• Title/Summary/Keyword: Bluetooth4.1

Search Result 121, Processing Time 0.02 seconds

Walking Assistance System for Visually Impaired People using Vultiple sensors (다중 센서를 이용한 시각장애인 보행 보조 시스템)

  • Park, Hye-Bin;Ko, Yong-Jin;Lee, Seung-Min;Jang, Ji-Hoon;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.533-538
    • /
    • 2017
  • In this thesis, the ambulatory aid mechanism was implemented so that blind people could be safer at risk of walking outdoors. Using ultrasonic sensors, the obstacles can be detected when the distance between the obstacle is within 50 cm of the obstacle. If the light sensor becomes less than 25 lux, the LED will automatically turn on and help the safety of the visually impaired and the security of sight of the peripheral walkers. Color recognition sensors increase the rate of recognition of yellow color by the detection distance is 1cm, it vibrated when yellow light was detected. Using GPS with 7.3 m of error range, the guardian was able to check the location of the visually impaired.

Design of a Whitening Block Module for Minimizing DC Bias in Wireless Communications (무선 통신에서 DC 바이어스를 최소화하는 화이트닝 블록 설계)

  • Moon, San-Gook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.673-676
    • /
    • 2008
  • In wireless communications such as Bluetooth, Baseband should be able to minimize the DC bias of the data which passed the modem interface of either transmitter or receiver for the reliability of the circuit and the integrity of the data. The transmitter scrambles the data to send randomly to the error correction block and the receiver recovers the randomly spread data as they have been. To design the whitening block, it is important to select the prime polynomial for the filtering. In this paper, we designed a optimal whitening block using the prime polynomial $g(D)=D^7+D^4+1$ for hardware and area efficiency. The proposed hardware whitening block was described and verified using Verilog HDL and later to be automatically synthesized. The synthesized whitening block operated at 40Mhz normal clock speed of the target baseband microcontroller.

  • PDF

The First Korean-Made IT Convergence Electric Skateboard (한국 최초 IT융합 전기스케이트보드)

  • Jung, Sunghun;Youn, Sungwook
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.31-40
    • /
    • 2017
  • The rise of eco-friendly personal electric mobility is a worldwide trend and the first Korean-made IT convergence electric skateboard, Youth Board, is developed to lead the trend. Youth Board is remotely controllable using either Youth Wearable Controller or Youth App through Bluetooth v4.0 communication, can speed up to 25 km/hr, and operating time is approximately 1.5 hr. A LED display located in the front side of Youth Board deck shows three different states to a rider for user convenience: remaining battery SOC, current driving speed, and braking amount. Indoor EMC test results between Youth Board and Youth Wearable Controller and outdoor Youth Board driving test results are analyzed. In particular, driving test results show the maximum current output is about 15% lowered compared to the other competitor electric skateboard and it lessens the power burden of the motor ESC. These results show Youth Board's usefulness as a personal mobility in the sense of small, light, and inexpensive aspects.

Comparing the accuracy of saddle position and traditional position in head-up cardiopulmonary resuscitation (Head-up CPR 시 처치자의 위치에 따른 심폐소생술 정확도 비교)

  • Yoon, Byoung-Gil;Park, Jung-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.2
    • /
    • pp.99-107
    • /
    • 2019
  • Purpose: This study aimed to identify the position for the most accurate head-up cardiopulmonary resuscitation (CPR) by comparing saddle position CPR (SPCPR) and traditional CPR (TCPR). Methods: Sixty certified persons who completed a basic life support provider course between May 1 and June 21, 2019 were enrolled in the study. The participants were asked to perform 2 minutes of CPR, and the depth of chest compression, rate, position, full release, and hands off time were assessed. Accuracy was evaluated based on data collected from a smart phone application connected to the manikin via bluetooth and analyzed using frequency, percentage, t-test, analysis of variance and ${\chi}^2$. Results: The accuracy of chest compression was statistically significantly higher for SPCPR, 63.03%[${\pm}8.75$] for SPCPR and 55.50%[${\pm}10.17$] for TCPR [t=3.074, p=.003]. The depth of chest compression was statistically significantly greater for SPCPR, 4.51cm[${\pm}0.45$] for SPCPR and 4.16cm[${\pm}0.61$] for TCPR [t=2.503, p=.015]. The rate of chest compression was statistically significantly higher for TCPR, 105/min[${\pm}10.79$] for SPCPR and 111/min[${\pm}11.57$] for TCPR [t=-2.008, p=.049]. Accuracy of position of chest compression was statistically significantly higher for SPCPR, 96.10%[${\pm}13.73$] for SPCPR and 79.93%[${\pm}30.34$] for TCPR [t=2.659, p=.011]. Accuracy of full release was higher with SPCPR, with 86.30%[${\pm}30.53$] for SPCPR and 71.10%[${\pm}36.05$] for TCPR, but the difference was not statistically significant [t=1.762, p=.083]. Conclusion: Saddle position CPR was found to be more accurate than TCPR in the performance of manual head-up CPR.

Alignment of Microbeads Using Spinning Helical Minichannel Cartridge (회전하는 나선형 미니채널 카트리지를 이용한 미세입자 정렬)

  • Kim, Subin;Prasad, Bibin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • Separation of particles based on different sizes, detection of pathogenic bacteria and isolation of leukocytes from whole blood are typical applications of spiral or helical microchannels. The present study focuses on developing a CD4+ T-cell counting device for monitoring HIV/AIDS patients with the aid of a helical minichannel used for a sample cartridge. For the experiment, $10{\mu}m$ sized microbeads were used for visualization with a fluorescence imaging system. Alignment of microbeads was investigated in a stationary and spinning sample cartridge filled with glycerol-water mixtures of different densities. The helical minichannel was spun using a DC motor controlled by an Arduino board with a Bluetooth shield. It was found that when the sample cartridge was made stationary, no bead alignment was achieved for a medium with density (0% and 20% glycerol) lower than that of the beads, but when it was spun at 2000-3000 rpm for 1-4 min, an alignment was obtained at the top of the channel facilitating optical detection and enumeration of those microbeads. Since an alignment of microbeads was achieved for a medium with density as that of blood plasma, the same approach can be applied for aligning and counting CD4+ T-lymphocytes in whole blood samples collected from patients.

Design and Implementation of U-Health System for Active Oxygen Measurement Data based on Mobile Phone (활성산소 측정 데이터를 위한 모바일 기반의 U헬스 시스템 설계 및 구현)

  • Lee, Chang Moo;Oh, Seung Kyo;Choi, Deok Jai
    • Smart Media Journal
    • /
    • v.1 no.4
    • /
    • pp.52-58
    • /
    • 2012
  • In recent years the combination of IT and BT for U-Healthcare Medical Services has attracted popular attention as an alternative for solving health problems due to aging issue. Active oxygen as free radicals causes unstable state of the body resulting to other disease on which approximate 90% of the diseases are associated with active oxygen. The severity is even higher along with increasing age. Therefore, there is a need for systematic management of active oxygen saturation for the elderly and chronic patients. In this paper, the data about active oxygen measurements from the body measurement is sent to the data storage of medical facilities by the service provider. Medical information is measured by devices provided complying with the standard, support and information using Bluetooth communication. Users can check their health status themselves using the proposed system through 3G/4G mobile devices like smart phone to medical institutions in which the smart phone act as a gateway for medical data transferred from patient to medical institutions and vice versa. Users can get and experience a diagnosis and effective U-Environmental Health Services from Medical institutions anywhere using the proposed built system.

  • PDF

Development of a Breath Control Training System for Breath-Hold Techniques and Respiratory-Gated Radiation Therapy

  • Hyung Jin Choun;Jung-in Kim;Jong Min Park;Jaeman Son
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.136-141
    • /
    • 2022
  • Purpose: This study aimed to develop a breath control training system for breath-hold technique and respiratory-gated radiation therapy wherein the patients can learn breath-hold techniques in their convenient environment. Methods: The breath control training system comprises a sensor device and software. The sensor device uses a loadcell sensor and an adjustable strap around the chest to acquire respiratory signals. The device connects via Bluetooth to a computer where the software is installed. The software visualizes the respiratory signal in near real-time with a graph. The developed system can signal patients through visual (software), auditory (buzzer), and tactile (vibrator) stimulation when breath-holding starts. A motion phantom was used to test the basic functions of the developed breath control training system. The relative standard deviation of the maxima of the emulated free breathing data was calculated. Moreover, a relative standard deviation of a breath-holding region was calculated for the simulated breath-holding data. Results: The average force of the maxima was 487.71 N, and the relative standard deviation was 4.8%, while the average force of the breath hold region was 398.5 N, and the relative standard deviation was 1.8%. The data acquired through the sensor was consistent with the motion created by the motion phantom. Conclusions: We have developed a breath control training system comprising a sensor device and software that allow patients to learn breath-hold techniques in their convenient environment.

