• 제목/요약/키워드: Body surface scan

검색결과 70건 처리시간 0.024초

3D 스캔데이터를 활용한 동작에 따른 하반신 주요 부위별 체표면 변화 및 상관관계 - 20-24세 여성을 중심으로 - (Identification of the Relationship between Surface Variations of Lower Body Parts by Movement Using 3D Scan Data - A Focus on Women Aged 20 to 24 Years -)

  • 이소영;김지민
    • 복식
    • /
    • 제67권3호
    • /
    • pp.81-98
    • /
    • 2017
  • The purpose of this study is to provide basic information for the development of pants patterns with a high level of fit and comfort through calculating surface variations of lower body parts by movement, grouping them into factors, and analyzing how their surface variations link to one another. The achieved results will help determine essential elements for constructing pants patterns, such as key measurements of lower body parts, the amount of ease values and selection of fabrics, which should be taken into consideration for allowing better movement in clothing. The study required lower body 3D scanning of women for analysis, and 13 women between the ages of 20-24 participated in the scanning, which was done by using Artec Eva 3D scanner. Their scanned data were digitalized and converted to measure the values of their lower body surface length and girth in pre-determined positions such as walking, stair climbing and sitting on a chair. These measurements have been statistically analyzed through SPSS 21.0 to obtain the average amounts and rates of extension for each of the measurement item. Some of the highlighted study results are as follows: The surface length and girth measurements were grouped into 4 factors based on their average extension rates. The results from correlation analysis between measurement items within each factor demonstrated that common items linked to all the changes in the values of other items in the three movements. But in most cases, items were not always correlated with each other for different movements. The results also showed that there were correlations between girth measurements, length measurements, and girth and length measurements. Therefore, key measurements for daily pants should be determined within reasonable estimations between relevant measurement items, while the measurements for work pants, which often withstand certain postures or repetitive movements, may require measurement items that are appro priate for, and closely related to, certain movements or tasks.

3D Scanner를 이용한 foundation 착용시의 인체 변화 계측 (Body Shape Variations Measurements with 3D Scanner for Wearing Foundation)

  • 박지은;김희은
    • 한국의류산업학회지
    • /
    • 제9권6호
    • /
    • pp.651-657
    • /
    • 2007
  • This study was carried out to analyse body configuration and to observe any space between skin and foundation. A special 3D scanner was used to analyze this foundation. Experimental foundations were brassiere, girdle, and all-in-one. Four subjects volunteered, each subject was scanned while wearing foundation and not wearing foundation. Body shape variations were analyzed with an Auto CAD and ScanWax program which analyzes cross section of the skin surface to look for any changes. Height was increased all parts of body, circumference was increased in breast and bust while wearing the foundation. The hip thickness was not increased with wearing the foundation. Therefore this foundation makes people have a different appearance due to unexpected body shape variations. The effects of this foundation should be classified by observing height, circumference, and thickness changes in the body.

B-Spline Surface를 이용한 인체 계측 데이터의 Interpolation과 Parametrization (Interpolation and Parametrization of Human Body Scan Data Using B-Spline Surface)

  • 설인환;강태진
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.235-238
    • /
    • 2002
  • 3차원 어패럴 캐드 시스템은 의복 생산 공정의 자동화를 위해 꾸준히 연구되고 있다. 이러한 어패럴 캐드 시스템의 주요한 목표 중의 하나가 소량 주문 생산에의 대응이다. 그런데 인체의 형태는 매우 다양하므로 개개인의 인체 형태에 대응하는 적합한 의복 디자인을 위해서는 먼저 정확한 인체 형태의 정확한 계측이 필요하다. 인체 데이터의 3차원적인 제품들인 계측은 그동안 많은 연구가 이루어져 상업화된 제품도 다수 출시되었다. (중략)

  • PDF

3D 스캔 데이터를 활용한 밀착 패턴원형 개발 (Development of 2D Tight-fitting Pattern from 3D Scan Data)

  • 정연희;홍경희
    • 한국의류학회지
    • /
    • 제30권1호
    • /
    • pp.157-166
    • /
    • 2006
  • The human body, which is composed of concave and convex curvatures, makes it difficult to transfer into 2D patterns directly from 3D data. In previous studies. Jeong, et al.(2004) suggested the block method was fester and easier when dealing with the triangular patches of male's upper dress form. Although the block method is useful to make a pattern, the information(area, length, etc.) from a 2D pattern would be different depending on the direction of the block method. As a result horizontal and diagonal block methods were suggested as optimal methods for 2D tight-fitting patterns. These block methods were closer to the original area of the 3D scan data than the vertical block method. The total area of the 2D pattern obtained by the horizontal and diagonal block methods showed little differences. In case of the horizontal and diagonal block methods, the total error of the 2D pattern area ranged from $0.01\%\~0.25\%$. In comparing the length of the 2D pattern with that of the 3D scan data, the obtained 2D pattern was $0.1\~0.2cm$ shorter than the 3D scan data, which was within the acceptable range of errors in making clothes. 3D space distribution images between the body surface and the experimental clothing were also measured and $3\%$ enlargement of the original pattern was verified as the adequate adjustment.

