• Title/Summary/Keyword: Blowing

Search Result 568, Processing Time 0.028 seconds

Dust collection system optimization with air blowing and dust suction module (에어 블로어와 흡입기능을 가진 미세먼지 흡입시스템의 최적화)

  • Jeong, Wootae;Kwon, Soon-Bark;Ko, Sangwon;Park, Duckshin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.290-297
    • /
    • 2016
  • The performance of track cleaning trains to remove accumulated fine particulate matter in subway tunnels depends on the design of the suction system equipped under the train. To increase the efficiency of the suction system under the cleaning vehicle, this paper proposes a novel dust suction module equipped with both air blowing nozzles and a dust suction structure. Computational Fluid Dynamics (CFD) analysis with turbulent flow was conducted to optimize the dust suction system with a particle intake and blowing function. The optimal angle of the air blowing nozzle to maximize the dust removal rate was found to be 6 degrees. The performance of the track cleaning vehicle can be increased by at least 10 percent under an operation speed of 5km/h.

A Study on the Justification for Disciplinary by the reason for Whistle-blowing (근로자의 내부고발을 이유로 한 징계의 정당성)

  • Choi, Hong-Ki
    • Journal of Legislation Research
    • /
    • no.44
    • /
    • pp.611-653
    • /
    • 2013
  • An whistle-blowing is recognition of acts of misconduct or corruption by individuals(laborers) or party which belongs to a certain organization and it refers to the act of informing to the senior organization or to the outside public agency to avoid jeopardies that could be potentially lead against benefit of the public. These whistle-blowings can be a Ansatz that improve corporation's transparency and accountability by prevention of enterprise's misconduct as well, it has been recognized as an important role for the establishment of corporate ethics, moreover, social justice. What to be treated primarily as labor law problem is arousing some controversies of the possibility that the public announcement could be whether a disciplinary punishment or not because it brings some mischievous effects for the honor and the reputation to the company which conducted the illegal actions and the action of the contrary to the social value. And futhermore, recently, the matter of compensational responsibility according to the arrangement conversion, bullying followed by the informant has been brought up. The fundamental standpoint of precedent related with the judgement of justification for the punishment as reason of the whistle-blowing ought to do the sincere duty for the labor contract which is the employees are supposed to consider the employer's profits. For that reason, if the emploee release the inside fact to the public and give any damages to employer's secret or confidence or honor, it will be a causing reasong of the disciplinary punishment, but in specific cases, the relevant and level of punishment limitation can be judged by the contents of public announcement and the truth, the purpose of the acts and details and the way of announcement. Precisely, on the assumption that there are necessity of the characteristic profit or the freedom of expression for the informant, with overall consideration whether or the basis part of the informant is true or there is a fair reason which make the informant believe is true or the purpose of informant has the public profit or the contents of the whistle-blowing are important for relevant organization or the means and the way was suitable, if the whistle-blowing are approved to be resonable, the organization are not permitted the reprimand or dismiss Futhermore, to find the solution for the issues of the disciplinary punishment and the treatment of all sorts of disadvantages, for the reason of whistle-blowing, since the protection law for public declarer which was enacted in last 2011 have the position as the general law, the purport of the equal law has to be considered sytematically and also the judicial precedent which is related to the justification of whistle-blowing are needed to be considered as well.

Physical Properties and Dyeability of Wool/Polyester Spun Blend Yarn and Its Fabrics Using Air Blowing and Electrostatic Spinning Technology(Cyclone) (공기분사 전기방적 기술(Cyclone)을 이용한 Wool/Polyester 혼섬사 소재의 물성 및 염색성)

  • Kim, Mikyung;Kim, Dongkwon;Jeong, Jaeseok;Jang, Bongsik
    • Textile Coloration and Finishing
    • /
    • v.28 no.2
    • /
    • pp.77-91
    • /
    • 2016
  • Recently, the spun blend yarns with staple fibers and filaments are being developed in the spinning process using an air blowing and electrostatic spinning technology(cyclone) in order to enhance the soft feeling and the fine count spun blend yarn manufacturing competitiveness. In this study, the appropriate separation condition of polyester multifilament was examined according to the treatment condition of conductive agents and voltage on polyester multifilament in the newly developed cyclone spinning process. And it was investigated the physical properties and dyeability of the cyclone wool/polyester spun blend yarns and its wool composite fabrics in comparison with existing sirofil wool/polyester spun blend yarn and its fabrics. As the result, it is determined that the newly developed cyclone wool/polyester spun blend yarn applied fabrics has a superior quality level in terms of practicality.