Isolation Enhancement of Internal MIMO Antenna

  • Jung, Pil Hyun;Yang, Woon Geun
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.18-26
    • /
    • 2015
  • In this paper, we proposed and evaluated the performance of an internal MIMO (Multiple Input Multiple Output) antenna for multiband operations including LTE (Long Term Evolution) 700/2300/2500. And to enhance the isolation characteristic, a parasitic element is designed and applied. The proposed single antenna has a volume of $60mm(W){\times}38mm(L)$, and the ground plane is $60mm(W){\times}100mm(L)$. The parasitic element used for enhancing the isolation of the antenna was designed with a copper on FR4 sized $60mm(W){\times}20mm(L){\times}1.6mm(H)$, and the pattern size is $60mm(W){\times}15mm(L)$. Simulated and measured results showed that LTE 700/2300/2500, DCS (Digital Cellular Service: 1710-1880MHz), K-PCS (Korea-Personal Communication Service: 1750-1870MHz), US-PCS (US-Personal Communication Service: 1850-1990MHz), WCDMA (Wideband Code Division Multiple Access: 1920-2170MHz), Wibro (2300-2390MHz), Bluetooth (2400-2483MHz), WLAN (Wireless Local Area Network: 2400-2483.5MHz), US-WiMAX (US-World interoperability for Microwave Access: 2400-2590MHz) frequency bands were covered with $S_{11}$ values less than -6dB (VSWR < 3). Simulated and measured results on $S_{21}$ at 730MHz for the firstly designed MIMO antenna showed -5.50dB and -5.65dB, respectively. When with the parasitic element at the separated ground plane to enhance the isolation performance, -10.33dB and -12.90dB are obtained for the simulation and measurement, so the enhanced isolation performance at lower frequency band (617-867MHz) is confirmed.

PC controlled Autonomous Navigation System for GPS Guided Field Robot (GPS를 이용한 필드로봇의 PC기반 자율항법 제어 시스템)

  • Han, Jae-Won;Park, Jae-Ho;Hong, Sung-Kyung;Ryuh, Young-Sun
    • Journal of Biosystems Engineering
    • /
    • v.34 no.4
    • /
    • pp.278-285
    • /
    • 2009
  • Navigation system is applied in variety of fields including the simple location positioning, autopilot navigation of unmanned robot tractor, autonomous guidance systems for agricultural vehicles, construction of large field works that require high precision and map making process. Particularly utilization of GPS (Global Positioning System) is very common in the present navigation system. This study introduces a navigation system for autonomous field robot that travels to the pre-input path using GPS information. Performance of the GPS- based navigation is highly depended on its receiving rate because GPS receivers do not acquire any navigation information in the period between the refresh intervals. So this study presents an algorithm that improves an accuracy of the navigation by estimation the positional information during the blind period of a low rate GPS receiver. In fact the algorithm calculated the robot's heading in a 50 Hz rate, so the blind period of an 1 Hz GPS receiver is extensively covered. Consequently implementation of the algorithm to the GPS based navigation showed an improvement in guidance accuracy. The conventional field robot directly carried an expensive control computer and sensors onboard, therefore the miniaturization and weight reduction of the robot was limited. In this paper, the field robot carried only communication equipments such as GPS module, normal RC receiver, and bluetooth modem. This enabled the field robot to be built in an economic cost and miniature size.

EA Study on Practical Engineering Education through the Design and Configure of Safe Running Type Drones (안전 주행형 무인기의 설계 및 제작을 통한 실천 공학 교육에 관한 연구)

  • Jo, Yeong-Myeong;Lee, Sang-Gwon;Chang, Eun-Young
    • Journal of Practical Engineering Education
    • /
    • v.9 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • This study will provide a practical plan of engineering education through the study of major activities connected with the production of works to accomplish the graduation conditions by completing the comprehensive design subject and the result of the performance. The designed subject is to measure the minimum safety distance during driving using the obstacle detection function of the ultrasonic sensor and to perform the avoidance algorithm based on the measurement value of the acceleration gyro sensor. It is proposed an access surveillance system that minimizes the damage of drones, surrounding objects, and people, and improves air mobility. Experimental results show that the obstacles around the drone are detected by five ultrasonic sensors and the difference of output value is applied to each motor of the drone and obstacle avoidance is confirmed. In addition, the content and level of the data for measuring the achievement of learning achievement in the engineering education certification program were used and the results were confirmed to be consistent with the description of the engineering problem level required for the graduates of 4-year engineering college.