in Korea. However, if the fuel supply system of the fuel pump, the flow pump, the injector, etc., which is transferred to the boiler of the generator due to the composition of the raw material of the bio-heavy oi, causes abrasive wear, it can cause serious damage. Therefore, this study evaluates the fuel characteristics and lubricity properties of various raw materials of bio-heavy oil for power generation, and suggests fuel composition of biofuel for power generation to reduce frictional wear of generator. The average value of lubricity (HFRR abrasion) for bio-heavy oil feedstocks for power generation is $137{\mu}m$, and it varies from $60{\mu}m$ to $214{\mu}m$ depending on the raw materials. The order of lubricity is Oleo pitch> BD pitch> CNSL> Animal fat> RBDPO> PAO> Dark oil> Food waste oil. The average lubricity for the five bio-heavy oil samples is $151{\mu}m$ and the distribution is $101{\mu}m$ to $185{\mu}m$. The order of lubricity is Fuel 1> Fuel 3> Fuel 4> Fuel 2> Fuel 5. Bio-heavy oil samples (average $151{\mu}m$) show lower lubricity than heavy oil C ($128{\mu}m$). It is believed that bio-heavy oil for power generation is composed of fatty acid material, which is lower in paraffin and aromatics content than heavy oil(B-C) and has a low viscosity and high acid value, resulting in inhibition of the formation of lubricating film by acidic component. Therefore, in order to reduce friction and abrasion, it is expected to increase the lubrication of fuel when it contains more than 60% Oleo pitch and BD pitch as raw materials of bio-heavy oil for power generation.

Experimental Study on the Agglomeration Characteristics of Coal and Silica Sand by addition of KOH (KOH 첨가에 의한 석탄 및 유동사의 응집특성에 대한 실험적 연구)

  • Cho, Cheonhyeon;Gil, Eunji;Lee, Uendo;Lee, Yongwoon;Kim, Seongil;Yang, Won;Moon, Jihwan;Ahn, Seokgi;Jung, Sungmook;Jeong, Soohwa
    • Clean Technology
    • /
    • v.28 no.1
    • /
    • pp.46-53
    • /
    • 2022
  • The agglomeration characteristics of coal and silica sand were investigated under various conditions using mixed samples consisting of coal, silica sand, and potassium hydroxide, which is an agglomeration accelerator. The samples were prepared by either physically mixing or using aqueous solutions. The experiments using the physically mixed powder samples were performed with a two hour reaction time. The results showed that the number of aggregates generated increased as the reaction temperature and the total potassium content increased. The experiments using aqueous solutions were performed at 880 ℃, which is the operating temperature of a fluidized bed boiler, and at 980 ℃, which assumes a local hot spot. The amount of agglomeration generated as the reaction time increased and the total potassium content increased was identified. In the experiment performed at 880 ℃, the amount of aggregate generated clearly increased with the reaction time, and in the experiment performed at 980 ℃, assuming a local hot spot, a large amount of aggregate was generated in a relatively short time. The aggregates became harder as the potassium content increased. When the total potassium content was less than 1.37 wt.%, the aggregates were weak at both temperatures and collapsed even with a slight impact. Additionally, the surface characteristics of the silica sand and ash aggregates were observed by SEM-EDS analysis. The analysis revealed a large amount of potassium at the bonding sites. This result indicates that there is a high possibility of aggregation in the form of a eutectic compound when the alkali component is increased.

Analysis of Perception of School Foodservice Facilities and Utilities in Gyeongnam Area by School Nutrition Teachers (Dietitians) -Comparison of School Foodservice Facilities and Improvement of Utilities in Schools- (경남지역 영양(교)사의 급식시설 설비에 대한 인지도 분석 -학교급식시설 현대화 사업 완료 학교와 미완료 학교의 비교를 중심으로-)

  • Jeon, Young;Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.9
    • /
    • pp.1447-1456
    • /
    • 2014
  • The purpose of this study was to compare perception of school foodservice facilities and utilities in dietitians and school nutrition teachers in the Gyeongnam area between schools that improved foodservice facilities and utilities versus those who did not. From July 23 to Aug 31, 2012, 391 questionnaires were distributed, and 289 questionnaires were obtained. A total of 275 questionnaires were used for the final analysis, excluding improper ones. The results of this study were as follows. First, among 275 schools, 90 schools (32.7%) improved school foodservice facilities and utilities while 175 schools (67.3%) did not. Second, schools with improved facilities had a more well-equipped receiving room (P<0.01), preparation room (P<0.001), dishwashing room (P<0.001), storage room for supplies (P<0.001), rest-room for school foodservice employees (P<0.05), locker room (P<0.01), shower room (P<0.001), laundry room (P<0.001), boiler room (P<0.05), and room for serving cart (P<0.05) than schools with no improvement. Third, total perception score of school foodservice facilities area from schools with improved facilities (1.71) was significantly higher than that (1.60) of school without improvement (P<0.001). Fourth, total satisfaction (3.32) of school foodservice facilities and utilities in school with improved facilities was significantly higher than that (2.62) of schools without improvement (P<0.01). Fifth, schools with improved facilities had a better equipped of floor (P<0.05), entrance (P<0.001), drain (P<0.001), water supply (P<0.01), lighting (P<0.001), hand washing (P<0.001), foodservice management room (P<0.001), locker room (P<0.001), rest-room and shower room (P<0.001), and preparation room (P<0.001) than schools without improvement. However, there was no significant difference in terms of walls and ceilings, windows, ventilation, and storage. In conclusion, school foodservice facilities and utilities improvement should conducted as soon as possible.

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF