Characteristic Evaluation of Pressure Mapping System for Patient Position Monitoring in Radiation Therapy

  • Kang, Seonghee;Choi, Chang Heon;Park, Jong Min;Chung, Jin-Beom;Eom, Keun-Yong;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.153-158
    • /
    • 2021
  • Purpose: This study evaluated the features of a pressure mapping system for patient motion monitoring in radiation therapy. Methods: The pressure mapping system includes an MS 9802 force sensing resistor (FSR) sensor with 2,304 force sensing nodes using 48 columns and 48 rows, controller, and control PC (personal computer). Radiation beam attenuation caused by pressure mapping sensor and signal perturbation by 6 and 10 mega voltage (MV) photon beam was evaluated. The maximum relative pressure value (mRPV), average relative pressure value (aRPV), the center of pressure (COP), and area of pressure distribution were obtained with/without radiation using the upper body of an anthropomorphic phantom for 30 minutes with 15 MV. Results: It was confirmed that the differences in attenuation induced by the FSR sensor for 6 and 10 MV photon beams were small. The differences in mRPV, aRPV, area of pressure distribution with/without radiation are about 0.6%, 1.2%, and 0.5%, respectively. The COP values with/without radiation were also similar. Conclusions: The characteristics of a pressure mapping system during radiation treatment were evaluated on the basis of attenuation and signal perturbation using radiation. The pressure distribution measured using the FSR sensor with little attenuation and signal perturbation by the MV photon beam would be helpful for patient motion monitoring.

Investigation of the body distribution of load pressure and virtual wear design of short pants harnesses in flying condition (플라잉 상태에서 바지형태의 하네스에 대한 하중압력 분포 측정 및 가상착의 적용)

  • Kwon, MiYeon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.3
    • /
    • pp.11-21
    • /
    • 2021
  • Virtual reality is currently mainly used in games, but is starting to be applied as a variety of media fields, such as broadcasting and film. Virtual reality provides more fun than reality, and can provide new experiences in areas that cannot be experienced in reality due to the constraints of time, space, and environment. In particular, as the social non-contact arena has increased due to COVID-19, it is being applied to education, health, and medical industries. The contents are further expanding into design and military fields. Therefore, the purpose of this study was to observe the change in distribution of load and pressure felt by the body in the flying state while wearing a short pants harness, which are mainly used in the game and entertainment industry. In the experiment, the average pressure in the flying state was measured by attaching a pressure sensor to the back and front of a human mannequin. As a result, it was confirmed that the load concentrated on the waist in the flying state was 44 N, with a pressure of 1353 kPa. The pressure distribution was concentrated in front of the center of gravity, and was measured was at 98% by the pressure sensors, with an average pressure value of approximately 15 kPa, and a pressure value of approximately 12 kPa at the back, which was measured at 67% by the pressure sensor. The results of the load and pressure distribution measurement are presented as fundamental data to improve the wearability and comfort of harnesses in the future, and are compared to actual measured pressure values by analyzing the clothing pressure in flight through virtual wear of harnesses through the CLO 3D program.

Evaluation of measuring accuracy of body position sensor device for posture correction (자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Kang, Min-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.

Use of Rigid Scattering Body in the use of NAH based on the inverse BEM (역경계요소법에 근거한 근접 음향 홀로그래피에서 강체 산란체의 이용)

  • 김성일;정지훈;이정권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.486-489
    • /
    • 2004
  • The NAH based on the inverse BEM is used to reconstruct the source field, which is advantageous in dealing with the irregular source. In the implementation of this technique, a large number of pressure measurements is required because an over-determined pressure data set is required. These conditions accordingly cause the increase of measurement time and associated effort along with the error due to mal-positioning. The purpose of this study is to reduce such inconveniences: Instead of increasing the number of field pressure data, the number of transfer paths between the source and the receiver is increased by placing rigid scattering body in-between the source and receiver. For validating the usefulness and effectiveness of the method, the numerical analyses of interior problem are demonstrated. As a result, it is thought that the proposed method enables the measurement at smaller number of sensor positions and the monitoring of surface vibration with less experimental effects than before.

  • PDF

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

Analysis and Training Contents of Body Balance Ability using Range of Motion of Lumbar Spine and Center of Body Pressure (요추 관절가동범위와 신체압력중심을 이용한 신체균형능력 분석 및 훈련 콘텐츠)

  • Goo, Sejin;Kim, Dong-Yeon;Shin, Sung-Wook;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.279-287
    • /
    • 2019
  • In this paper, we attempted to analyze the balance ability of the body by measuring changes in body motion and plantar pressure distribution. So we developed a program that can measure and analyze range of motion and center of body pressure using inertial measurement unit(IMU) and FSR(Force Sensing Resistor) sensor, we also produced a contents that can help improve the balance ability. The quantitative values of range of motion and center of body pressure measured by this program are visualized in real time so that the user can easily recognize the results. In addition, the contents were designed to be adjusted according to the direction of improving the balance ability by adjusting the difficulty level based on the measured balance information. This can be achieved by increasing the concentration and participation will by using visual feedback method that proceeds while watching moving objects according to the user's motion.

Development for body temperature sensor and monitoring telemetry system (체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현)

  • Lee, Jyung-Hyun;Seong, Ki-Woong;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

A Multi-tier Based Lying Posture Discrimination Algorithm Using Lattice Type Pressure Sensors Allocation (격자형 압력 센서 배치 구조를 이용한 다층 기반 누운 자세 판별 알고리즘)

  • Cho, Min Jae;Hong, Youn-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.402-409
    • /
    • 2019
  • Patients with dementia or elderly patients who can not move at all by themselves are at a high risk of falls and bedsore due to lack of caregivers. In this paper, to solve this problem, we propose an algorithm to determine the patient's lying postures by discriminating the main body parts such as head, shoulders, and hips based on the pressure intensity sensed at regular intervals. A smart mat with a lattice structure in which a pressure sensor is arranged so that the body part can be discriminated irrespective of the physical characteristics has been implemented. It consists of two modules of $7{\times}7$ array size. Each module consists of 49 FSR-406 sensors and independently senses pressure. For each module, the body part corresponding to the upper body or the lower body is sequentially discriminated by using a pressure distribution such as a cumulative pressure sum using a filter. The proposed algorithm can identify five lying positions by examining the inclusion relationship between body parts belonging to layer-1 such as head, shoulder, and hip area.

Center of Pressure of a Human Body using Force Sensing Resistor (Force Sensing Resistor를 이용한 인체압력중심 변화 분석)

  • Park, Cheol;Park, Shinsuk;Kim, Choong Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1722-1725
    • /
    • 2014
  • An experimental investigation of COP(center of pressure) was performed using FSR(force sensing resistor) and force plate. The FSR sensor system is used as effective device to detect the movement of human body in activities of daily living. It has been shown that the FSR provides the trajectories of COP with repeatability and reliability.

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.