To evaluate the diagnostic value of pulmonary perfusion scan, we obtained 99mTc MAA per-fusion lung scan from 25 cases of airway foreign bodies. The results were as follows. 1) Significant changes in blood gases were not observed after the establishment of regional hypoperfusion caused by airway foreign body. 2) Near total or total defect was noted on perfusion scan from most of the airway foreign body. 3) There was correspondance of findings of perfusion lung scan and duration of airway foreign body. 4) After the removal of airway foreign bodies, perfusion scan abnormalities were reversed in parallel with the recovery of pulmonary blood flow. We concluded that pulmonary perfusion scan may be valuable for detection of foreign body and reversible hypoperfusion.
PURPOSE. The aim of this study was to examine the importance of the defect-free scanning of a scan body by assessing the accuracy of virtual implant positioning in computer-aided design (CAD) software when the scan body image is improperly scanned. MATERIALS AND METHODS. A scan body was digitized in a dentiform model using an intraoral scanner, and scanned images with differing levels of image deficiency were generated: 5%, 10%, and 15% deficiency in the flat or rounded area. Using a best-fit image matching algorithm on each of the deficient scan body images, corresponding virtual implants were created. The accuracy of the implant position was evaluated by comparing the linear and angular discrepancies between the actual and virtual positions of the implant. Kruskal-Wallis tests and Mann-Whitney U tests with Bonferroni correction were used to determine the statistical differences among the seven scanned image deficiency groups (α=.05). RESULTS. In general, the linear and angular discrepancies of the implant position in the software increased as the deficiency of the scan body images increased. A 15% scan body image deficiency generated larger discrepancies than deficiency of 5% and 10%. The difference of scan defect position, flat or rounded area, did not affect the accuracy of virtual implant orientation at 5% and 10% deficiency level, but did affect the accuracy at 15% deficiency level. CONCLUSION. Deficiencies in the scanned images of a scan body can decrease the accuracy of the implant positioning in CAD software when the defect is large, thus leading to the incorrect fabrication of implant prostheses.
Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.
In this paper, we suggest the method for constructing parameterized human body model which has any required body sizes from 3D scan data. Because of well developed 3D scan technology, we can get more detailed human body model data which allow to generate precise human model. In this field, there are a lot of research is performed with 3D scan data. But previous researches have some limitations to make human body model. They need too much time to perform hole-filling process or calculate parameterization of model. Even more they missed out verification process. To solve these problems, we used several methods. We first choose proper 125 3D scan data from 5th Korean body size survey of Size Korea according to age, height and weight. We also did post process, feature point setting, RBF interpolation and align, to parameterize human model. Then principal component analysis is adapted to the result of post processed data to obtain dominant shape parameters. These steps allow to reduce process time without loss of accuracy. Finally, we compare these results and statistical data of Size Korea to verify our parameterized human model.
The present study provides reference data required for the design of clothing for the elderly by analyzing the body surface area during fitness motion based on 3D scan data of Korean elderly women. This study was conducted with the procedures of (1) survey of motions and main muscles for fitness, (2) acquisition of 3D scan data, and (3) analysis of rate of change for body surface area during fitness motion. Acquisition of 3D body scan data was obtained from seven elderly females (age: 64-77). We selected 66 anatomical landmarks (40 upper body and 22 lower body) by referring to previous studies. Body surface was segmented by connecting the landmarks marked on the 3D scan data acquired. Analysis of body surface area was conducted in terms of the change rate of surface area in 9 postures of elbow 0°, 90° and 180° for flexion, shoulder 90°, 180° for flexion, shoulder 0°, 180° for abduction, hip 90° for flexion, and knee 90° for flexion compared to the those in the standing posture. The amount of changes in body surface area were 12%-62% in the upper body, 15%-77% in the arm, and 10%-51% in the lower body. A future study on the rate of change of body surface length is needed; in addition, a study on how to apply the results of body surface area and body surface length analysis to clothing pattern design is also necessary.
This study examined how to create 2D basic pattern of individuals by means of 3-D body figure, which is to develop a flat of individual basic pattern directly from the 3-D body scan data of each subject using that of the upper body of a male adult. In terms of methodology, this study adopted 3D body scan data on system and body to make examinations in the following steps: 1. Standard point and line were set on human body, along with 3-D definition points(feature points). 2. PB was created by modifying horizontal and longitudinal section of scan data. 3. Ways to set reserve were established in the findings of PB planar development. Respective developed flat patterns were compared with pattern findings in previous studies by means of sensory evaluation. As a result, it was found that both system and body model are basic pattern and belong to appropriate pattern as semi-tight-fit basic pattern with overall appropriate tolerances. Thus, this study came to a conclusion that it is feasible and valid to develop theories for flat development as considered herein.
The 3D measurement data expected be useful to give appropriate garment fit and development of MTM(Made-to-Measure) CAD software. The researcher surveyed the need and use of national anthropometric data of the apparel industry. 17 Korean apparel manufacturers participated in the study. The need of anthropometric data at 5 different apparel business sectors was measured: men's suit, women's dress, casual-wear, underwear, and active sportswear. The result of the survey shows that height and bust, waist, hip circumferences are needed by all of the business sectors. The body measurements at the scye and upper arm area were need most by the men's suit manufacturers. The women's foundation garment manufacturers were well prepared for the use of the 3D body scan data and they expected the potential benefits of 3D body scan data would be great. The researcher also conducted a case study and found a pro and con of the using 3D body scan data for apparel product developing process. In the current stage of technical advance, a reasonable method was required to get nude like scan data for the women's foundation garment manufacturer. The researcher concluded that the apparel designer could use the 3D scan data for developing tremendous style garment design and pattern making.