Classification of Upper Body Somatotypes according to the Age Group : Using 3D-Body Scan Data

  • Na, Hyun-Shin
    • International Journal of Costume and Fashion
    • /
    • 제5권1호
    • /
    • pp.1-13
    • /
    • 2005
  • Two hundreds of female aged 19 years old and up were recruited to evaluate the postural changes and bilateral variation of asymmetry over age. To find out the differences among the age group, subjects were classified into 5 groups, early young age(19-29), late young age(30-39), early middle age(40-49), late middle age(50-59), and old age(60-). 35 body measurements were taken by the 3-D body scanner which allowed us to take measurements which cannot be measured using traditional methods, including the shape of a cross section, slice area surface are, and volume. Bilateral variations were observed as a function of age; Depth of scapular point level, scapular point to center back, and blade angle. Postural change of anterior cervical angle, upper anterior thoracic angle, upper posterior thoracic angle, posterior cervical angle, and center back/center front ratio were also exhibited. In each measurements, subjects were classified into normal, and abnormal group. Percentiles of abnormal in shoulder line angle, blade angle, neck point $\∼$ acromial point $\∼$ scapular point, posterior cervical angle, and upper posterior thoracic angle were increased over age group. The upper body of lateral view was classified into 3 types of posture based on the previous research; straight, erect(leaning back), and stooped(bent forward). The percentiles of subjects who have straight postures were decreased as a function of age, but those of stooped postures were increased. Subjects who have erect postures did not so. The stooped posture group shows the big cervical fossa angle, anterior cervical angle, posterior cervical angle, upper posterior thoracic angle, and the small upper anterior thoracic angle comparing to the straight and erect posture group. These results could be apply for clothing construction reflecting the changes in back, shoulder, neck, and the bilateral asymmetry according to the target age group.

Height-Based Formula Predicting Renal Length in Korean Children derived from Technesium-99m Dimercaptosuccinic Acid Scan

  • Cho, Myung Hyun;Yoo, Ha Yeong;Kwak, Byung Ok;Park, Hye Won;Chung, Sochung;Kim, Soo Nyung;Son, Jae Sung;Kim, Kyo sun
    • Childhood Kidney Diseases
    • /
    • 제19권2호
    • /
    • pp.131-135
    • /
    • 2015
  • Purpose: The aim of this study was to establish a simple formula to predict renal length in children using a Technesium-99m dimercaptosuccinic acid (DMSA) scan data, and to compare it with the formula derived from ultrasonography, which is widely accepted. Methods: Children who underwent a DMSA scan and ultrasonography were reviewed retrospectively, and those who had anatomical urinary tract abnormalities or urinary tract infections were excluded. Results: A total of 230 children (84 males and 146 females; age, 1 month to 16 years; mean age, $16.8{\pm}27.4$ months). Mean renal length measured by DMSA scan was longer than that by ultrasonography ($6.38{\pm}1.16$ vs. $6.02{\pm}1.14cm$; P < 0.001). Renal length was correlated with age, weight, height, and body surface area on the DMSA scan and ultrasonography, and showed the strongest positive correlation with height. The following formulae were established to predict renal length: mean renal length (cm) = 5.433 ${\times}$ height (m) + 2.330 (R2, 0.833) using the DMSA scan data, and mean renal length (cm) = 5.367 ${\times}$ height (m) + 2.027 (R2, 0.853) using ultrasonography data. Conclusion: We propose a simple height-based formula to predict renal length in children using a DMSA scan data, and validate it by comparing with ultrasonography formula.

