• Title/Summary/Keyword: Body segment

검색결과 307건 처리시간 0.022초

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권6호
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

Expressional Modulation of Aquaporin 1 and 9 in the Rat Epididymis by an Anabolic-Androgenic Steroid, Nandrolone Decanoate

  • Lee, Ki-Ho
    • 한국발생생물학회지:발생과생식
    • /
    • 제25권4호
    • /
    • pp.245-255
    • /
    • 2021
  • The spermatozoa become mature in the epididymis which is divided into initial segment and caput, corpus, and cauda epididymis. The water movement across the epididymal epithelium is important for creating luminal microenvironment for sperm maturation. Aquaporins (Aqps) are water channel proteins, and expression of Aqps is regulated by androgens. The current research was focused to examine expressional regulation of Aqp1 and Aqp9 by an androgenic-anabolic steroid, nandrolone decanoate (ND). The ND at the low dose (2 mg/kg body weight/week) or high dose (10 mg) was subcutaneously administrated into male rats for 2 or 12 weeks. Transcript levels of Aqp1 and Aqp9 were determined by quantitative real-time polymerase chain reaction (PCR) analyses. In the initial segment, level of Aqp1 was decreased with 12 week-treatment, while Aqp9 level was decreased by the high dose treatment for 12 weeks. In the caput epididymis, Aqp9 expression was decreased by the low dose treatment. The 2 week-treatment resulted in an increase of Aqp1 level but a decrease of Aqp9 expression in the corpus epididymis. In the corpus epididymis, the 12 week-treatment at the low dose caused the reduction of Aqp1 and Aqp9 levels, but the high dose treatment resulted in an increase of Aqp1 expression and a decrease of Aqp9 level. In the cauda epididymis, Aqp1 expression was decreased by 2 and 12 week-treatments, while increases of Aqp9 levels was detected with the high dose treatment for 2 weeks and with 12 week-treatment. These findings indicate differential regulation of Aqp1 and Aqp9 expression among epididymal segments by ND.

3차원 프린팅을 이용한 어린이용 무릎보호대의 분절형 하드쉘 설계 (Segmental Hard Shell Design of Knee Protector for Children Using 3D Printing)

  • 이효정;이예진
    • 패션비즈니스
    • /
    • 제21권4호
    • /
    • pp.116-126
    • /
    • 2017
  • This study applied a segmented hard shell design on knee protectors for children with the objective of increasing mobility. The prototype of the hard shell that does not correspond to movement of the body among components of the knee protector was developed. Surface modeling was conducted based on 3D knee data to enhance comfort through optimized fit on the knee joint where the hard shell would be worn. For this, previous studies on changes in skin near the knee joint during knee flexion were reviewed to establish basic segmental lines. The basic design included six segments, and the number of segments was used as the design variable by increasing or decreasing it to 0, 3, 6, 9, and 14 segments. A prototype was produced from 3D printing with TPU material, worn for wearing assessment. Results revealed fewer numbers of segments resulting in less fit with the body, while actual appearance was stable. Meanwhile, the number of proper segments improved better fit with the body during movement. The wearing assessment revealed the amount of gap reflects change in skin length depending on movement. Assessment results demonstrated basic segment design, S6 with 6 segments, had the best design and most optimized fit. Findings in this study can provide key data for designing knee protection products for children.

Successful removal of a foreign body by endoscopic balloon dilatation at the colonic stricture

