• Title/Summary/Keyword: Body Signal

Search Result 865, Processing Time 0.023 seconds

Sound Synthesis of Gayageum by Impulse Responses of Body and Anjok (안족과 몸통의 임펄스 응답을 이용한 가야금 사운드 합성)

  • Cho Sang-Jin;Choi Gin-Kyu;Chong Ui-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.102-107
    • /
    • 2006
  • In this paper, we propose a method of a sound synthesis of Korean plucked string instrument, gayageum, by physical modeling which use impulse responses of body and Anjok. Gayageum consists of three kinds of systems: string, body, and Anjok. These are a serial combination of linear time invariant systems. String can be modeled by digital delay line. Body and Anjok can be estimated by their impulse responses. We found three resonance frequencies in the body impulse response, and implemented resonator as body. Anjok was implemented as high pass filter in fundamental frequency band of gayageum. RMSEs of synthesized sounds are distributed from 0.01 to 0.03. It was difficult to distinguish the resulting synthesized sounds from the originals sound by ear.

  • PDF

Development of an Automatic Body Temperature Measuring System for Dairy Cattle (젖소의 자동 체온 측정 시스템 개발)

  • 정길도;김형주;김용준;한병성;김명순
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.140-143
    • /
    • 1996
  • In this paper the development of an automatic body temperature measuring system which can be attached to the milking machine has been studied. Since the disease is highly related to the body temperature of the cattle, early detection of the abnormal temperature would prevent the severe problems which may occur in dairy farms. The electronic component AD590 is used as a temperature sensor for the system. The device is highly robust against the noise since the output signal is the current. So it can be applied to the long distance sensing. The resolution of the signal is $0.1{\circ}C$ and the current is 10 mV. Also the A/D converter is designed for interfacing the sensor with a computer. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of the dairy cattle properly.

  • PDF

5-body dynamics in the Kepler-47 exoplanetary system: Predicting stable orbits of a third circumbinary planet

  • Hinse, Tobias Cornelius
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.83.1-83.1
    • /
    • 2014
  • Kepler-47 is the first multi-body circumbinary planetary system detected by the Kepler space telescope. The two planets were detected by the transit method. In the discovery paper the authors report about the presence of an additional transit-like signal in their dataset which cannot be explained by a four-body (binary + 2 planets) system. Therefore it is likely that the unexplained signal could be due to a third planet. In this talk I will present recent results from a dynamical investigation of the five-body system (binary + 3 planets). We have applied the MEGNO technique to detect regions of quasi- or near quasi-periodic orbits of a hypothetical third planet. Quasi-periodic regions exists for a third planet and the long-term stability has been tested. Although the existence of a third planet is most likely to be confirmed from transit photometry we calculate transit-timing variation (TTV) signals due to the third planet which also can be used to infer its presence.

  • PDF

[발표취소] Stable 5-body orbits in the Kepler-47 exoplanetary system: Predicting stable orbits of a possible third circumbinary planet

  • Hinse, Tobias Cornelius
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.81.1-81.1
    • /
    • 2014
  • Kepler-47 is the first multi-body circumbinary planetary system detected by the Kepler space telescope. The two planets were detected by the transit method. In the discovery paper the authors report about the presence of an additional transit-like signal in their dataset which cannot be explained by a four-body (binary + 2 planets) system. Therefore it is likely that the unexplained signal could be due to a third planet. In this talk I will present recent results from a dynamical investigation of the five-body system (binary + 3 planets). We have applied the MEGNO technique to detect regions of quasi- or near quasi-periodic orbits of a hypothetical third planet. Quasi-periodic regions exists for a third planet and the long-term stability has been tested. Although the existence of a third planet is most likely to be confirmed from transit photometry we calculate transit-timing variation (TTV) signals due to the third planet which also can be used to infer its presence.

  • PDF

An Analysis of the Vibration Characteristics through the Human Body (인체 내부에서의 진동 전달특성 분석)

  • 전종원;진용옥
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.59-65
    • /
    • 2000
  • This paper describes the analysis of vibration characteristics through the human body as the research for voice therapy and diagnosis. The oscillation signal is not external forces but the self-voice to be pronounced the vowels ('a', 'e', 'i', 'o', 'u'). The experiment system consists of microphones, accelerometers and amplifiers. The input data are stored by the computer. At the same time, the voice is stored by the microphone and the vibration signal of the human body is stored by accelerometer. The 63 points are appointed in head, neck, trunk of human body. The positions and number of times are changeable by the purpose. The analysis parameters are amplitude, phase, fundamental. frequency, formant and the correlation of vibration signal and voice is measured by coherence function. The results show that the vibration signals have characteristic vibration in the positions of human body.

  • PDF

A Study on the Analysis of Posture Balance Based on Multi-parameter in Time Variation (시간변화에 따른 다중파라미터기반에서 자세균형의 분석 연구)

  • Kim, Jeong-Lae;Lee, Kyoung-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.151-157
    • /
    • 2011
  • This study analyzed the posture balance of time variation for exercising body a period of time. Posture balance measured output values for the posture balance system of body moving in the multi-parameter. Posture moving variation had three methods such as open and closed eye, head moving and upper body moving. There were checked a parameter that measured vision, vestibular, somatosensory, CNS. This system was evaluated a data through the stability. This system has catched a signal for physical condition of body data such as a data acquisition system, data signal processing and feedback system. The output signal was generated Fourier analysis that using frequency of 0.1Hz, 0.1-0.5Hz, 0.5-1Hz and 1Hz over. The posture balance system will be used to support assessment for body moving the posture balance of time variation. It was expected to monitor a physical parameter for health verification system.

The Nonlinear Simulation on the Selection of Suitable Suspension Considering Human Vibration (인체 진동을 고려한 최적 현가장치의 선정에 관한 비선형 모의실험)

  • 김진기;홍동표;최만용
    • Journal of KSNVE
    • /
    • v.10 no.2
    • /
    • pp.247-253
    • /
    • 2000
  • The evaluation of the ride quality had been performed by the subjective method before ISO2631(International Organization for Stadard 2631) and BS6841(British Standard 6841) was precented, but many research programs have been performed by the objective method after that. On this study, the ride quality was evaluated related with the objective method which considered the vibration which the human body feels on the driver's seat while driving on the road. In particular, we made the shock absorber nonlinear model and also selected the suitable shock absorber in the part of the vibration which the human body feels into the simulation. The shock absorber of suspension was dealt with 3 cases respectively with the front wheel and rear wheel. The vibration of the car driving on the road can be transferred to the wheel, the suspension, the vehicle body, the seat and the human body. The signal which was gained from the seat(hip) and the floor(foot) of the human body was changed to the vibration signal which the human body felt through using the frequency weighting function. And then the performance of the shock absorber was calculated through the statistic processing.

  • PDF

Channel Characterization and Transmission Efficiency Analysis of Wireless Body Area Network (WBAN 채널 특성과 전송 효율 분석)

  • Ahn, Byoung-Jik;Song, Seong-Moo;Kim, Sun-Woo;Choi, Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.985-994
    • /
    • 2012
  • This paper presents the real channel measurements and investigates their statistical characterization in wireless body area network(WBAN). In on-/off body channel, the measurements are performed with some representative human movements for considering human movements. Moreover, three signal transmission schemes with outage constraint are studied for getting total power consumption in each transmission scheme. Using the real channel measurements, between theoretical and realistic simulation are compared. This paper shows that power efficiency is improved through cooperative communication, and how much position of sensor node and human movement affect signal transmission power.

Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation (독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출)

  • Jeon, Hak-Jae;Kim, Jeong-Do;Lim, Seung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.