• Title/Summary/Keyword: Body Protector

검색결과 37건 처리시간 0.019초

Relationship between the Impact Value of Electronic Body Protector and the Impact Force of Force Platform in the Taekwondo (태권도의 전자호구 충격값과 포스플랫폼 충격력과의 관련성)

  • Bae, Young-Sang
    • Korean Journal of Applied Biomechanics
    • /
    • 제23권2호
    • /
    • pp.125-130
    • /
    • 2013
  • Although the electronic body protector has been officially adopted by the World Taekwondo Federation(WTF) in 2006, no scientific information is available about the reliability of its performance. The purpose of this study, therefore, was to investigate the relationship between the impact value of electronic body protector and the impact force of force platform. Male collegiate Taekwondo athletes([MCTA], n=21) and male collegiate Taekwondo students([MCTS], n=20) volunteered to participate in the study. Each subject performed the apchagi, dollyeochagi and dwichagi on the force platform and the electronic body protector. At the apchagi, it showed that MCTS(about 4,700 N) generated more maximum kick force than MCTA(about 3,900 N), but it expressed that MCTA(about 5,300 N) generated more maximum kicking force than MCTS(about 4,400 N) at the dwichagi. At the apchagi and the dwichagi, it indicated the high coefficient of correlation(over r=.8) which supports higher explanation force the relationship between the impact value of electronic body protector and the impact force of force platform, but there was no statistically significant difference at the dollyeochagi.

Research on Impact Sensors for Developing the Electronic Body Protector of Taekwondo (태권도 전자호구 개발을 위한 충격감지 센서 연구)

  • Ki, Jae-Sug;Jeong, Dong-Hwa;Lee, Hyun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제20권4호
    • /
    • pp.648-655
    • /
    • 2019
  • This paper proposes the differential development of a Taekwondo electronic body protector. For this development, the most suitable sensor system was selected after analyzing and testing various sensor methods (magnetic sensors, electric capacity sensors, contact switch sensors, and piezo-film sensors) that could be applied in the electronic body protector, the selected sensors were distributed to the body and feet to make a more precise hit score, unlike the existing system in which all sensors are centralized on the body. Furthermore, it aims to illuminate using a lightweight film-type piezoelectric sensor on the body protector. In the case of an existing electronic body protector, all sensors and network device were concentrated on the body protector, so users need to purchase a set if they want it. On the other hand, the proposed system cloud can be used individually using a smart scoring WEP program. The effects of decreasing weight by up to 20% were compared with those of the existing system. Setting up a test facility is very difficult, so more study will be needed to analyze the effects of a hit.

Wearing Characteristic Evaluation of Hip Protector for Hip Fracture Prevention (고관절 골절 예방을 위한 힙프로텍터 착용특성 평가)

  • Jeon, Eun-Jin;Park, Sei-Kwon;You, Hee-Cheon;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • 제16권6호
    • /
    • pp.1001-1007
    • /
    • 2014
  • We surveyed the wearing characteristics of hip protectors. The problems of existing hip protectors were identified and the directions for improvement were presented. The evaluation of wearing characteristics was conducted on the 100 elderly women (60 to 85 years) with 5 types of hip protector. The questionnaire was composed of history and characteristics on falling, hip protector acceptance, preference, use characteristics and improvement requirements. The result of wearing characteristic evaluation indicated that 52% of the subject experienced falling in winter. Incidents resulting from falling occurred: outdoors (74.5%), bathroom (10.9%), and kitchen (5.5%). Body parts to be protected were in several areas: 35.6% for lumbar, 26.9% for hip joint, and 15% for hip bone. Participants prefer a belt B type design at a rate of 56.9% because it provided a sense of stability by clinging to the body and upholding the waist. Belt B type was the most appropriate in terms of fit, allowance, mobility, and design except pad thickness. To reduce the risk of hip fracture, hip protector needs to be designed in consideration of user's type of fall and body shape. The pattern and size of a hip protector has to be improved in regards to the amount of discomfort. An objective evaluation is needed for the ergonomic design of a hip protector based on and analysis of 3D body image of the elderly and the shock-absorbing quality of pad.

