• Title/Summary/Keyword: Blood gas analysis

Search Result 220, Processing Time 0.032 seconds

Disposal of CO in CO-Poisoning Dogs (일산화탄소중독견(一酸化炭素中毒犬) 체내(體內)에서의 일산화탄소처리능(一酸化炭素處理能)에 관(關)하여)

  • Ryo, Ung-Yun;Kang, Bann
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1968
  • The Present study attempted to analyze the fate of CO diffused into the circulating blood through the alveoli. Dogs were induced to CO poisoning by rebreathing CO gas mixture contained in Krog's spirometer, by closed circuit method, for 60 minutes. The spirometer was filled initially with 282 ml of CO and 20 liters of air and oxygen, so the composition of gases were arranged as 1.4% in CO and 50% in $O_2$ at the begining of the rebreathing. Oxygen was added corresponding to the utilization of $O_2$ by the animal in proceeding of the experiment. At 60th minutes of CO rebreathing, the concentration of CO in arterial blood and in mixed venous blood were analysed and compared with each other after the CO contents were corrected with the hematocrit measured in the arterial and mixed venous blood. The distribution of CO gas to other tissues was estimated by the analysis of CO diffused into the cystic bile and into the peritoneal gas pocket which was formed by injection of 300 ml air into the peritoneal cavity prior to the CO gas rebreathing. The blood volume was measured by dilution method using $^{51}Chromium$ tagged red cells. CO amount vanished in the animal body was calculated by subtraction of total CO content in blood stream and the CO remained in closed circuit breathing system from the CO amount given to the breathing system at the begining of the experiment. Results obtained are summarized as follows: 1. The content of CO corrected by the hematocrit value was slightly less in mixed venous blood than in arterial blood. The amount of CO diffused into the cystic bile and into the peritoneal cavity was averaged to 0.1% and 0.4% of the CO amount in 100 ml of blood, respectively. 2. For 60 minutes of CO rebreathing, CO-hemoglobin saturation reached about 77% at the 60th minutes, CO amount vanished in the experimental animal averaged 36.1 ml/dog/hr., or 21% of the total CO volume in the blood stream. The average vanishing rate of CO during 60 minutes of CO rebreathing per kg of body weight was 2.71 ml/hr. Production of CO measured in ten dogs under hypoxic condition averaged 0.023 ml/kg/hr. The major part of the CO vanished in the dogs seemed to be oxidized to $CO_2$ by various tissues of the animal. The conclusion might be delivered as such oxidation of CO to $CO_2$ by animal tissues can play a role in part of the process of recovery and protection of animal from CO-poisoning.

  • PDF

Simultaneous Analysis of 17 Organophosphorous Pesticides in Blood by Automated Head Space-SPME GC/MS (HS-SPME-GC/MS에 의한 혈액중 17종 유기인계 농약의 동시분석법)

  • Rhee, Jong-Sook;Jung, Jin-Mi;Lee, Han-Sun;Yeom, Hye-Sun;Lee, Sang-Ki;Park, Yoo-Sin;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.54 no.6
    • /
    • pp.429-440
    • /
    • 2010
  • HS-SPME-GC/MS was studied and optimized for the determination of 17 orgarnophosphorous pesiticides (OPPs: chlorpyrifos, chlorpyrifos-methyl, demeton-s-methyl, diazinon, dimethoate, EPN, fenitrothion, fenthion, malathion, methidathion, monocrotophos, parathion, phenthoate, phosphamidon, sulfotep, terbufos, triazophos) in blood. Optimum SPME parameters were selected: choice of SPME fiber (85 ${\mu}m$ polyacrylate), pH effect (0.5 N HCl), salt effect ($Na_2SO_4$, 0.2 g; 20%), headspace incubation temperature ($80^{\circ}C$), headspace incubation time (1 min), headspace adsorption time (30 min) and GC desorption time (2 min). These parameters were optimized using HS-SPME autosampler coupled with gas chromatography-mass spectrometry (GC-MS). Method validation was carried out in terms of linearity, limit of detection (LOD), limit of quantitation (LOQ) and recovery in blood. The assay was linear over 0.5~5.0 mg/l ($r^2$=0.955~1.000). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were determined 0.03~0.3 mg/l (S/N=3) and 0.1~1.1 mg/l (S/N=10), respectively. Relative recovery with 0.5, 1 and 5 mg/l (in blood) were 90.8%, 98.5% and 94.1%, respectively. This method will be applied to the determination of the orgarnophosphorous pesticides in postmortem blood. The proposed protocol can be an attractive alternative to be used in routine toxicological analysis.

