• Title/Summary/Keyword: Body correction

Search Result 417, Processing Time 0.032 seconds

A Improved Scene based Non-uniformity Correction Algorithm for Infrared Camera

  • Hyun, Ho-Jin;Choi, Byung-In
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 2018
  • In this paper, we propose an efficient scene based non-uniformity correction algorithm which performs the offset correction using the uniform obtained from input scenes for Infrared camera. In general, pixel outputs of a infrared detector can not be uniform. Therefore, the non-uniformity correction procedure need to be performed to make the image outputs uniform. A typical non-uniformity correction method uses a black body at the laboratory to obtain the output of the infrared detector's pixels for two temperatures, HOT and COLD, and calculates the non-uniformity correction parameters. However, output characteristics of the Infrared detector changes while the Infrared camera is operated, the fixed pattern noise of the Infrared detector and dead pixels are generated. To remove the noise, the offset correction is generally performed. The offset correction procedure usually need the additional device such as a thermo-electric cooler, shutter, or non-uniformity correction lens. Therefore, we introduce a general scene based non-uniformity correction technique without additional equipment, and then we propose an improved non-uniformity correction algorithm based on image to solve the problem of the existing technique.

Physical Artifact Correction in Nuclear Medicine Imaging: Normalization and Attenuation Correction (핵의학 영상의 물리적 인공산물보정: 정규화보정 및 감쇠보정)

  • Kim, Jin-Su;Lee, Jae-Sung;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.112-117
    • /
    • 2008
  • Artifact corrections including normalization and attenuation correction were important for quantitative analysis in Nuclear Medicine Imaging. Normalization is the process of ensuring that all lines of response joining detectors in coincidence have the same effective sensitivity. Failure to account for variations in LOR sensitivity leads to bias and high-frequency artifacts in the reconstructed images. Attenuation correction is the process of the correction of attenuation phenomenon lies in the natural property that photons emitted by the radiopharmaceutical will interact with tissue and other materials as they pass through the body. In this paper, we will review the several approaches for normalization and attenuation correction strategies.

On the Use of Momentum Interpolation Method for flows Involving A Large Body force (바디포오스가 큰 유동해석시 운동량보간법의 사용에 관한 연구)

  • Choi Seok-Ki;Kim Seong-O;Choi Hoon-Ki
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.553-556
    • /
    • 2002
  • A numerical study on the use of the momentum interpolation mettled for flows with a large body force is presented. The inherent problems of the momentum interpolation method are discussed first. Numerical experiments are performed for a typical flow involving a large body force. The tact that the momentum interpolation method may result in physically unrealistic solutions is demonstrated. Numerical experiments changing the numerical grid have shown that a simple way of removing the physically unrealistic solution is a proper grid refinement where there is a large pressure gradient. An effective way of specifying the pressure and pressure correction at the boundary by a local mass conservation near the boundary is proposed, and it is shown that this method can effectively remove the inherent problem of the specification of pressure and pressure correction at the boundary when one uses the momentum interpolation method.

  • PDF

Cross-flow Analogy and Euler Solutions for Missile Body Aerodynamics

  • Lee, Jae-Myung;Park, Seung-O;Kim, In-Sun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.9-16
    • /
    • 2000
  • For aerodynamic design of missile bodies of non-circular cross-section, the combination of the slender body theory and the cross-flow analogy can hardly be applied owing to the lack of experimental data. An alternative is to utilize the Euler solution in the design stage. For enhanced accuracy, however, an adequate viscous correction is necessary to the Euler solution. In this work, such a procedure is examined to compensate the viscous effect by utilizing the concept of proportionality factor in cross-flow analogy. Predictions of aerodynamic coefficients combining the Euler solution and the viscous correction via proportionality factor are made for a missile body of elliptic cross-section. Results indicate that the present approach can be adopted in designing missile bodies of non-circular cross-sections.

  • PDF

Comparison of pants pattern by adolescent boy's body type using 3D virtual simulation

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.2
    • /
    • pp.75-84
    • /
    • 2019
  • The purpose of this study was to present a good pants pattern for boys aged 13-18 by comparing and analyzing the pants pattern according to lower body shape. And through it, this study was to provide basic data for pants production considering male student body shape. The pattern of this study used the industrial type Lee Hee-chun pattern and DC Suite Program for 3D virtual simulation. As a result of the appearance evaluation, there was a significant difference between the patterns in most items. Type 2 was rated highly, followed by Type 4, Type 3, and Type 1. Type 1 required correction of the length of the pants and the amount of crotch part, while type 3 required adjustment of the pants in the knee area. Type 4 required correction of pattern drawing method of crotch width, thigh circumference, and knee circumference. This pattern method was evaluated as suitable for slender body shape. This study suggests a pants pattern system suitable for adolescent boys by reflecting the body shape characteristics of adolescent boy with a change of body shape. It is expected that this will meet the increasing demand for fitting. In this study, we have examined 3D virtual simulation, not actual wear experiment, so it will be necessary to investigate the difference through actual clothing experiment for adolescent boys.