Development of a Sizing System and a Draping Pattern for Hip Protector based on 3D Data Analysis of Korean Older Women (한국 노인의 3D 인체특성 분석을 통한 Hip protector 치수체계 수립 및 입체패턴 설계)

  • Jeon, Eun-Jin;Park, Sei-Kwon;You, Hee-Cheon;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • 제18권1호
    • /
    • pp.120-129
    • /
    • 2016
  • This study aimed to develop an optimal sizing system and a draping pattern for hip protector based on an analysis of anthropometric characteristics of Korean older women. A hip protector is a specialized form of pants or underwear containing pads along the outside of each hip. The 3D body scan data of Korean older women were analyzed to identify their anthropometric characteristics and a four-size system with 93% of population accommodation was developed by clustering analysis based on key dimensions derived from factor analysis. The sizing system consists of small/short, large/short, small/tall, and large/tall. A 3D physical model and hip pads were fabricated; then, a hip protector was draped on the 3D model and hip pads. The sizing system of hip protector was analyzed in terms of size and shape and a draping pattern was compared on back center, back side, front side, front center and pad. Lastly, the pattern deformation and clothing pressure were analyzed using the virtual clothing system CLO. Virtual system have disadvantage of not to suggest the objective value. In the future research the wearing comfort and impact absorption of the hip protector needs to be tested and then a hip protector design will be finalized by considering the hip protector's size, material, comfort testing results, aesthetic appeal, protection effectiveness, and practical utility of everyday use.

Hip Protector Design Process for the Korean Elderly

  • Jeon, Eun-Jin;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • 제18권4호
    • /
    • pp.520-530
    • /
    • 2016
  • This research aims to propose an ergonomic design process for hip protector based on previous studies, existing products, multidisciplinary experts opinion, and wearing test. The elderly are more likely to suffer a hip fracture when they fall due to their physical changes in skeletal form, muscle quantity, bone density, and joint movement. A hip protector is an effective product to prevent hip fractures in the elderly but it also has a problem in that it is uncomfortable. Therefore there is a high chance that it won't be able to prevent hip fractures properly. Since the comfort of a hip protector is one of the most critical elements in preventing a hip fracture, we need to keep improving the hip protector for mobility and usability. Based on the previous studies and limitations of current hip protector products, we need to come up with an optimal design for the Korean elderly. First, knowledge has to be built relating to the ergonomic design of the hip protector considering body shape and size analysis using 3D-scan data, and biomechanical analysis on hip fracture. Second, we need to develop a design process including hip protector pattern design, and wearing evaluation with virtual system. Third, we suggest to reevaluate and verify the design procedure from impact evaluation using testing simulator, virtual evaluation of impact, to wearing comfort and usability evaluation. This design process presented in this study would be expected to contribute to the development of ergonomic hip protector which is suitable for the Korean elderly.

A Suggestion of Sizing System for Developing Taekwondo Protectors (태권도 보호구 치수체계 제안)

  • Yi, Kyong-Hwa;Kim, Hye-Soo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제32권9호
    • /
    • pp.1397-1406
    • /
    • 2008
  • This research was to develop Taekwondo trunk protector(Hogu) and head protector's sizing systems corresponding the regulations by World Taekwondo Association. These sizing systems were established using 2003-2004 Size Korea anthropometric data. The result can be summarized as follows: According to the analysis of correlation, most measurements had high relationship with weight for Hogu and head girth for head protector. Six sizes(47, 54, 59, 64, 70, 76) for Hogu and 4 sizes(52, 54, 56, 60) for head protector were suggested in this study. Hogu sizes indicate body weights and head protector sizes express head girth measurements. By the comparison between current Hogu sizes and new sizes, the smaller sizes of new Hogu were bigger than current sizes in bust girth, back fastening length, shoulder length. On the other hand, the bigger sizes of new Hogu were larger than current sizes in bust girth, back fastening length, shoulder length. In addition, new Hogu's lengths were shorter than current Hogu in all sizes. The lengths of Neck to collar bone in new Hogu sizes were longer than current Hogu. In case of the head protector, there were no measurements besides outer circumference of helmet in recognized specifications of WTF. Therefore some referable measurements such as head girth, head length, bitragion arc, sagital arc were suggested in new size specification. When helmet sizes were suggested, the thickness of the NBR foam also were considered.

Development of Waist Protector Designs for the Elderly -Focusing on Evaluations of Preference and Satisfaction- (고령자를 위한 허리 보호대 디자인 개발 -선호도 및 만족도 평가를 중심으로-)

  • Park, Sujin;Piao, Jiaoli;Han, Ru;Koo, Sumin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제46권2호
    • /
    • pp.199-218
    • /
    • 2022
  • Considering increasing demand for improved waist protectors for the elderly, in this study we sought to design a waist protector that reflects the body characteristics, preferences, and satisfactions of the elderly. A survey conducted to investigate elderly satisfaction with existing waist protectors, as well as their preferences in product function, design, and characteristics, found that consumers are not satisfied with current waist protector offerings and would prefer protectors that allow greater freedom to perform physical activities and that are more easily accessible. Based on the survey, we developed a guideline on function, design, and characteristics, resulting in four new waist protector designs: A and B for men, and C and D for women. Significant preference differences according to gender were reflected in the designs. For example, designs for female waist protectors focused much more on improving tightness, size, freedom of movement, and easy attachment or detachment than designs for male waist protectors did. Evaluation of satisfaction with new designs suggests that new designs meet the satisfaction criteria of elderly consumers, who express willingness to purchase and use them.

