• Title/Summary/Keyword: Blood Viscosity

Search Result 123, Processing Time 0.023 seconds

Development and Application Capillary Tube Viscometer Transient Flow Concept (과도유동현상을 이용한 모세관점도계 개발 및 적용)

  • Suh, Sang-Ho;Cho, Min-Tae;Kim, Dong-Joo;Roh, Hyung-Woon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.489-492
    • /
    • 2002
  • The objective of the present study were to measure the viscosities of non-Newtonian fluids by the transient flow concept in a capillary tube and to apply to hemodynamic studies and pump performance evaluations. The developed capillary tube viscometer could be used to measure the viscosities of the non-Newtonian fluids for a wide range of the shear rate by a run of experiment in a very short time interval. The measured viscosities of water and blood fur different shear rates were good agreement with those of the well established data. The measured viscosities for muddy water varied with the shear rates.

  • PDF

Multifunctional Robotic Guidewire System using Spiral-type Magnetic Microrobot with Magnetic Manipulation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.616-621
    • /
    • 2016
  • This paper presents a new multifunctional active guidewire system for medical applications that uses a magnetic microrobot. The study demonstrated that the proposed microrobot system could swim and be controlled under Low-Reynolds-number (Re) environments in blood vessel models. The prototype of the robotic guidewire, which is driven within a three-axis Helmholtz coil system, consists of a guide-wire, spiral blade, drilling tip, and permanent magnet. The spiral-type microrobot showed stable active locomotion between 3 kA/m and 9.1 kA/m under driving frequency up to 70 Hz in a silicone oil (of viscosity 1000 cst). The microrobot produced a maximum moving velocity of $8.08{\times}10^{-3}m/s$ at 70 Hz and 9.1 kA/m. In particular, the robotic guidewire produced 3D locomotion with drilling in the three-axis Helmholtz coil system. We verified active locomotion, towing of guidewire, steering, and drilling of the proposed robotic guidewire system through experimental analyses.

Effect of Heat-Killed Enterococcus Species on the Viability of Yogurt Starters (사균화 Enterococcus Species 첨가에 의한 요구르트 스타터 생장에 미치는 영향)

  • Kim, Seongjun;Park, Dong June;Oh, Sejong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.40 no.1
    • /
    • pp.48-56
    • /
    • 2022
  • Enterococcus species have been reported to produce unique flavoring ingredients in fermented dairy products. Generally, they were found in cheese and fermented dairy products. Enterococcus spp. produce extracellular polysaccharides and reduce blood cholesterol levels in humans. This study used heat-killed E. faecalis and E. faecium in yogurt production to increase safety during consumption. The addition of heat-killed E. faecalis and E. faecium to milk did not affect the fermentation time of yogurt production, the growth of starter cultures, and the viscosity of yogurt. These results concluded that heat-killed Enterococcus, rather than live Enterococcus, is sufficiently possible and even safer to be added to milk products. Enterococcus species could be used as a safe and functional food additive to fermented milk products and supplements in health foods.

Intraaneurysmal Blood Flow Changes for the Different Coil Locations (코일 위치에 따른 동맥류 내부 혈류유동의 변화)

  • 이계한;정우원
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.295-300
    • /
    • 2004
  • Coil embolization technique has been used recently to treat cerebral aneurysms. When a giant or a multilobular aneurysm are treated by roils, filling an aneurysm sac completely with coils is difficult and partial blocking of an aneurysm sac is inevitable. Blood flow characteristics, which nay affect the embolization process of an aneurysm sac, are changed by the locations of coils for the Partially blocked aneurysms. Blood flow fields are also influenced by the geometry of a parent vessel. In order to suggest the coil locations effective for aneurysm embolization, the blood flow fields of lateral aneurysm models were analyzed for the different coil locations and parent vessel geometries. Three dimensional pulsatile flow fields are analyzed by numerical methods considering non-Newtonian viscosity characteristics of blood. Flow rate into the aneurysm sac (inflow rate) and wall shear stress, which are suspected as flow dynamic factors influencing aneurysm embolization, are also calculated. Inflow rates were smaller and the low wall shear stress zones were larger in the neck blocked models compared to the dome blocked models. Smaller inflow and larger low wall shear stress zones in the distal neck blocked model imply that the distal neck should be the effective coil locations for aneurysm embolization.

