• Title/Summary/Keyword: Blood pressure wave

Search Result 137, Processing Time 0.027 seconds

Rheographic View of the Change in the Renal Blood Flow in Acute Hemorrhage (Rheogram으로 본 실혈시 신장혈액유통 변화)

  • Chang, Se-Gu;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.5 no.1
    • /
    • pp.59-69
    • /
    • 1971
  • Studies were undertaken on the changes in the renal blood flow by relating them with the alterations in the amplitudes in the rheogram of rabbits. The changing pattern of the electrical conductivity was recorded by means of the needle electrodes inserted into the kidney and the surrounding aluminium foil which was grounded. The Impedance Rheograph manufactured by the Narco Company was used. The small artifact which persisted after ligation of the renal vessels was subtracted from the value obtained in each pulsatile wave in the rheogram. The animals were nembutalized intravenously, 30 mg/kg. A plastic canule was inserted into the carotid artery and the arterial blood pressure was monitored continuously with the pressure transducer connected to the physiograph. Stepwise bleedings were performed on the animal. The first bleeding was between 13 to 18 ml in the amount, and it was folowed by consecutive hemorrhages, 5 or 10 ml each time. The total amount of bleeding was summed as much as 1.5-2% of the body weight. Two minutes fter each bleeding th arterial blood pressure, ECG and the rheogram were taken. That was the necessary time to obtain the stabilized picture of each parameter. After closing the bleeding process, the shed blood was retransfused into the animal and the response in the renal blood flow was observed as well as the arterial blood pressure. Particularly the presence or absence of the autoregulatory mechanism in the situation of the hemorrhage was also studied. The results obtained were as follows: 1. In 7 cases out of 22, that was about one third of the total number of experiments, the autoregulatory mechanism of the renal blood flow persisted even in acute hemorrhage, and the decreases in the renal blood flow were less than 10% of the control values even when the arterial blood pressure dropped to 66-87% of the original value obtained before the bleeding. 2. Because of the stepwise bleeding the exact blood pressure at which the renal blood flow reduced as much as one third of the control value could not be obtained. However, the results revealed that the approximate pressure, expressed as percentage of the control value, was 50-60% in 3 cases, 61-70% in 4 cases and 71-80% in 8 cases. In one case the decrease in the renal blood flow exceeded one third of the control value before the pressure dropped to 80% of the control. 3. In 19 cases the decreases in the renal blood flow exceeded one half of the control values by hemorrhage. Then the arterial blood pressure revealed less than 40% of the control value in 6-cases. In 2 cases the pressure was 51-60% of the control pressure. In 5 cases the range of bleed pressure was 61-70%, and in e remaining 6 cases the pressure ranged from 71 to 80% of e control value. 4. Out of 15 cases of retransfusion after definite decreases in the renal blood flow loller·ing the hemorrhage, 9 cases restored their renal blood flow. On the contrary 6 cases showed low values even when the shed blood was retransfused. 5. Theories concerning the mechanism of the autoregulation of the renal blood flow were reviewed for the purpose of explanation of the results obtained. However, there are much to be done before greater satisfaction

  • PDF

Blood Pressure Estimation for Development of Wearable small Blood Pressure Monitor Fusion Algorithm Analysis (웨어러블 초소형 혈압계 개발을 위한 혈압 추정 융합 알고리즘 분석)

  • Kim, Seon-Chil;Kwon, Chan-Hoe;Park, You-rim
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.209-215
    • /
    • 2019
  • The most important personal health care in digital health care is a very important issue mainly for chronic diseases. Therefore, it is important to develop a simple wearable device for real-time health management. Existing blood pressure estimation wearable devices use PPG characteristics to analyze PTT and propose blood pressure estimation algorithms. However, the influencing factors of the algorithm such as the reproducibility of PPG, whether to apply various PTTs, and variables generated from the physical differences of the measurers are actually very complex. Therefore, in this study, the correlation between PTT, SBP, and DBP was analyzed, and it was designed to use PPG sensors for device miniaturization. The blood pressure estimation algorithm took into account differences in PPG, heart rate, and personal variables.

Development of Real-time Blood Pressure Monitoring System using Radio Wave (전파를 이용한 실시간 혈압 모니터링 시스템 개발)

  • Jang, Dong-won;Eom, Sun-Yeong;Choe, Jae-Ik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.308-311
    • /
    • 2015
  • Because worldwide interest in the health is increased, the real-time health monitoring system has been demanded to be more convenient non-contact and precise medical devices than conventional. Therefore we developed the blood pressure monitoring system using UWB(Ultra Wide Band) radio wave which contact to the human body through the radar and continuously collect a movement signal of the blood vessel. Then the collected data including pulse rate, systolic blood pressure, diastolic blood pressure is processed in real time. The system monitors and controls through a program-based embedded LCD(Liquid Crystal Display) using Qt GUI(Graphic User Interface) to be displayed in real time. We implement the system as a embedded system because of reducing the size of the limited resources. Existing PC GUI design mode is used relatively large memory, therefore it requires more CPU(Central Processing Unit) capacity and processing time.

