• 제목/요약/키워드: Body interference

검색결과 174건 처리시간 0.03초

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

  • Yoo, Sun-K.
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권5호
    • /
    • pp.601-605
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

간호의 독자성을 위한 철학적 고찰 (Some Philosophical Considerations for Autonomy of Nursing Care)

  • 최남희;이남희
    • 대한간호학회지
    • /
    • 제18권1호
    • /
    • pp.19-25
    • /
    • 1988
  • To ensure the autonomy of nursing care aetivies is one of the major and most interesting issues in the field of nursing. The pertaining autonomy demands the nurse to make decisions of her or his own with out interference and free of help from other sides of health care agency. The whole process of autonomous nursing behavior should be judged and conveyed by the nurse only on the basis of the internal factors of her care to solve the problems of the client's disorder in health. Truth of nursing science and relevence of nursing conduct depend on our construction of internal basis and establishment of self-sufficient reference system. The information for efficient decision-making at the scene of nursing can only be supplied by a systematic body of nursing science consisting of true or properly corroborated propositions. The science of nursing can be autonomous when we have framework of explanation, independently of other sciences and the behavior of nursing care can factually be independent of and peculiar to that of other but similar fields only when the science of nursing is correspondently autonomous.

  • PDF

Manganese and Iron Interaction: a Mechanism of Manganese-Induced Parkinsonism

  • Zheng, Wei
    • 한국환경성돌연변이발암원학회지
    • /
    • 제23권4호
    • /
    • pp.115-130
    • /
    • 2003
  • Idiopathic Parkinson's disease (IPD) represents a common neurodegenerative disorder. While epidemiological studies have suggested a number of risk factors including age, gender, race, and inherited disorder, the cumulative evidence supports the view that environmental or occupational exposure to certain chemicals may contribute to the initiation and progress of Parkinsonism. More recently, clinical and laboratory investigations have led to the theory that dysregulation of iron, an essential metal to body function, may underlie IPD by initiating free radical reaction, diminishing the mitochondrial energy production, and provoking the oxidative cytotoxicity. The participation of iron in neuronal cell death is especially intriguing in that iron acquisition and regulation in brain are highly conservative and thus vulnerable to interference from other metals that bear the similar chemical reactivity. Manganese neurotoxicity, induced possibly by altering iron homeostasis, is such an example. In fact, the current interest in manganese neurotoxicology stems from two primary concerns: its clinical symptoms that resemble Parkinson's disease and its increased use as an antiknock agent to replace lead in gasoline. This article will commence with addressing the current understanding of iron-associated neurodegenerative damage. The major focus will then be devoted to the mechanism whereby manganese alters iron homeostasis in brain.

  • PDF

사람의 평형감각 측정시스템 개발 (Development of an Equilibrium Sensation Measuring System for Human Being)

  • 김갑순
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.62-69
    • /
    • 2009
  • This paper describes the development of the new type equilibrium sensation measuring system for human with handicap in the equilibrium sensation. The medium and small hospital could not use the developed equilibrium sensation measuring system, because it is very high prices. Therefore, the new type system should be developed to measure the numerical value of the equilibrium sensation in human with handicap. In this paper, First, two 3-axis force/moment sensors which can measure force Fz, moments Mx and My simultaneous were designed and manufactured, second, the high speed measuring device which can acquire the output from two 3-axis force/moment sensors, third, the new type equilibrium sensation measuring system was developed, then the characteristic test of the developed equilibrium sensation measuring system carried out, it is confirmed that the system could measure the swing body of human with handicap.

고분자복합소재차체를 적용한 바이모달트램의 전기적 절연 및 접지시스템에 관한 연구 (Study about Electrical Insulation and earthing system of Bimodal Tram with Polymer Composite Body)

  • 이강원;목재균;길경석;박대원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1063-1064
    • /
    • 2008
  • Bimodal tram has a carbody made of polymer composite material which is good electrical insulator. As an series hybrid type, Alternating voltage generated from generator coupled with CNG engine are rectified and transformed to variable voltage ranges which are applied to electrical apparatus and ECUs equipped inside of the tram. The failures of electrical insulation between high voltage($400V{\sim}800V$) and low voltage(24V) or between different kind of voltages such as AC and DC may cause some electrical interferences to prevent from operating rightly and other safety problem. This paper have investigated about the degradation factors of the electrical insulation and the earthing method available to bimodal tram, which is effective for preventing the electromagnetic interference coming from the inside or outside of tram but need some detecting measurements of earth leakage through electrical systems.

