• Title/Summary/Keyword: Body-temperature monitoring

Search Result 125, Processing Time 0.026 seconds

Flap Monitoring by Infra-red Thermometer (적외선 고막 체온계를 이용한 피판감시)

  • Kirk, Insoo;Hong, Joon-Pio
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.82-85
    • /
    • 2004
  • Flap monitoring is important for flap salvage. Although there are many methods to observe the flap, practical methods mostly used are subjective methods. Recording flap surface temperature is one of the objective methods of flap monitoring. We used an infra-red thermometer to simplify monitoring of the flap temperature. 60 groin flaps of SD rats are used in the experiment. Artificial arterial or venous insufficiency was made and the surface temperature was checked and compared with body temperature. In the results, the temperature of the arterial clamped flaps was lower than that of body and the mean difference was $0.3^{\circ}C$ after 20 minutes of clamping. In the vein-clamped flaps, the mean decrease was $0.4^{\circ}C$ after 30 minutes of clamping. The all difference of the temperature between the flaps and body was statistically significant. Our results suggest that flap monitoring by infra-red thermometer is simple, useful and helpful to evaluate the flap status.

  • PDF

A Study on Body Temperature Measurement of Woven Textile Electrode Using Lock-In-Amp based on Microprocessor (마이크로 프로세서 기반 Lock-In-Amp를 이용한 텍스타일 직물전극의 체온 측정에 관한 연구)

  • Lee, Kang-Hwi;Lee, Sung-Su;Lee, Jeong-Whan;Song, Ha-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1141-1148
    • /
    • 2017
  • Generally, a thermistor made by sintering a metal oxide is widely used to measure the ambient temperature. This thermistor is widely used not only for industrial use but also for medical use because of its excellent sensitivity, durability, temperature change characteristics and low cost. In particular, the normal body temperature is 36.9 degrees relative to the armpit temperature, and it is most closely related to the circulating blood flow. Previous studies have shown that body temperature changes during biomechanical changes and body temperature changes by anomalous signs or illnesses. Therefore, in this study, we propose a Lock-In-Amp design to detect minute temperature changes of clothing and thermistor wired by a preacher as a method to regularly measure body temperature in daily life. Especially, it is designed to measure the minute resistance change of the thermistor according to body temperature change even in a low-cost microprocessor environment by using a micro-processor-based Lock-In-Amp, and a jacquard and the thermistor is arranged so as to be close to the side, so that the reference body temperature can be easily measured. The temperature was measured and stored in real time using short-range wireless communication for non - restraint temperature monitoring. A baby vest was made to verify its performance through temperature experiments for infants. The measurement of infant body temperature through the existing skin sensor or thermometer has limitations in monitoring infant body temperature for a long time without restriction. However, it can be overcome by using the embroidery fabric based micro temperature monitoring wireless monitoring device proposed in this study.

Development and Possibility Evaluation of Thermal Imaging Camera for Medical Monitoring of Body Temperature (열화상카메라 개발을 통한 의료용 체열진단 가능성 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2015
  • Recently, thermography camera have been using for body-temperature monitoring. We report on fabrication of prototype thermography camera using the chalcogenide-glass lens and the camera test by analysis of thermal image. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ with noise equivalent temperature difference(NETD) of 87.7mK. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

Development for body temperature sensor and monitoring telemetry system (체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현)

  • Lee, Jyung-Hyun;Seong, Ki-Woong;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

Analysis of temperature monitoring data for leakage detection of earth dam (흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Seo, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body (댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구)

  • Oh, Seok-Hoon;Kim, Jung-Yul;Park, Han-Gyu;Kim, Hyoung-Soo;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Development of Economical Mobile Patient Monitoring Systems (경제적인 모바일 환자 모니터링 시스템의 개발)

  • 김창영;배재학
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.667-669
    • /
    • 2004
  • 본 논문에서는 경제성, 효율성, 확장성 및 개발의 편의성을 고려한 환자 모니터링 모바일 시스템의 개발 사례를 보고한다. 특히 생명징후(Vital Sign) 중에서도 체온(Body Temperature)을 모니터링 하는 모바일 시스템 MBTMS 개발을 다루었다. MBTMS(Mobile Body Temperature Monitoring System)는 다음과 같이 세 부분으로 구성된다: (1) 환자의 체온들 수집하기 위한 센서, (2) 센서를 통해 체온을 측정하는 모듈, (3) 모듈에서 전달받은 자료를 처리 분석, 저장하는 PC(Personal Computer) Application으로 구성된다. 이러한 MBTMS는 입원환자 및 노약자를 위한 경제적인 PMS(Patient Monitoring System) 개발 및 e-Health 연구의 한 부분으로 활용될 수 있을 것이다.

