• Title/Summary/Keyword: Blood specimen collection

Search Result 10, Processing Time 0.026 seconds

Isolation of Anaerobic Bacteria from Oral Pyogenic Infections (구강 화농성 감염에서 혐기성 세균의 배양분리)

  • 장복실;이장희;최화석;최선진
    • Korean Journal of Microbiology
    • /
    • v.23 no.1
    • /
    • pp.43-48
    • /
    • 1985
  • Strict anaerobic procedures and anaerobic chamber were employed in order to improve the isolation of obligate anaerobes from oral pyogenic infections. Also different culture media were utilized to maximize bacterial recovery. Two blood media: nalidixic acid Tween blood agar (NATB) and plain blood agar (BA), two non-blood media: nalidixic acid Tween agar (NAT) and Gifu anaerobic medium (GAM) were used and compared for their isolation efficacy. Specimens from seven patients were collected with syringe. After collection, the needle was sealed with sterilixed silicone rubber and brought to labortory. The time spent from specimen collection to its processing in anaerobic chamber usually was 15 min. Identification of isolated bacterial strains was done with the API-20A system. Increase in isolation of anaerobic vacteria was achieved. Obligate anaerobic bacteria isolated were 3.3 strains per specimen. This figure falls within the range of 1.9-4.4 strains per specimen reported in other countries. With respect to the media utilized, blood media were superior to non-blood media. NATB medium was effective especially for the isolation of Gram-positive cocci. A total of 15 species of Gram-negative rods was isolated and 12 of them belonged to Bacteroides.

  • PDF

Blood Collection Workload and Safety of Medical Technologists at Korean Hospitals (한국 의료기관에서 임상병리사의 채혈 업무 현황과 안전 실태 조사)

  • Sung-Bae PARK;Suk JEKAL;Weon Joo HWANG;Do Wang LEE;Choong Won SEO;Sunghyun KIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.3
    • /
    • pp.159-166
    • /
    • 2023
  • This study investigates the current situation of medical technologists for blood collection, which is considered the most important step for diagnosis. The survey enrolled 650 medical technologists working in hospitals and medical check centers in Busan, Ulsan, and Gyeongnam. We found that each medical technologist performed blood collection for about 100 patients. There was more than one blood collection failure per day, with more than one case of pain and filing of civil complaints per year. Hence, there was a high work burden on the medical technologists. Cases where a medical technologist was stabbed with a used needle occurred more than once a year, and about 15% of them received infection control and treatment because of stab wounds. Additionally, more than half of the participants suffered from musculoskeletal disorders and mental stress due to blood collection work. Unlike administering intravenous and intramuscular injections using the same needle, no fee is charged for blood collection. Based on the results of this study, it will be possible to improve the safety and rights of medical technologists by calculating the actual fee for blood collection work and assigning a relative value score.

Specimen of Storage and Analysis for Genomic Epidemiology (유전체 역학 연구를 위한 시료의 보관과 분석)

  • Lee, Kwan-Hee;Hong, Yun-Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.3
    • /
    • pp.209-212
    • /
    • 2003
  • Because of advances of technologies in the field of genmic epidemiology in the recent years, specimen collection, storage and analysis became an essential part of research methodologies. DNA is now being used in epidemiologic studies to evaluate genetic risk factors and specimens other than the fresh whole blood can De used for PCR. Therefore, All nucleated cells, such as buccal swabs and urine specimens, are suitable for DNA analysis. For an unlimited source of genomic DNA, EBV transformation of lymphocytes can be used for immortalization. However, the type of specimen collected in genomic epidemiologic studies will depend on the study where the epidemiologist play a leading role for the design. We also briefly described various finds of analysis for SNP that is an essential part of the genomic epidemiology.

