• Title/Summary/Keyword: Body scan data

Search Result 218, Processing Time 0.033 seconds

Interactive 3D Pattern Design Using Real-time Pattern Deformation and Relative Human Body Coordinate System (실시간 패턴 변형과 인체 상대좌표계를 이용한 대화형 3D 패턴 디자인)

  • Sul, In-Hwan;Han, Hyun-Sook;Nam, Yun-Ja;Park, Chang-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.12 no.5
    • /
    • pp.582-590
    • /
    • 2010
  • Garment design needs an iterative manipulation of 2D patterns to generate a final sloper. Traditionally there have been two kinds of design methodologies such as the flat pattern method and the pattern draping method. But today, it is possible to combine the advantages from the two methods due to the realistic cloth simulation techniques. We devised a new garment design system which starts from 3D initial drape simulation result and then modifies the garment by editing the 2D flat patterns synchronously. With this interactive methodology using real-time pattern deformation technique, the designer can freely change a pattern shape by watching its 3D outlook in real-time. Also the final garment data were given relative coordinates with respect to the human anthropometric feature points detected by an automatic body feature detection algorithm. Using the relative human body coordinate system, the final garments can be re-used to an arbitrary body data without repositioning in the drape simulation. A female shirt was used for an example and a 3D body scan data was used for an illustration of the feature point detection algorithm.

A Study of Applications of 3D Body Scanning Technology - Focused on Apparel Industry - (3차원 바디 스캐너를 활용한 가상착의에 관한 인식 조사 - 업체 실무자 및 소비자를 대상으로 -)

  • Paek, Kyung-Ja;Lee, Jeong-Ran;Kim, Mi-Sung
    • Korean Journal of Human Ecology
    • /
    • v.18 no.3
    • /
    • pp.719-727
    • /
    • 2009
  • The ultimate success of commercial applications of body scan data in the apparel industry will be consumers' substantial applications such as automated custom fit, size prediction, virtual try-on, personal shopper services (Loker, S. et al., 2004). In this study, we surveyed fifty consumers and forty-seven apparel industry workers about their recognition and interest in 3D body scanning and virtual try-on. The results are as follows: 55% of the apparel industry workers has recognized 3D body scanning as a convenient technology, but do not know how to use it. To the questions regarding virtual try-on, 53% of the workers give positive answers. The consumers have a more positive view on virtual try-on than the workers do. The workers predict that the application of 3D body scan technology to the apparel industry could offer customers helpful information in their clothing selection by using virtual images of various size and style, and increase mass production of MTM(Made-To-Measure). The answers from the male consumers in their twenties indicate that virtual try-on is useful by 88% on offline shopping and by 100% on online shopping. 53% of the workers and 68% of the consumers gave answers that just by virtual try-on they could judge the quality of the apparel products and purchase them. Absolutely 3D virtual try-on is an effective tool for online shoppers. 85% of the workers anticipate applications of the 3D body scanning also in 'body measurement', 'custom pattern development' as well as 'virtual try-on' in the near future. With the positive reactions and the stimulating interests in virtual try-on, the conditions of contemporary world encourage more active researches and wide usages of the technology in apparel industry.

Classification of Lower Body Types of Female Adults aged 18 to 69 based on 3D Body Scan Data - Focusing on the Front Type, Lateral-Front Type, and Lateral-Back Type -

  • Kim, Min Kyoung;Nam, Yun Ja
    • Fashion & Textile Research Journal
    • /
    • v.18 no.1
    • /
    • pp.91-102
    • /
    • 2016
  • This study classified the lower body types of female adults aged 18 to 69. The lower body was divided into front, lateral front, and lateral back. In order to understand the shape and somatotype of each segment, 592 people were analyzed based on girth, height, length, depth, width, angle and cross section distance for each segment. For data analysis, SPSS 18.0 was performed for descriptive statics, principal component analysis, K-means cluster analysis, ANOVA, and Duncan's test (as verification). Factor analysis was performed based on index values, calculation values, angles, and cross section distances. The measured items resulted in a.) 16 items were extracted to 5 factors in the case of the front factor (FF) of the lower body, and b.) 24 items were extracted to 6 factors in the case of lateral front factor (LFF) and lateral back factor (LBF). Each factor was put through K-means cluster analysis, classifying the lower bodies into one of four types of based on the front type (FT), the lateral front type (LFT), and the lateral back type (LBT) respectively. This study proposed an understanding of various lower body shapes by segmenting and classifying the lower body shapes for each type.

Examination about Utility of Prone Position in PET/CT of Stomach Cancer Patient (위암 환자의 양전자 방출 컴퓨터 단층 검사에서 복와위(伏臥位) 촬영의 유용성에 대한 연구)

