• 제목/요약/키워드: Body area network

검색결과 214건 처리시간 0.023초

Area-Optimized Multi-Standard AES-CCM Security Engine for IEEE 802.15.4 / 802.15.6

  • Choi, Injun;Kim, Ji-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.293-299
    • /
    • 2016
  • Recently, as IoT (Internet of Things) becomes more important, low cost implementation of sensor nodes also becomes critical issues for two well-known standards, IEEE 802.15.4 and IEEE 802.15.6 which stands for WPAN (Wireless Personal Area Network) and WBAN (Wireless Body Area Network), respectively. This paper presents the area-optimized AES-CCM (Advanced Encryption Standard - Counter with CBC-MAC) hardware security engine which can support both IEEE 802.15.4 and IEEE 802.15.6 standards. First, for the low cost design, we propose the 8-bit AES encryption core with the S-box that consists of fully combinational logic based on composite field arithmetic. We also exploit the toggle method to reduce the complexity of design further by reusing the AES core for performing two operation mode of AES-CCM. The implementation results show that the total gate count of proposed AES-CCM security engine can be reduced by up to 42.5% compared to the conventional design.

IEEE 802.15.6 Under Saturation: Some Problems to Be Expected

  • Rashwand, Saeed;Misic, Jelena;Khazaei, Hamzeh
    • Journal of Communications and Networks
    • /
    • 제13권2호
    • /
    • pp.142-148
    • /
    • 2011
  • Because currently available wireless technologies are not appropriate for wireless body area networks (WBANs), the IEEE 802.15.6 standard was introduced by the IEEE 802.15.6 Task Group to satisfy all the requirements for a monitoring system that operates on, in, or around the human body. In this work, we develop an analytical model for evaluating the performance of an IEEE 802.15.6-based WBAN under saturation condition and a noisy channel. We employ a three-dimensional Markov chain to model the backoff procedure as specified in the standard. Probability generating functions (PGFs) are used to compute the performance descriptors of the network. The results obtained from the analytical model are validated by simulation results. Our results indicate that under saturation condition, the medium is accessed by the highest user priority nodes at the vast majority of time while the other nodes are starving.

무선 인체 네트워크에서의 계산 효율과 에너지 효율 향상을 위한 시스테매틱 네트워크 코딩 (Systematic Network Coding for Computational Efficiency and Energy Efficiency in Wireless Body Area Networks)

  • 김대혁;서영주
    • 한국통신학회논문지
    • /
    • 제36권10A호
    • /
    • pp.823-829
    • /
    • 2011
  • 최근 무선 인체 네트워크 (WBAN)는 유비쿼터스 헬스케어 시스템에의 활용으로 주목 받고 있다. WBAN에서는 인체에 부착 되거나 이식되는 센서 노드와 PDA와 같은 휴대용 개인 베이스 스테이션 (BS)의 에너지 제약이 있고, 이 장치들의 제한된 계산 능력과 메모리 때문에 노드들이 수행하는 계산의 복잡도를 최대한 줄여야만 한다. 또한 생체 신호를 다루기 때문에 신뢰성 있는 데이터 전송이 필수적이다. 본 논문에서는 네트워크 코딩 오버헤드를 줄이고 에너지 효율을 높이기 위해 WBAN을 위한 시스테매틱 (systematic) 네트워크 코딩 기법을 제안한다. 제안하는 시스템을 마코프 체인 (Markov chain)을 이용해 모델링 하고 모든 노드가 BS로의 데이터 패킷 전송을 완료하는데 까지 소모되는 에너지를 최소화 하는 것을 최적화 문제로 정의 하였다. 다양한 환경에서 시뮬레이션을 수행 한 결과 기존의 전송 방법과 비교 했을 때 에너지 효율을 얻는 것을 보였다. 또한 기존의 WBAN에서의 네트워크 코딩의 디코딩 과정 보다 계산 복잡도가 낮아 네트워크 코딩으로 인한 계산 오버헤드를 줄였다.

Towards Key Issues of Disaster Aid based on Wireless Body Area Networks

  • Liu, Jianqi;Wang, Qinruo;Wan, Jiafu;Xiong, Jianbin;Zeng, Bi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권5호
    • /
    • pp.1014-1035
    • /
    • 2013
  • With recent advances in wireless communication and low-power miniaturized biomedical sensor and semiconductor technologies, wireless body area networks (WBAN) has become an integral part of the disaster aid system. Wearable vital sign sensors can track patients' status and location, thus enhancing disaster rescue efficiency. In the past few years, most of the literatures in the area of disaster aid system based on WBAN have focused on issues concerning wireless sensor design, sensor miniaturization, energy efficiency and communication protocols. In this paper, we will give an overview of disaster aid, discuss about the types of network communication as well as outline related issues. We will emphasize on analyzing six key issues in employing the disaster aid system. Finally, we will also highlight some of the challenges that still need to be addressed in the future in order to help the disaster aid system be truly and widely accepted by the public.