Effect of Hole Shapes, Orientation And Hole Arrangements On Film Cooling Effectiveness

  • Jindal, Prakhar;Roy, A.K.;Sharma, R.P.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.341-351
    • /
    • 2016
  • In this present work, the effect of hole shapes, orientation and hole arrangements on film cooling effectiveness has been carried out. For this work a flat plate has been considered for the computational model. Computational analysis of film cooling effectiveness using different hole shapes with no streamwise inclination has been carried out. Initially, the model with an inclination of $30^{\circ}$ has been verified with the experimental data. The validation results are well in agreement with the results taken from literature. Five different hole shapes viz. Cylindrical, Elliptic, Triangular, Semi-Cylindrical and Semi-Elliptic have been compared and validated over a wide range of blowing ratios. The blowing ratios ranged from 0.67 to 1.67. Later, orientation of holes have also been varied along with the number of rows and hole arrangements in rows. The performance of film cooling scheme has been given in terms of centerline and laterally averaged adiabatic effectiveness. Semi-elliptic hole utilizes half of the mass flow as in other hole shapes and gives nominal values of effectiveness. The triangular hole geometry shows higher values of effectiveness than other hole geometries. But when compared on the basis of effectiveness and coolant mass consumption, Semi-elliptic hole came out to give best results.

A Study on the Removal of Slagging and Fouling for an Optimal Operation of Power Utility Boilers (보일러 최적운전을 위한 슬래깅 및 파울링 제거 연구)

  • Yook, Sim-Kyun;Kim, Sung-Ho;Lee, Byeong-Eun;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1772-1780
    • /
    • 2003
  • An optimal soot blowing system has been developed for an optimal operation of power utility boilers by both minimization of the use of steam and the number of soot blowers worked during soot blowing. Traditionally, the soot blowing system has been operated manually by operators. However, it causes the reduction of power and thermal performance degradation because all soot blowers installed in the plant should be worked simultaneously even there are lots of tubes those are not contaminated by slagging or fouling. Heat transfer area is divided into four groups, furnace, convection area including superheater, reheater and economizer, and air preheater in the present study. The condition of cleanness of the tubes is calculated by several parameters obtained by sensors. Then, a part of soot blowers works automatically where boiler tubes are contaminated. This system has been applied in a practical power plant. Therefore, comparison has been done between this system and manual operation and the results are discussed.

Heat/Mass Transfer for Impingement/Effusion Cooling System with Circular Guide (원형가이드 설치에 따른 충돌제트/유출냉각에서 열/물질전달 특성)

  • Hong, Sung-Kook;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1147-1154
    • /
    • 2006
  • An experimental investigation was conducted to enhance the heat/mass transfer for impingement/effusion cooling system when the initial crossflow was formed. For the improvement of heat transfer, the circular guide is installed on the injection hole. At the fixed jet Reynolds number of 10,000, the measurements were carried out for blowing ratios ranging from 0.5 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result presents that the circular guide protects the injected jet from the initial crossflow, increasing the heat/mass transfer. The heat transfer of stagnation region is hardly changed regardless of the blowing ratio. The secondary peak is obviously formed by flow transition to turbulent flow. At high blowing ratio of 1.5, the circular guide produces $26{\sim}30%$ augmentation on the averaged heat/mass transfer while the case without circular guide leads to the low and non-uniform heat/mass transfer. With the increased heat/mass transfer, the installation of circular guide is accompanied by the increase of pressure loss in the channel. However, the pressure drop caused by the circular guide is lower than that for other cooling technique with the circular pin fin.