Total Dietary Fiber and Mineral Absorption

  • Gordon, Dennis-T.
    • Journal of Nutrition and Health
    • /
    • v.25 no.6
    • /
    • pp.429-449
    • /
    • 1992
  • The consumption of foods rich in TDF should not be associated with impaired mineral absorp-tion and long-term mineral status. In surveys of populations consuming high amounts of TDF e.g Third World populations and vegetarinas gross deficiencies in mineral nutrition have not been noted. If mineral status is low among these groups it is most likely caused by the inadequacy or imbalance of the diet and not by the TDF. The key word is interaction which should be inte-rpreted in dietary imbalances that produce nut-rient deficiencies. There are no strong data to support the concept that TDF inhibits mineral absorption through a binding chelation mechanism. Limited data sug-gest that positively charged groups on polymers such as chitosan and cholestyramine will decrease iron absorption in humans and animals. Because TDF does not contain positively charged groups future research should be directed at the possible role of protein consumed along with TDF and the combination of effects on mineral nutrition Phytic acid is acknowledged as a potent chela-tor of zinc. However its association with zinc and its propensity to lower Zn bioavaiability may enhance the absorption of other elements notably copper and iron. The importance of interactions among nutrients including TDF will gain addi-tional attention in the scientific community. Soluble and insoluble dietary fiber function di-fferently in the intestine. Insoluble fibers accele-rate movement through the intestine. Soluble die-tary fibers appear to regulated blood concentra-tions of glucose and cholesterol albeit by some unknown mechanism. In creased viscosity produ-ced by the SDF in the intestine may provide an explanation of how this class of polymers affects plasma glucose cholesterol and other nutrients. Employing a double-perfusion technique in the rat we demonstrated that viscosity produced by SDF will delay transfer of zinc into the circulatory system. This delayed absorption should not be interpreted as decreased utilization. A great deal of additional research is required to prove the importance of luminaly viscosity produced by SDF on slowing nutrient absorption or regulating bllod nutrient homeostasis. Increased intake of TDF in the total human diet appears desirable. A dietary intake of 35g/day should not be considered to have a negative effect on mineral absorption. It is important to educate people that an intake of more than 35g TDF/day may cause an imbalance in the diet that can adve-rsely affect mineral utilization. Acknowledgments. Appreciation is given to Dr. George V. Vahouny(deceased) who was intense a great competitor in and out of science and who gave the author inspiration Portions of this work were supported by the University of Missouri Ag-ricultural Station and by a grant from the Univer-rch Support Grant RR 07053 from the National Institutes of Health. Contribution of the Missouri Agriculatural Experiments Station Journal Series No. 10747.

  • PDF

Physicochemical Properties and Glucose Transport Retarding Effect of Pectin from Flesh of Asian Pear at Different Growth Stages (생장단계별 배 과육에서 추출된 펙틴의 이화학 특성 및 포도당 흡수 저해 효과)

  • Zhang, Xian;Lee, Fan Zhu;Eun, Jong-Bang
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.491-496
    • /
    • 2008
  • Properties of pectin extracted from flesh of Asian pear in 3 cultivars were investigated at different growth stages. The extraction yields of pectin by the acidic treatment decreased during the growth. The $L^*$ value of young fruit was lower than unripe and ripe fruit, and $a^*$ and $b^*$ value were higher in the same cultivars. The degree of esterification (DE) and intrinsic viscosity of pectin were 21.1-41.3% and 1.90-3.81 dL/g, respectively. The pectin extracted from flesh of pear showed about 30% glucose retarding effect. The DE value had a high correlation with retarding effect on glucose transport and intrinsic viscosity (p<0.01 and p<0.05). The intrinsic viscosity of the pectin seems to affect the retardation of glucose transport in blood. Pectin extracted from flesh of Asian pear by acidic treatment could be a good source to develop low calorie and functional food.