  • Im, Chang Jo;Na, Ji Hoon;Kim, Hyun Sik;Ha, Sung Sam;Lim, Yoo Li;Lee, Ji Hyeon;Choi, Hee Kyoung;Kim, Hee Man
    • Journal of Yeungnam Medical Science
    • /
    • 제33권1호
    • /
    • pp.29-32
    • /
    • 2016
  • Most ingested foreign bodies pass readily throughout intestinal tract if they reach the stomach. In some cases, foreign bodies may be impacted behind a luminal constriction but are rare in colon. Here, we report the case of a 59-year-old man who did laparoscopic anterior resection due to sigmoid colon cancer 2 years ago and ischemic colitis was repeated on the anastomosis site. He initially presented with symptoms of abdominal pain 3 months before and melena 1 day before admission. Abdomen computerized tomography showed a 3.2 cm segment of luminal narrowing of the proximal colon involving upstream foreign material stasis. Sigmoidoscopic approaches revealed near complete obstruction on the anal verge of 20 cm and scope passing failed. Balloon dilatations were done on the obstruction site four times all and a foreign body impacted above the obstruction site was removed by an alligator without any complications. The foreign body removed looks like plastic or a shell, about 20 mm in size.

A Case of Endobronchial Aspergilloma Associated with Foreign Body in Immunocompetent Patient without Underlying Lung Disease

  • Jung, Seung Won;Kim, Moo Woong;Cho, Soo Kyung;Kim, Hyun Uk;Lee, Dong Cheol;Yoon, Byeong Kab;Jeong, Jong Pil;Ko, Young Choon
    • Tuberculosis and Respiratory Diseases
    • /
    • 제74권5호
    • /
    • pp.231-234
    • /
    • 2013
  • Aspergillus causes a variety of clinical syndromes in the lung including tracheobronchial aspergillosis, invasive aspergillosis, chronic necrotizing pulmonary aspergillosis, allergic bronchopulmonary aspergillosis, and aspergilloma. Aspergilloma usually results from ingrowths of colonized Aspergillus in damaged bronchial tree, pulmonary cyst or cavities of patients with underlying lung diseases. There are a few reports on endobronchial aspergilloma without underlying pulmonary lesion. We have experienced a case of endobronchial aspergilloma associated with foreign body developed in an immunocompetent patient without underlying lung diseases. A 59-year-old man is being hospitalized with recurring hemoptysis for 5 months. X-ray and computed tomography scans of chest showed a nodular opacity in superior segment of left lower lobe. Fiberoptic bronchoscopy revealed an irregular, mass-like, brownish material which totally obstructed the sub-segmental bronchus and a foreign body in superior segmental bronchus of the lower left lobe. Histopathologic examinations of biopsy specimen revealed fungal hyphae, characteristic of Aspergillus species.

체성분 측정용 스마트 의류 개발의 가능성 탐색 (An Exploratory Study on the Development of a Healthcare Smart Clothing for Measurement of Body Composition)

  • 문희성;조현승;박선형;이주현;차기철;신선영;정효일
    • 감성과학
    • /
    • 제10권3호
    • /
    • pp.383-391
    • /
    • 2007
  • 본 연구에서는 체성분 측정용 스마트 의류의 프로토타입을 개발하고 평가함으로써 헬스케어 의류로써의 개발 가능성을 탐색하고자 하였다. 직물 전극을 사용하여 개발된 두 가지 타입의 실험의복을 피험자에게 착용하도록 한 후 자세의 변화 및 1차 착용, 탈의 후 2차 착용에 따른 체성분을 측정한 결과, 동일 자세 내에서와 탈의 후 재착용 시에도 비교적 일관성 있는 측정치를 얻을 수 있었으며, 동일 자세에서는 의복 유형 및 반복 착용에 관계 없이 비교적 일관된 임피던스 측정치를 얻을 수 있었다. 또한 착용자의 신체 부위별 측정도 가능한 것으로 분석되어 향후 본 연구를 바탕으로 체성분 측정용 스마트 의류 개발이 가능할 것이라 판단된다.