  • PDF

자가 슬괵근을 이용한 전방 십자 인대 재건술 후 발생한 전경골 낭종 - 증례 보고 - (Pretibial cyst after Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Autograft - A Case Report -)

  • 서승석;김창완;하동준;정훈재
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.53-57
    • /
    • 2009
  • The pretibial cyst is a very rare complication after anterior cruciate ligament (ACL) reconstruction. It occurs whatever kind of graft choice or kind of graft fixation method at tibial side. It have been known such as graft necrosis at tibial side, extra-articular leakage of joint fluid through tibial tunnel, foreign body reaction due to breakdown of the bioabsorbable screw and incomplete incorporation of graft to bony tunnel as the cause of pretibial cyst. We experienced one case of pretibial cyst which had undergone ACL reconstruction with autogenous hamstring graft fixed with biodegradable interference screw. We report a rare case of pretibial cyst with literature review.

  • PDF

WBAN 환경에서 채널 추정 기반의 공용 채널 간섭 제거 기술 (A Study on Co-channel Interference Cancelation Algorithm with Channel Estimation for WBAN System Application)

  • 김정곤;정두희;김문철;최준성;최성연
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2012년도 하계학술대회
    • /
    • pp.333-336
    • /
    • 2012
  • 본 논문은 2.4GHz 대역을 사용하는 WBAN(Wireless Body Area Network)환경에서 동일 채널을 사용하는 경우에 발생하는 간섭을 제거하기 위해 MMSE(Minimum Mean Square Error), OC(Optimal Combining), ML(Maximum Likelihood)을 비교 분석하였으며, IEEE 802.15.6에서 정의된 시나리오 및 채널 모델에 대해서 분석하였다. 모의실험 결과 ML 알고리즘이 가장 우수한 성능을 나타내는 것을 알 수 있었다. 하지만 ML과 OC의 경우 원하는 신호의 채널 정보뿐만 아니라 간섭채널의 정보를 알아야 하기 때문에 채널을 추정하기 위한 훈련 심볼의 자리를 수신노드에서 알고 있어야 하므로 WBAN환경에 적용하는데 어려움이 있다. 따라서 복잡도와 성능사이에 적당한 trade-off를 만족하는 간섭 제거 알고리즘을 연구해야 할 것이다.

  • PDF

힘센서를 이용한 후크형 손가락 힘 측정 장치 개발 (Development of a Hook-type Finger Force Measuring System with Force Sensors)

  • 김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제20권6호
    • /
    • pp.663-668
    • /
    • 2014
  • This paper presents a hook-type finger force measuring system with force sensors. The system is composed of a body, two three-axis force sensors, a hook, and so on. The two three-axis force sensors system was specially designed using FEM(Finite Element Method) and fabricated using strain-gages. The sensors measure the finger forces of both normal people and handicapped people in the system, and the forces are combined. The developed hook-type finger force measuring system can measure the pulling finger force of both normal and handicapped people. The pulling force tests of men and women were performed using the developed the system. It is thought that the developed system can be used to measure the pulling force of fingers.

The theory of non-Markovian optical gain in excited semiconductors

  • Ahn, Doyeol
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1995년도 광학 및 양자전자학 워크샵 논문집
    • /
    • pp.138-148
    • /
    • 1995
  • A reduced description of the dynamics of carriers in excited semiconductors is presented. Fristly, a time-convolutionless equation of motion for the reduced density operator is derved from the microscopic Liouville wquation operator method. Secondly, the quantum kinetic equations for intercting electron-hole parirs near band-edge in semiconductors under an extermal optical field are obtained from the equation of motion for the reduced density operator. The non-Markovian optical gain of a driven semiconductor is derived including the many-body effects. plasma screening and excitinic effects are taken into account using as effective Hamiltonian in the time-dependent Hartree-Fock approximation. it is shown that the line shape of optical-gain spectra gain is enhanced by the exicitonic effects caused by the attrative electron-hole Coulomb interaction and the interference effects (renormalized memory effects) between the extermal driving filed and the intermal driving Filed and the stochastic reservoir of the system.

  • PDF

Home Healthcare 장치를 위한 차동 전극 임피던스의 상대적인 측정 (Relative Measurement of Differential Electrode Impedance for Home Healthcare Device)

  • 우영재;유선국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.469-470
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.