• Title/Summary/Keyword: Body Surface Temperature

검색결과 405건 처리시간 0.031초

미분화된 신체형 장애 위증(痿證) 환자에 대한 증례보고 (A Case Report of Undifferentiated Somatoform Disorder, Wei Symptom Patient)

  • 김윤주;강재희;조은;곽규인;이현
    • Journal of Acupuncture Research
    • /
    • 제30권5호
    • /
    • pp.193-201
    • /
    • 2013
  • Objectives : This is a case report about undifferentiated somatoform disorder, Wei symptom patient Methods : The patient was treated using acupuncture, electroacupuncture, pharmacopuncture, herbal medication and Korean medical physical therapy. The recovery of this patient had measured in physical examination, gait condition test, body surface temperature, body perimeter and sensory test by dermatome. Results : Through this treatment, the patient's leg elevation angle, body surface tempreature, body perimeter was raised, Rt. lower limb numbness and gait condition had improved. Conclusions : Korean medical therapy including acupuncture, electroacupuncture, pharmacopuncture, herbal medication and Korean medical physical therapy was effective to improve undifferentiated somatoform disorder, Wei symptom patient.

옥상녹화가 PV모듈 발전량에 미치는 영향 고찰 (A study on the effect that the green roof has on the performance of PV module)

  • 유동철;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.113-119
    • /
    • 2012
  • This study aims to examine the effect of the combined application of green roof and PV system on the PV efficiency by measuring the temperature and performance of PV module in order to reduce the temperature on the roof using roof planting system and determine the potential of efficient increase in solar-light power generation. In the experimental methodology, either monocrystalline or polycrystalline PV module was installed in green roof or non-green roof, and then the surface temperature of PV was measured by TR-71U thermometer and again the performance, module body temperature, and conversion efficiency were measured by MP-160, TC selector MI-540, and PV selector MI-520, respectively. As a result, the average body temperature of monocrystalline module was lower by $6.5^{\circ}C$ in green roof than in non-green roof; that of polycrystalline module was lower by $8.8^{\circ}C$ in green roof than in non-green roof. In the difference of generation, the electricity generation of monocrystalline module in green roof was 46.13W, but that of polycrystalline module was 68.82 W, which indicated that the latter produced 22.69W more than the former.

운동에 의한 열 스트레스하에서 흡한속건성 소재 운동복 착용시의 온열생리적 반응 및 주관적 감각 (Thermophysiological Responses and Subjective Sensations when Wearing Clothing with Quickly Water-Absorbent and Dry Properties Under Exercise-Induced Heat Strain)

  • 이소진;박신정
    • 한국의류산업학회지
    • /
    • 제8권3호
    • /
    • pp.349-356
    • /
    • 2006
  • The purpose of this study was to compare the thermophysiological responses and subjective sensations of clothing materials with different water transfer property investigated in exercising and resting subjects at an ambient temperature of $20^{\circ}C$ and a relative humidity of 40%. Two kinds of clothing ensemble were tested: 100% cotton with highly water-absorbent but slowly dry properties(C) and 100% polyester with quickly water-absorbent and dry properties by four capillary channels(QADP). Seven apparently healthy male participants each undertook two series of experiments comprised 10-min of rest, 20-min of exercise with 70% of $VO_{2max}$ on a treadmill and 20-min of recovery. Mean skin temperature was significantly lower in QADP than in C during exercise and recovery. Clothing microclimate temperature was significantly lower in QADP during exercise and clothing surface temperature was also lower in QADP especially during recovery. Also, clothing surface humidity was significantly higher in QADP after the later half of exercise. The concentration of blood lactic acid tended to decrease to a lower level at recovery 3 minutes when wearing QADP rather than C clothing ensemble. Metabolic energy was marginally significantly less during the second half of exercise in QADP. Body mass loss tended to be greater in C than in QADP. The participants had better scores in thermal sensation, comfortable sensation and wetness in QADP during exercise and recovery. These results show that functional materials with quickly water-absorbent and dry properties can alleviate heat strain and induce more comfortable clothing microclimates and subjective sensations in the exercise-induced hyperthermia.