  • PDF

뉴 시니어 여성을 위한 아웃도어 웨어 디자인 개발 - CLO 3D를 활용한 여름용 상의 디자인 - (Design Development of Shirts in Outdoor-Wear for New Senior Women's Using 3D Simulation Software - CLO 3D -)

  • 지경하;최윤미
    • 복식
    • /
    • 제65권5호
    • /
    • pp.62-73
    • /
    • 2015
  • The aim of this research is to propose the final shirt design modified for new senior women that fulfills their emotional and physical needs. The modifications were based on the results of in-depth interviews and literature search, and the study was conducted in order to understand the desires and preferences of senior women, as consumption of outdoor-wear by the group continues to increase. To develop the design of outdoor-wear that satisfies the physical and emotional qualities and preference of the new senior women, six different designs with lines, combined materials, as well as materials that were layered, pleated and draped were proposed using virtual-dressing simulation software. Then, the modified designs were derived from the six original designs by reflecting the opinions collected in the in-depth interviews with eleven women in their 50s. The responses in the interviewed showed a preference for lines, pleats and layers, as these features made the clothes look trendy, gave it a slender-look, and improved the body shape of the women. As the color is the critical factor for outdoor-wear, there was an overwhelming preference for primary colors by the women, which was in contrast to their color preference in general clothes. A sleeve design modification was proposed to convert the half-sleeves to 3/4-long sleeves in order to account for changes in body temperature at menopause, and to satisfy the aesthetic needs for covering wrinkles. Research of new senior outdoor-wear designs will help segment and differentiate strategies for the increasingly fierce competing outdoor market, as well as l provide directions in the design creation process using the simulation of 3D virtual model.

A New Experimental Error Reduction Method for Three-Dimensional Human Motion Analysis

  • Mun, Joung-Hwan
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권5호
    • /
    • pp.459-468
    • /
    • 2001
  • Average Coordinate Reference System (ACRS) 방법은 인체 보행 분석 시 발생하는 실험오타를 줄이기 위해서 개발되었다. 실험적으로 측정되어지는 운동학 데이터가 인체 모델링 분석을 수행하기 위해서 사용되어지며. 그 모델의 정확성은 그 측정된 데이터에 직접적인 연관 관계가 있다. 그러나, 인체가 보행하는 동안에 피부의 움직임과 골격구조의 변형이 발생하고 또한 운동 분석 실험장비 자체가 가지고 있는 여러 가지의 한계 때문에. 그 실험 데이터에 정확도는 의문시되어 진다 개발된 ACRS 방법은. 인체 운동분석을 수행하는 여러 종류의 시스템에 적용할 수 있는데. 본 연구에서는 ACRS 방법을 광학적으로 추적이 되는 표적을 인체의 각 세그멘트에 붙인 시스템에 적용하였다 ACRS 방법에서는. 각 세그멘트에 붙어있는 각각의 표적들이 독립적으로 그 세그멘트 안에서 국부좌표계의 원점으로 취급되어질 수 있다. 실험 과정에서 발생하는 본래부터의 오타 때문에. 각 원점에서 계산된 Euler angle은 서로 상이한 값을 갖는다 실험 초기에 측정한 보정 세그멘트 기준 프레임의 지식을 이용하면, 각 표적 위치에서 계산된 Euler angles들의 평균값을 계산할수 있고, 그 평균값은 피부의 확장과 회전의 영향을 최소화한 값이다. 운동분석에 일반적으로 적응되는 Euler angle 방법과 개발된 ACRS 방법을 비교하여 보면. ACRS 방법을 사용하였을 때 오차가 줄어들었다 만약에, 보행 실험 데이터에 오타가 존재하지 않는다면, 절대좌표계를 사용한 무릎 관절의 분리와 관통된 거리는 일회 보행구간 동안에 제로가 될 것으로 생각된다. 일반적으로 적용되는 Euler angle 방법을 적용하였을 때, 분리와 관통된 거리는 약 18 mm 가지 분포가 되었고, 개발된 ACRS 방법을 사용하였을 시에는 약 12 mm 까지 분포가 되었다.