  • NamKoong, Hyuk;Park, Hoon-Hee;Oh, Shin-Hyun;Bahn, Yung-Kag;Kim, Jung-Yul;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.93-99
    • /
    • 2010
  • Purpose: Currently, PET/CT scan has been known to provide useful information to both preoperative and postoperative examination of cancer patients. Contracted stomach by the long fasting could cause difficulties of interpretation because of its size on reconstructed image data. To solve this problem, after the whole body PET/CT scan, patients were administrated in drinking 300 mL of water to expand stomach and performed additional scan on stomach region. Not only PET/CT scan but also CT performs this water-administration, and patients were take oral solution to make stomach expand for stomach cancer. When this scan performed, patients lay supine position. In this study, we evaluated the capacity of stomach through PET/CT scan with drinking water performed in supine and prone position so that we can distinguish exact location of cancer around pylorus and inferior wall of stomach. Furthermore, image data from supine and prone positions were analyzed the difference of volume of stomach through the change of standardized uptake values. Materials and Methods: From July 2009 to January 2010 in severance hospital, 30 patients who were diagnosed as early gastric cancer or advanced gastric cancer were chosen. All patients had PET/CT scan before the operation and have had follow-up PET/CT. The patients fast for at least 8 hours, and had an injection intravenously with $^{18}F$-FDG, 7.4 MBq (0.2 mCi/kg) per kilogram. They were rested for 60 minutes. Before the examination, all patients were administrated to drink water for 300 mL Patients had PET/CT scan with supine position around the region of stomach, whole body, and around the region of stomach with prone position after drinking another 300 mL of water respectively. Results: As a results of comparison between stomach capacity of 30 patients in supine and prone position, the study draw results that average capacity of stomach body was 460.29 $mm^2$ in supine position, and 641.39 $mm^2$ in prone position for 30 patients. The change of capacity shows 41.3% expanded in prone position. And there was no noticeable difference at maximum standardized uptake values in supine position and prone position. Conclusion: As results, stomach would have more expanded capacity in prone position than supine position. For patients who have physical disabilities to move freely, additional scan in prone position will be obstacle to perform. However, if additional scan in supine position add with the scan in prone position, it will be easier to diagnose stomach cancer. Moreover, we believe that this study will help the research for inventing support tools for patients who have physical disabilities in prone position.

  • PDF

Classification of Upper Body Somatotypes according to the Age Group : Using 3D-Body Scan Data

  • Na, Hyun-Shin
    • International Journal of Costume and Fashion
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Two hundreds of female aged 19 years old and up were recruited to evaluate the postural changes and bilateral variation of asymmetry over age. To find out the differences among the age group, subjects were classified into 5 groups, early young age(19-29), late young age(30-39), early middle age(40-49), late middle age(50-59), and old age(60-). 35 body measurements were taken by the 3-D body scanner which allowed us to take measurements which cannot be measured using traditional methods, including the shape of a cross section, slice area surface are, and volume. Bilateral variations were observed as a function of age; Depth of scapular point level, scapular point to center back, and blade angle. Postural change of anterior cervical angle, upper anterior thoracic angle, upper posterior thoracic angle, posterior cervical angle, and center back/center front ratio were also exhibited. In each measurements, subjects were classified into normal, and abnormal group. Percentiles of abnormal in shoulder line angle, blade angle, neck point $\∼$ acromial point $\∼$ scapular point, posterior cervical angle, and upper posterior thoracic angle were increased over age group. The upper body of lateral view was classified into 3 types of posture based on the previous research; straight, erect(leaning back), and stooped(bent forward). The percentiles of subjects who have straight postures were decreased as a function of age, but those of stooped postures were increased. Subjects who have erect postures did not so. The stooped posture group shows the big cervical fossa angle, anterior cervical angle, posterior cervical angle, upper posterior thoracic angle, and the small upper anterior thoracic angle comparing to the straight and erect posture group. These results could be apply for clothing construction reflecting the changes in back, shoulder, neck, and the bilateral asymmetry according to the target age group.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

A Study of the Patternmaking Methods for Mass Customization of the Men's Jacket (남성복 재킷의 Mass Customization을 위한 패턴 제작 방법 연구)

  • Oh, Seol-Young;Chun, Jong-Suk;Suh, Dong-Ae
    • The Research Journal of the Costume Culture
    • /
    • v.14 no.1
    • /
    • pp.40-47
    • /
    • 2006
  • Three-dimensional body scanners were used for years in the clothing manufacturing fields. The 3D body surface provide essential data to draft patterns for mass customization, virtual fit model, and computerized patternmaking systems. This research proposed the methods of drafting patterns for men's jacket by using three dimensional body scan data. Eight male subjects were scanned, the surface data was flattened. The differentials of the flattened body surface and the jacket draft were measured, and analyzed the regressions. To verify the fit of the patterns, the jacket was constructed by the regression formulae and tested by experts. The fit of the jacket were significantly improved rather than a ready-made suit especially the shoulder areas. This means that the methods that we proposed were good to improve the fit of the garments and could be used effectively to implement mass customization strategies in the apparel retail industry.

  • PDF

Technical Design of Tight Upper Sportswear based on 3D Scanning Technology and Stretch Property of Knitted Fabric (3차원 스캔 기술과 니트 소재의 신축성을 적용한 밀착형 스포츠웨어 상의 설계)

  • Kim, Tae-Gyou;Park, Soon-Jee;Park, Jung-Whan;Suh, Chu-Yeon;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.277-285
    • /
    • 2012
  • This research studied how to develop tight upper sportswear from 3D scan data considering fabric stretch property. Subjects were five Korean men of average figure in their 20's. Scanning was done for ten postures via vitus smart/pro(Techmath LTD). Analyzing from 3D scan data, more than 70% of the upper body surface showed surface change rate under 20%. It was shoulder and under arm side part that showed most noticeable body surface change when moving. A parametric model with convex surface was generated and flattened onto the plane, resulting 2D pattern. The error rate occurring in the process of 3D to 2D conversion was 0.2% for outline and 0.13% for area, respectively. Thirteen kinds of stretchable fabrics in the market were collected for this study. Stretch property was in the range of 16.0~58.2% for wale direction; 23.1~78.4% for course. Based on wear trial test, four fabrics were chosen for making the 1st experimental garment and finally one fabric was chosen for the 2nd one, which was developed applying 4 kinds of crosswise reduction rate on 2D pattern: 0, 5, 10, and 15%. Through wear trial test and garment pressure measurement, experimental garment applied with 10% pattern reduction rate was evaluated as most comfortable and considerable.