  • PDF

Correlation of Axillary Artery Pressure and Phase of Esophageal Impedance in Chickens

  • Nakajima, Isao;Kuwahira, Ichiro;Hori, Shuho;Mitsuhashi, Kokuryo
    • Journal of Multimedia Information System
    • /
    • v.9 no.2
    • /
    • pp.161-170
    • /
    • 2022
  • Under General anesthesia with isoflurane, we insert a chicken's esophageal catheter into the near the left atrium. 1MHz radio wave was added to electrocardiogram electrodes of the esophagus, and the change of impedance (phase) was obtained by amplitude synchronous detection technique. At the same time, a thin tube is surgically inserted into the axillary artery to continuously measure blood pressure. The correlation between impedance (phase) and blood pressure was obtained. Both showed a very high correlation (R2=0.9665). It was also observed the waveform flowing from the left atrium into the left ventricle. When an individual infected with the avian influenza virus develops, the cytokine storms lead to hypotension earlier than the test for antigen-antibody reaction. In order to detect this, in the future, this impedance technique will be useful for screening individuals infected with avian influenza virus by measuring the blood pressure of chickens in cages in a non-contact manner using microwaves.

Evaluation of Significance on the Brachial-ankle arterial pulse wave velocity And Cerebral Artery Vascular Stenosis (상완-발목 맥파 전달 속도와 뇌동맥 혈관 협착과의 유의성 평가)

  • Kim, Ji-Yul;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.873-878
    • /
    • 2019
  • Cerebrovascular disease is one of the three major causes of death in Korea. Since these diseases are associated with atherosclerosis, the diagnosis of atherosclerotic factors should be presented. In this study, we evaluated the relationship between brachial-ankle arterial pulse wave velocity, cerebral artery vascular stenosis, blood pressure, obesity, and abdominal obesity by age group. The significance of cerebral artery stenosis and age group. The risk factors of atherosclerosis, such as blood pressure, obesity, and abdominal obesity, were significant in all age groups. When the pulse wave velocity of the brachial-ankle artery was increased, the cerebral artery stenosis was distributed in 57.3% of the total test subjects. If the arterial stiffness is suspected during the measurement of the pulse wave velocity of the brachial ankle artery, We recommend suspected vascular stenosis and perform a cerebral artery angiography. It is suggested that the data will be used as a baseline data for similar studies after evaluating the significance of blood pressure, obesity, and abdominal obesity as risk factors of atherosclerosis.

Effect of dietary betaine on short chain fatty acid and blood profile in meat duck exposed to extreme heat stress (베타인이 폭염 오리의 짧은 사슬지방산 및 혈액 프로파일에 미치는 효과)

  • Hwangbo, Jong;Bang, Han-Tae;Park, Byung-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.394-404
    • /
    • 2015
  • This study investigated the pharmacodynamics of betaine on the blood profile and short chain fatty acid levels in meat ducks exposed to heat wave. 400 heads of Cherry valley (Anasplatyrhynchos) meat ducks were completely randomized to 5 treatments (4 repetitions each), and were raised for 42 days. They were grouped into T1 (heat wave control group without betaine), T2 (betaine 400 ppm), T3 (betaine 800 ppm), T4 (betaine 1200 ppm), and T5 (normal control group without betaine). Compared to T1, the betaine addition groups showed higher body weight gain at shipment, with T3 showing the highest significant difference. For hematological indictors measured (red blood cells and platelets), the betaine addition groups showed significantly higher values than the heat wave control group. The pH of the former was lower but their electrolytes ($K^+$, $P^+$, and $Cl^-$) were significantly higher compared to the latter. For blood gas concentration, the former showed a significantly higher value than the latter. For the total short chain fatty acids, acetic acid, and propionic acid, the betaine addition groups and group fed broiler-high temperature diet showed higher values than the heat wave control group. On the other hand, the former showed significantly lower values in butyric acid, isobutyric acid, valeric acid, and isovaleric acid than the latter group. These results suggest that betaine has the pharmacodynamics that mediate heat stress, via the maintenance and control of the blood profile, osmotic pressure, gas concentration, and short chain fatty acid, of meat ducks under heat wave.