Surgical Treatment of Patients with Tetralogy of Fallot (활로 4 징증의 외과적 치료)

  • 이재동;이종태;김규태
    • Journal of Chest Surgery
    • /
    • v.22 no.1
    • /
    • pp.74-82
    • /
    • 1989
  • Ninety-six patients with tetralogy of Fallot have undergone either primary total correction [71], staged total correction [9], or an initial shunt [16], between January, 1984, and December, 1987 Their mean age was 9.5 years, mean body weight 24kg, and mean body surface area 0.86m2. Initial palliative shunt group had smaller size, smaller pulmonary artery, and higher hemoglobin [P value < 0.05 >. Modified Blalock-Taussig shunt was performed most commonly. Patch enlargement of right ventricle in 31 cases [38%], right ventricle and pulmonary artery in 7 cases [9%], transannular patch enlargement in 28 cases [35%], and valved conduit in 2 cases [2.5%] was performed for reconstruction of right ventricular outflow tract stenosis. Longer aorta cross clamp time was noted in case of separate patch enlargement of right ventricle and pulmonary artery, and dead patient with transannular patch enlargement [P value < 0.05]. There was no operative death in shunt group, but 7 deaths in total correction group [mortality rate 8.8%].

  • PDF

An Implicit Pressure Correction Method for Incompressible Navier-Stokes Equations on Unstructured Cartesian Grids

  • Pan Dartzi
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.15-16
    • /
    • 2003
  • An implicit pressure correction method on unstructured Cartesian grid is developed for the incompressible Navier-Stokes equations. An immersed boundary method is also incorporated to treat the body geometry. Tests show that with an appropriate amount of dissipation, the method is second order accurate both in time and space. The driven cavity flows with and without immersed bodies are computed to demonstrate the capability of the present scheme.

  • PDF

On the Three-dimensional Correction Factor for the Added Mass in the Vertical Vibration of the Ship. (선체(船體) 상하진동(上下振動)에 대(對)한 부가질량(附加質量)의 3차원(次元) 수정계수(修正係數)에 관(關)하여)

  • C.Y.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.11 no.2
    • /
    • pp.1-6
    • /
    • 1974
  • The three-dimensional correction factor of the added mass of finite-length elliptic cylinders in vertical vibration in a free surface was calculated. This problem has already been dealt by T. Kumai[5] to contribute to analytical prediction of the three-dimensional correction factor for the added mass in vertical vibration of ships. In Kumai's work, the body boundary condition involved in the appropriate boundary value problem was approximately treated in the course of obtaining the solution. In this work, obtaining the solution derived from mathematically exact treatment of the body boundary condition, the author recalculated the three-dimensional correction factor for length-beam ratio $4{\sim}8$, beam-draught ratio $2.00{\sim}4.50$ and number of nodes from 2 to 7. And the numerical results were compared with both Kumai's results and the author's experimental data for two and three-noded vibrations of the cylinder of beam-draught ratio 2.40 The comparison of the numerical results shows that the author's are always higher than the Kumai's as expected. And the comparison of the numerical results with experimental data shows that the Kumai's numerical results have less deviation in case of two-noded vibration, and that, in case of three-noded vibration, the author's numerical results are in fairly good correspondence.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

A Study on the Wearing Satisfaction of Men's Upper Body Correction Underwear

  • Han, Hyun-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.161-168
    • /
    • 2022
  • In this study, a survey on the wearing satisfaction of commercial men's upper body correction underwear was conducted targeting mildly obese men in their twenties, and it was intended to suggest improvement points for the correction underwear. The product used for the study was Adapt's 95 PROBLEM, and 15 subjects were selected as males in their 20s with a BMI of 25-30 (mild obesity). As a result, men's awareness and interest in corrective underwear were low. In the wearing satisfaction survey, 74% of those who answered negatively that it was uncomfortable to wear and take off. In terms of pressure relief, 60% of those who felt the pressure was strong at the beginning, but as time passed, they got used to it and answered that there was no major inconvenience. However, with regard to digestion after a meal, 40% of the subjects felt that the pressure interfered with digestion. There were many deficiencies in terms of functionality, with more than half of those who responded negatively with regard to stuffiness and heat, and many negative opinions regarding sweat absorption and discharge. In the visual section, positive reaction was shown in chest, side waist and front waist correction, and among them, the front waist had the highest score. In conclusion, it seems that functional parts related to heat and sweat must be improved in consideration of the stuffiness and indigestion brought about by excessive pressure for men's upper body correction underwear.