Factors Affecting Hemolysis in Blood Sampling and Repeated Sampling in the Emergency Department (응급실에서의 채혈로 인한 용혈 및 재채혈 관련요인)

  • Cho, Myung Sook;Hwang, Moon Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.3
    • /
    • pp.399-410
    • /
    • 2011
  • Purpose: This study was conducted to investigate the incidence of blood hemolysis and repeated blood sampling and to identify factors contributing to hemolysis and repeated blood sampling in the emergency department. Methods: A cross-sectional descriptive design was used. Participants were the patients who came to emergency department and are required a blood sampling for electrolyte level. All blood samples were collected by emergency department nurses and determined for hemolysis by experienced laboratory technologists. Data were analyzed using $x^2$-test, Fisher's exact test, Mann-Whitney u test and Binary Logistic Regression to determine significant differences. Results: A total of 402 valid samples were collected. Of these, 30 blood samples (7.5%) were found to be hemolyzed and 9 (2.2%) to be recollected. Statistically significant factors affecting on hemolysis and repeated blood sampling included the time of bloods sampling (night), the time of tourniquet application, and too-fast blood draw into the test tube. Conclusion: We recommend that nurses who take the blood sampling to consider the findings of the study and take the related factors into account as they set up the standardized care protocol in order for nursing quality improvement.

Prevalence of Malaria in Pregnant Women in Lagos, South-West Nigeria

  • Agomo, Chimere O.;Oyibo, Wellington A.;Anorlu, Rose I.;Agomo, Philip U.
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • Prevalence rates reported for malaria in pregnancy in Nigeria vary considerably. The accuracy of results of malaria diagnosis is dependent on training, experience, and motivation of the microscopist as well as the laboratory facility available. Results of training programmes on malaria microscopy have shown low levels of sensitivity and specificity of those involved in malaria diagnosis routinely and for research. This study was done to ascertain the true prevalence of malaria in pregnancy in Lagos, South-West Nigeria. A total of 1,084 pregnant women were recruited into this study. Blood smears stained with Giemsa were used for malaria diagnosis by light microscopy. Malaria infection during pregnancy presents mostly as asymptomatic infection. The prevalence of malaria in this population was 7.7% (95% confidence interval; 6.2-9.4%). Factors identified to increase the risk of malaria infection include young maternal age (<20 years), and gravidity (primigravida). In conclusion, this study exposes the over-diagnosis of malaria in pregnancy and the need for training and retraining of laboratory staffs as well as establishing the malaria diagnosis quality assurance programme to ensure the accuracy of malaria microscopy results at all levels.

The Effect of the Storage Duration and Temperature of EDTA Specimen for CBC and WBC Differential Count in SE-9000 Automated Cell Counter (SE-9000 자동 혈구계산기에서 EDTA 검체의 보관기간 및 온도가 CBC 및 백혈구 감별계산에 미치는 영향)

  • Hong, Seung-Bok;Kim, Jong-Seok;Shin, Kyeong-Seob
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.147-151
    • /
    • 2006
  • Although various automated CBC analyzers with different WBC analytical principles were consequently introduced to clinical laboratory, the specific information concerning the suitability or unsuitability of aging samples is scarce. For this reason, we studied the effect of storage duration and temperature on CBC parameter in SE-9000 (SYSMEX Medical Electronics Co., Ltd., Kobe, Japan), automated CBC analyzer. We tested 32 K3-EDTA specimens with SE-9000 during 72 hours. Specimens were kept at room temperature (RT) and refrigerated and were analyzed at 0 hr, 4 hr, 8 hr, 24 hr, 48 hr and 72 hr after the collection of the specimens. The percentage changes from initial value for each parameters were calculated. Among the CBC parameters, hemoglobin, red blood cell count, mean corpuscular hemoglobin and platelets were stable for the study period at both temperatures. The mean corpuscular volume (MCV), hematocrit (Hct) and red cell distribution (RDW) increased and the mean corpuscular hemoglobin concentration (MCHC) decreased over time at room temperature. These parameters were stable when refrigerated. The leukocyte count was stable during 72hr at RT and when refrigerated. At room temperature, the relative percentages of neutrophils tend to increase, whereas those of lymphocyte and monocytes tend to decrease after 48 hours. When refrigerated, those of neutrophils and monocytes tend to increase, whereas those of lymphocytes tend to decreased over time. CBC parameters of refrigerated specimen were reliable for 72 hr for the exception of differential count from 24 hr but many CBC parameters, such as MCV, Hct, MCHC, RDW and differential count of leukocyte of blood stored at room temperature for 24 hr were unreliable.