Estimating aquifer location using deep neural network with electrical impedance tomography

  • Sharma, Sunam Kumar;Khambampati, Anil Kumar;Kim, Kyung Youn
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.982-990
    • /
    • 2020
  • Groundwater is essential source of the freshwater. Groundwater is stored in the body of the rocks or sediments, called aquifer. Finding an aquifer is a very important part of the geophysical survey. The best method to find the aquifer is to make a borehole. Single borehole is not a suitable method if the aquifer is not located in the borehole drilled area. To overcome this problem, a cross borehole method is used. Using a cross borehole method, we can estimate aquifer location more precisely. Electrical impedance tomography is use to estimate the aquifer location inside the subsurface using the cross borehole method. Electrodes are placed inside each boreholes and area between these boreholes are analysed. An aquifer is a non-uniform structure with complex shape which can represented by the truncated Fourier series. Deep neural network is evaluated as an inverse problem solver for estimating the aquifer boundary coefficients.

OSEK/VDX 표준과 CAN 프로토콜을 사용한 차체 네트웍 시스템 개발 (Development of a Body Network System with GSEK/VDX Standards and CAN Protocol)

  • 신민석;이우택;선우명호;한석영
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.175-180
    • /
    • 2002
  • In order to satisfy the requirements of time reduction and cost saving for development of electronic control systems(ECU) in automotive industry, the applications of a standardized real-time operating system(RTOS) and a communication protocol to ECUs are increased. In this study, a body control module(BCM) that employs OSEK/VDX(open system and corresponding interfaces for automotive electronics/vehicle distributed executive) OS tour the RTOS and a controller area network(CAN) fur the communication protocol is designed, and the performances of the system are evaluated. The BCM controls doors, mirrors, and windows of the vehicle through the in-vehicle network. To identify all the transmitted and received control messages, a PC connected with the CAN communication protocol behaves as a CAN bus emulator. The control system based upon in-vehicle network improves the system stability and reduces the number of wiring harness. Furthermore it is easy to maintain and simple to add new features because the system is designed based on the standards of RTOS and communication protocol.

WBAN 기반의 의료용 게이트웨이 구현에 관한 연구 (A Study on the Implementation of WBAN-Based Medical Gateway)

  • 박용민
    • 한국항행학회논문지
    • /
    • 제18권6호
    • /
    • pp.640-647
    • /
    • 2014
  • WBAN 기술은 3 m 이내에 위치한 인체 내부 및 외부 디바이스들을 무선으로 연결하는 근거리 무선통신 기술이다. WBAN 기반의 센서 네트워크를 지원하기 위해서는 WBAN 미들웨어 및 응용서비스를 위한 핵심 기술의 개발이 필요하다. 환자의 생체 정보를 수집하기 위한 장치로는 한백전자에서 출시된 zigbex를 사용하였으며 생체 정보를 수집하기 위한 메시지 구조로 바이오 모듈 메시지를 제안하였다. WBAN 환경을 위한 게이트웨이 설계 및 구현을 위하여 한백전자의 임베디드 시스템인 HBE-empos II를 사용하였으며 WBAN 네트워크를 위한 BNC와 BN를 구현하기 위해서 HBE-ubi-zigbex를 사용하였다. 마지막으로 제안한 센서 게이트웨이를 사용하여 다른 네트워크와 연동이 가능함을 확인 하였다.

The Medical Bed System for Preventing Pressure Ulcer Using the Two-Stage Control

  • Kim, Jungae;Lee, Youngdae;Seon, Minju;Lim, Jae-Young
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.151-158
    • /
    • 2021
  • The main cause of ulcer is pressure, which starts to develop when the critical body pressure (32mmHg) is exceeded, and when the critical time elapses, ulcer occurs. In this study, the keyboard mechanism of the medical bed with 4 bar links was adopted, and each key can be controlled vertically. A key has one servo drive and one sensor controller which hasseveral body pressure sensors. The sensor controllers and the servo drives are connected to the main controller by two CAN (Car Are Network) in series, respectively. By reading the maximum body pressure value of each keyboard sensor, and by calculating the error value based on the critical body pressure, the fuzzy controller moves each key so that the total error becomes zero. If the fuzzy controller fails, then it prevents ulcer by lifting and lowering the keys of the bed alternatively within a short time. Thus, the controller operates in two-stage. The validity and effectiveness of the proposed approach have been verified through experiments.

A Low-Profile Dipole Array Antenna with Monopole-Like Radiation for On-Body Communications

  • Tak, Jinpil;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • 제15권4호
    • /
    • pp.245-249
    • /
    • 2015
  • In this paper, a low-profile dipole array antenna with monopole-like radiation for on-body communications is proposed. The proposed antenna, operating in the industrial, scientific, and medical (ISM) band, is designed with consideration of the human body effect. By placing eight planar dipole antenna elements symmetrically around the z-axis, the proposed antenna achieves monopole-like radiation characteristics with a low profile. The antenna has overall dimensions of $0.44{\lambda}_0{\times}0.44{\lambda}_0{\times}0.013{\lambda}_0$ at 2.45 GHz in the ISM 2.45 GHz band (2.4-2.485 GHz) and a 10-dB return loss bandwidth of 4.9% ranging from 2.4 to 2.52 GHz.