Design and Evaluation of a Knee Protector using a 3D Printing Pad (3D 프린팅 패드를 활용한 무릎 보호대의 설계 및 평가)

  • Xi Yu Li;Jung Hyun Park;Jeong Ran Lee
    • Fashion & Textile Research Journal
    • /
    • 제25권2호
    • /
    • pp.221-229
    • /
    • 2023
  • This study aims to develop knee protectors that provide high safety and fitness, while incorporating a motion-adaptable 3D-printed pad. These protectors were evaluated by individuals who experience knee discomfort or pain. The results are as follows. First, the 3Dprinted pad design of a hexagonal mesh structure, which is modeled for excellent appearance and knee movement. Each unit of the mesh has a outer layer of 2mm thick, a spacer layer of 1 mm in diameter, and is connected by a 1.5 mm bridge. The bridge was extended up to 1.2 cm. Second, the knee brace was designed in three types - cylinder, strap, and combination by Universal design. Impact protection measurements of the three knee protectors demonstrated roughly 80% reduction in impact. Third, based on usability evaluation, cylinder type protectors have the highest ratings in most areas, primarily because of their ease of use. The strap type protector received positive reviews in terms of appearance and care, and the combination type provided stable knee protection. This study demonstrated the potential industrial application of 3D printing technology by designing and evaluating protective products for the human body. The results of this study are expected to aid knee protector manufacturers in developing practical products and promoting the development of protective equipment for other body parts or purposes.

Segmental Hard Shell Design of Knee Protector for Children Using 3D Printing (3차원 프린팅을 이용한 어린이용 무릎보호대의 분절형 하드쉘 설계)

  • Lee, Hyojeong;Lee, Yejin
    • Journal of Fashion Business
    • /
    • 제21권4호
    • /
    • pp.116-126
    • /
    • 2017
  • This study applied a segmented hard shell design on knee protectors for children with the objective of increasing mobility. The prototype of the hard shell that does not correspond to movement of the body among components of the knee protector was developed. Surface modeling was conducted based on 3D knee data to enhance comfort through optimized fit on the knee joint where the hard shell would be worn. For this, previous studies on changes in skin near the knee joint during knee flexion were reviewed to establish basic segmental lines. The basic design included six segments, and the number of segments was used as the design variable by increasing or decreasing it to 0, 3, 6, 9, and 14 segments. A prototype was produced from 3D printing with TPU material, worn for wearing assessment. Results revealed fewer numbers of segments resulting in less fit with the body, while actual appearance was stable. Meanwhile, the number of proper segments improved better fit with the body during movement. The wearing assessment revealed the amount of gap reflects change in skin length depending on movement. Assessment results demonstrated basic segment design, S6 with 6 segments, had the best design and most optimized fit. Findings in this study can provide key data for designing knee protection products for children.

Shielding Effect of Radiation Protector for Interventional Procedure (중재적 방사선 분야 방호용구 차폐효과)

  • Ko, Shin-Kwan;Kang, Byung-Sam;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • 제30권3호
    • /
    • pp.213-219
    • /
    • 2007
  • The purpose of this study is to evaluate shielding effect of radiation protector for interventional radiologists in procedures by measuring inside and outside of radiation protector. In this study, we measured the radiation dose of 4 interventional radiologists during TACE and PTBD procedure for 4 month(2005.05-2005.09). Absorbed dose were measured by TLD placed underneath and over radiation protector such as Goggle, Thyroid protector, Apron and placed on the 4th finger of Hand. In addition, we measured background radiation dose in the control room using TLD. During TACE procedure, using 0.07 mmPb Goggle decreased average 53.8% of radiation dose rate in continuous fluoroscopic mode and decreased average 77.6% of radiation dose rate in pulse fluoroscopic mode. Using 0.5 mmPb Thyroid protector decreased average 88.9% of radiation dose rate in continuous fluoroscopic mode and decreased average 92.8% in pulse fluoroscopic mode. During PTBD procedure, using 0.07 mmPb Goggle decreased radiation dose rate average 62.7%, 87.9% by 0.5 mmPb Thyroid protector, 90.5% by 0.5 mmPb Apron. The average fluoroscopic time of PTBD was 6.14 min. shorter than TACE procedure, but radiation exposure dose rate of PTBD was 3 times higher in total body dose, and 40 times higher in hand dose rate than TACE. Interventional radiologists must wear thicker protector recommended over 0.5 mmPb. Also, they must use lead Goggle during interventional procedure. Abdomen dose decreased average 38.4% by drawing a lead curtain under the patient's table, therefore, they must draw a lead curtain to shield scattering ray. Radiation exposure dose decreased average 59.0% by using pulse fluoroscopic mode. So radiologists would better use pulse fluoroscopic mode than continuous fluoroscopic mode to decrease exposure dose.

  • PDF