Quantitative Analysis of Lung Contusion (폐좌상의 정량분석)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.833-837
    • /
    • 1994
  • Lung contusion due to blunt chest trauma is the most common lung injury and correlated with the clinical course and prognosis. Its diagnosis by CT[Computerized Tomogram] gives a more clear and understandable three dimensional view, by which we are able to measure the volume of the contused and entire lung. Other variables are arterial blood gas, number of rib fracture, presence of hemopneumothorax, sternal fracture and clavicle fracture, number of associated non-thoracic injuries, ventilator time and presence of pulmonary complication. Percentage[%] of lung contusion are expressed as mean $\pm$ standard deviation and data analysis was performed by means of multivariate repeated measures analysis of variance to detect significant differences in variables between positive thoracic injury group and negative group. The paired t-test was used. Differences of percentage of lung contusion between groups were assessed by one-way analysis of variance. Simple linear regression was used to perform correlation analysis in the number of rib fracture and ventilator time. A p value less than 0.05 was considered statistically significant. Pneumothorax and the number of associated other injuries affect the amount of lung contusion and pulmonary complication group has more contused lung volume. Arterial blood gas study shows no correlation with the amount of lung contusion statistically. The number of rib fracture correlated with the amount of lung contusion, which also correlated with ventilator time[r=0.56, p<0.05]. In conclusion, quantitative anlysis of lung contusion by CT predicts the clinical course and treatment such as ventilator care.

  • PDF

Arterial and Venous Blood Gas, Electrolytes, Biochemical and Hematological Values in Healthy Korean Native Calves (건강한 한우 송아지의 동맥과 정맥 혈액의 혈액가스, 전해질, 생화학 및 혈액학적 측정치)

  • Lee, Sung-hwan;Ok, Seung-hoon;Kwon, Hyeok-ho;Kim, Doo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.499-503
    • /
    • 2015
  • The objective of this study was to investigate arterial and venous blood gas, electrolytes, biochemical, and hematological values in healthy Korean native calves (KNC). The healthy 62 KNC within 3 weeks-old were examined. The arterial blood was collected from caudal auricular artery and the venous blood from jugular vein. The blood samples were analyzed immediately using a portable blood gas analyzer. The pH, $pO_2$, $pCO_2$, $cHCO_3{^-}$, BE, $cSO_2$, $Na^+$, $Ca^{2+}$, $Cl^-$, anion gap potassium (AgapK), Hct, cHgb, glucose, lactate and creatinine were determined. The normal values for blood gas, electrolytes, biochemical, and hematological variables determined in this study agree with other published values for normal calves. The mean concentration of glucose and lactate within 3 weeks old of KNC is higher than those of adult cattle. The blood values according to weeks of age within 3 weeks-old of arterial and venous blood variables were not significantly different (P > 0.05). Glucose (r = 0.927) had the strongest correlations between arterial and venous values. The correlation between the values of the arterial and the venous blood was strong in creatinine (r = 0.925), lactate (r = 0.815), $Ca^{2+}$ (r = 0.806), Hct (r = 0.799), $Na^+$ (r = 0.790), cHgb (r = 0.786), base excess (r = 0.749), pH (r = 0.710), $HCO_3{^-}$ (r = 0.710), and $cTCO_2$ (0.663). Analysis of blood samples in a field condition, using hand-held analyzer is rapid and useful in bovine practice.

Imaging Diagnosis of Emphysematous Pyelonephritis in a Non-Diabetic Dog

  • Kim, Heesu;Lee, Kija;Chung, Jinyoung;Ahn, Jinok;Park, Inchul;Choi, Sooyoung
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.231-234
    • /
    • 2020
  • An 11-year-old, 4.3 kg, mixed breed, intact female dog exhibiting vomiting and a reduced appetite was presented. On physical examination, palpation of the right kidney elicited discomfort. Blood analysis revealed leukocytosis with neutrophilia, and elevation of alkaline phosphatase and blood urea nitrogen. Escherichia coli was detected in urine culture, whereas urine analysis showed absence of glucose. Radiography and ultrasonography suggested that there was gas in the right renal parenchyma, and computed tomography was performed while the dog was awake to investigate the suspected gas in the right kidney. After unilateral ureteronephrectomy, a histological diagnosis of right emphysematous pyelonephritis (EPN) was made. EPN refers to a severe necrotizing infection of the renal parenchyma with gas accumulation in the tissue. It is rare in both human and veterinary medicine, and almost all EPN patients have uncontrolled diabetes mellitus. This case report describes the imaging-based diagnosis of a rare occurrence of unilateral EPN in a non-diabetic dog.