Studies on Changes of ${\gamma}$-Globulin and Cholesterol of Rat Blood Fed on Yoghurt and Koumiss (Yoghurt와 Koumiss를 급여한 Rat 혈액중(血液中)의 ${\gamma}$-globulin과 Cholesterol의 변화에 관한 연구)

  • Jo, Gi Hwan;Kim, Dong Shin
    • Current Research on Agriculture and Life Sciences
    • /
    • v.3
    • /
    • pp.151-157
    • /
    • 1985
  • This study was carried (Jut to find out changes of ${\gamma}$-globulin and cholesterol of rat blood fed on yoghurt and Koumiss. Yoghrt and koumiss were manufactured with fortifed milk and Lactobacillus bulgaricus, streptococcus thermophilus and Saccharomyces fragilis were used. The twenty rats were devised into 4 groups with 5 replications by completely randomized design. The experimental groups are the control, milk, yoghrt and koumiss feeding groups. The results are summerized as follows ; The changes of pH after 8hrs incubation with Lactobacillus bulgricus, Streptococcus thermophilus and the mixed strains were 3.7, 4.6 and 3.5 at $42^{\circ}C$, respectively. Average alcohol percentage of Koumiss was 1.2 (%). The average viscosity of yoghurt and Koumiss with milk showed 1500 cp and 390 cp. respectively at 11 % of milk total solid. ${\gamma}$-globulin contents in blood of rat fed on yoghurt and Koumiss were higher than those of control and milk. Cholesterol of rat blood in yoghurt and Koumiss group were lower than those of control and milk group.

  • PDF

A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators (심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색)

  • Lee, Ju-Yeon;Kim, Jaeyoung;Go, Dong-Hyun;Lee, Ji-Won;Lee, Tae-Hee;Park, Chang-Won;Lee, Su-Kyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.136-146
    • /
    • 2022
  • In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for performance evaluation of pulse wave detectors by identifying the development status of domestic and overseas cardiovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular simulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance evaluation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.

Curcumin targets vascular endothelial growth factor via activating the PI3K/Akt signaling pathway and improves brain hypoxic-ischemic injury in neonatal rats

  • Li, Jia;An, Yan;Wang, Jia-Ning;Yin, Xiao-Ping;Zhou, Huan;Wang, Yong-Sheng
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.24 no.5
    • /
    • pp.423-431
    • /
    • 2020
  • This study aimed to evaluate the effect of curcumin on brain hypoxic-ischemic (HI) damage in neonatal rats and whether the phosphoinositide 3-kinase (PI3K)/Akt/vascular endothelial growth factor (VEGF) signaling pathway is involved. Brain HI damage models were established in neonatal rats, which received the following treatments: curcumin by intraperitoneal injection before injury, insulin-like growth factor 1 (IGF-1) by subcutaneous injection after injury, and VEGF by intracerebroventricular injection after injury. This was followed by neurological evaluation, hemodynamic measurements, histopathological assessment, TUNEL assay, flow cytometry, and western blotting to assess the expression of p-PI3K, PI3K, p-Akt, Akt, and VEGF. Compared with rats that underwent sham operation, rats with brain HI damage showed remarkably increased neurological deficits, reduced right blood flow volume, elevated blood viscosity and haematocrit, and aggravated cell damage and apoptosis; these injuries were significantly improved by curcumin pretreatment. Meanwhile, brain HI damage induced the overexpression of p-PI3K, p-Akt, and VEGF, while curcumin pretreatment inhibited the expression of these proteins. In addition, IGF-1 treatment rescued the curcumin-induced down-regulated expression of p-PI3K, p-Akt, and VEGF, and VEGF overexpression counteracted the inhibitory effect of curcumin on brain HI damage. Overall, pretreatment with curcumin protected against brain HI damage by targeting VEGF via the PI3K/Akt signaling pathway in neonatal rats.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF