• Title/Summary/Keyword: Blood gas

Search Result 508, Processing Time 0.022 seconds

Effect of Lactobacillus acidophilus based probiotic product supplementation on the blood profile, fecal noxious gas emission, and fecal shedding of lactic acid bacteria and coliform bacteria in healthy adult Beagle dogs

  • Sun, Hao Yang;Kim, In Ho
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.437-443
    • /
    • 2020
  • The aim of this study was to evaluate the effect of Lactobacillus acidophilus probiotic (LAP) product supplementation on the blood profile, fecal noxious gas emission, and fecal shedding of lactic acid bacteria and coliform bacteria in healthy adult Beagle dogs. In total, 14 Beagle dogs with an average initial body weight of 10.19 ± 0.61 kg were randomly assigned into two dietary treatments,with and without LAP supplementation, for a 28-day feeding trial. At the end of the experiment, there was no significant (p > 0.05) difference in the concentration of serum total cholesterol, high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), white blood cell (WBC), red blood cell (RBC), blood lymphocyte percentage, fecal hydrogen sulfide (H2S) and total mercaptans (R.SH) emission, and fecal coliforms counts. However, the serum concentrations of the triglyceride and fecal ammonia (NH3) emission of the LAP treatment were significantly (p < 0.05) decreased in the group compared with the CON dogs. Fecal total lactic acid bacteria counts were significantly (p < 0.05) increased in the LAP treatment. In conclusion, the supplementation of LAP in Beagle dog diets could decrease the blood triglyceride level and enhance the gut Lactobacillus count which may have positive effects on dogs.

Relationship between the values of blood parameters and physical status in Korean native calves with diarrhea

  • Lee, Sung-Hwan;Choi, Eun Wha;Kim, Doo
    • Journal of Veterinary Science
    • /
    • v.21 no.2
    • /
    • pp.17.1-17.11
    • /
    • 2020
  • Dehydration, electrolyte disturbance, and acid-base imbalance are the most significant consequences of diarrhea in calves. We aimed to determine blood gas, hematological, electrolyte, and biochemical values and investigate the relationship between the physical status and blood parameters in Korean native calves (KNCs) with diarrhea. One hundred eighty KNCs with diarrhea (age < 75 days) were investigated. Blood samples were collected from the external jugular vein and analyzed using a portable clinical blood gas analyzer. The measured parameters were statistically compared according to the status of physical activity, dehydration, or prognosis. The mean values of parameters in the Calves with diarrhea showed metabolic acidosis, hyponatremia, and azotemia. The mean values of potassium, chloride, hematocrit, and hemoglobin were in the upper limit of their reference ranges. More than 75% of the calves had metabolic acidosis caused by bicarbonate loss, and 63.6% had high blood urea nitrogen (BUN) values. Moreover, BUN showed the highest correlation with the physical activity status and dehydration. pH, base excess of the extracellular fluid (BE), anion gap, potassium, hematocrit, bicarbonate, and hemoglobin were closely correlated with physical deterioration and dehydration (p < 0.001). BUN, pH, BE, and anion gap were closely correlated with physical deterioration and dehydration. These correlations between clinical symptoms and blood gas parameters can be clinically relevant in predicting the status of parameters according to clinical symptoms.

Availability of Capillary Blood Gas Analysis in Neonate (신생아에서 모세혈 가스분석 검사의 유용성)

  • Jeong, Jong Tae;Yun, Su Young;Lee, Ran;Hyun, Jae Ho;Jung, Gyu Young
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.449-453
    • /
    • 2002
  • Purpose : Arterial blood gas analysis is frequently performed in neonatal intensive care unit (NICU) to evaluate ventilation and the metabolic state of critically ill infants. In occasions when umbilical arterial catheterization is not available, frequent arterial puncture is mandatory. This requires some technical skill and may occasionally have side effects. So we studied the validity of capillary blood gas analysis which can be performed conveniently compared with arterial blood. Methods : Twenty-four neonates admitted to NICU during April to Aug. 2001 were studied. They were more than two weeks old without indwelling arterial catheters. Thirty-six times, simultaneous arterial, and capillary blood gases were drawn by puncture and the pH, $pCO_2$ and $pO_2$ of each sample was measured. Blood pressure and body temperature was checked before sampling to rule out impaired peripheral circulation. Capillary blood was collected from warmed heels. Results : There was a strong correlation between capillary and arterial pH(r=0.91, P<0.05). The absolute value of the difference between arterial and capillary pH was less than 0.05. Also capillary $pCO_2$ showed correlation with arterial $pCO_2$(r=0.77, P<0.05). Despite a statistically significant correlation between capillary and arterial $pO_2$(r=0.68, P<0.05), the absolute value of the difference was more than 10 mmHg in 92% of cases. Conclusion : Capillary blood gases accurately reflected arterial pH and $pCO_2$ and showed a relative correlation with $pO_2$. Capillary blood gas analysis can be a useful alternative to arterial blood when continuation of the umbilical arterial catheter is no longer available.

Effect of canine electroacupuncture anesthesia on changes of vital signs and blood gas values (개의 전침마취가 Vital sign 및 혈액가스치 변화에 미치는 영향)

  • Lim, Yeon-Soo;Song, Kun-Ho;You, Myung-Jo;Seo, Jee-Min;Kim, Myung-Chul;Kim, Duck-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.1
    • /
    • pp.157-163
    • /
    • 2003
  • The present study was performed to elucidate the effect of canine electroacupuncture anesthesia on vital signs and blood gas values. Groups were divided into experimental (electroacupuncture: EA) and control (ketamine) groups. The vital signs (body temperature, respiration rate and pulse) and blood gas values (pH, $pCO_2$ and $pO_2$) of venous and arterial blood were determined. Body temperatures of EA group were significant higher than than of ketamine group at 15 min., 30 min., 45min. and 60 min. (p<0.05) after anesthesia, respectively. The respiration rates of EA group were higher than those of ketamine group, however, significant differences were not observed between both groups. The pulses of EA group were significant higher than those of ketamine group at 5 min. (p<0.05), 10 min. (p<0.01), 15 min. and 30 min. (p<0.05) after anesthesia, respectively. The arterial and venous blood pHs of ketamine group were slightly higher than those of EA group, respectively, however, no significant differences were found between both groups. Significant differences were not observed between both groups in the arterial and venous blood $pCO_2$, respectively. The arterial blood $pO_2$ of EA group was significant higher than those of ketamine group at 5 min. (p<0.05) after anesthesia. No significant differences were observed between both groups in the venous blood $pO_2$. These results suggest that the changes of vital signs and blood gas values of EA group are similar to those of ketamine group with the exception of changes in the body temperature, pulse and arterial blood $pO_2$.

Detection of Blood Agent Gas Using $SnO_2$ Thin Film Gas Sensor

  • Choi, Nak-Jin;Kwak, Jun-Hyuk;Lim, Yeon-Tae;Joo, Byung-Su;Lee, Duk-Dong;Bahn, Tae-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.69-75
    • /
    • 2004
  • In this study, thin film gas sensor based on tin oxide was fabricated to examine its characteristics. Target gas is acetonitrile ($CH_3$CN) which is a blood simulant for the chemical warfare agent. Sensing materials are SnO$_2$ SnO$_2$/Pt, and Sn/Pt with thickness from 1000 to 3000 $\AA$. The sensor consists of a sensing electrode with inter-digit (IDT) type in front side and a heater in rear side. Resistance changes of sensing materials are monitored on real time basis using a data acquisition board with a 12-bit analog to digital converter. Sensitivities are measured at different operating temperatures also with different gas concentrations and film thickness. The high sensitivity is obtained for Sn (3000 $\AA$)/Pt (30 $\AA$) at 30$0^{\circ}C$ for 3 ppm. Response and recovery times were about 40 and 160 s, respectively. Repetition measurements showed very good results with $\pm$3% in full scale range.