Method Validation for the Simultaneous Analysis of Organophosphorous Pesticides in Blood by GC/MS (GC/MS를 이용한 혈액 중 유기인제류 농약의 동시 분석에 관한 방법의 유효화)

  • Park Mee Jung;Yang Ja Youl;Kim Ki Wook;Park Yoo Shin;Chung Hee Sun;Lee Sang Ki
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.4 s.51
    • /
    • pp.297-302
    • /
    • 2005
  • The purpose of this study was to provide the standard method for the analysis of organophosphorous pesticides such as chlorpyrifos, diazinon, malathion and parathion in blood. We performed method validation for these pesticides in blood according to EURACHEM (A focus For Analytical Chemistry in Europe) guide. For the analysis of the pesticides, we used solid-phase extraction ,column (Waters Oasis $HLB^{(R)}$. After the extraction, the supernatants were evaporated to dryness under the nitrogen stream. They were analyzed by gas chromatography/mass spectrometry (GC/MS) after reconstituting with ethanol. Terbufos was used as an internal standard. To validate this method, we performed verification procedures with the following parameters: selectivity, linearity of calibration, accuracy, precision, limit of detection and quantification. Validation data according to Eurachem guide were adequate for our purpose for the analysis of chlorpyrifos, diazinon, malathion and parathion in blood.

Quantitative Determination of Styrene in Blood and Mandelic Acid in Urine of the Occupationally Styrene-exposed Workers

  • Yang, Jeong-Sun
    • Archives of Pharmacal Research
    • /
    • v.17 no.2
    • /
    • pp.76-79
    • /
    • 1994
  • The concentration of styrne in blood of the occupationally syrene-exposed workers was checked by gas chromatographic headspace analysis. Mandelic acd in urine, that is a major metabolite of styrene, and hippuric acid wre also analyzed by high performance liquid chromatography. For the biological monitoring of styrene-exposed workers, the routine method of the quantitative determination of styrene nad its metabolites in the biolgical samples were studied.

  • PDF

Development of Automatic Data Transmitting System of Atrial Blood Gas Results via LAN (LAN을 이용한 혈액가스 검사결과 전송시스템)

  • Kim, Nam-Hyun;Huh, Jae-Man;Kim, Ji-Hyue;Kim, Do-Nyun;Kim, Won-Ky;Chang, Byung-Chul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.103-104
    • /
    • 1992
  • Automatic transmission of data from the blood analyzer to the request site is one of the most important part in hospital computerization. We have developed a system to automatically transmit the data from the atrial blood gas analyzer. In this system, HOST computer, FILE server, LAN(Local Area Network), 3270 Emulator and Multi-port card were integrated. Also, 3 blood gas analyser(NOVA Inc., USA) were connected to a single multi-port card which is attached in a personal computer for data acquisition. When specimen is collected from sampling sites, it is transfered to the lab. After analysis, the result is transmitted to the personal computer via serial communication between machine and multi-port card using interrupt method. Then, the patient's information (Name, Sex, etc.) is obtained from the HOST computer througth the emulator. The combined data(patient information & lab data) is transmitted to the each request site via LAN automatically. From the collected data, patient's previous data could be reviewed, and it could be used for the various statistics and the flow chart for clinical research. Also, we found that this system reduces the personal labor.

  • PDF

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF

The Usefulness of the Admission Base Deficit as a Marker of Mortality in Severely Injured Patients with Blunt Trauma (둔상성 중증 외상환자에서 내원 초기에 시행한 동맥혈 염기결핍과 예후의 관계)

  • Yu, Byung-Chul;Chung, Min;Lee, Gil-Jae;Lee, Jung-Nam
    • Journal of Trauma and Injury
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • Purpose: The base deficit (BD) at admission in severely injured patients has been shown to predict the adequacy of resuscitation and outcome, but this relationship is not well established in the Korean experience. The purpose of this study was to define the association between arterial blood gas (ABG) values and the mortality for patients with severe blunt trauma at a developing trauma center in Korea. Methods: A retrospective review of 415 adult patients with severe blunt trauma was conducted using electronic medical records from Jan. 2010 to Dec. 2011. Results: A total of 256 patients had ABG drawn within 1 hour of arrival. Patients who expired displayed a higher lactate level (4.86 vs. 3.31, p<0.0001), a worse BD (-7.99 vs. -5.37, p=0.001), and a lower pH (7.31 vs. 7.34, p=0.011) at arrival compared with those who survived. A statistically significant association was also observed between BD and blood product usage (p=0.001). Conclusion: The base deficit at admission is a useful marker of mortality and outcome in severely injured patients with blunt trauma in Korea.