  • PDF

Temperature Detection and Monitoring System of Livestock Through Ear-Tag Based on IoT (IoT 기반의 이표를 통한 가축 온도 변화 감지 및 모니터링 시스템)

  • Park, Young-Soo;Park, Kyoung-Yong;Kim, Min-Sun;Park, Jun-Kyu;Kwon, Seong-Geun
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.3
    • /
    • pp.474-481
    • /
    • 2017
  • In Korea, foot-and-mouth disease has not been reported for several decades, but it began to develop again in 2000. For 2010~2011, when the worst occurred, 3.5 million animals were disposed of resulting in a loss of 2.8 trillion won. In order to prevent the harmful effects of foot-and-mouth disease, vaccination and housing management are being implemented. Despite these measures, foot-and-mouth disease is infected with air through the respiratory tract and accompanies fever after latency. Therefore, it is recognized that measuring and managing the body temperature of livestock at the early stage is the first step of managing this disease. In this paper, we propose a temperature monitoring system that can measure the body temperature by incorporating temperature sensor mounted in ear-tag of cattle and collect body temperature data of each individual cattle through BLE into the control server. The proposed body temperature monitoring system has various advantages such as easy installation without the help of livestock specialists and not damaging the organs of the livestock. So, it is possible to manage the abnormal symptom of cattle in real time and it is believed that the proposed monitoring system will revolutionize the prevention of foot-and-mouth disease.

Circadian Biorhythmicity in Normal Pressure Hydrocephalus - A Case Series Report

  • Herbowski, Leszek
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.151-160
    • /
    • 2022
  • Continuous monitoring of intracranial pressure is a well established medical procedure. Still, little is known about long-term behavior of intracranial pressure in normal pressure hydrocephalus. The present study is designed to evaluate periodicity of intracranial pressure over long-time scales using intraventricular pressure monitoring in patients with normal pressure hydrocephalus. In addition, the circadian and diurnal patterns of blood pressure and body temperature in those patients are studied. Four patients, selected with "probable" normal pressure hydrocephalus, were monitored for several dozen hours. Intracranial pressure, blood pressure, and body temperature were recorded hourly. Autocorrelation functions were calculated and cross-correlation analysis were carried out to study all the time-series data. Autocorrelation results show that intracranial pressure, blood pressure, and body temperature values follow bimodal (positive and negative) curves over a day. The cross-correlation functions demonstrate causal relationships between intracranial pressure, blood pressure, and body temperature. The results show that long-term fluctuations in intracranial pressure exhibit cyclical patterns with periods of about 24 hours. Continuous intracranial pressure recording in "probable" normal pressure hydrocephalus patients reveals circadian fluctuations not related to the day and night cycle. These fluctuations are causally related to changes in blood pressure and body temperature. The present study reveals the complete loss of the diurnal blood pressure and body temperature rhythmicities in patients with "probable" normal pressure hydrocephalus.

A study on WSN based ECG and body temperature measuring system for ubiquitous healthcare: 2. Vital signal monitoring software system (유비쿼터스 헬스케어를 위한 센서 네트워크 기반의 심전도 및 체온 측정 시스템: 2. 생체신호 모니터링 소프트웨어 시스템)

  • Lee, Dae-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.417-424
    • /
    • 2006
  • An ubiquitous healthcare monitoring system for elderly person at home was designed for continuous healthy monitoring of elderly person or patients. Human vital signals, such as ECG and body temperature, were monitored by terminal PC or PDA via ECG and temperature sensor nodes on the patient's body. From the ECG data, the heart rate, tachycardia, bradycardia and arrhythmia were diagnosed on the terminal PC or PDA to assist doctor's or nurse's aid or patient itself to monitor the patient's condition and give medical examination. Artificial judgement support system was designed in server computer and the system support a doctor or nurser for management or treatment of the patient. This system can be applied to vital signal monitoring system for solitude elderly person at self house or home health care service part. And this ubiquitous healthcare system can reduce the medical expenses in coming aging or aged society.