• 제목/요약/키워드: Blood artery

검색결과 1,242건 처리시간 0.026초

개에서 심장사상충증의 발생 2례 (Two Cases of Dirofilariasis in Dogs)

  • 김명철;김종만;김덕환;강종일
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.235-238
    • /
    • 1999
  • Two Jindo dogs which show clinical signs of anorexia, weakness and exercise intolerance, were referred, and diagnosed as dirofilariasis by hematology, blood chemistry and ultrasonography. In hematology and blood chemistry, the presence of microfilariae in the blood, anemia, leukocytosis, hemoglobinuria and jaundice were revealed. In ultrasonography, heartworms were found in the right ventricle artery and pulmonary artery as structures of hyperechoic dots or streaks. In autopsy, forty odd and fifty odd of heartworms at dog 1 and dog 2, were ascertained respectively in the right ventricle and pulmonary artery.

  • PDF

Spontaneous resolution of new coronary artery aneurysm following guideline-directed medical therapy after drug-eluting stent implantation

  • Jae-Geun Lee;Ki Yung Boo
    • Journal of Medicine and Life Science
    • /
    • 제20권3호
    • /
    • pp.131-134
    • /
    • 2023
  • Here, we present a case of a 56-year-old man with acute myocardial infarction. The patient underwent percutaneous coronary intervention (PCI) at the left main bifurcation and mid-left anterior descending artery using drugeluting stents. Four months after the PCI, the patient was readmitted for cardiac arrest. Coronary angiography (CAG) revealed stent thrombosis in the left main-to-proximal left anterior descending artery and in-stent restenosis in the left main-to-proximal left circumflex artery. We performed balloon angioplasty at the left main to mid-left anterior descending artery and left main to proximal left circumflex artery stents; subsequently, blood flow was fully restored. However, contrast agent extravasation was observed outside the mid-portion of the left main artery to the proximal left anterior descending artery stent, indicating the presence of a coronary artery aneurysm (CAA) outside the stent. After guideline-directed medical therapy with dual antiplatelet agents and high-intensity statins, follow-up CAG revealed near-resolution of the CAA, absence of stenotic lesions, and good blood flow.

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

  • Sung, Kun-Hyuk;Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • 제21권2호
    • /
    • pp.119-126
    • /
    • 2009
  • A numerical analysis is performed to investigate the effect of rotation on the blood flow characteristics with four different angular velocities. The artery has a cylindrical shape with 50% stenosis rate symmetrically distributed at the middle. Blood flow is considered a non-Newtonian fluid. Using the Carreau model, we apply the pulsatile velocity profile at the inlet boundary. The period of the heart beat is one second. In comparison with no-rotation case, the flow recirculation zone (FRZ) contracts and its duration is reduced in axially rotating artery. Also wall shear stress is larger after the FRZ disappears. Although the geometry of artery is axisymmetry, the spiral wave and asymmetric flow occur clearly at the small rotation rate. It is caused that the flow is influenced by the effects of the rotation and the stenosis at same time.

양측 대동맥-신동맥 동시 우회술 치험;1례 보고 (Bilateral Aorto-Renal Bypasses - Report of One Case -)

  • 윤영철
    • Journal of Chest Surgery
    • /
    • 제25권2호
    • /
    • pp.200-204
    • /
    • 1992
  • A 63 year old male had suffered from hypertension and angina pectoris for 4 years, On physical examination, blood pressure was 150/110 mmHg with medication of antihypertensive drugs. Aortogram showed the stenosis of the left renal artery, the complete occlusion of the right renal artery, and atherosclerotic change of abdominal aorta. Blood urea nitrogen was 25 mg/dl, serum creatinine was 1.2 mg/dl, and renin activity in peripheral blood was 8.7 ng /ml /hour, The stenosis of left renal artery and the complete occlusion of right renal artery should have produced the renovascular hypertension Bilateral aorto-renal bypasses with saphenous grafts were done for treatment of ren-ovascular hypertension Postoperatively, blood pressure was normalized with only small dosage of antihypertensive drugs.

  • PDF

혈관계 시스템 모델과 CFD의 결합을 통한 관상동맥 내 혈류의 수치적 해석 (Numerical analysis of the blood flow in coronary artery combining CFD method with the vascular system modeling)

  • 심은보;박명수;고형종;김경훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 추계 학술대회논문집
    • /
    • pp.152-157
    • /
    • 1999
  • For the simulation of the blood flow in coronary artery, the system modeling of coronary hemodynamics is combined with CFD technique. The blood flow in coronary artery interacts with the global coronary circulation. Especially in case of the coronary artery with stenosis, the interaction plays an important role in the hemodynamics of the circulation. In this study we present a combined numerical approach using both the CFD technique for flow simulation and the global system model of coronary circulation. We use a lumped parameter model for the global simulation of coronary circulation whereas the finite element method is employed to compute the viscous flow field in stenosed coronary artery, The time variation of the pressure drop due to stenosis is obtained from the proposed numerical method. Numerical results shows that the flow resistance and pressure drop due to stenosis has a relatively large value in systole.

  • PDF

좌주간부 관상동맥에 관한 혈류역학적 분석 (I) (Hemodynamic Analysis of Pig's Left Common Coronary Artery (I))

  • 박정수;장주희;문수연;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1923-1929
    • /
    • 2003
  • The present study investigated the microcirculation of blood in the left common artery (LCCA). In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary conditions. In this study, the statistical distribution of blood pressure, blood flow, and blood volume in the LCCA were determined based on the anatomical branching pattern of the coronary arterial tree and the statistical data of blood vessel dimensions. Our calculations were in good agreement with the previous studies. The present results showed that the mean longitudinal pressure drop profile was function of the vessel order numbers. It was found that the normalized pressure drop was a logarithmic function of the compliance.

  • PDF

흰쥐의 대퇴동맥 혈전 모델에서의 스트렙토키나제-덱스트란 포합체의 혈전용해효과의 평가 (Evaluation of Thrombolytic Effect of Streptokinase-Dextran Conjugate in a Rat Model of Arterial Thrombosis)

  • 김양우;김동출
    • Journal of Pharmaceutical Investigation
    • /
    • 제29권3호
    • /
    • pp.211-216
    • /
    • 1999
  • To evaluate the thrombolytic activity of streptokinase-dextran conjugate, a rat model of arterial thrombosis was used. Briefly, the femoral artery was exposed and a filter paper saturated with 70% $FeCl_3$ solution was placed around the femoral artery in order to stop the blood flow. Six minutes after the stop of the blood flow in the femoral artery, streptokinase $(10000{\sim}30000\;units\;per\;rat)$ or streptokinase-dextran conjugate $(5000{\sim}17000\;units\;per\;rat)$ was administered by i.v. bolus injection through the femoral vein. Then the blood flow in the femoral artery was monitored using a Doppler laser flow meter. The i.v. bolus administration of streptokinase could not restore the blood flow in the femoral artery in the dose range of $10000{\sim}30000$ units per rat. The i.v. bolus administration of streptokinase-dextran conjugate could restore the blood flow in the femoral artery in the dose range of $5000{\sim}17000$ units per rat. A good correlation between the dose of streptokinase-dextran conjugate and the total thrombolytic effect was observed. In addition, the lag time between the injection of streptokinase-dextran conjugate and the restoring of the blood flow was decreased as the i.v. dose of streptokinase dextran conjugate increased. These results show the superior beneficial effect of streptokinase-dextran conjugate compared with the unconjugated streptokinase with respect to the elongation of thrombolytic activity, the administration method (single injection versus continuous infusion), and the reduced dose necessary for a equivalent thrombolytic effect.

  • PDF

경동맥 협착증 진단을 위한 가상혈관경 (Virtual Angioscopy for Diagnosis of Carotid Artery Stenosis)

  • 김도연;박종원
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제30권9호
    • /
    • pp.821-828
    • /
    • 2003
  • 본 논문은 경동맥(carotid artery)을 환영한 MRA(Magnetic Resonance Angiography) 영상을 이용하여 실제 내시경으로 접근이 불가능한 경동맥의 내부를 시각화(visualization)하기 위해 가상혈관경(virtual angioscopy)을 구현하였다 항해경로 결정을 위해 MRA의 단면 원천영상에서 총경동맥 (common carotid artery) 및 내경동맥(internal carotid artery)만을 분리하였고, 중앙축 변환(MAT Medial Axis Transformation)을 통해 구해진 좌표값을 가상 카메라의 운행 경로로 사용하였다. 원근투영 (perspective projection) 및 볼륨 데이타의 표면을 렌더링하기 위해 마칭큐브(marching rube) 알고리즘을 사용하였다 허혈성으로 인한 뇌혈관질환(cerebrovascular disease)은 뇌졸중(stroke)의 80% 정도를 차지하는데, 경동맥은 뇌에 혈액을 공급하는 주된 혈관으로 경동맥 협착증(carotid artery stenosis)은 뇌졸중의 직접적인 원인이 된다. 가상혈관경은 경동맥 내부의 협착 위치와 협착 정도를 정성적으로 파악 할 수 있으며 협착증의 진단과 교육에 사용될 수 있다.

도플러 초음파를 이용한 중풍환자(中風患者)의 뇌혈관(腦血管) 혈류측정(血流測定)에 관한 임상적(臨床的) 연구(硏究) (경동맥(頸動脈), 추골동맥(椎骨動脈) 및 기저동맥(基底動脈)을 중심으로) (Clinical study on the estimation of blood flow velocity using doppler ultrasound of the cerebral artery in stroke patients)

  • 장인수;선중기
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.345-360
    • /
    • 1996
  • Background and Purpose: To evaluate the blood flow velocity using doppler ultrasound of the carotid artery, vertebral artery, and basilar artery in stroke patients Material and Methods: To evaluate the blood flow, I measured the peak systolic velocity and mean velocity of the common carotid artery(CCA), internal carotid artery(ICA), external carotid artery (ECA). vertebral artery(VA), and basilar artery(BA) in 44 stroke patients and 15 healthy adults. To investigate the difference between ischemic stroke patients and normal healthy adults, I selected 44 ischemic stroke patients diagnosed by brain CT and brain MRI, and 15 healthy adults who did not have any symptoms of stroke, hypertension, heart disease, and diabetes melitus. Results: Peak velocity in normal adults was 50.6${\pm}$1.6cm/sec in the CCA, 67.2${\pm}$1.7cm/sec in the ICA, 62.5${\pm}$2.4cm/see in the ECA, 45.5${\pm}$1.9cm/sec VA. and 50.5${\pm}$3.5cm/sec in the BA. Mean velocity in normal adults was 26.9${\pm}$1.1cm/sec in the CCA, 43.7${\pm}$1.4cm/sec in the ICA, 26.7${\pm}$1.3cm/sec in the ECA. 31.6${\pm}$1.9cm/sec in the VA and 33.0${\pm}$2.6cm/sec in the BA. In this study, there was a significant increase in the velocity of ICA, ECA, and VA of ischemic stroke patients in comparison with normal healthy adults. And the blood flow velocity of this study in the CCA and ECA was different from other reported foreign values and the other known values in my country. Conclusion: There was a significant difference in the blood flow velocity between ischemic stroke patients and normal healthy adults. And the blood flow velocity of this study was different from other reported foreign values and the other known values in my country. Therefore, it needs more detailed studies about old aged Korean and ischemic stroke patients than previous studies.

  • PDF

Ideal Internal Carotid Artery Trapping Technique without Bypass in a Patient with Insufficient Collateral Flow

  • Chung, Joon-Ho;Shin, Yong-Sam;Lim, Yong-Cheol;Park, Min-Jung
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권4호
    • /
    • pp.260-263
    • /
    • 2009
  • Internal carotid artery (ICA) trapping can be used for treating intracranial giant aneurysm, blood blister-like aneurysms and ICA rupture during the surgery. We present a novel ICA trapping technique which can be used with insufficient collaterals flow via anterior communicating artery (AcoA) and posterior communicating artery (PcoA). A patient was admitted with severe headache and the cerebral angiography demonstrated a typical blood blister-like aneurysm at the contralateral side of PcoA. For trapping the aneurysm, the first clip was placed at the ICA just proximal to the aneurysm whereas the distal clip was placed obliquely proximal to the origin of the PcoA to preserve blood flow from the PcoA to the distal ICA. The patient was completely recovered with good collaterals filling to the right ICA territories via AcoA and PcoA. This technique may be an effective treatment option for trapping the aneurysm, especially when the PcoA preservation is mandatory.