불균등 복사공간의 쾌적온도범위 설정에 관한 연구 (A Study on the Establishment of the Optimal Temperature Limits for Man's Thermal Comfort in an Asymmetric Radiant Space)

  • 손장열;공성훈;윤용진
    • 대한설비공학회지:설비저널
    • /
    • 제14권3호
    • /
    • pp.187-199
    • /
    • 1985
  • The low-temperatured radiant heating System like a panel heating system is recognized as nice means to make comfortable indoor environment. Perhaps, 'Ondol' would be a typical example of the Panel heating system. Nevertheless. Occupants in a radiantly heated Space which has an asymmetric radiant field may feel thermally discomfort due to the asymmetric radiation. The aim of this Study is to suggest the fundamental technical data for establishing Standards of thermally comfortable environment when designing a radiant heating System. Thermal distribution of indoor environment and the skin temperature of the occupants were measured at experimental room in KIER (Korea Institute of Energy and Resources). Whole/Regional thermal and comfort Sensation votes of the occupants were taken simultaneously in order to investigate the relationships between thermal environmental factor and the occupants' responses. The effect of an asymmetric radiation on thermal environment and the occupants' responses was analyzed by using a v.r.t.(vector radiant temperature). By this means, the thermally neutral limits for the ambient air temperature and the floor surface temperature by the occupants' responses were Obtained. And the recommended temperature limits of the indoor surface were derived from the experimental work and the theory of radiant and will provide thermal neutrality for man without any discomfort on the part of the body.

  • PDF

Review, Assessment, and Learning Lesson on How to Design a Spectroelectrochemical Experiment for the Molten Salt System

  • Killinger, Dimitris;Phongikaroon, Supathorn
    • 방사성폐기물학회지
    • /
    • 제20권2호
    • /
    • pp.209-229
    • /
    • 2022
  • This work provided a review of three techniques-(1) spectrochemical, (2) electrochemical, and (3) spectroelectrochemical-for molten salt medias. A spectroelectrochemical system was designed by utilizing this information. Here, we designed a spectroelectrochemical cell (SEC) and calibrated temperature controllers, and performed initial tests to explore the system's capability limit. There were several issues and a redesign of the cell was accomplished. The modification of the design allowed us to assemble, align the system with the light sources, and successfully transferred the setup inside a controlled environment. A preliminary run was executed to obtain transmission and absorption background of NaCl-CaCl2 salt at 600℃. It shows that the quartz cuvette has high transmittance effects across all wavelengths and there were lower transmittance effects at the lower wavelength in the molten salt media. Despite a successful initial run, the quartz vessel was mated to the inner cavity of the SEC body. Moreover, there was shearing in the patch cord which resulted in damage to the fiber optic cable, deterioration of the SEC, corrosion in the connection of the cell body, and fiber optic damage. The next generation of the SEC should attach a high temperature fiber optic patch cords without introducing internal mechanical stress to the patch cord body. In addition, MACOR should be used as the cell body materials to prevent corrosion of the surface and avoid the mating issue and a use of an adapter from a manufacturer that combines the free beam to a fiber optic cable should be incorporated in the future design.

DITI를 통한 불임여성의 체열에 대한 연구 (Correlation between Women Infertility and DITI)

  • 김혜원;김용석;이경섭
    • 대한한방체열의학회지
    • /
    • 제1권1호
    • /
    • pp.52-56
    • /
    • 2002
  • Causes of infertility include a wide range of physical, as well as emotional factors. In Oriental medicine, women's infertility is believed to be caused by the deficiency of the Chung and Ren vessel. Then the Kidney Qi is collapsed and cold. Many infertility women complain the cold hypersensitivity and/or body coldness, especially on the lower abdomen, back and knee. The aim of this study is to examine the interrelationship between infertility and body surface temperature. The 25 infertility women were allocated as infertility group and 25 fertility women (experienced delivery or pregnancy), as control group at the Kangnam Korean Hospital, KyungHee University, Seoul, Korea, from April to December 2000. Thermographic observations for this study were made using the Dorex DITI on 3 different areas's cold hypersensitivity: lower abdomen, back and knee. All data were coded for computer analysis and significances were tested by Mann-Whitney Test. The mean ${\Delta}T$ for abdomen cold hypersensitivity was $0.25{\pm}1.77^{\circ}C$ On control group and $1.00{\pm}0.39^{\circ}C$, infertility group. The mean ${\Delta}T$ for back cold hypersensitivity was $1.75{\pm}0.40^{\circ}C$ on control group and $1.21{\pm}0.58^{\circ}C$, infertility group. The mean ${\Delta}T$ for knee cold hypersensitivity was $0.65{\pm}0.70^{\circ}C$ on control group and $1.32{\pm}0.58^{\circ}C$, infertility group. It was revealed that the cold hypersensitivity on the lower abdomen, back and knee are significantly inter-related to the women infertility. These results do not conflict with the view of Oriental medicine. According to the above results, it is concluded that the body surface temperature, cold hypersensitivity and/or body coldness, have a great effect on women infertility.