The study of laser processing parameter for $\mu$-BGA cutting ($\mu$-BGA 절단을 위한 레이저 가공 파라미터 연구)

  • Baek, kwang-yeol;Lee, cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.652-655
    • /
    • 2001
  • In this paper, I have studied minimization of the kerf-width and surface burning which are occurred after the singulation process of multi layer $\mu$-BGA( thickness 1.1 mm, 0.9 mm) with a pulsed Nd:YAG( = 532 nm, repetition rate = 10 Hz) laser. The thermal energy of a pulsed Nd:YAG laser is used to cut the copper layer. I have studied are minimization of the surface burning and kerf-width using a photo resist, $N_2$blowing and polyester double sided tape as a cutting parameter. The $N_2$blowing reduces a laser energy loss by debris and suppresses a surface carbonization. Also, I have studied characters of cutting with a choice of side of laser beam incidence. The SEM(Scanning Electron Microscope), non-contact 3D inspector and high-resolution microscope are used to measure kerf width and surface state. The optimum value of 1.1 mm $\mu$-BGA singulation is 524 $\mu$m that is reduced kerf width of 60 % with $N_2$blowing. And I obtained reduction of carbonization of 68 % with a polyester double side tape in 0.9 mm $\mu$-BGA. I used laser intensity of 1.91$\times$10$^{6}$ / $\textrm{cm}^2$ in this study.

  • PDF

Effect of Blowing Agents on Properties of Phenolic Foam (발포제 종류에 따른 페놀 폼의 물성 연구)

  • Jang, SaeYoon;Kim, Sangbum
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.30-34
    • /
    • 2016
  • In this study, we synthesized a phenol foam using a resol-type phenol resin as a research for replacing the polyurethane foam used as an insulator for cryogenic temperature, such as LNG or LPG. Foaming agents for synthesizing a phenolic foam was used HCFC-141b or n-pentane, cyclopentane, n-hexane, cyclohexane and a mixture of HFC-365mfc and HFC-227ea respectively. Cyclohexane as a blowing agent exhibited the most superior insulating performance and compressive strength. The heat resistance of polyurethane foam and phenolic foam blown by the cyclohexane, was higher than polyurethane foam.

Heat/Mass Transfer and Flow Characteristics Within a Film Cooling Hole of Square Cross Sections (I) - Effects of Blowing Ratio and Reynolds Number - (정사각 막냉각홀 내부에서의 열/물질전달 및 유동 특성 (I) - 분사비 및 레이놀즈 수 효과 -)

  • Kang, Seung-Goo;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.927-936
    • /
    • 2002
  • An experimental study has been conducted to investigate the heat/mass transfer characteristics within a film cooling hole of square cross-section for various blowing ratios and Reynolds numbers. The experiments have been performed using a naphthalene sublimation method and the flow field has been analyzed by numerical calculation using a commercial code. A duct flow enters into a film cooling hole in a cross-direction. For the film cooling hole with square cross-section, it is observed that the reattachment of separated flow and the vortices within the hole enhance considerably the heat/mass transfer around the hole entrance region. The heat/mass transfer on the leading edge side of hole exit region increases as the blowing ratios decrease because the main flow induces a secondary vortex. Heat/mass transfer patterns within the square film cooling hole are changed little with the various Reynolds numbers.

Three-Dimensional Flow Characteristics of a Circular Impinging Jet Normally Oriented to Crossflow (주유동에 수직으로 분사되는 원형 충돌제트의 3차원 유동특성)

  • Lee, Sang Woo;Jeong, Chul Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.12
    • /
    • pp.1735-1745
    • /
    • 1998
  • Oil-film surface flow visualizations and three-dimensional flow measurements using a straight five-hole probe have been conducted for a circular impinging jet which is normally oriented to the crossflow in a channel. Throughout the experiments, the ratio of channel height to injection hole diameter, H/D, is fixed to be 1.0, and blowing ratio is varied to be 1.0, 2.0, 3.0 and 4.0. From the surface flow visualizations for both top wall(target plate) and bottom wall, impinging jet region on the target plate can be clearly identified, and for the small value of H/D = 1.0, presence of the bottom wall changes the near-hole flow structure, significantly. The three-dimensional flow measurements show that in the dawnstream region of the injection hole, there exist a pair of counter-rotating vortices, called "scarf vortices", and the strength of the vortices strongly depends on the blowing ratio. In addition, a new flow model in the flow symmetry plane has been proposed for H/D = 1.0.