Studies on the Physiology of Hibernation - with particular reference to blood level of insulin - (동면에 관한 연구 - 혈중 Insulin 농도의 변화 -)

  • Kang, Bok-Soon;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 1972
  • Physiological changes in hibernating animals (Manchurian Chipmunk and Hamster) were studied during various phases of the hibernation. The results obtained are summarized as follows. 1. Rectal temperature was declined markedly during hibernation, whereas it remained constant even in exposure of the animals to 0 C environment if the animals were not prepared for hibernation. As body temperature was lowered, heart rate was also markedly reduced as well as respiration and blood pressure. 2. The electrical activity recorded from cortical structure was characterized by replacement of fast wave activity by slow wave activity as body temperature was lowered and became flat at body temperature below 20C. 3. Blood glucose level showed no clear seasonal variations. However, the glycogen contents of the liver were markedly greater during the cold seasons than during the warm seasons. 4. Blood levels of insulin showed no clear seasonal variations.

  • PDF

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Analysis of the Impact of Reflected Waves on Deep Neural Network-Based Heartbeat Detection for Pulsatile Extracorporeal Membrane Oxygenator Control (반사파가 박동형 체외막산화기 제어에 사용되는 심층신경망의 심장 박동 감지에 미치는 영향 분석)

  • Seo Jun Yoon;Hyun Woo Jang;Seong Wook Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.128-137
    • /
    • 2024
  • It is necessary to develop a pulsatile Extracorporeal Membrane Oxygenator (p-ECMO) with counter-pulsation control(CPC), which ejects blood during the diastolic phase of the heart rather than the systolic phase, due to the known issues with conventional ECMO causing fatal complications such as ventricular dilation and pulmonary edema. A promising method to simultaneously detect the pulsations of the heart and p-ECMO is to analyze blood pressure waveforms using deep neural network technology(DNN). However, the accurate detection of cardiac rhythms by DNNs is challenging due to various noises such as pulsations from p-ECMO, reflected waves in the vessels, and other dynamic noises. This study aims to evaluate the accuracy of DNNs developed for CPC in p-ECMO, using human-like blood pressure waveforms reproduced in an in-vitro experiment. Especially, an experimental setup that reproduces reflected waves commonly observed in actual patients was developed, and the impact of these waves on DNN judgments was assessed using a multiple DNN (m-DNN) that provides accurate determinations along with a separate index for heartbeat recognition ability. In the experimental setup inducing reflected waves, it was observed that the shape of the blood pressure waveform became increasingly complex, which coincided with an increase in harmonic components, as evident from the Fast Fourier Transform results of the blood pressure wave. It was observed that the recognition score (RS) of DNNs decreased in blood pressure waveforms with significant harmonic components, separate from the frequency components caused by the heart and p-ECMO. This study demonstrated that each DNN trained on blood pressure waveforms without reflected waves showed low RS when faced with waveforms containing reflected waves. However, the accuracy of the final results from the m-DNN remained high even in the presence of reflected waves.

Elevated Levels of Serum Lipids Accelerate Biological Vascular Aging evaluated by the Second Derivative of Photoplethysmogram Waveform in the Middle-Age Adults (중년 성인남녀의 혈중 지질농도가 가속도맥파에 미치는 영향)

  • Nam, Tong-Hyun;Koh, Hyung-Kyun;Park, Young-Bae
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.126-137
    • /
    • 2002
  • Objective : There is accumulating data that cardiovascular diseases, including hypertension, cerebro-vascular accident, coronary heart disease, relate to atherosclerotic changes. Increased serum levels of lipids could play a role in these circumstances. the SDPTG(the second derivative of photoplethysmogram waveform) is noninvasive methods for evaluating the pulse wave and is correlated with age and other risk factors for atherosclerosis. Methods : To study the effects of serum lipid levels on the SDPTG in the middle-age adults, data on serum lipid levels and the SDPTG were collected in 80 healthy middle age with varying serum lipid concentrations. Biological vascular age was assessed using the SDPTG. the SDPTG consists of an a, b, c, and d wave in systole and an e wave in diastole; an SDPTG aging index(Al) was calculated as (b-c-d-e)/a. Results : Serum triglyceride, total cholesterol, total lipid, phospholipid, HDL cholesterol levels were respectively and significantly correlated with SDPTG Al. Serum lipid levels and blood pressure are age-dependent and the SDPTG is blood pressure-dependent. Restricting analysis to age and blood pressure yield strong positive correlations between serum triglyceride, total lipid levels and SDPTG Al, but no correlations between serum total cholesterol, phospholipid levels and SDPTG Al. Conclusion : The results of this study suggest that preventive acupuncture programs or herbal medications for reducing serum lipid, especially triglyceride, levels in middle-age should include a evaluation of biological vascular aging with the second derivative of photoplethysmogram waveform.

  • PDF