  • PDF

A Comparison of the Rates of Hemolysis and Repeated Blood Sampling using Syringe needles versus Vacuum tube needles in the Emergency Department (응급실에서의 주사기 채혈과 진공관 채혈의 용혈과 재채혈 비교)

  • Sung, Young-Hee;Hwang, Moon-Sook;Lee, Jee-Hyang;Park, Hyung-Doo;Ryu, Kwang-Hyun;Cho, Myung-Sook;Yi, Young-Hee;Song, S.
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.443-451
    • /
    • 2012
  • Purpose: This study was done to compare the rates of hemolysis and repeated sampling in blood samples obtained by a syringe needle versus a vacuum tube needle. Methods: A randomized, prospective study was used to evaluate the differences between the two blood sampling methods. The study group consisted of patients seen in the emergency department (ED) for blood sampling to determine electrolyte level. ED patients were randomly assigned to either the syringe group or the vacuum tube group. All blood samples were collected by experienced ED nurses and hemolysis was determined by experienced laboratory technologists. Data were analyzed using Fisher's exact test and binary logistic regression. Results: One hundred forty-five valid samples were collected (74 in the syringe group versus 71 in the vacuum tube group). 5 of 74 (6.8%) blood samples in the syringe group and 8 of 71 (11.3%) in the vacuum tube group hemolyzed. Repeated blood sampling occurred for 2 of 74 (2.7%) and 3 of 71 (4.2%) in each group respectively. There were no significant differences in rates of hemolysis and repeated sampling between two groups (B=1.97, p=.204; B=2.36, p=.345). Conclusion: Venipuncture with syringe needles can be recommended for ED nurses to obtain blood samples.

Anatomical Variations Encountered during Adrenal Venous Sampling: A Report of Three Case Series and Review of Literature (부신정맥채혈술 중 발견된 해부학적 변이들: 3건의 증례 보고 및 문헌 고찰)

  • Juyoung Pak;Hyoung Nam Lee;Myung Sub Kim;Hyerim Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.456-462
    • /
    • 2024
  • Primary aldosteronism is a group of disorders in which the autonomous secretion of aldosterone is associated with hypertension and hypokalemia. It is crucial to determine the laterality of aldosterone hypersecretion because treatment options differ accordingly. Adrenal venous sampling (AVS) is considered the most reliable method for assessing the laterality of primary aldosteronism. This procedure is often technically challenging because of the small size and varied locations of the adrenal veins. A better understanding of anatomical variations and careful review of imaging studies would improve sampling success. This report presents three cases of anatomical variations encountered during AVS.

Adrenal Vein Sampling in Primary Aldosteronism: A Pictorial Essay for Optimal Left-Side Sampling (일차성고알도스테론혈증에서의 부신정맥채혈술: 최적의 좌측채혈을 위한 임상화보)

  • Gi Joo Kim;Myung Sub Kim;Hyun Pyo Hong;Young Rae Lee;Yeon Gyu Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.386-397
    • /
    • 2023
  • Primary aldosteronism (PA) is a curable cause of hypertension. Recent studies have revealed that the actual prevalence of PA is higher than previously recognized. Adrenal vein sampling (AVS) is an essential diagnostic procedure for revealing the cause of PA and determining the treatment plan. The success of AVS is confirmed by comparing cortisol levels between the samples from each adrenal vein and peripheral vein. The failure rate of the procedure is reported to be high in the right adrenal vein, which is directly connected to the inferior vena cava, while that in the left adrenal vein is relatively low; however, this has rarely been reported. In this review, we introduce and analyze cases of failure in left adrenal vein sampling.

The Effects of Aprotinin Addition and Plastic Tube Usage for Glucagon Test Results (Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향)

  • Cho, Youn-Kyo;Choi, Sam-Kyu;Seo, So-Yeon;Shin, Yong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r=0.783 (p=0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r=0.979, p=0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r=0.754, p<0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

  • PDF