  • PDF

학습과 시험과정 일체형 신경회로망의 하드웨어 구현 (The Implementation of Digital Neural Network with identical Learning and Testing Phase)

  • 박인정;이천우
    • 전자공학회논문지C
    • /
    • 제36C권4호
    • /
    • pp.78-86
    • /
    • 1999
  • 신경회로망은 학습 시에는 입력패턴이 변하지 않고 조정된 결합계수 값을 레지스터에 저장시키며, 시험시에는 반대로 결합계수가 고정되고, 레지스터에 입력패턴을 기억시킴으로써 학습과 시험 뉴런회로를 공유할 수 있는 특성을 가지고 있다. 본 연구에서는 신경회로망의 이러한 특성을 고찰하여, 신경회로망 구현시 게이트의 수를 줄일 수 있으며, 학습(learning) 및 시험(testing)시의 연산처리 시간을 단축시키기 위하여 곱셈연산 대신 어드레싱 LUT를 사용하여 학습과 시험이 동일한 신경회로망에서 수행할 수 있는 일체형 디지털 신경회로망 구현을 제안하였다. 제안한 신경회로망의 동작을 검증하기 위하여 수정된 오차역전파 학습 알고리듬에 의한 학습과정을 소프트웨어와 VHDL로 시뮬레이션 하였다. 7-segment 인식기 학습을 비교 검토한 결과, 입력패턴에 따라 다소 학습시간 및 학습횟수의 차이는 있지만 대체로 반복회수는 1000∼10000회 정도로 학습시간은 4∼20㎲로 나타났다. 신경회로망의 동작이 소프트웨어 시뮬레이션 학습 진행 상황과 동일하게 학습됨을 알 수 있었고 구현한 신경회로망이 정상적으로 수행됨을 확인하였으며, 또한 초기치 변화에 대한 실험에서도 초기치의 변화에 구애받지 않고 원활하게 학습되었다. 또한 본논문에서 구현된 신경회로망은 기존의 보드형 신경회로망보다 적은 수의 소자로 구현됨을 보였다.

  • PDF

복싱 잽(jab) 동작 시 제자리 스텝의 사용이 운동역학적 변인에 미치는 영향 (The Effect of Using Standing Step Condition on Biomechanical Variables during Jab in Boxing)

  • 이성열;권문석
    • 한국응용과학기술학회지
    • /
    • 제37권2호
    • /
    • pp.232-240
    • /
    • 2020
  • 본 연구는 복싱 잽 동작 시 제자리 스텝의 사용이 운동역학적 요인들에 미치는 영향을 분석 하는데 목적이 있었다. 이를 위해 최근 1년간 근골격계에 상해가 없었던 오른손잡이 스탠스 유형의 대학교 복싱 선수 8명(나이: 20.38±0.52 yrs, 신장: 172.38±5.80 cm 체중: 63.45±8.56 kg, 경력 6.00±1.07 yrs)이 실험에 참여하였다. 잽 동작 시 제자리 스텝 사용이 운동역학적 요인들에 미치는 영향을 검증하기 위하여 대응표본 t-test(α = .05) 통계방법을 사용하였으며 다음과 같은 결과를 도출하였다. 첫째, W.S(with-step) 가 N.S(non-step) 보다 더 큰 충격력을 나타내었고, 근육의 활성도는 낮은 것으로 분석되었다. 둘째 W.S가 인체 분절의 전방의 속도의 영향을 미쳐서 골반과 발 분절이 더 빠르게 이동하는 것으로 분석되었다. 셋째, W.S는 골반의 회전 움직임이 더 빠른 것으로 나타났다. 넷째, W.S는 N.S보다 상대적으로 오른발과 왼발에 의해서 발생된 전방의 지면반발력이 더 큰 것으로 분석되었다. 이를 통해서 복싱 잽 동작 시 제자리 스텝의 사용은 지면반발력을 증가시켜 인체 분절의 이동 속도와 회전 움직임에 영향을 미치는 것으로 나타났다. 따라서 더 빠르고 민첩한 움직임을 가능케 하여 상대적으로 적은 근육의 사용으로도 더 큰 충격력을 내는 것으로 확인되었다. 그러므로 복싱의 잽 동작 시 효율적으로 상대방에게 큰 충격력을 전달하기 위해서는 제자리 스텝을 동반하는 것이 효과적으로 분석된다.