Effects of Malotilate on Levels of Ethanol and Acetaldehyde in Blood (혈중 Ethanol 및 Acetaldehyde의 농도에 미치는 Malotilate의 영향)

  • 허인회;이상준;주왕기;허문영;김형춘;송계용
    • YAKHAK HOEJI
    • /
    • v.31 no.6
    • /
    • pp.399-401
    • /
    • 1987
  • A gas chromatographic utilizing procedure headspace gas analysis is performed to study effect of malotilate on levels of ethanol and its metabolite acetaldehyde in a blood sample from the rat. The concentrations of ethanol and acetaldehyde were determined simultaneously at 1, 3, and 6h after ethanol administration. Our results would suggest the malotilate could promote clearances of ethanol and acetaldehyde in blood, and could accelerate it, especially, in $CCl_4$ pretreated rats.

  • PDF

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.

Elimination of CO through the Lung in CO Poisoned Dog (일산화탄소중독시(一酸化炭素中毒時) 폐(肺)로 부터의 일산화탄소(一酸化炭素) 방산(放散)에 관(關)하여)

  • Kang, Bann;Kim, Kun-Joo;Ryo, Ung-Yun
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.185-191
    • /
    • 1967
  • In order to evaluate the elimination of CO through the lung comparing with the decrease of CO content in the blood, authors had induced acute CO poisoning on 9 dogs. Arterial CO-Hb saturation, CO concentration, %, in expired gas and eliminated CO amount through the lung were measured at 1,5,10,30,60, and 120 minutes after acute CO poisoning in 6 dogs breathing room air and 3 dogs breathing room air and oxygen alternately. Results obtained are summarized as follows. In room air breathing group, arterial CO-Hb saturation averaged 50.8% , and 53.67 ml of CO was blew off through the lung during 120 minutes and in alternately air and oBygen breathing group, the arterial CO-Hb saturation averaged 65.6% and 95.6 ml of CO was blew off through the lung. The amount of CO eliminated in expired gas for 120 minute was much less than the amount of decreased CO in arterial blood which was calculated with the decreased CO-Hb content in the estimated circulating blood volume. Such difference between the amount of eliminated CO in expired gas and the decreased CO in blood might be attributed to the oxidation of CO to $CO_2$ in the tissues. Concentration of CO in expired gas was markedly increased and the rate of decrease in arterial CO-Hb saturation is enhanced by oxygen breathing. In early period of recovery from acute CO poisoning, neither the CO concentration in expired gas, nor, the rate of CO elimination (unlit 2 minutes after CO poisoning) showed close correlation with the blood CO-Hb saturation level. The reason seemed to be due to irregularly depressed or unevenly stimulated respiration which were induced by acute CO poisoning.

  • PDF

Implementation on the Portable Blood Gas Analyzer (휴대형 혈액가스 분석시스템의 구현)

  • Kang S.C.;Jeong D.U.;Bae J.W.;Shon J.M.;Shim Y.B.;Jeon G.R.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1032-1036
    • /
    • 2006
  • In this study, we implement the potable blood gas analyzer measuring pH, $pCO_2\;and\;pO_2$ of the arterial blood. The implemented system by this study is divided into hardware and software part and also the hardware portion is parted by mechanism and electronic circuit mit. The system program is composed of operating, washing, correcting and measuring program. And to correct the system, two-point calibration method is used, one-point calibration method is also added for more accuracy, and system program is coded. For verifying the implemented system, We examine to response property of each electrode. And evaluate accuracy of the system using standard reagent and was construed as statistical.

  • PDF

Implementation on the Portable Blood Gas Analyzer and Performance Estimation (휴대형 혈액가스분석 시스템의 구현 및 성능평가)

  • Jeong, Do-Un;Jeon, Gye-Rok;Bae, Jin-Woo;Kim, Gil-Jung;Sim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.34-43
    • /
    • 2003
  • In this study, we implemented the measurement of pH, $pO_2$, $pCO_2$ of the arterial blood on a portable blood gas analysis system. This system is consist of two parts of hardware and software. The hardware part is divided into a fluidic mechanism and an electronic circuit unit. The system program is composed of operating, washing, correcting, and measuring routines. Both of 1-point and 2-point calibration schemes were used to enhance the accuracy of the measurement. In order to evaluate the performance of the developed system, we measured and performed statistical analysis on the characteristics of the sensing electrode response. As a result, coefficient variation was within 1.12, and maximum error was within 1.298%. We confirmed development possibility of portable blood gas analyzer.