목적 : 분화된 갑상선암 환자에서 방사성옥소(I-131)를 이용한 전신스캔은 보통 수술 후 잔여 갑상선 조직, 재발된 병변 부위 또는 전이 병소 등을 찾는데 유용한 방법이다. 최근 고선량 방사성동위원소를 이용한 치료는 증가 추세에 있으며, 동위원소 치료를 위한 입원대기는 수개월씩 지연되고 있다. 본원에서는 정화조 설비를 확장하여 주당 치료 가능 인원이 증가되었고 이로 인해 I-131 전신스캔 환자가 늘어나면서 검사시간 또한 증가되었다. 이를 개선하기 위해 본 연구에서는 기존의 검사시간을 단축하면서 병소의 위치를 정확하게 구별할 수 있도록 Transmission scan tool을 제작하여 우수한 분해능을 가진 전신영상을 얻고자 한다. 실험재료 및 방법 : 2008년 2월부터 7월까지 본과를 내원하고 ORBITER Gamma Camera를 이용하여 I-131 전신스캔을 시행하는 환자를 대상으로 하였다. 먼저 전신 스캔을 시행한 후 Transmission scan를 위해 검사 Table에 Rail을 설치하고 $^{99m}Tc$-pertechnetate 2 mCi를 희석한 Flood phantom을 올려놓을 수 있는 Tool을 자체 제작하여 Transmission image를 얻어 전신 스캔에 Fusion 하였다. 결과 : I-131 전신스캔과 Transmission scan의 Fusion된 영상은 간단한 marking을 통하여 구강이나 침샘부위, neck 부위의 병소, 전이병소의 위치를 감별하는데 우수한 분해능을 가진다. 또한 추가적인 국소 영상이 불필요하여 8~28분 정도의 검사 소요시간을 단축할 수 있었다. 결론 및 고찰 : I-131 전신스캔에서 Transmission scan은 방사능의 감약을 통하여 체표면의 윤곽을 정확히 나타낼 수 있으며 미리 시행한 I-131 전신스캔과의 Fusion 영상을 통하여 분해능을 향상시킴으로서 잔여 갑상선 조직이나 전이병소 등의 위치를 나타내는데 유용하다. 또한 추가적인 국소영상 촬영이 불필요함에 따라 검사에 소요되는 시간을 단축할 수 있고, 체표면 윤곽을 나타내어 해부학적 위치를 파악하는데 도움을 줄 수 있는 다른 임상검사에도 확대 적용할 수 있을 것이다.
전신 뼈 검사에 이용되는 방사성의약품의 주된 집적부위는 뼈 무기질이며 그 섭취기전은 명백히 밝혀져 있지 않다. 전신 뼈 검사에서 일시적으로 미만성 간 섭취가 나타날 수 있으며, 간내 섭취의 원인은 다양하게 보고되고 있다. 본 연구에서는 전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취에 MRI 조영제가 미치는 영향을 알아보았다. 2010년 1월부터 12월 사이에 $^{99m}Tc$-DPD 전신 뼈 검사를 시행한 환자 중 982명을 연구의 대상으로 하였다. 982명의 환자는 전신 뼈 검사 이전에 MRI 조영제를 사용한 검사를 시행하였다. 혈액학검사 및 일반화학검사 소견을 조사한 결과 전신 뼈 검사에서 46명의 환자(남:여=39:7)가 미만성 간 섭취를 보였다. 추적 전신 뼈 검사를 시행하였으며, 이전에 보였던 미만성 간 섭취는 모두 소실되어 정상적인 소견을 보였다. 간기능 및 신기능 검사는 모두 정상이었다. 전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취에 MRI 조영제가 간접적인 영향을 주고 있다. $^{99m}Tc$-DPD의 미만성 간 섭취를 피하기 위해서 전신 뼈 검사는 MRI 조영제를 사용한 검사를 시행하기에 앞서서 먼저 시행하여야 하고, MRI 조영제를 사용한 검사가 있을 경우에는 조영제가 몸에서 제거된 후 검사를 시행하여야 할 것이다.
The objective of this study was to analyze body measurements, BMI and body type according to age in the male and female groups based on 3D scan body measurement data of adult men and women in their 20's~30's and to provide basic information usable in the clothing and fashion industry. For this purpose, we analyzed 3D scan body measurement data of 848 adults measured in the 6th Size Korea project and the results were as follows. First, there were differences in 3D scan body measurements according to age in the male and female groups, and in general the measurements of the height items were larger in younger adults and the measurements of the circumference, breadth and depth items were larger in older ones. Second, there were differences in 3D scan body measurements according to BMI in the male and female groups, and in general body measurements were largest in the obesity group and lowest in the underweight group. Third, BMI was different according to gender and in general BMI was higher in men and obesity and overweight were more frequent in men than in women. Moreover, BMI was significantly different according to age and was higher in the 30's than in the 20's. Fourth, the mean difference in the drop and lower drop values according to age in the male and female groups was significant, and the drop and lower drop values were lower in the 30's than in the 20's. These results are considered meaningful as data for the development of clothing size systems, patterns and grading in the areas of clothing and fashion targeting consumers in their 20's~30's.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.