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • 한국의학물리학회지:의학물리
    • /
    • 제32권2호
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

Determination of Adequate Entry Angle of Lumbar Sympathetic Ganglion Block in Korean

  • Kim, Won-Ho;Kim, Sang-Kwon;Lee, Chul-Joong;Kim, Tae-Hyeong;Sim, Woo-Seok
    • The Korean Journal of Pain
    • /
    • 제23권1호
    • /
    • pp.11-17
    • /
    • 2010
  • Background: The target of lumbar sympathetic ganglion block is the anterolateral surface of the L2, 3 and 4 vertebral bodies, where the lumbar sympathetic ganglion usually lies. In most cases, a block-needle is inserted approximately 5-8 cm lateral to spinous process on the skin and directed to the anterolateral surface of vertebral body obliquely. The purpose of this study is to determine the safe entry angle and entry point in Korean by using the abdominal CT scan images. Methods: The abdominal CT images of eighty five patients were recruited to this study. The minimal angle aimed at the lumbar sympathetic ganglion that can pass through the lateral aspect of body and maximal angle that avoids puncturing the kidney, ureter or retroperitoneal space were measured. The distance from midline to skin entry point was also measured. Results: There was no significant difference in entry angle among L2, 3, and 4 level. The entry angle was similar in the right and left side, and in males and females. The entry angle of old age group was significantly smaller than that of young age group. The calculated safe entry angle was $30.5{\pm}0.4^{\circ}$ and entry point was $7.7{\pm}0.2\;cm$ and $6.7{\pm}0.1\;cm$ lateral from midline in males and females respectively. Conclusions: These measurements can be used as a reference for lumbar sympathetic ganglion block and radiofrequency lesioning. Prior to performing the lumbar sympathetic ganglion block for cancer patients, the abdominal CT scan should be reviewed to prevent complications.

3차원 파라메트릭 모델을 활용한 20대 성인 여성용 브리프 패턴 설계 (Briefs Pattern Making for Women in their 20's using 3D Parametric Human Body Model)

  • 최신애;박순지
    • 한국의류산업학회지
    • /
    • 제12권5호
    • /
    • pp.642-649
    • /
    • 2010
  • This study was designed to generate briefs pattern for women in their twenties using 3D parametric body model. 151 women in their 20's were random sampled and measured using Martine's anthropometry. And one subject was chosen as the representative subject for 3D scanning. Parametric model was generated of using CATIA P3, Unigraphics NX4.0, Rapidform 2006. And the 3D surface of parametric body model was flattened onto the 2D plane. 3 downscale ratios(0%, 10%, 15%) were applied to generated pattern to figure out what downscale ratio was suitable to make briefs with stretch fabric. 4 kinds of experimental briefs were made with stretch fabrics(0%, 10%, 15% downscale) and worn on the dressform. Subjective evaluation on the appearance was done and the data was analyzed by ANOVA with post-hoc test. Briefs pattern was generated through the process of flattening the parametric surface and arranging the patches to make briefs pattern by dart manipulation. The different ration of outline and area between 3D surface and 2D pattern were 0.22% and 0.09% respectively. It showed that a parametric model could provide a desirable pattern with minute size error. The results of subjective evaluation on the appearance of 4 experimental briefs showed that stretch briefs with 15% downscale ratio was evaluated most highly in most items. Findings imply that it is feasible to apply 3D parametric model to generate patterns for various items considering various fabric properties.

3D Body Scanning Data를 활용한 중년 남성용 슬림 핏(Slim-fit) 드레스 셔츠 바디스 패턴개발연구 (Bodice Pattern Development of the Slim-fit Dress Shirt for Middle-aged Males Using 3D Body Scanning Data)

  • 서추연
    • 한국의류학회지
    • /
    • 제40권1호
    • /
    • pp.171-187
    • /
    • 2016
  • The study performed a comparison analysis of market brand patterns for slim-fit dress shirts and analyzed the body surface development figure of men in their 40s using 3D body scan data and developed slim-fit dress shirt patterns suitable for middle-aged men. The sizes of slim-fit dress shirt patterns showed a slight difference depending on brand. The overlap map of slim-fit dress shirt patterns for brands demonstrates how difference of one-dimensional sizes reflect on two-dimensional patterns. This map provides useful information for pattern design and allows and easy recognition of pattern size differences. A try-on system evaluation through 3D-Simulation allows a grasp of the fitness of neckline and size tolerance of under the arms in front, the silhouette of side lines, and overall fitness in front that also allows analysis of the front/back balance of a shirt in side, the size tolerance proportion in front/back, and the fitness of the arm-hole line. Thus, we obtained try-on results that were equivalent to wearing actual clothing. According to the drafting size suggested in the developed final pattern, the total width was 'C/2+5.5cm', and the front was set at 1cm bigger in the size difference of the front and back. The width of the front neck and the back neck was set identically at 'C/12', while the width of the front neck was set to 'C/12+1.5cm'. For the armhole depth, we added 'C/4+2cm', and '0.5cm and 1.5cm' for the width of the front and back to anthropometry. The results of the try-on evaluation through 3D-Simulation indicated that the fitness of the final slim-fit dress shirt pattern was superior to available slim-fit dress shirt patterns on the market and evaluated as superior to the types for middle-aged men.