  • PDF

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

다양한 성형법으로 제조된 인공 골재의 특성 (Characterization of Artificial Aggregates Fabricated by Using Various Forming Methods)

  • 강승구
    • 한국세라믹학회지
    • /
    • 제46권1호
    • /
    • pp.94-101
    • /
    • 2009
  • The physical properties of artificial aggregates made from clay and inorganic wastes with poor plasticity depends largely on forming method. The artificial aggregates composing of coal fly ash, stone sludge and clay were fabricated using 4 different forming methods and those physical properties were comparatively analyzed. The surface of aggregates made through the extrusion forming process was dense and smooth but was rough for the aggregates obtained by crushing a tile-shaped green body. The aggregates made by pelletizing process had a weak green strength and bumpy surface. The shell generated at surface during a high temperature sintering process induced the most aggregates to be bloated due to a dense shell. But the aggregates made through pelletizing process with dense surface layer showed no significant change in bulk density with sintering temperatures. The water absorption of aggregates decreased with sintering temperature, and that of pelletized specimen was standing $1.8{\sim}2.2$ times higher than that of made by other forming methods. It is concluded that the aggregates having various properties could be fabricated from one batch by using different forming methods.

MEMS 기반 흑체 시스템의 온도 균일도 및 추정 정확도의 수치 해석적 검토 (Numerical Investigation of Temperature Uniformity and Estimation Accuracy for MEMS-based Black Body System)

  • 채봉건;김태규;이종광;강석주;오현웅
    • 한국항공우주학회지
    • /
    • 제44권5호
    • /
    • pp.455-462
    • /
    • 2016
  • 적외선 검출기와 같은 우주용 영상센서는 작동 유무 및 시간경과에 따라 센서의 응답특성이 변하기 때문에 영상품질이 저하된다. 이러한 영상센서의 비균일 응답특성을 보정하기 위하여 궤도상에서 보정용 흑체시스템을 이용하여 주기적인 보정을 실시 할 수 있도록 해야 한다. 본 논문에서는 저온에서 고온에 이르는 다양한 기준온도에서의 높은 온도균일도 확보 및 흑체의 대표표면온도 추정이 용이하고, 초경량, 저전력, 고정밀도의 흑체 시스템을 구현하기 위해 MEMS(Micro Electro Mechanical Systems)기반의 흑체시스템을 제안하였으며, 열해석을 통해 성능을 입증하였다.

인공 체액 조건에서 임플랜트용 티타늄 소재의 부식 특성 (Corrosion Behavior of Titanium for Implant in Simulated Body Fluids)

  • 이중배;최기열
    • 한국표면공학회지
    • /
    • 제37권2호
    • /
    • pp.110-118
    • /
    • 2004
  • The corrosion of pure titanium (CP- Ti Grade 2) and titanium alloy (Ti6Al4V ELI) were studied under various conditions of simulated body fluids. The static immersion test and the electrochemical test were performed in accordance with ISO 10271 : 2001. For the electrochemical test, the open circuit potential was monitored as a function of time, and the cyclic polarization curve was recorded. The corrosion resistance was evaluated from the values of corrosion potential, passivation current density, breakdown potential, and the shape of hysteresis etc. The effects of alloy type, surface condition, temperature, oxygen, and constituents in the fluids such as acid, chloride were estimated. Both specimens had extremely low dissolution rate in the static immersion test. They showed strong passivation characteristics in the electrochemical test. They maintained negligible current density throughout the wide anodic potential range. The passive layer was not broken up to 2.0 V (vs. SCE). The hysteresis and the shift of passivation potential toward the anodic direction was observed during the reversed scan. The passivation process appeared to be accelerated by oxygen in air or that dissolved in the fluids. The passivation also proceeded without oxygen by the reaction of constituents in the fluids. Acid or chloride in the fluids, specially later weakened the passive layer, and then induced higher passivation current density and less shift of passivation potential in the reversed scan. CP-Ti Grade 2 was more reactive than Ti6Al4V ELI in the fluids containing acid or chloride, but thicker layer produced on its surface provided higher corrosion resistance.